s luminous flux by its power, measured under equilibrium conditions at the time of determining the luminous flux; and(b)in the case of a general service incandescent reflector lamp, rounding the number calculated under paragraph (a) to the nearest half number. (efficacité lumineuse)
Whereas, pursuant to section 26 of the Energy Efficiency Act, a copy of the proposed Energy Efficiency Regulations, 2016, substantially in the annexed form, was published in the Canada Gazette, Part I, on April 30, 2016;noteTherefore, His Excellency the Governor General in Council, on the recommendation of the Minister of Natural Resources, pursuant to sections 20 and 25 of the Energy Efficiency Act, makes the annexed Energy Efficiency Regulations, 2016.note
adhesive tag means a label that is attached to an energy-using product by at least two strips of adhesive that are located on opposite edges of the label. (étiquette adhésive)
AHRI means the Air-Conditioning, Heating and Refrigeration Institute. (AHRI)
ANSI means the American National Standards Institute. (ANSI)
ASHRAE means the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE)
CIE means the International Commission on Illumination. (CIE)
CSA means the Canadian Standards Association. (CSA)
flap tag means a label whose top edge is attached to an energy-using product by one strip of adhesive. (vignette)
hang tag means a label that is attached to an energy-using product by material that is looped around a section of the product so that the label hangs freely from the product. (étiquette volante)
household means manufactured or sold primarily for use in a dwelling. (domestique)
IEC means the International Electrotechnical Commission. (CEI)
IEEE means the Institute of Electrical and Electronics Engineers. (IEEE)
IES means the Illuminating Engineering Society of North America. (IES)
mains power means an alternating current electric power source that is in a building and is less than or equal to a nominal 240-volt single-phase supply. (alimentation principale)
model number means, in respect of any model of an energy-using product, the designator that is assigned to that model for the purposes of these Regulations and that distinguishes it from similar models. (numéro de modèle)
NEMA means the National Electrical Manufacturers Association. (NEMA)
unique motor identifier means an identifier consisting of the information set out below, in the following sequence:
(a)the name of the manufacturer, in abbreviated form;
(b)the nominal power of the motor, expressed in kilowatts for an IEC design motor or in horsepower for a NEMA design motor;
(c)the number of poles; and
(d)a statement as to whether the motor is of open or enclosed construction. (identificateur unique du moteur)
(2)In these Regulations, a reference to an energy-using product is a reference to that product as defined in the Division or Subdivision associated with it.
(3)In these Regulations, a reference to an AHRI, ANSI, ASHRAE, CGA, CIE, CSA, IEC, IEEE, IES or NEMA standard or to a technical standards document is to be read as a reference to the standard or technical standards document as amended from time to time.
(4)In these Regulations, a reference to a testing standard that is incorporated by reference does not include any test procedure waiver that may be set out in that standard.
certification body means, in respect of an energy-using product, a body that is accredited by the Standards Council of Canada to operate a certification program in respect of the energy efficiency of the product. (organisme de certification)
verification mark means, in respect of an energy-using product, a mark that is
10 C.F.R. Appendix D2 means Appendix D2 to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Clothes Dryers, as amended from time to time. (appendice D2 10 C.F.R.)
Federal laws of Canada reproduced under the Reproduction of Federal Law Order (SI/97-5); not the official version. Source: Justice Laws Website.
(ii)if the product is one for which information must be provided to the Minister for the purpose of subsection 5(1) of the Act, verified the information that is related to the product’s energy performance; or
(b)issued by a province to signify that the product complies with the province’s energy efficiency standard. (marque de vérification)
Unless otherwise specified by these Regulations, an energy-using product that is incorporated into another product remains an energy-using product for the purposes of these Regulations even if the other product is not an energy-using product.
(1)Subject to subsection (4), every energy-using product that, for the purpose of sale or lease, is shipped from one province to another or imported into Canada must be labelled with a verification mark that is issued by
(b)a province whose energy efficiency standard for the product is equivalent to or exceeds the energy efficiency standard prescribed for the product in these Regulations.
(2)The verification mark must be readily visible on the surface of the energy-using product. However, in respect of the following energy-using products, the verification mark may be on the exterior of the product’s package:
(4)An external power supply is not required to be labelled with a verification mark if
(a)it is labelled with a mark in accordance with the U.S. Department of Energy publication entitled “International Efficiency Marking Protocol for External Power Supplies”, as amended from time to time;
(b)a certification body has verified the information related to the product’s energy performance that is provided to the Minister for the purpose of subsection 5(1) of the Act; and
(c)it is labelled with the same model number as that used when the information was verified.
(1)A dealer is exempt from the application of paragraph 4(1)(a) of the Act if the dealer, for the purpose of modifying an energy-using product to comply with the applicable energy efficiency standard, ships the product from the province in which it was manufactured to another province or imports the product into Canada.
(2)The dealer must
(a)ensure that the product is brought into compliance with the applicable energy efficiency standard within 90 days after the day on which the product is shipped or imported;
(b)despite subsection 5(2), provide the information referred to in subsection 5(1) within 120 days after the day on which the product is shipped or imported; and
(c)if requested by the Minister, provide the Minister with any other information that is necessary to establish that the product has been brought into compliance with the applicable energy efficiency standard.
9Exemption — incorporation into product for export#
A dealer is exempt from the application of sections 4 and 5 of the Act with respect to the shipment or importation of an energy-using product that is to be incorporated into any other product that is to be exported from Canada.
A dealer is exempt from the application of sections 4 and 5 of the Act if the dealer, for the purpose of exporting the energy-using product from Canada, ships the product from the province in which it was manufactured to another province or imports the product into Canada.
11Exemption — motors with same unique motor identifier#
A dealer is exempt from the application of section 5 of the Act in respect of a motor if
(a)the information has been provided in respect of a motor that has the same unique motor identifier; and
(b)the motor is at least as energy efficient as the motor for which the information was provided.
CSA C360-03 means the CSA standard CAN/CSA-C360-03 entitled Energy Performance, Water Consumption and Capacity of Household Clothes Washers. (CSA C360-03)
CSA C360-13 means the CSA standard CAN/CSA-C360-13 entitled Energy Performance, Water Consumption and Capacity of Household Clothes Washers. (CSA C360-13)
CSA C361-92 means the CSA standard CAN/CSA-C361-92 entitled Test Method for Measuring Energy Consumption and Drum Volume of Electrically Heated Household Tumble-Type Clothes Dryers. (CSA C361-92)
(1)An energy-using product prescribed in any of Subdivisions A to G or K of this Division must be labelled in the form set out in Schedule 1.
(2)The label must be an adhesive tag, flap tag or hang tag that is attached to the product so that the tag is readily visible when the product is viewed from the front.
(1)The paper that is used for adhesive tags or flap tags must weigh, exclusive of the release liner and adhesive, not less than the equivalent of 26.31 kg (58 pounds) per 500 sheets measuring 63.5 cm (25 inches) by 96.52 cm (38 inches).
(2)The adhesive that is used to attach an adhesive tag or a flap tag to an energy-using product must
(a)render the tag easily removable from the product without the use of a tool or any liquid other than water; and
(b)have an adhesion capacity that is sufficient to prevent the tag from being dislodged from the product under normal handling conditions.
(1)The paper that is used for hang tags must weigh not less than the equivalent of 49.9 kg (110 pounds) per 500 sheets measuring 64.77 cm (25.5 inches) by 77.47 cm (30.5 inches).
(2)The material that is used to attach a hang tag to an energy-using product must be of sufficient strength to ensure that when gradual pressure is applied to the tag by pulling it away from the product, the tag will tear before the material breaks.
(1)A clothes dryer is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 19, a clothes dryer is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to clothes dryers that are manufactured during the periods set out in column 3.
