Contents
THE EUROPEAN COMMISSION,Having regard to the Treaty on the Functioning of the European Union,Having regard to Decision No 676/2002/EC of the European Parliament and of the Council of 7 March 2002 on a regulatory framework for radio spectrum policy in the European Community (Radio Spectrum Decision)note, and in particular Article 4(3) thereof,Whereas:
(1)Short-range devices are typically mass-market or portable radio equipment, or both, that can easily be carried and used across borders. Differences in spectrum access conditions risk creating harmful interference with other radio applications and services, prevent their free movement, and increase their production costs.
(2)Commission Decision 2006/771/ECnote and Commission Implementing Decision (EU) 2018/1538note constitute the regulatory framework for short-range devices, which supports innovation for a wide range of applications within the digital single market.
(3)Decision 2006/771/EC harmonises the technical conditions for spectrum use for a wide variety of short-range devices in application areas such as alarms, local communications, telecommand, medical implants and medical data gathering, intelligent transport systems and the ‘Internet of Things’ including radio-frequency identification (‘RFID’). As a result, short-range devices that respect these harmonised technical conditions are subject to no more than a general authorisation under national law.
(4)Implementing Decision (EU) 2018/1538 also harmonises the technical conditions for spectrum use by short-range devices within the 874-874,4 and 915-919,4 MHz frequency bands. In these frequency bands, the sharing environment is different from the rest of the radio spectrum used by short-range devices and requires a specific regulatory regime. That Decision enables technically advanced RFID solutions as well as ‘Internet of Things’ applications based on networked short-range devices in data networks.
(5)New applications for short-range devices regularly emerge due to the growing importance of these devices for the economy and the rapid changes in technology and societal demands. Such applications require regular updates of harmonised technical conditions for spectrum use.
(6)Based on the permanent mandate that the Commission has issued to the European Conference of Postal and Telecommunications Administrations (‘the CEPT’) in July 2006, pursuant to Article 4(2) of Decision No 676/2002/EC, the Annex to Decision 2006/771/EC should be updated in order to reflect technological and market developments in the area of short-range devices. That Annex has been amended eight times. The work carried out on the basis of the permanent mandate to the CEPT was also the basis for Implementing Decision (EU) 2018/1538 providing additional spectrum for short-range devices within the 874-874,4 and 915-919,4 MHz frequency ranges.
(7)On 21 October 2021, the Commission issued a guidance letter for the ninth update cycle. In response to the permanent mandate to the CEPT and in accordance with that guidance, the CEPT submitted Report 85 to the Commission on 8 March 2024. In addition to improvements of existing entries applicable to active medical implants, RFID, voice and video applications and assistive listening devices, the CEPT proposes to add new entries to the Annex to Decision 2006/771/EC. Those new entries enable the use of spectrum by ground-based Synthetic Aperture Radar (‘SAR’) systems and security scanners. The report should therefore form the technical basis for this Decision.
(8)In Report 85, the CEPT also proposed to include in the Annex to Decision 2006/771/EC technical conditions applicable to audio devices for programme making and special events (‘audio PMSE devices’) that use 32,3 MHz of harmonised spectrum in the 800 MHz and 1800 MHz frequency bands and recommended that Commission Implementing Decision 2014/641/EUnote is repealed.
(9)The Commission, in its Communication of 26 September 2012 to the European Parliament, the Council, the European Economic and Social Committee and the Committee of the Regionsnote, recognised cultural and creative industries as one of Europe’s most dynamic economic sectors and an essential driver of cultural diversity in Europe. In particular, Article 8(5) of Decision No 243/2012/EU of the European Parliament and of the Councilnote, stresses the importance of PMSE and requires Member States, in cooperation with the Commission, to seek to ensure the necessary frequency bands for such equipment, in accordance with the Union’s objectives to improve the integration of the internal market and access to culture.
(10)The requirements for social and cultural events will often exceed the amount of 32,3 MHz available in the 800 MHz and 1800 MHz frequency bands. Since the spectrum requirements for audio PMSE use vary significantly, there is a need to ensure at Union level the availability of at least 62,3 MHz of sustainable spectrum to meet recurring ordinary needs for users of audio PMSE devices.
(11)The additional amount of at least 30 MHz of spectrum to meet possible demand for audio PMSE applications at social and cultural events should be selected from tuning ranges to be decided by Member States, preferably in the 470-790 MHz spectrum range.
(12)Short-range devices operating within the conditions set out in this Decision should also comply with Directive 2014/53/EU of the European Parliament and of the Councilnote.
(13)Decision 2006/771/EC should therefore be amended and Implementing Decision 2014/641/EU should be repealed accordingly.