(2)A clothes dryer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a clothes dryer as defined in section 16. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C361-92 | CSA C361-92, Table 8.1 | On or after February 3, 1995 and before January 1, 20152 | CSA C361-16 or 10 C.F.R. Appendix D2 | CSA C361-16, Table 1 | On or after January 1, 2015
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a clothes dryer described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Clothes dryers manufactured on or after February 3, 1995 and before January 1, 2015 | CSA C361-92 | (a)size category;(b)nominal voltage;(c)capacity, in L, of clothes dryer’s drum;(d)annual energy consumption in kWh;(e)energy factor in kg/kWh; and(f)drying controls the product has, namely, timed, auto-temp or auto-moisture.2 | Clothes dryers manufactured on or after January 1, 2015 | CSA C361-16 or 10 C.F.R. Appendix D2 | (a)size category;(b)nominal voltage;(c)capacity, in L, of clothes dryer’s drum;(d)annual energy consumption in kWh;(e)combined energy factor in kg/kWh; and(f)drying controls the product has, namely, timed, auto-temp or auto-moisture.note
In this Subdivision, clothes washer means an electrically operated clothes washer that does not require mechanical fastening to a floor or wall, is top- or front-loaded and has an internal control system that regulates the water temperature without the need for user intervention after the machine is set in operation.
(1)The energy efficiency standards set out in column 3 of the table to this section apply to clothes washers described in column 1 that are manufactured during the periods set out in column 4.
(2)A clothes washer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a clothes washer as defined in section 21. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Clothes washers | CSA C360-03 | CSA C360-03, Table 9 | On or after February 3, 1995 and before January 1, 20072 | Clothes washers, other than household clothes washers | CSA C360-03 | CSA C360-03, Table 10 | On or after January 1, 2007 and before January 8, 2013
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a clothes washer described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Clothes washers manufactured on or after February 3, 1995 and before March 7, 2015 | CSA C360-03 | (a)size category;(b)capacity, in L, of clothes washer’s container;(c)annual energy consumption in kWh;(d)modified energy factor in L/kWh/cycle;(e)water consumption factor in L/cycle/L;(f)maximum wash temperature available, namely, ≤ 57.2°C or > 57.2°C;(g)the wash/rinse temperature selections listed in Table 5 of CSA C360-03 the product has;(h)water fill control system the product has, namely, manual or adaptive;(i)rotational axis of clothes washer’s container, namely, horizontal or vertical; and(j)method for payment the product has, if any.2 | Household clothes washers manufactured on or after March 7, 2015 | CSA C360-13 | (a)size category;(b)capacity, in L, of clothes washer’s container;(c)annual energy consumption in kWh;(d)integrated modified energy factor in L/kWh/cycle;(e)integrated water consumption factor in L/cycle/L;(f)maximum wash temperature available, namely, ≤ 57.2°C or > 57.2°C;(g)the wash/rinse temperature selections listed in Table 5 of the product has;(h)water fill control system the product has, namely, manual or adaptive; and(i)rotational axis of clothes washer’s container, namely, horizontal or vertical.
(a)a household appliance that consists of a clothes washer component and a clothes dryer component located above, below or beside it, that is powered by one power source and that has its control panel located on one of the components; or
(a)compact, if it has a clothes dryer component with a drum capacity of less than 125 L (4.4 cubic feet) and a clothes washer component with a basket capacity of less than 45 L (1.6 cubic feet); or
(b)standard, if it has a clothes dryer component with a drum capacity of 125 L (4.4 cubic feet) or more and a clothes washer component with a basket capacity of 45 L (1.6 cubic feet) or more.
(2)For the purposes of these Regulations, the size category of an integrated clothes washer-dryer that is a combination clothes washer is
For the purposes of these Regulations, an integrated clothes washer-dryer is one of the following types, namely, combination, over/under or side-by-side.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 30, an integrated clothes washer-dryer is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to integrated clothes washer-dryers that are manufactured during the periods set out in column 3.
(2)An integrated clothes washer-dryer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to an integrated clothes washer-dryer as defined in section 26. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C360-03 for clothes washer functionCSA C361-92 for clothes dryer function | CSA C360-03, Table 9, for clothes washer functionCSA C361-92, Table 8.1, for clothes dryer function | On or after February 3, 1995 and before January 1, 2007
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an integrated clothes washer-dryer described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Integrated clothes washer-dryers manufactured on or after February 3, 1995 and before March 7, 2015 | CSA C360-03 for clothes washer functionCSA C361-92 for clothes dryer function | (a)type and size category;(b)V;(c)annual energy consumption, in kWh, for clothes washer function and clothes dryer function;(d)modified energy factor in L/kWh/cycle for clothes washer function;(e)energy factor in kg/kWh for clothes dryer function;(f)water consumption factor in L/cycle/L;(g)maximum water temperature available, namely, ≤ 57.2°C or > 57.2°C;(h)which of the wash/rinse temperature selections listed in Table 5 of CSA C360-03 the product has;(i)water fill control system the product has, namely, manual or adaptive; and(j)drying controls the product has, namely, timed, auto-temp or auto-moisture.2 | Integrated clothes washer-dryers manufactured on or after March 7, 2015 | CSA C360-13 for clothes washer functionCSA C361-16 or for clothes dryer function | (a)type and size category;(b)V;(c)annual energy consumption, in kWh, for clothes washer function and clothes dryer function;(d)integrated modified energy factor in L/kWh/cycle for clothes washer function;(e)combined energy factor in kg/kWh for clothes dryer function;(f)integrated water consumption factor in L/cycle/L;(g)maximum water temperature available, namely, ≤ 57.2°C or > 57.2°C;(h)which of the wash/rinse temperature selections listed in Table 5 of the product has;(i)water fill control system the product has, namely, manual or adaptive; and(j)drying controls the product has, namely, timed, auto-temp or auto-moisture.
In respect of a dishwasher that is manufactured on or after January 1, 2010, a reference to “annual energy consumption” in Schedule 1 is to be read as a reference to “total annual energy consumption”.
(1)A dishwasher is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 37, a dishwasher is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
(1)The energy efficiency standards set out in column 3 of the table to this section apply to dishwashers described in column 1 that are manufactured during the periods set out in column 4.
(2)A dishwasher complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a dishwasher as defined in section 32. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Dishwashers | CSA C373-04 | CSA C373-04, Table 2 | On or after February 3, 1995 and before January 1, 20102 | Dishwashers that are standard | CSA C373-04 | Total annual energy consumption ≤ 355 kWh | On or after January 1, 2010 and before May 30, 20133 | [Repealed, SOR/2018-201, s. 11]4 | Dishwashers that are compact | | Total annual energy consumption ≤ 260 kWh | On or after January 1, 2010 and before May 30, 2013
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected and provided to the Minister in respect of a dishwasher described in column 1 and, if applicable, the information must be collected in accordance with the standard set out in column 2. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Dishwashers manufactured on or after February 3, 1995 and before January 1, 2010 | CSA C373-04, for information set out in paragraphs (b) to (d) | (a)type and size category;(b)volume, in L, of hot water used;(c)annual energy consumption in kWh;(d)energy factor in cycles/kWh; and(e)drying option the product has, namely, heat dry or heat on/heat off.2 | Dishwashers manufactured on or after January 1, 2010 and before May 30, 2013 | CSA C373-04, for information set out in paragraphs (b) to (e) | (a)type and size category;(b)volume, in L, of hot water used;(c)total annual energy consumption in kWh;(d)annual standby energy consumption in kWh;(e)energy factor in cycles/kWh; and(f)drying option the product has, namely,(i)power-dry with fan and heat on,(ii)power-dry with fan on and heat off, or(iii)power-dry off.3 | Dishwashers manufactured on or after May 30, 2013 | CSA C373-14, for information set out in paragraphs (b) to (d) and (f) | (a)type and size category;(b)volume, in L, of hot water used;(c)total annual energy consumption in kWh;(d)annual standby energy consumption in kWh;(e)drying option the product has, namely,(i)power-dry with fan and heat on,(ii)power-dry with fan on and heat off, or(iii)power-dry off; and(f)water consumption factor in L/cycle.
compressor-cycled automatic defrost system means a defrost system in which the defrosting action for the refrigerated spaces occurs using the natural warming of the evaporator and that is automatically initiated when the compressor is cycled on and automatically terminated when the compressor is cycled off. (dispositif de dégivrage automatique à cycle du compresseur)
For the purposes of these Regulations, the size category of a refrigerator or combination refrigerator-freezer is the capacity range set out below within which the actual size of the product falls or that is closest to the actual size of the product:
(1)Refrigerators and combination refrigerator-freezers are prescribed as energy-using products.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 43, a refrigerator or combination refrigerator-freezer is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
(1)The energy efficiency standards set out in column 3 of the table to this section apply to refrigerators and combination refrigerator-freezers described in column 1 that are manufactured during the periods set out in column 4.
(2)A refrigerator complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a refrigerator as defined in section 39.
(3)A combination refrigerator-freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a combination- freezer as defined in section 39.
For the purposes of these Regulations, the size category of a freezer is the capacity range set out below within which the actual size of the product falls or that is closest to the actual size of the product:
(1)A freezer is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 49, a freezer is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
(1)The energy efficiency standards set out in column 3 of the table to this section apply to freezers described in column 1 that are manufactured during the periods set out in column 4.
(2)A freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a freezer as defined in section 45.Item | Column 1 | Column 2 | Column 3 | Column 4Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Freezers | CSA C300-12 | CSA C300-12, Table 1 | On or after February 3, 1995 and before September 15, 20142 | Freezers | CSA C300-15 | CSA C300-15, Table 1 | On or after September 15, 2014
E means energy consumption, expressed in kilowatt hours per month. (E)
electric range means a householdelectric range. It does not include a portable range that is designed for an electrical supply of 120 V or a microwave oven. (cuisinière électrique)
modular cooking top means a cartridge that consists of at least one surface element and that can be plugged into a receptacle on the surface of an electric range. (table de cuisson modulaire)
For the purposes of these Regulations, the size category of an electric range that has at least one surface element and at least one oven is one of the following, based on the product’s exterior width:
(1)An electric range is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 55, an electric range is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to electric ranges described in column 1 that are manufactured during the periods set out in column 3.
(2)An electric range complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C358-03 that are applicable to an electric range as defined in section 51. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Energy Efficiency Standard | Period of Manufacture1 | Electric ranges that have at least one surface element and at least one oven | E ≤ 0.93 V + 14.3 | On or after February 3, 1995 and before August 1, 20032 | Electric ranges that have at least one surface element and at least one oven | CSA C358-03, clause 8(a) | On or after August 1, 20033 | Electric ranges that have at least one oven but no surface elements | E ≤ 38 | On or after February 3, 1995 and before August 1, 2003
For the purpose of subsection 5(1) of the Act, the information set out in column 2 of the table to this section must be collected in accordance with CSA C358-03 and provided to the Minister in respect of an electric range described in column 1. | Column 1 | Column 2Item | Energy-using Product | Information1 | Electric ranges that have at least one surface element and at least one oven and that were manufactured on or after February 3, 1995 and before August 1, 2003 | (a)type and size category;(b)volume, in L, of usable oven space;(c)annual energy consumption in kWh;(d)cooking top the product has, namely, conventional or modular; and(e)information that indicates whether product is free-standing or built-in.2 | Electric ranges that have at least one surface element and at least one oven and that are manufactured on or after August 1, 2003 | (a)type and size category;(b)volume, in L, of usable oven space;(c)annual energy consumption in kWh;(d)oven configuration, namely, single oven or double oven;(e)baking mode the product has, namely, normal bake or normal bake with forced convection;(f)information that indicates whether product is free-standing or built-in; and(g)annual clock energy consumption in kWh.3 | Electric ranges that have at least one oven but no surface element and that were manufactured on or after February 3, 1995 and before August 1, 2003 | (a)volume, in L, of usable oven space for each oven;(b)annual energy consumption in kWh;(c)oven configuration, namely, single oven, double oven or double oven with microwave upper oven; and(d)information that indicates whether product is built-in or wall-mounted.4 | Electric ranges that have at least one oven but no surface element and that are manufactured on or after August 1, 2003 | (a)type;(b)volume, in L, of usable oven space for each oven;(c)exterior oven width;(d)annual energy consumption in kWh;(e)oven configuration, namely, single oven, double oven or double oven with microwave upper oven;(f)baking mode the product has, namely, normal bake or normal bake with forced convection;(g)information that indicates whether product is built-in or wall-mounted; and(h)annual clock energy consumption in kWh.
In this Subdivision, gas range means a household propane or natural gas range that has an electrical power source, is used for food preparation and provides at least one of the following functions:
(1)A gas range is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 59, a gas range is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C358-03 and provided to the Minister in respect of a gas range:
(a)the volume of usable oven space, expressed in litres;
(b)information that indicates whether the product is built-in or free-standing; and
(c)the broiler configuration, namely, open or closed.
10 C.F.R. Appendix X1 means Appendix X1 to Subpart B of Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Dehumidifiers, as amended from time to time. (appendice X1 10 C.F.R.)
10 C.F.R. §430.32(v)(2) means the table to paragraph 430.32(v)(2) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(v)(2))
whole-home dehumidifier means a dehumidifier that is designed to be installed in an air duct. (déshumidificateur à conduit)
(1)The energy efficiency standards set out in column 3 of the table to this section apply to dehumidifiers described in column 1 that are manufactured during the periods set out in column 4.
(2)A dehumidifier complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a dehumidifier as defined in section 61. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Dehumidifiers | CSA C749-94 | CSA C749-94, clause 4.2 | On or after December 31, 1998 and before October 1, 20072 | Dehumidifiers | CSA C749-07 | CSA C749-07, Table 1 | On or after October 1, 2007 and before October 1, 2012
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a dehumidifier described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Dehumidifiers manufactured before October 1, 2007 | CSA C749-94 | (a)water removal capacity, in L/day; and(b)energy factor, in L/kWh.2 | Dehumidifiers manufactured on or after October 1, 2007 and before June 13, 2019 | CSA C749-07 | (a)water removal capacity, in L/day;(b)energy factor, in L/kWh; and(c)standby power, in watts.3 | Dehumidifiers manufactured on or after June 13, 2019 | 10 C.F.R. Appendix X1 | (a)if product is a portable dehumidifier, water removal capacity, in L/day;(b)if product is a whole-home dehumidifier, case volume in litres (cubic feet);(c)integrated energy factor, in L/kWh; and(d)standby power, in watts.
CEER means the combined energy efficiency ratio of the product, expressed in British thermal units per watt hour, that constitutes a single measure of its energy efficiency and that integrates standby mode and off mode energy use with on mode energy use. (CEER)
CSA C656-05 means the CSA standard CAN/CSA-C656-05 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-05)
CSA C656-14 means the CSA standard CSA-C656-14 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-14)
CSA C746-06 means the CSA standard CAN/CSA-C746-06 entitled Performance Standard for Rating Large and Single Packaged Vertical Air Conditioners and Heat Pumps. (CSA C746-06)
CSA C746-98 means the CSA standard CAN/CSA-C746-98 entitled Performance Standard for Rating Large Air Conditioners and Heat Pumps. (CSA C746-98)
(a)produces at least 300 Pa (1.2 inches of water) external static pressure when operated at an air volume rate of 104 to 165 L/s (220 to 350 cubic feet/minute) per nominal ton of cooling; and
(b)uses room outlets that produce velocities greater than 5 m/s (1,000 feet/minute) and that each have an area less than 39 cm2 (6 square inches). (à grand débit et à petits conduits)
(a)has a cooling capacity that is less than or equal to 8.79 kW (30,000 Btu/h); and
(b)has an outdoor or indoor unit
(i)that has an overall displacement that is — or two or more overall exterior dimensions that are — substantially smaller than those of other units of a similar cooling capacity that are usually installed in single-family homes, and
(ii)with respect to which an increase in the overall displacement or two or more overall exterior dimensions would result in a considerable increase in the usual cost of installation or in a significant loss in the utility of the product to the consumer. (
10 C.F.R. Appendix F1 means Appendix F1 to Subpart F, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Air-Cooled, Three-Phase, Small Commercial Package Air Conditioning and Heating Equipment With a Cooling Capacity of Less Than 65,000 Btu/h and Air-Cooled, Three-Phase, Variable Refrigerant Flow Multi-Split Air Conditioners and Heat Pumps With a Cooling Capacity of Less Than 65,000 Btu/h, as amended from time to time. (appendice F1 10 C.F.R.)