(14)The measures provided for in this Decision are in accordance with the opinion of the Radio Spectrum Committee,
HAS ADOPTED THIS DECISION:
Article 1#
Decision 2006/771/EC is amended as follows:
(1)in Article 3, the following paragraph is added after paragraph 2:‘2a.Member States shall designate and make available radio spectrum in addition to the spectrum harmonised by this Decision for audio PMSE devices, so that in complement to the bands identified in the Annex, an additional amount of at least 30 MHz can be used for audio PMSE devices, subject to user demand. Such use by audio PMSE devices shall be on a non-interference and non-protected basis with regard to users who have an individual right to use such spectrum.’;
(2)in Article 4a, the date ‘1 October 2022’ is replaced by the date ‘1 November 2025’;
(3)the Annex is replaced by the text set out in the Annex to this Decision.
Article 2#
Implementing Decision 2014/641/EU is repealed with effect from 1 July 2025.
‘’
Frequency bands with corresponding harmonised technical conditions and implementation deadlines for short-range devices
—Member States shall allow adjacent frequency bands set out in Table 2 to be used as a single frequency band provided the specific conditions of each of these adjacent frequency bands are met.
—Member States shall allow the usage of spectrum up to the transmit power, field strength or power density set out in Table 2. Pursuant to Article 3(3), they may impose less restrictive conditions, that is to say allow the use of spectrum with higher transmit power, field strength or power density, provided it does not reduce or compromise the appropriate coexistence between short-range devices in bands harmonised by this Decision.
—Member States may only impose the additional parameters (channelling and/or channel access and occupation rules) set out in Table 2, and shall not add other parameters or spectrum access and mitigation requirements. Less restrictive conditions pursuant to Article 3(3), means that Member States may completely omit these additional parameters in a given cell or allow higher values, provided that the appropriate sharing environment in the harmonised band is not compromised.
—Member States may only impose the other usage restrictions set out in Table 2 and shall not add additional usage restrictions. Since less restrictive conditions may be applied pursuant to Article 3(3), Member States may omit one or all of these restrictions, provided that the appropriate sharing environment in the harmonised band is not compromised.
—Less restrictive conditions pursuant to Article 3(3) shall apply without prejudice to Directive 2014/53/EU.
Table 1 defines the scope of different categories of short-range devices (defined in Article 2(3)) to which this Decision applies. Table 2 specifies different combinations of frequency band and category of short-range devices, and the harmonised technical conditions for spectrum access and implementation deadlines applicable thereto.
General technical conditions applicable to all bands and short-range devices that fall within the scope of this Decision:
For the purposes of this Annex, the following duty cycle definition applies:
“duty cycle” means the ratio, expressed as a percentage, of Σ(Ton)/(Tobs) where Ton is the “on” time of a single transmitter device and Tobs is the observation period. Ton is measured in an observation frequency band (Fobs). Unless otherwise specified in this technical annex, Tobs is a continuous one hour period and Fobs is the applicable frequency band in this technical annex. Less restrictive conditions within the meaning of Article 3(3), mean that Member States may allow a higher value for “duty cycle”.
| Category of short-range devices | Scope |
|---|---|
| Non-specific short-range devices (SRD) | Covers all kinds of radio devices, regardless of the application or their purpose, which fulfil the technical conditions as specified for a given frequency band. Typical uses include telemetry, telecommand, alarms, data transmissions in general and other applications. |
| Active medical implant devices | Covers the radio part of active implantable medical devices that are intended to be fully or partially introduced, surgically or medically, into the human body or that of an animal, and where applicable their peripherals. Active implantable medical devices are defined in Council Directive 90/385/EECnote. |
| Assistive listening devices (ALD) | Covers radio communications systems that allow persons with hearing impairment to increase their listening capability. Typical system installations include one or more radio transmitters and one or more radio receivers. |
| Audio Programme Making and Special Events (PMSE) devices | Covers radio devices used for transmission of analogue or digital audio signals between a limited number of transmitters and receivers, such as radio microphones, in-ear monitors or audio links, used mainly for the production of broadcast programmes or private or public social or cultural events. |
| Inductive devices | Covers radio devices that use magnetic fields with inductive loop systems for near field communications and determination applications. This typically includes devices for car immobilisation, animal identification, alarm systems, cable detection, waste management, personal identification, wireless voice links, access control, proximity and metal sensors, anti-theft systems as well as RF anti-theft induction systems, data transfer to hand-held devices, automatic article identification, wireless control systems and automatic road tolling. |
| Reliable alarm devices | Covers radio devices that use radio communication support for indicating an alert to a system or a person, as a main functionality, at a distant location when a problem or a specific situation occurs. Radio alarms include social alarms and alarms for security and safety. |
| Medical data acquisition devices | Covers the transmission of non-voice data to and from non-implantable medical devices in order to monitor, diagnose and treat patients in healthcare facilities or in their homes as prescribed by duly authorised healthcare professionals. |
| PMR446 devices | Covers hand portable equipment (without base station or repeater use) carried on a person or manually operated, which uses integral antennas only in order to maximise sharing and minimise interference. PMR 446 equipment operates in short-range peer-to-peer mode and shall not be used as a part of infrastructure network nor as a repeater. |
| Radio determination devices | Covers radio devices used for determining the position, velocity and/or other characteristics of an object, or for obtaining information relating to these parameters. Radio determination equipment typically conducts measurements to obtain such characteristics. Radio determination devices exclude any kind of point-to-point or point-to-multipoint radio communications. |
| Radio frequency identification (RFID) devices | Covers tag/interrogator based radio communications systems, consisting of (i) radio devices (tags) attached to animate or inanimate items; and (ii) transmitter/receiver units (interrogators) which activate the tags and receive data back. Typical applications include the tracking and identification of items, for instance for the purpose of electronic article surveillance (EAS), and collecting and transmitting data relating to the items to which tags are attached, which may be either battery-less, battery assisted or battery powered. The responses from a tag are validated by its interrogator and passed to its host system. |
| Transport and traffic telematics devices | Covers radio devices that are used in the fields of transport (road, rail, water or air, depending on the relevant technical restrictions), traffic management, navigation, mobility management and in intelligent transport systems (ITS). Typical applications include interfaces between different modes of transport, communication between vehicles (e.g. car to car), between vehicles and fixed locations (e.g. car to infrastructure) as well as communication from and to users. |
| Wideband data transmission devices | Covers radio devices that use wideband modulation techniques to access the spectrum. Typical uses include wireless access systems such as radio local area networks (WAS/RLAN) or wideband SRD in data networks. |
| Band No | Frequency band | Category of short-range devices | Transmit power limit / field strength limit / power density limit | Additional parameters (channelling and/or channel access and occupation rules) | Other usage restrictions | Implementation deadline |
|---|---|---|---|---|---|---|
| 1 | 9-59,750 kHz | Inductive devices | 72 dBμA/m at 10 metres | 1 July 2014 | ||
| 90 | 9-148 kHz | Radio determination devices | 46 dBμA/m at 10 metres at a reference of 100 Hz, outside the Nuclear Magnetic Resonance (NMR) device.Magnetic field strength descending 10 dB/decade above 100 Hz. | For enclosed Nuclear Magnetic Resonance (NMR) applications [j]. | 1 July 2022 | |
| 2 | 9-315 kHz | Active medical implant devices | 30 dBμA/m at 10 metres | Duty cycle ≤ 10 % | 1 July 2014 | |
| 3 | 59,750-60,250 kHz | Inductive devices | 42 dBμA/m at 10 metres | 1 July 2014 | ||
| 4 | 60,250-74,750 kHz | Inductive devices | 72 dBμA/m at 10 metres | 1 July 2014 | ||
| 5 | 74,750-75,250 kHz | Inductive devices | 42 dBμA/m at 10 metres | 1 July 2014 | ||
| 6 | 75,250-77,250 kHz | Inductive devices | 72 dBμA/m at 10 metres | 1 July 2014 | ||
| 7 | 77,250-77,750 kHz | Inductive devices | 42 dBμA/m at 10 metres | 1 July 2014 | ||