10 C.F.R. Appendix M means Appendix M to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M 10 C.F.R)
10 C.F.R. Appendix M1 means Appendix M1 to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M1 10 C.F.R.)
The following definitions apply in this Subdivision.
AHRI 340/360 means the AHRI standard ANSI/AHRI 340/360-2007 entitled Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment. (AHRI 340/360)
CSA C746-17 means the CSA standard CAN/CSA-C746-17 entitled Energy performance rating for large and single packaged vertical air conditioners and heat pumps. (
The following definitions apply in this Subdivision.
CSA C744-04 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2004/CAN/CSA-C744-04 entitled Standard for Packaged Terminal Air Conditioners and Heat Pumps. (CSA C744-04)
CSA C744-14 means the joint CSA and standard / 310/380-2014/CAN/-C744-14 entitled Standard for Packaged Terminal Air Conditioners and Heat Pumps. (
The following definitions apply in this Subdivision.
off mode power consumption means the power consumption when the unit is connected to mains power but is not providing cooling or heating. (consommation d’énergie en mode arrêt)
single package central air conditioner means a single-phase or three-phase central air conditioner that is a single package unit and that has a cooling capacity of less than 19 kW (65,000 Btu/h). It does not include a single package vertical air conditioner. (climatiseur central monobloc)
128Definition of single package vertical air conditioner#
In this Subdivision, single package vertical air conditioner means a single package commercial air conditioner, with or without heating capability, that has its major components arranged vertically, is air-cooled and encased and is intended for mounting through, or on either side of, an exterior wall. It does not include a single package commercial air conditioner that has reverse cycle refrigeration.
(1)A single package vertical air conditioner is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 130, a single package vertical air conditioner is not considered to be an energy-using product unless it is manufactured on or after January 1, 2011 and has a cooling capacity of less than 70 kW (240,000 Btu/h).
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with and provided to the Minister in respect of a single package vertical air conditioner:
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase split system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
(1.1)The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase split system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
(2)A split system central air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split system central air conditioner as defined in section 132. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Split system central air conditioners, other than those that are small-duct and high-velocity | for seasonal energy efficiency ratio10 C.F.R. Appendix M for | Seasonal energy efficiency ratio ≥ 13.0Off mode power consumption ≤ 30 W | On or after February 3, 1995 and before January 1, 2023
(1)A large condensing unit is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 138, a large condensing unit is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to large condensing units described in column 1.
(2)A large condensing unit complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C746-98 that are applicable to a large condensing unit as defined in section 136. | Column 1 | Column 2Item | Energy-using Product | Energy Efficiency Standard1 | Large condensing units that are cooled by air | Energy efficiency ratio ≥ 10.1
chiller means a machine, with or without an integral refrigerant condenser, that is designed to use a refrigerant cycle to remove heat from a liquid and to reject the heat to a cooling medium. (refroidisseur)
CSA C656-05 means the CSA standard CAN/CSA-C656-05 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-05)
CSA C656-14 means the CSA standard CAN/CSA-C656-14 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-14)
CSA C746-06 means the CSA standard CAN/CSA-C746-06 entitled Performance Standard for Rating Large and Single Packaged Vertical Air Conditioners and Heat Pumps. (CSA C746-06)
CSA C13256-1 means the CSA standard CAN/CSA-C13256-1-01 entitled Water-Source Heat Pumps — Testing and Rating for Performance — Part 1: Water-to-Air and Brine-to-Air Heat Pumps. (CSA C13256-1)
(a)produces at least 300 Pa (1.2 inches of water) external static pressure when operated at an air volume rate of 104 to 165 L/s (220 to 350 cubic feet/minute) per nominal ton of cooling; and
(b)uses room outlets that produce velocities greater than 5 m/s (1,000 feet/minute) and that each have an area less than 39 cm2 (6 square inches). (à grand débit et à petits conduits)
(a)has a cooling capacity that is less than or equal to 8.79 kW (30,000 Btu/h); and
(b)has an outdoor or indoor unit
(i)that has an overall displacement that is — or two or more overall exterior dimensions that are — substantially smaller than those of other units of a similar cooling capacity that are usually installed in single-family homes, and
(ii)with respect to which an increase in the overall displacement or two or more overall exterior dimensions would result in a considerable increase in the usual cost of installation or in a significant loss in the utility of the product to the consumer. (à espace restreint
10 C.F.R. Appendix F1 means Appendix F1 to Subpart F, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Air-Cooled, Three-Phase, Small Commercial Package Air Conditioning and Heating Equipment With a Cooling Capacity of Less Than 65,000 Btu/h and Air-Cooled, Three-Phase, Variable Refrigerant Flow Multi-Split Air Conditioners and Heat Pumps With a Cooling Capacity of Less Than 65,000 Btu/h, as amended from time to time. (appendice F1 10 C.F.R.)
10 C.F.R. Appendix M means Appendix M to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M 10 C.F.R.)
10 C.F.R. Appendix M1 means Appendix M1 to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M1 10 C.F.R.)
The following definitions apply in this Subdivision.
CSA C446-94 means the CSA standard CAN/CSA-C446-94 entitled Performance of Ground-Source Heat Pumps. (CSA C446-94)
ground-source heat pump means a single package or split-system heat pump that is factory-built, has a cooling or heating capacity of less than 40 kW (135,000 Btu/h) and is intended for application in an open- or closed-loop ground-source system. (
(1)An internal water loop heat pump is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 193, an internal water loop heat pump is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to internal water loop heat pumps described in column 1.
(2)An internal water loop heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C13256-1 that are applicable to an internal water loop heat pump as defined in section 191. | Column 1 | Column 2Item | Energy-using Product | Energy Efficiency Standard
The following definitions apply in this Subdivision.
AHRI 340/360 means the AHRI standard ANSI/AHRI 340/360-2007 entitled Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment. (AHRI 340/360)
CSA C746-17 means the CSA standard CAN/CSA-C746-17 entitled Energy performance rating for large and single packaged vertical air conditioners and heat pumps. (
The following definitions apply in this Subdivision.
CSA C744-04 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2004/CAN/CSA-C744-04 entitled Standard for Packaged Terminal Air Conditioners and Heat Pumps. (CSA C744-04)
CSA C744-17 means the joint CSA and standard / 310/380-2017/-C744-17 entitled Packaged terminal air conditioners and heat pumps. (
The following definitions apply in this Subdivision.
off mode power consumption means the power consumption when the unit is connected to mains power but is not providing cooling or heating. (consommation d’énergie en mode arrêt)
single package central heat pump means a single-phase or three-phase air-to-air central heat pump that is a single package unit and that has a cooling capacity of less than 19 kW (65,000 Btu/h), but does not include a single package vertical heat pump. (thermopompe centrale monobloc)
207Definition of single package vertical heat pump#
In this Subdivision, single package vertical heat pump means a single package commercial heat pump that is encased, that has its major components arranged vertically and that
(a)is air-cooled and uses reverse cycle refrigeration as its primary heat source; and
(b)is intended for mounting through, or on either side of, an exterior wall.
(1)A single package vertical heat pump is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 209, a single package vertical heat pump is not considered to be an energy-using product unless it is manufactured on or after January 1, 2011 and has a cooling capacity of less than 70 kW (240,000 Btu/h).