| 8 | 77,750-90 kHz | Inductive devices | 72 dBμA/m at 10 metres | 1 July 2014 | ||
| 9 | 90-119 kHz | Inductive devices | 42 dBμA/m at 10 metres | 1 July 2014 | ||
| 10 | 119-128,6 kHz | Inductive devices | 66 dBμA/m at 10 metres | 1 July 2014 | ||
| 11 | 128,6-129,6 kHz | Inductive devices | 42 dBμA/m at 10 metres | 1 July 2014 | ||
| 12 | 129,6-135 kHz | Inductive devices | 66 dBμA/m at 10 metres | 1 July 2014 | ||
| 13 | 135-140 kHz | Inductive devices | 42 dBμA/m at 10 metres | 1 July 2014 | ||
| 14 | 140-148,5 kHz | Inductive devices | 37,7 dBμA/m at 10 metres | 1 July 2014 | ||
| 15 | 148,5-5000 kHz [1] | Inductive devices | – 15 dBμA/m at 10 metres in any bandwidth of 10 kHz.Furthermore the total field strength is – 5 dΒμΑ/m at 10 metres for systems operating at bandwidths larger than 10 kHz. | 1 July 2014 | ||
| 91 | 148-5000 kHz | Radio determination devices | – 15 dBμA/m at 10 metres outside the Nuclear Magnetic Resonance (NMR) device. | For enclosed Nuclear Magnetic Resonance (NMR) applications [j]. | 1 July 2022 | |
| 16 | 315-600 kHz | Active medical implant devices | – 5 dB μA/m at 10 metres | Duty cycle ≤ 10 % | This set of usage conditions is only available for animal implant devices. | 1 July 2025 |
| 17 | 400-600 kHz | Radio Frequency Identification (RFID) devices | – 8 dBμA/m at 10 metres in any bandwidth of 10 kHz. Furthermore, the total field strength is – 5 dBμA/m at 10 metres for systems operating at bandwidths larger than 10 kHz. | Bandwidth ≥ 30 kHz | 1 July 2025 | |
| 85 | 442,2-450,0 kHz | Non-specific short-range devices | 7 dBμA/m at 10 metres | Channel spacing ≥ 150 Hz | This set of usage conditions is only available for person detection and collision avoidance devices. | 1 January 2020 |
| 18 | 456,9-457,1 kHz | Non-specific short-range devices | 7 dBμA/m at 10 metres | This set of usage conditions is only available for emergency detections of buried victims and valuable items devices. | 1 July 2014 | |
| 19 | 984-7484 kHz | Transport and Traffic Telematics devices | 9 dBμA/m at 10 metres | Duty cycle ≤ 1 % | This set of usage conditions is only available for Eurobalise transmissions in the presence of trains using the 27090-27100 kHz band for telepowering pursuant to the conditions set for band 28. | 1 July 2014 |
| 20 | 3155-3400 kHz | Inductive devices | 13,5 dBμA/m at 10 metres | 1 July 2014 | ||
| 21 | 5000-30000 kHz [2] | Inductive devices | – 20 dBμA/m at 10 metres in any bandwidth of 10 kHz.Furthermore the total field strength is – 5 dΒμΑ/m at 10 metres for systems operating at bandwidths larger than 10 kHz. | 1 July 2014 | ||
| 92 | 5000-30000 kHz | Radio determination devices | – 5 dBμA/m at 10 metres outside the Nuclear Magnetic Resonance (NMR) device. | For enclosed Nuclear Magnetic Resonance (NMR) applications [j]. | 1 July 2022 | |
| 22 | 6765-6795 kHz | Inductive devices | 42 dBμA/m at 10 metres | 1 July 2014 | ||
| 23 | 7300-23000 kHz | Transport and Traffic Telematics devices | – 7 dBμA/m at 10 metres | Antenna requirements apply [8]. | This set of usage conditions is only available for Eurobalise transmissions in the presence of trains using the 27090-27100 kHz band for telepowering pursuant to the conditions set for band 28. | 1 July 2014 |
| 24 | 7400-8800 kHz | Inductive devices | 9 dBμA/m at 10 metres | 1 July 2014 | ||
| 25 | 10200-11000 kHz | Inductive devices | 9 dBμA/m at 10 metres | 1 July 2014 | ||
| 26 | 12500-20000 kHz | Active medical implant devices | – 7 dBμA/m at 10 metres in any bandwidth of 10 kHz | Duty cycle ≤ 10 % | This set of usage conditions is only available for indoor use by animal implant devices. | 1 July 2025 |
| 27a | 13553-13567 kHz | Inductive devices | 42 dBμA/m at 10 metres | Transmission mask and antenna requirements for all combined frequency segments apply [8], [9]. | 1 January 2020 | |
| 27b | 13553-13567 kHz | Radio Frequency Identification (RFID) devices | 60 dBμA/m at 10 metres | Transmission mask and antenna requirements for all combined frequency segments apply [8], [9]. | 1 July 2014 | |
| 27c | 13553-13567 kHz | Non-specific short-range devices | 10 mW e.r.p. | 1 July 2014 | ||
| 28 | 26957-27283 kHz | Non-specific short-range devices | 10 mW e.r.p. | 1 July 2014 | ||
| 29 | 26990-27000 kHz | Non-specific short-range devices | 100 mW e.r.p. | Duty cycle ≤ 0,1 %Model control devices [d] may operate without duty cycle restrictions. | 1 July 2014 | |
| 30 | 27040-27050 kHz | Non-specific short-range devices | 100 mW e.r.p. | Duty cycle ≤ 0,1 %Model control devices [d] may operate without duty cycle restrictions. | 1 July 2014 | |
| 31 | 27090-27100 kHz | Non-specific short-range devices | 100 mW e.r.p. | Duty cycle ≤: 0,1 %Model control devices [d] may operate without duty cycle restrictions. | 1 July 2014 | |