(1)A split system central heat pump is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 213, a split system central heat pump is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.
gas furnace means an automatic operating gas-fired central forced air furnace that uses propane or natural gas and has an input rate of not more than 117.23 kW (400,000 Btu/h). It does not include a furnace for a park model trailer or a recreational vehicle. (générateur d’air chaud à gaz)
gas furnace for relocatable buildings means a gas furnace that is intended for use in a temporary modular building that can be relocated from one site to another and is marked for use in relocatable buildings. (générateur d’air chaud à gaz pour bâtiments relocalisables)
manufactured home means a factory-built, single- or multiple-section, one-storey dwelling that
(a)is designed and constructed for year-round occupancy;
(b)is designed to be transported to its installation site; and
(c)is ready for occupancy when it is installed in accordance with the manufacturer’s installation instructions. (maison usinée)
(i)that has an overall displacement that is — or two or more overall exterior dimensions that are — substantially smaller than those of other units of a similar heating capacity that are usually installed in single-family homes, and
(ii)with respect to which an increase in the overall displacement or two or more overall exterior dimensions would result in a considerable increase in the usual cost of installation or in a significant loss in the utility of the product to the consumer. (à espace restreint)
through-the-wall means, with respect to a gas furnace, one that is designed and marketed to be installed in an opening in an exterior wall that is fitted with a weatherized sleeve. (mural)
(1)The energy efficiency standards set out in column 3 of the table to this section apply to gas furnaces described in column 1 that are manufactured during the periods set out in column 4.
(2)A gas furnace complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a gas furnace as defined in section 257. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and use single-phase electric current | CSA 2.3 | Annual fuel utilization efficiency ≥ 78% | On or after February 3, 1995 and before December 31, 20092 | Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and do not have an integrated cooling component | CSA P.2 | Annual fuel utilization efficiency ≥ 90% | On or after December 31, 2009 and before July 3, 2019
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas furnace described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured before December 31, 2009 | CSA 2.3 | (a)heating capacity, in kW (Btu/h); and(b)annual fuel utilization efficiency.2 | Gas furnaces, other than those that are through-the-wall, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured on or after December 31, 2009 and before July 3, 2019 | CSA P.2 | (a)maximum heat input and output nominal capacities, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)information that indicates whether product has an integrated cooling component;(d)if product has an integrated cooling component, information that indicates whether the product is outdoor or ;(e)standby power, in W;(f)power burner’s PE and VPE; and(g)type of fuel used.
The following definitions apply in this Subdivision.
CSA B212 means the CSA standard CSA-B212-93 entitled Seasonal Energy Utilization Efficiencies of Oil-Fired Furnaces and Boilers. (CSA B212)
oil-fired furnace means a warm-air furnace, other than a furnace for a mobile home or for a recreational vehicle, that has an input rate of not more than 65.92 kW (225,000 Btu/h) and that is either
The following definitions apply in this Subdivision.
CSA P.11 means the CSA standard CAN/CSA-P.11-07 entitled Testing Method for Measuring Efficiency and Energy Consumption of Gas-fired Unit Heaters. (CSA P.11)
gas-fired unit heater means a self-contained, automatically controlled, vented, gas-burning appliance that distributes warmed air without the use of ducts and that has an input rate of not more than 2 931 kW (10,000,000 Btu/h). (aérotherme à gaz)
ASHRAE 103 means the ANSI/ASHRAE standard 103-2007 entitled Method of Testing for Annual Fuel Utilization Efficiency of Residential Central Furnaces and Boilers. (ASHRAE 103)
(a)adjusts the temperature of the water supplied by a boiler to ensure that an incremental change in inferred heat load produces a corresponding incremental change in the temperature of the water supplied or, if the boiler fires at a single input rate, automatically allows the burner or heating element to fire only when the device has determined that the inferred heat load cannot be met by the residual heat of the water in the system; and
(b)when there is no inferred heat load, limits the water temperature in the boiler to not more than 60°C. (dispositif automatique de réglage de la température de l’eau)
CSA P.2 means the CSA standard CAN/CSA-P.2-13 entitled Testing Method for Measuring the Annual Fuel Utilization Efficiency of Residential Gas-Fired or Oil-Fired Furnaces and Boilers. (CSA P.2)
10 C.F.R. Appendix A means Appendix A to Subpart E, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Thermal Efficiency and Combustion Efficiency of Commercial Packaged Boilers, as amended from time to time. (appendice A 10 C.F.R.)
The following definitions apply in this Subdivision.
CGA P.2 means the CGA standard CGA P.2-1991 entitled Testing Method for Measuring Annual Fuel Utilization Efficiencies of Residential Furnaces and Boilers. (CGA P.2)
The following definitions apply in this Subdivision.
CSA B212 means the CSA standard CSA-B212-93 entitled Seasonal Energy Utilization Efficiencies of Oil-Fired Furnaces and Boilers. (CSA B212)
oil-fired boiler means a boiler that is intended for application in a low pressure steam, or hot water, central heating system, has an input rate of less than 2 930.71 kW (10,000,000 Btu/h) and is
In this Subdivision, electric boiler means a boiler that uses electric energy as a source of heat, is intended for application in a hot water central heating system, has an input rate of less than 88 kW (300,000 Btu/h) and is not equipped with tankless domestic water heating coils.
(1)An electric boiler is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 325, an electric boiler is not considered to be an energy-using product unless it is manufactured on or after September 1, 2012.
The energy efficiency standard that applies to an electric boiler is that it must be equipped with an automatic water temperature adjustment device without which the boiler is not operable.
The following definitions apply in this Subdivision.
CSA P.3-04 means the CSA standard CAN/CSA-P.3-04 entitled Testing Method for Measuring Energy Consumption and Determining Efficiencies of Gas-Fired Storage Water Heaters. (CSA P.3-04)
ANSI C78.79 means the ANSI standard ANSI C78.79-2014 entitled American National Standard for Electric Lamps — Nomenclature for Envelope Shapes Intended for Use with Electric Lamps. (ANSI C78.79)
ANSI C81.61 means the ANSI standard ANSI C81.61-2016 entitled American National Standard for Electrical Lamp Bases — Specifications for Bases (Caps) for Electric Lamps. (ANSI C81.61)
colour rendering index means the measured degree of colour shift that objects undergo when they are illuminated by a light source as compared with the colour of those same objects when they are illuminated by a reference source of comparable colour temperature. (indice de rendu des couleurs)
former Regulations means these Regulations as they read immediately before the day on which subsection 1(2) of the Regulations Amending the Energy Efficiency Regulations, 2016 (Amendment 18) comes into force. (règlement antérieur)
IES Handbook means the IES publication entitled Lighting Handbook, 9th edition. (Manuel IES)
IES LM16 means the IES standard IES LM-16-1993 entitled Practical Guide to Colorimetry of Light Sources. (IES LM16)
lamp efficacy means the number of lumens per watt determined by
(a)dividing a lamp’s luminous flux by its power, measured under equilibrium conditions at the time of determining the luminous flux; and
(b)in the case of a general service incandescent reflector lamp, rounding the number calculated under paragraph (a) to the nearest half number. (efficacité lumineuse)
plant lamp means a lamp that is designed and marketed for plant growing applications and that emits its highest radiant power peaks in the range of 440 to 490 nm, 620 to 740 nm or both of these ranges of the electromagnetic spectrum. (lampe pour horticulture)
(1)The principal display panel of the product’s package must display the following information in the following order:
(a)the words “Light output” and “Flux lumineux”, followed by the numerical value of the product’s luminous flux and the word “lumens”;
(b)the words “Efficacy” and “Efficacité”, followed by the numerical value of the product’s nominal efficacy and the words “lumens/watt”;
(c)the words “Power” and “Puissance”, followed by the numerical value of the product’s nominal power consumption and the word “watts”;
(d)the words “Life” and “Durée de vie”, followed by the numerical value of the product’s life and the words “hours” and “heures”, respectively; and
(e)the words “Light appearance” and “Apparence de la lumière”, followed by the numerical value of the product’s correlated colour temperature and the upper case letter “K” or the word “Kelvin”.
(2)The words “Light output”, “Flux lumineux”, “Efficacy”, “Efficacité”, “Power”, “Puissance”, “Life”, “Durée de vie”, “Light appearance” and “Apparence de la lumière” must be in the same font and be equal in size.
The following definitions apply in this Subdivision.
10 C.F.R. Appendix R means Appendix R to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring Average Lamp Efficacy (LE), Color Rendering Index (CRI), and Correlated Color Temperature (CCT) of Electric Lamps, as amended from time to time. (appendice R 10 C.F.R.)
10 C.F.R. §430.32(n)(4) means the table to paragraph 430.32(n)(4) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(n)(4)
(1)A fluorescent lamp ballast is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 451, a fluorescent lamp ballast is not considered to be an energy-using product if
(a)it was manufactured before February 3, 1995; or
(b)it was manufactured on or after February 3, 1995 and before November 14, 2014 and
(i)is a T12 dimming ballast,
(ii)is designed to operate a fluorescent lamp other than an F32T8, F34T12, F40T10 or F40T12 rapid-start fluorescent lamp or an F96T12ES, F96T12IS, F96T12HO or F96T12HO ES fluorescent lamp, or
(iii)is designed to be used in an outdoor sign and to operate two F96T12HO fluorescent lamps in ambient temperatures at or below –28.9°C.
pin-based means, with respect to a socket of a ceiling fan or ceiling fan light kit, one that is designed to hold a fluorescent lamp that is not integrally ballasted and that has a plug-in lamp base. It does not include a GU-24 socket. (à broche)
torchiere means a portable luminaire that has a reflector bowl or similar-shaped reflector that directs light in a predominantly upward direction for the purpose of providing indirect lighting and that may be equipped with one or more additional sockets intended for other lighting functions. (torchère)
(1)A ceiling fan light kit is prescribed as an energy-using product.
(2)However, a ceiling fan light kit is not considered to be an energy-using product
(a)for the purposes of sections 4 and 5, if it was manufactured before January 1, 2010; and
(b)for the purpose of section 517,
(i)if it was manufactured before January 1, 2010,
(ii)if it is manufactured on or after January 1, 2010 and before January 7, 2019, it has a total power less than or equal to 10 W or only pin-based sockets, or
The following definitions apply in this Subdivision.
CSA C860 means the CSA standard CAN/CSA C860-11 entitled Performance of Internally Lighted Exit Signs. (CSA C860)
exit sign has the same meaning as in CSA C860. It does not include an exit sign that flashes or that is photoluminescent or radioluminescent. (enseigne de sortie)
(b)provide drivers with movement information by means of a red or green traffic signal indicator that has a nominal diameter of 200 mm (8 inches) or 300 mm (12 inches). (module de signalisation routière)
VTCSH Arrow means the Institute of Transportation Engineers standard entitled Vehicle Traffic Control Signal Heads: Light Emitting Diode (LED) Vehicle Arrow Traffic Signal Supplement, dated July 1, 2007. (VTCSH Arrow)
VTCSH Circular means the Institute of Transportation Engineers standard entitled Vehicle Traffic Control Signal Heads: Light Emitting Diode (LED) Circular Signal Supplement, dated June 27, 2005. (
(b)to provide pedestrians with movement information by means of a walking person display or a hand display but not by means of a countdown message. (module de signalisation piétonnière)
PTCSI means the Institute of Transportation Engineers standard entitled Pedestrian Traffic Control Signal Indicators: Light Emitting Diode (LED) Signal Modules, dated August 4, 2010. (PTCSI
information display means a clock or other device that provides visual alphanumeric or graphical information or indicates the status of the equipment. (affichage)
The following definitions apply in this Subdivision.
compact audio product means a product that consists of an amplifier and a terrestrial tuner that are encased in a single housing — including a product that can produce sound from another media — and that uses mains power as at least one source of power and has attached or separable speakers. (produit audio compact)
off mode means the mode in which the product, while connected to mains power, cannot produce sound or provide any mechanical function and cannot be switched into another mode except by means of a manual switch on the product. (
The following definitions apply in this Subdivision.
off mode means the mode in which the product, while connected to mains power, cannot provide any mechanical function and cannot be switched into another mode with a remote control unit, a timer or another internal or external signal. (mode arrêt)
The following definitions apply in this Subdivision.
off mode means the mode in which the product, while connected to mains power, cannot produce either sound or picture or provide any mechanical function and cannot be switched into another mode with a remote control unit, a timer or another internal or external signal. (mode arrêt)
(1)The following definitions apply in this Subdivision.
adaptive external power supply means an external power supply that, without user intervention and while it is connected to mains power and each output is connected to a load, can alter the output voltage using a digital communication protocol with the end-use product. (
The following definitions apply in this Subdivision.
AV means, in respect of a commercial refrigerator-freezer, its adjusted volume in litres, which is the sum of the refrigerator volume and 1.63 times the freezer volume. (VC)
commercial freezer means a freezer that is self-contained or remote-condensing, that uses or is designed to be used with a vapour-compression refrigeration system and whose compartments are all designed for the freezing and display or storage of food, beverages or ice at temperatures below 0°C. It does not include a household freezer or walk-in freezer. (congélateur commercial)
commercial refrigerator means a refrigerator that is self-contained or remote-condensing, that uses or is designed to be used with a vapour-compression refrigeration system and whose compartments are all designed for the display or storage of food, beverages or flowers at temperatures at or above 0°C. It does not include a householdrefrigerator, refrigerated buffet table, refrigerated preparation table or walk-in cooler. (réfrigérateur commercial)
commercial refrigerator-freezer means a refrigerator-freezer that is self-contained or remote-condensing, that uses or is designed to be used with a vapour-compression refrigeration system and that has two or more compartments, at least one of which is designed for the display or storage of food and beverages at temperatures at or above 0°C and at least one of which is designed for the freezing and display or storage of food and beverages at temperatures below 0°C. It does not include a householdrefrigerator-freezer, walk-in freezer or walk-in cooler. (réfrigérateur-congélateur commercial)
CSA C657 means the CSA standard CSA C657-2015 entitled Energy Performance Standard for Commercial Refrigeration Equipment. (CSA C657)
ice cream freezer means a commercial freezer that is designed to operate at temperatures at or below –21°C ± 1.1°C and that is designed or marketed for the storage, display or dispensing of ice cream. (congélateur de crème glacée)
pull-down temperature reduction capability means the capability of a commercial refrigerator, when it is situated in an area that has an ambient temperature of 32.22˚C and when it is fully loaded with 355 mL beverage cans that are at a temperature of 32.22˚C at the time of loading, to cool those cans to an average stable temperature of 3.33˚C in 12 hours or less. (capacité d’abaisser la température)
TDA means the total display area of a product, expressed in square metres. (TDA)
The following definitions apply in this Subdivision.
ASHRAE 32.1 means the ASHRAE standard 32.1-2010 entitled Methods of Testing for Rating Vending Machines for Bottled, Canned, and Other Sealed Beverages. (ASHRAE 32.1)
combination vending machine means a refrigerated beverage vending machine containing two or more compartments separated by a solid partition — whether or not they share a product delivery chute — in which at least one compartment is designed to be refrigerated and has temperature controls; and at least one compartment is not designed to be refrigerated and does not contain temperature controls. (
CSA C802.2 means the CSA standard CAN/CSA-C802.2-00 entitled Minimum Efficiency Values for Dry-Type Transformers. (CSA C802.2)
CSA C802.2-12 means the CSA standard CAN/CSA-C802.2-12 entitled Minimum efficiency values for dry-type transformers. (CSA C802.2-12)
dry-type transformer means a transformer whose core and windings are in a gaseous or dry compound insulating medium and that is either single-phase with a nominal power of 15 to 833 kVA or three-phase with a nominal power of 15 to 7 500 kVA, has a nominal frequency of 60 Hz and has a high voltage winding of 35 kV or less. It does not include any of the following:
(a)an autotransformer;
(b)a drive (isolation) transformer that has two or more output windings or a nominal low-voltage line current of more than 1 500 A;
(n)a transformer that is in a voltage class greater than 1.2 kV and that has a BIL of less than 20 kV or more than 199 kV. (transformateur à sec)
10 C.F.R. Appendix A means Appendix A to Subpart K, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Distribution Transformers, as amended from time to time. (appendice A 10 C.F.R.)
transformer means a static-electric device that consists of two or more coils of insulated wire, together with the necessary accessories, and that transfers alternating current by electromagnetic induction from one coil to another to change the original voltage. (transformateur)
(2)However, a dry-type transformer is not considered to be an energy-using product
705Energy efficiency standards — manufactured before January 1, 2016#
(1)In respect of dry-type transformers that were manufactured on or after January 1, 2005 and before January 1, 2016, the energy efficiency standards set out in column 2 of the table to this section apply to dry-type transformers that were manufactured during the periods set out in column 3.