| 32 | 27140-27150 kHz | Non-specific short-range devices | 100 mW e.r.p. | Duty cycle ≤ 0,1 %Model control devices [d] may operate without duty cycle restrictions. | 1 July 2014 | |
| 33 | 27190-27200 kHz | Non-specific short-range devices | 100 mW e.r.p. | Duty cycle ≤ 0,1 %Model control devices [d] may operate without duty cycle restrictions. | 1 July 2014 | |
| 34 | 30-37,5 MHz | Active medical implant devices | 1 mW e.r.p. | Duty cycle ≤ 10 % | This set of usage conditions is only available for ultra-low power medical membrane implants for blood pressure measurements. | 1 July 2014 |
| 93 | 30-130 MHz | Radio determination devices | – 36 dBm e.r.p. outside the Nuclear Magnetic Resonance (NMR) device. | For enclosed Nuclear Magnetic Resonance (NMR) applications [j]. | 1 July 2022 | |
| 35 | 40,66-40,7 MHz | Non-specific short-range devices | 10 mW e.r.p. | 1 January 2018 | ||
| 36 | 87,5-108 MHz | Non-specific short-range devices | 50 nW e.r.p. | Bandwidth ≤ 200 kHz. | This set of usage conditions is only available for audio transmitters with analogue frequency modulation (FM). | 1 July 2025 |
| 37a | 169,4-169,475 MHz | Assistive Listening Devices (ALD) | 500 mW e.r.p. | 1 July 2025 | ||
| 37c | 169,4-169,475 MHz | Non-specific short-range devices | 500 mW e.r.p. | Duty cycle ≤ 1,0 %For metering devices [a], the duty cycle ≤ 10 % | 1 July 2025 | |
| 38 | 169,4-169,4875 MHz | Non-specific short-range devices | 10 mW e.r.p. | Duty cycle ≤ 0,1 % | 1 January 2020 | |
| 39a | 169,4875-169,5875 MHz | Assistive Listening Devices (ALD) | 500 mW e.r.p. | 1 July 2025 | ||
| 39b | 169,4875-169,5875 MHz | Non-specific short-range devices | 10 mW e.r.p. | Duty cycle ≤ 0,001 %Between 00:00h and 06:00h local time a duty cycle ≤ 0,1 % may be used. | 1 January 2020 | |
| 40 | 169,5875-169,8125 MHz | Non-specific short-range devices | 10 mW e.r.p. | Duty cycle ≤ 0,1 % | 1 January 2020 | |
| 82 | 173,965-216 MHz | Assistive Listening Devices (ALD) | 10 mW e.r.p. | On a tuning range basis [5].A threshold of 35 dBμV/m is required to ensure the protection of a DAB receiver located at 1,5 metres from the ALD device, subject to DAB signal strength measurements taken around the ALD operating site. The ALD device should operate under all circumstances at least 300 kHz away from the channel edge of an occupied DAB channel.Requirements on techniques to access spectrum and mitigate interference apply [7]. | 1 July 2025 | |
| 41 | 401-402 MHz | Active medical implant devices | 25 μW e.r.p. | Bandwidth ≤ 100 kHzRequirements on techniques to access spectrum and mitigate interference apply [7].Alternatively, a duty cycle limit of 0,1 % applies. | This set of usage conditions is only available for systems specifically designed for the purpose of providing non-voice digital communications between active implantable medical devices and/or body-worn devices and other devices external to the human body used for transferring non-time-critical individual patient-related physiological information. | 1 July 2025 |
| 42 | 402-405 MHz | Active medical implant devices | 25 μW e.r.p. | Bandwidth ≤ 300 kHz.Other techniques to access spectrum or mitigate interference, including bandwidths greater than 300 kHz, can be used provided they ensure compatible operation with the other users and in particular with meteorological radiosondes [7]. | 1 July 2025 | |
| 43 | 405-406 MHz | Active medical implant devices | 25 μW e.r.p. | Bandwidth ≤ 100 kHzRequirements on techniques to access spectrum and mitigate interference apply [7].Alternatively, a duty cycle limit of 0,1 % applies. | This set of usage conditions is only available for systems specifically designed for the purpose of providing non-voice digital communications between active implantable medical devices and/or body-worn devices and other devices external to the human body used for transferring non-time-critical individual patient-related physiological information. | 1 July 2025 |
| 86 | 430-440 MHz | Medical data acquisition devices | – 50 dBm/100kHz e.r.p. power density but not exceeding a total power of – 40 dBm/10MHz (both limits are intended for measurement outside of the patient’s body) | The set of usage conditions is only available for Ultra-Low Power Wireless Medical Capsule Endoscopy (ULP-WMCE) applications [h]. | 1 January 2020 | |
| 44a | 433,05-434,79 MHz | Non-specific short-range devices | 1 mW e.r.p. | 1 July 2025 | ||
| 44b | 433,05-434,79 MHz | Non-specific short-range devices | 10 mW e.r.p. | Duty cycle ≤ 10 % | 1 January 2020 | |
| 45c | 434,04-434,79 MHz | Non-specific short-range devices | 10 mW e.r.p. | Duty cycle ≤ 100 % subject to bandwidth ≤ 25 kHz. | 1 July 2025 | |
| 83 | 446,0-446,2 MHz | PMR446 | 500 mW e.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7]. | 1 January 2018 | |
| 94 | 821,5-826 MHz | Audio PMSE devices | 100 mW e.i.r.p. for body-worn devices20 mW e.i.r.p. for other devices | 1 July 2025 | ||
| 95 | 826-832 MHz | Audio PMSE devices | 100 mW e.i.r.p. | 1 July 2025 | ||
| 87 | 862-863 MHz | Non-specific short-range devices | 25 mW e.r.p. | Duty cycle ≤ 0,1 %Bandwidth ≤ 350 kHz | 1 January 2020 | |
| 46a | 863-865 MHz | Non-specific short-range devices | 25 mW e.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7].Alternatively, a duty cycle ≤ 0,1 % applies. | 1 January 2018 | |
| 46b | 863-865 MHz | Audio PMSE devices | 10 mW e.r.p. | This set of usage conditions is also available for personal cordless audio devices. | 1 July 2025 | |
| 84 | 863-868 MHz | Wideband data transmission devices | 25 mW e.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7].Bandwidth > 600 kHz and ≤ 1 MHzDuty cycle ≤ 10 % for network access points [g]Duty cycle ≤ 2,8% otherwise | This set of usage conditions is only available for wideband SRD in data networks [g]. | 1 January 2018 |
| 47 | 865-868 MHz | Non-specific short-range devices | 25 mW e.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7].Alternatively, a duty cycle ≤ 1 % applies. | 1 January 2020 | |
| 47a | 865-868 MHz [6] | Radio Frequency Identification (RFID) devices | Interrogator transmissions at 2 W e.r.p. only permitted within the channels centred at 865,7 MHz, 866,3 MHz, 866,9 MHz and 867,5 MHzRFID interrogator devices placed on the market before the repeal date of EC Decision 2006/804/EC are “grandfathered”, i.e. they are continuously permitted to be used in line with the provisions set out in EC Decision 2006/804/EC before the repeal date. | Requirements on techniques to access spectrum and mitigate interference apply [7].Bandwidth ≤ 200 kHz | 1 January 2018 | |
| 47b | 865-868 MHz | Non-specific short-range devices | 500 mW e.r.p.Transmissions only permitted within the frequency ranges 865,6-865,8 MHz, 866,2-866,4 MHz, 866,8-867,0 MHz and 867,4-867,6 MHz,Adaptive Power Control (APC) required. Alternatively other mitigation technique with at least an equivalent level of spectrum compatibility. | Requirements on techniques to access spectrum and mitigate interference apply [7].Bandwidth ≤ 200 kHzDuty cycle ≤ 10 % for network access points [g]Duty cycle ≤ 2,5 % otherwise | This set of usage conditions is only available for data networks [g]. | 1 January 2018 |
| 48 | 868-868,6 MHz | Non-specific short-range devices | 25 mW e.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7].Alternatively, a duty cycle ≤ 1 % applies. | 1 January 2020 | |
| 49 | 868,6-868,7 MHz | Reliable alarm devices | 10 mW e.r.p. | Bandwidth ≤ 25 kHz. The whole frequency band may also be used as a single channel.Duty cycle ≤ 1 % | 1 July 2025 | |
| 50 | 868,7-869,2 MHz | Non-specific short-range devices | 25 mW e.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7].Alternatively, a duty cycle ≤ 0,1 % applies. | 1 January 2020 | |
| 51 | 869,2-869,25 MHz | Reliable alarm devices | 10 mW e.r.p. | Channel spacing: 25 kHz.Duty cycle ≤ 0,1 % | This set of usage conditions is only available for social alarm devices [b]. | 1 July 2014 |
| 52 | 869,25-869,3 MHz | Reliable alarm devices | 10 mW e.r.p. | Bandwidth ≤ 25 kHzDuty cycle ≤ 0,1 % | 1 July 2025 | |
| 53 | 869,3-869,4 MHz | Reliable alarm devices | 10 mW e.r.p. | Bandwidth ≤ 25 kHzDuty cycle ≤ 1 % | 1 July 2025 | |
| 54 | 869,4-869,65 MHz | Non-specific short-range devices | 500 mW e.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7].Alternatively, a duty cycle ≤ 10 % applies. | 1 January 2020 | |
| 55 | 869,65-869,7 MHz | Reliable alarm devices | 25 mW e.r.p. | Bandwidth ≤ 25 kHzDuty cycle ≤ 10 % | 1 July 2025 | |
| 56a | 869,7-870 MHz | Non-specific short-range devices | 5 mW e.r.p. | 1 July 2025 | ||
| 56b | 869,7-870 MHz | Non-specific short-range devices | 25 mW e.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7].Alternatively, a duty cycle ≤ 1 % applies. | 1 January 2020 | |
| 96 | 1785-1804,8 MHz | Audio PMSE devices | 50 mW e.i.r.p. for body-worn devices or devices implementing Spectrum Scanning Procedure (SSP).20 mW e.i.r.p. for other devices. | 1 July 2025 | ||
| 57a | 2400-2483,5 MHz | Non-specific short-range devices | 10 mW e.i.r.p. | 1 July 2014 | ||
| 57b | 2400-2483,5 MHz | Radio determination devices | 25 mW e.i.r.p. | 1 July 2014 | ||
| 57c | 2400-2483,5 MHz | Wideband data transmission devices | 100 mW e.i.r.p. and 100 mW/100 kHz e.i.r.p. density applies when frequency hopping modulation is used.10 mW/MHz e.i.r.p. density applies when other types of modulation are used. | Requirements on techniques to access spectrum and mitigate interference apply [7]. | 1 July 2014 | |
| 58 | 2446-2454 MHz | Radio Frequency Identification (RFID) devices | 500 mW e.i.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7]. | 1 July 2014 | |