(2)A dry-type transformer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard referred to in column 1 that are applicable to a dry-type transformer as defined in section 703.
note
3 | Clothes washers, other than household clothes washers | CSA C360-03 | CSA C360-13, Table 11 | On or after January 8, 2013 and before January 1, 2018
4 | Clothes washers that are top-loaded, other than household clothes washers | CSA C360-13 | Modified energy factor ≥ 38.23 L/kWh/cycleIntegrated water consumption factor ≤ 1.18 L/cycle/L | On or after January 1, 2018
5 | Clothes washers that are front-loaded, other than household clothes washers | CSA C360-13 | Modified energy factor ≥ 56.63 L/kWh/cycleIntegrated water consumption factor ≤ 0.55 L/cycle/L | On or after January 1, 2018
3 | Clothes washers, other than household clothes washers, manufactured on or after March 7, 2015 and before January 1, 2018 | CSA C360-03 | (a)size category;(b)capacity, in L, of clothes washer’s container;(c)annual energy consumption in kWh;(d)modified energy factor in L/kWh/cycle;(e)water consumption factor in L/cycle/L;(f)maximum wash temperature available, namely, ≤ 57.2°C or > 57.2°C;(g)the wash/rinse temperature selections listed in Table 5 of CSA C360-03 the product has;(h)water fill control system the product has, namely, manual or adaptive;(i)rotational axis of clothes washer’s container, namely, horizontal or vertical; and(j)method for payment the product has, if any.
4 | Clothes washers, other than household clothes washers, manufactured on or after January 1, 2018 | CSA C360-13 | (a)size category;(b)capacity, in L, of clothes washer’s container;(c)annual energy consumption in kWh;(d)modified energy factor in L/kWh/cycle;(e)integrated water consumption factor in L/cycle/L;(f)maximum wash temperature available, namely, ≤ 57.2°C or > 57.2°C;(g)the wash/rinse temperature selections listed in Table 5 of CSA C360-13 the product has;(h)water fill control system the product has, namely, manual or adaptive;(i)rotational axis of clothes washer’s container, namely, horizontal or vertical; and(j)method for payment the product has, if any.note
(a)compact, if it has a drum capacity of less than 45 L (1.6 cubic feet); or
(b)standard, if it has a drum capacity of 45 L (1.6 cubic feet) or more.
2 | CSA C360-03 for clothes washer functionCSA C361-92 for clothes dryer function | CSA C360-03, Table 10, for clothes washer functionCSA C361-92, Table 8.1, for clothes dryer function | On or after January 1, 2007 and before March 7, 2015
3 | CSA C360-13 for clothes washer functionCSA C361-16 or 10 C.F.R. Appendix D2 for clothes dryer function | CSA C360-13, Table 9, for clothes washer functionCSA C361-16, Table 1, for clothes dryer function | On or after March 7, 2015 and before January 1, 2018
4 | CSA C360-13 for clothes washer functionCSA C361-16 or 10 C.F.R. Appendix D2 for clothes dryer function | CSA C360-13, Table 10, for clothes washer functionCSA C361-16, Table 1, for clothes dryer function | On or after January 1, 2018
Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture
1 | Refrigerators and combination refrigerator-freezers | CSA C300-12 | CSA C300-12, Table 1 | On or after February 3, 1995 and before September 15, 2014
(2)The information must be collected in accordance with one of the following standards:
(a)CSA C300-12, if the product was manufactured on or after February 3, 1995 and before September 15, 2014; or
(b)CSA C300-15, if the product is manufactured on or after September 15, 2014.
(c)[Repealed, SOR/2019-163, s. 7] (repealed)
note
(b)CSA C300-15, if the product is manufactured on or after September 15, 2014.
(c)[Repealed, SOR/2019-163, s. 12] (repealed)
4 | Electric ranges that have at least one oven but no surface elements | CSA C358-03, clause 8(c) | On or after August 1, 2003
5 | Electric ranges that are counter-mounted and have at least one surface element on a conventional cooking top but have no oven | E ≤ 34 | On or after February 3, 1995 and before August 1, 2003
6 | Electric ranges that are counter-mounted and have at least one surface element on a modular cooking top but have no oven | E ≤ 43 | On or after February 3, 1995 and before August 1, 2003
7 | Electric ranges that are counter-mounted and have at least one surface element but have no oven | CSA C358-03, clause 8(b) | On or after August 1, 2003
5 | Electric ranges that are counter-mounted, have at least one surface element but no oven and were manufactured on or after February 3, 1995 and before August 1, 2003 | (a)annual energy consumption in kWh; and(b)cooking top configuration, namely, conventional or modular.
6 | Electric ranges that are counter-mounted, have at least one surface element but no oven and are manufactured on or after August 1, 2003 | (a)annual energy consumption in kWh;(b)exterior oven width; and(c)annual clock energy consumption in kWh.
3 | Dehumidifiers | CSA C749-07 | CSA C749-07, Table 1B | On or after October 1, 2012 and before June 13, 2019
4 | Portable dehumidifiers | 10 C.F.R. Appendix X1 | Minimum integrated energy factor applicable, based on product’s capacity, as set out in 10 C.F.R. §430.32(v)(2) | On or after June 13, 2019
5 | Whole-home dehumidifiers | 10 C.F.R. Appendix X1 | Minimum integrated energy factor applicable, based on product’s case volume, as set out in 10 C.F.R. §430.32(v)(2) | On or after June 13, 2019
TSD D2SA001 means the technical standards document D2SA001 published by the Minister and entitled Testing Standard and Energy Efficiency Standards for Room Air Conditioners. (DNT D2SA001)
(2)However, for the purposes of sections 4, 5, 112, 114 and 115, a room air conditioner is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard or provision set out in column 2 and provided to the Minister in respect of a room air conditioner described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Room air conditioners manufactured before June 1, 2014 | CSA C368.1, for information set out in paragraphs (b) to (d) | (a)type;(b)power input;(c)cooling capacity, in kW (Btu/h); and(d)energy efficiency ratio.2 | Room air conditioners manufactured on or after June 1, 2014 | Part 1 of TSD D2SA001, for information set out in paragraphs (b) and (c) | (a)type;(b)cooling capacity, in kW (Btu/h); and(c)the product’s CEER.note
IEER means the integrated energy efficiency ratio, expressed in British thermal units per watt hour, that constitutes a single number cooling part-load efficiency metric of a large air conditioner. (IEER)
large air conditioner means a commercial or industrial unitary air conditioner with a cooling capacity of at least 19 kW (65,000 Btu/h) but less than 223 kW (760,000 Btu/h). It does not include a single package vertical air conditioner. (climatiseur de grande puissance)
10 C.F.R. Appendix A means Appendix A to Subpart F, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Air-Cooled Small (≥65,000 Btu/h), Large, and Very Large Commercial Package Air Conditioning and Heating Equipment, as amended from time to time. (appendice A 10 C.F.R.)
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to large air conditioners that are cooled by air and described in column 1 and that are manufactured during the period set out in column 4.
(2)The energy efficiency standards set out in column 3 of Table 2 to this section apply to large air conditioners that are cooled by water and described in column 1 and that are manufactured during the period set out in column 4.
(2.1)The energy efficiency standards set out in column 3 of Table 3 to this section apply to large air conditioners that are cooled by evaporation and described in column 1 and that are manufactured during the period set out in column 4.