| 59 | 2483,5-2500 MHz | Active medical implant devices | 10 mW e.i.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7].Bandwidth ≤ 1 MHz. The whole frequency band may also be used dynamically as a single channel to maintain a communications session.Duty cycle ≤ 10 % for peripherals. | Peripheral master units are for indoor use only. | 1 July 2025 |
| 59a | 2483,5-2500 MHz | Medical data acquisition devices | 1 mW e.i.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7].Bandwidth ≤ 3 MHz.Duty cycle ≤ 10 %. | The set of usage conditions is only available for medical body area network system (MBANS) [f] for indoor use within healthcare facilities. | 1 January 2018 |
| 59b | 2483,5-2500 MHz | Medical data acquisition devices | 10 mW e.i.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7].Bandwidth ≤ 3 MHz.Duty cycle ≤ 2 %. | The set of usage conditions is only available for medical body area network system (MBANS) [f] for indoor use within the patient’s home. | 1 January 2018 |
| 60 | 4500-7000 MHz | Radio determination devices | 24 dBm e.i.r.p. [3] | Requirements on techniques to access spectrum and mitigate interference apply [7]. | This set of usage conditions is only available for Tank Level Probing Radar [c]. | 1 July 2014 |
| 61 | 5725-5875 MHz | Non-specific short-range devices | 25 mW e.i.r.p. | 1 July 2014 | ||
| 62 | 5795-5815 MHz | Transport and Traffic Telematics devices | 2 W e.i.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7]. | This set of usage conditions applies only to road tolling applications and smart tachograph, weight and dimension applications [i]. | 1 January 2020 |
| 88 | 5855-5865 MHz | Transport and Traffic Telematics devices | 33 dBm e.i.r.p., 23 dBm/MHz e.i.r.p. density and a Transmit Power Control (TPC) able to reduce the total power from its maximum to 3 dBm e.i.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7]. | This set of usage conditions is only available for vehicle-to-vehicle, vehicle-to-infrastructure and infrastructure-to-vehicle systems. | 1 July 2025 |
| 89 | 5865-5875 MHz | Transport and Traffic Telematics devices | 33 dBm e.i.r.p., 23 dBm/MHz e.i.r.p. density and a Transmit Power Control (TPC) able to reduce the total power from its maximum to 3 dBm e.i.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7]. | This set of usage conditions is only available for vehicle-to-vehicle, vehicle-to-infrastructure and infrastructure-to-vehicle systems. | 1 July 2025 |
| 63 | 6000-8500 MHz | Radio determination devices | 7 dBm/50 MHz peak e.i.r.p. and – 33 dBm/MHz mean e.i.r.p. | Automatic power control and antenna requirements as well as requirements on techniques to access spectrum and mitigate interference apply [7], [8] [10]. | This set of usage conditions is only available for Level Probing Radar.Exclusion zones around radio astronomy sites shall apply. | 1 July 2014 |
| 64 | 8500-10600 MHz | Radio determination devices | 30 dBm e.i.r.p. [3] | Requirements on techniques to access spectrum and mitigate interference apply [7]. | This set of usage conditions is only available for Tank Level Probing Radar [c]. | 1 July 2014 |
| 65 | 17,1-17,3 GHz | Radio determination devices | 26 dBm e.i.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7]. | This set of usage conditions is only available for ground-based SAR systems [k]. | 1 July 2025 |
| 66 | 24,05-24,075 GHz | Transport and Traffic Telematics devices | 100 mW e.i.r.p. | 1 July 2014 | ||
| 67 | 24,05-26,5 GHz | Radio determination devices | 26 dBm/50 MHz peak e.i.r.p. and – 14 dBm/MHz mean e.i.r.p. | Automatic power control and antenna requirements as well as requirements on techniques to access spectrum and mitigate interference apply [7]. [8], [10] | This set of usage conditions is only available for Level Probing Radar.Exclusion zones around radio astronomy sites shall apply. | 1 July 2014 |
| 68 | 24,05-27 GHz | Radio determination devices | 43 dBm e.i.r.p. [3] | Requirements on techniques to access spectrum and mitigate interference apply [7]. | This set of usage conditions is only available for Tank Level Probing Radar [c]. | 1 July 2014 |
| 69a | 24,075-24,15 GHz | Transport and Traffic Telematics devices | 100 mW e.i.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7]. | This set of usage conditions is only available for ground-based vehicle radars. | 1 July 2014 |
| 69b | 24,075-24,15 GHz | Transport and Traffic Telematics devices | 0,1 mW e.i.r.p. | 1 July 2014 | ||
| 70a | 24,15-24,25 GHz | Non-specific short-range devices | 100 mW e.i.r.p. | 1 July 2014 | ||
| 70b | 24,15-24,25 GHz | Transport and Traffic Telematics devices | 100 mW e.i.r.p. | 1 July 2014 | ||
| 74a | 57-64 GHz | Non-specific short-range devices | 100 mW e.i.r.p. and a maximum transmit power of 10 dBm | 1 January 2020 | ||
| 74b | 57-64 GHz | Radio determination devices | 43 dBm e.i.r.p. [3] | Requirements on techniques to access spectrum and mitigate interference apply [7]. | This set of usage conditions is only available for Tank Level Probing Radar [c]. | 1 July 2014 |
| 74c | 57-64 GHz | Radio determination devices | 35 dBm/50 MHz peak e.i.r.p. and – 2 dBm/MHz mean e.i.r.p. | Automatic power control and antenna requirements as well as requirements on techniques to access spectrum and mitigate interference apply [7] [8], [10]. | This set of usage conditions is only available for Level Probing Radar. | 1 July 2014 |
| 75 | 57-71 GHz | Wideband data transmission devices | 40 dBm e.i.r.p. and 23 dBm/MHz e.i.r.p. density | Requirements on techniques to access spectrum and mitigate interference apply [7]. | Fixed outdoor installations are excluded. | 1 January 2020 |
| 75a | 57-71 GHz | Wideband data transmission devices | 40 dBm e.i.r.p., 23 dBm/MHz e.i.r.p. density and maximum transmit power of 27 dBm at the antenna port or ports | Requirements on techniques to access spectrum and mitigate interference apply [7]. | 1 January 2020 | |
| 75b | 57-71 GHz | Wideband data transmission devices | 55 dBm e.i.r.p., 38 dBm/MHz e.i.r.p. density and a transmit antenna gain ≥ 30 dBi | Requirements on techniques to access spectrum and mitigate interference apply [7]. | This set of usage conditions is only available for fixed outdoor installations. | 1 January 2020 |
| 76 | 61-61,5 GHz | Non-specific short-range devices | 100 mW e.i.r.p. | 1 July 2014 | ||
| 77 | 63,72-65,88 GHz | Transport and Traffic Telematics devices | 40 dBm e.i.r.p. | TTT devices placed on the market before the 1 January 2020 are “grandfathered”, i.e. they are permitted to use the previous frequency range 63-64 GHz, and otherwise the same conditions apply. | This set of usage conditions is only available to vehicle-to-vehicle, vehicle-to-infrastructure and infrastructure-to-vehicle systems. | 1 January 2020 |
| 97 | 69,8-79,9 GHz | Radio determination devices | 7 dBm e.i.r.p. | This set of usage conditions is available for security scanners [l] operated indoors. | 1 July 2025 | |
| 78a | 75-85 GHz | Radio determination devices | 34 dBm/50 MHz peak e.i.r.p. and – 3 dBm/MHz mean e.i.r.p. | Automatic power control and antenna requirements as well as requirements on techniques to access spectrum and mitigate interference apply [7], [8], [10]. | This set of usage conditions is only available for Level Probing Radar.Exclusion zones around radio astronomy sites shall apply. | 1 July 2014 |
| 78b | 75-85 GHz | Radio determination devices | 43 dBm e.i.r.p. [3] | Requirements on techniques to access spectrum and mitigate interference apply [7]. | This set of usage conditions is only available for Tank Level Probing Radar [c]. | 1 July 2014 |
| 79a | 76-77 GHz | Transport and Traffic Telematics devices | 55 dBm peak e.i.r.p. and 50 dBm mean e.i.r.p. and 23,5 dBm mean e.i.r.p. for pulse radars | Requirements on techniques to access spectrum and mitigate interference apply [7].Fixed transportation infrastructure radars have to be of a scanning nature in order to limit the illumination time and ensure a minimum silent time to achieve coexistence with automotive radar systems. | This set of usage conditions is only available for ground-based vehicle and infrastructure systems. | 1 June 2020 |
| 79b | 76-77 GHz | Transport and Traffic Telematics devices | 30 dBm peak e.i.r.p. and3 dBm/MHz average e.i.r.p. density | Duty cycle ≤ 56 %/s | This set of usage conditions is only available for obstacle detection systems for rotorcraft use [4].Exclusion zones around radio astronomy sites shall apply. | 1 July 2025 |
| 98 | 76-77 GHz | Radio determination devices | 48 dBm mean e.i.r.p. and 18 dBm/MHz mean e.i.r.p. density | Requirements on techniques to access spectrum and mitigate interference apply [7]. | This set of usage conditions is only available for ground-based SAR systems [k].Exclusion zones around radio astronomy sites shall apply. | 1 July 2025 |
| 99 | 76,5-80,5 GHz | Radio determination devices | 19 dBm peak e.i.r.p. | At least 23 dB out-of-band attenuation relative to the maximum allowed peak e.i.r.p. is required. | This set of usage conditions is only available for security scanners [l] operated indoors. | 1 July 2025 |
| 80a | 122-122,25 GHz | Non-specific short-range devices | 10 dBm/250 MHz e.i.r.p. and– 48 dBm/MHz at 30° elevation | 1 January 2018 | ||
| 80b | 122,25-123 GHz | Non-specific short-range devices | 100 mW e.i.r.p. | 1 January 2018 | ||
| 81 | 244-246 GHz | Non-specific short-range devices | 100 mW e.i.r.p. | 1 July 2014 |
Source: EUR-Lex, © European Union, 1998-2026. Reuse authorised under Decision 2011/833/EU.