(3)A large air conditioner complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a large air conditioner as defined in section 116. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 10.3 | On or after December 31, 1998 and before January 1, 20102 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.2IEER ≥ 11.4 | On or after January 1, 2010 and before January 1, 20183 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.2IEER ≥ 12.9 | On or after January 1, 2018 and before January 1, 20264 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 11.2IEER ≥ 14.8 | On or after January 1, 20265 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 9.7 | On or after December 31, 1998 and before January 1, 20106 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0IEER ≥ 11.2 | On or after January 1, 2010 and before January 1, 20187 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.0IEER ≥ 12.4 | On or after January 1, 2018 and before January 1, 20268 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 11.0IEER ≥ 14.2 | On or after January 1, 20269 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.0IEER ≥ 10.1 | On or after January 1, 2010 and before January 1, 201810 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 10.0IEER ≥ 11.6 | On or after January 1, 2018 and before January 1, 202611 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.0IEER ≥ 13.2 | On or after January 1, 202612 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 10.1 | On or after December 31, 1998 and before January 1, 201013 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0IEER ≥ 11.2 | On or after January 1, 2010 and before January 1, 201814 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.0IEER ≥ 12.7 | On or after January 1, 2018 and before January 1, 202615 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 11.0IEER ≥ 14.6 | On or after January 1, 202616 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 9.5 | On or after December 31, 1998 and before January 1, 201017 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8IEER ≥ 11.0 | On or after January 1, 2010 and before January 1, 201818 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 10.8IEER ≥ 12.2 | On or after January 1, 2018 and before January 1, 202619 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.8IEER ≥ 14.0 | On or after January 1, 202620 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 9.8IEER ≥ 9.9 | On or after January 1, 2010 and before January 1, 201821 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 9.8IEER ≥ 11.4 | On or after January 1, 2018 and before January 1, 202622 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 9.8IEER ≥ 13.0 | On or after January 1, 2026 | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 11.5 | On or after December 31, 1998 and before January 1, 20102 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.5IEER ≥ 11.7 | On or after January 1, 2010 and before January 1, 20183 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.1IEER ≥ 11.7 | On or after January 1, 20184 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 11.0 | On or after December 31, 1998 and before January 1, 20105 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0IEER ≥ 11.2 | On or after January 1, 2010 and before January 1, 20186 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.5IEER ≥ 11.2 | On or after January 1, 20187 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 11.3 | On or after December 31, 1998 and before January 1, 20108 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.3IEER ≥ 11.5 | On or after January 1, 2010 and before January 1, 20189 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.9IEER ≥ 11.5 | On or after January 1, 201810 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 10.8 | On or after December 31, 1998 and before January 1, 201011 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8IEER ≥ 11.0 | On or after January 1, 2010 and before January 1, 201812 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.3IEER ≥ 11.0 | On or after January 1, 201813 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0IEER ≥ 11.1 | On or after January 1, 2010 and before January 1, 201814 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.4IEER ≥ 11.1 | On or after January 1, 201815 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8IEER ≥ 10.9 | On or after January 1, 2010 and before January 1, 201816 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.2IEER ≥ 10.9 | On or after January 1, 2018 | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 11.5 | On or after December 31, 1998 and before January 1, 20102 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.5IEER ≥ 11.7 | On or after January 1, 2010 and before January 1, 20183 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.1IEER ≥ 11.7 | On or after January 1, 20184 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 11.0 | On or after December 31, 1998 and before January 1, 20105 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0IEER ≥ 11.2 | On or after January 1, 2010 and before January 1, 20186 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.0IEER ≥ 11.2 | On or after January 1, 20187 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 11.3 | On or after December 31, 1998 and before January 1, 20108 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.3IEER ≥ 11.5 | On or after January 1, 2010 and before January 1, 20189 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.9IEER ≥ 11.5 | On or after January 1, 201810 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 10.8 | On or after December 31, 1998 and before January 1, 201011 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8IEER ≥ 11.0 | On or after January 1, 2010 and before January 1, 201812 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.8IEER ≥ 11.0 | On or after January 1, 201813 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0IEER ≥ 11.1 | On or after January 1, 2010 and before January 1, 201814 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.9IEER ≥ 11.1 | On or after January 1, 201815 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8IEER ≥ 10.9 | On or after January 1, 2010 and before January 1, 201816 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.7IEER ≥ 10.9 | On or after January 1, 2018
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a large air conditioner described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Large air conditioners manufactured on or after December 31, 1998 and before January 1, 2010 | CSA C746-98 | (a)product classification set out in Column II of Table 1 of CSA C746-98;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio; and(d)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric.2 | Large air conditioners manufactured on or after January 1, 2010 and before January 1, 2018 | CSA C746-06AHRI 340/360 for IEER | (a)product classification set out in Column II of Table 1 of CSA C746-06;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)IEER; and(e)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric.3 | Large air conditioners manufactured on or after January 1, 2018 and before January 1, 2026 | CSA C746-17 | (a)product classification set out in Column II of Table 1 of CSA C746-17;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)IEER; and(e)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric.4 | Large air conditioners manufactured on or after January 1, 2026 | CSA C746-17 or 10 C.F.R. Appendix A | (a)product classification set out in Column II of Table 1 of CSA C746-17;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)IEER; and(e)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric.note
CSA C744-17 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2017/CAN/CSA-C744-17 entitled Packaged terminal air-conditioners and heat pumps. (CSA C744-17 )
(a)consists of a wall sleeve and a separate unencased cooling component and is intended to cool a single room or zone; or
(b)consists of a wall sleeve and a separate unencased combination of heating and cooling components and is intended to heat and cool a single room or zone. (climatiseur terminal autonome)
(2)However, for the purposes of sections 4, 5 and 122, a packaged terminal air conditioner is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to packaged terminal air conditioners that are manufactured during the periods set out in column 3.
(2)A packaged terminal air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a packaged terminal air conditioner as defined in section 120. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C744-04 | CSA C744-04, Table 2 | On or after December 31, 1998 and before September 30, 20122 | CSA C744-14 | CSA C744-14, Table 2 | On or after September 30, 2012 and before January 1, 20173 | CSA C744-17 | CSA C744-17, Table 2 | On or after January 1, 2017
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a packaged terminal air conditioner:
(a)its cooling capacity, expressed in kilowatts (British thermal units per hour);
(b)its energy efficiency ratio; and
(c)if applicable, identification of the product as a replacement unit.
(2)The information must be collected in accordance with
(a)CSA C744-04, if the product was manufactured on or after December 31, 1998 and before September 30, 2012;
(b)CSA C744-14, if the product was manufactured on or after September 30, 2012 and before January 1, 2017; or
(c)CSA C744-17, if the product is manufactured on or after January 1, 2017.
means, in respect of a single package central air conditioner, one that has a cooling capacity less than or equal to 8.79 kW (30,000 Btu/h), is designed to be installed through an exterior wall and is manufactured prior to January 1, 2023. (
(2)However, for the purposes of sections 4, 5 and 126, a single package central air conditioner is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase single package central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
(1.1)The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase single package central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
(2)A single package central air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a single package central air conditioner as defined in section 124. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Single package central air conditioners, other than those that are through-the-wall or small-duct and high-velocity | CSA C656-14 for seasonal energy efficiency ratio10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 14.0Off mode power consumption ≤ 30 W | On or after February 3, 1995 and before January 1, 20232 | Single package central air conditioners that are through-the-wall | CSA C656-05 for seasonal energy efficiency ratio10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 12.0Off mode power consumption ≤ 30 W | On or after February 3, 1995 and before January 1, 20233 | Single package central air conditioners that are small-duct and high-velocity | CSA C656-14 for seasonal energy efficiency ratio10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 12.0Off mode power consumption ≤ 30 W | On or after February 3, 1995 and before January 1, 20234 | Single package central air conditioners, other than those that are space-constrained | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 13.4Off mode power consumption ≤ 30 W | On or after January 1, 20235 | Single package central air conditioners that are space-constrained | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 11.7Off mode power consumption ≤ 30 W | On or after January 1, 2023 | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Single package central air conditioners, other than those that are through-the-wall, or small-duct and high-velocity | CSA C656-14 | Seasonal energy efficiency ratio ≥ 14.0 | On or after February 3, 1995 and before January 1, 20232 | Single package central air conditioners, other than those that are space-constrained | CSA C656-14 | Seasonal energy efficiency ratio ≥ 14.0 | On or after January 1, 2023 and before January 1, 20263 | Single package central air conditioners, other than those that are space-constrained | 10 C.F.R. Appendix F1 | Seasonal energy efficiency ratio 2 ≥ 13.4 | On or after January 1, 20264 | Single package central air conditioners that are through-the-wall | CSA C656-05 | Seasonal energy efficiency ratio ≥ 12.0 | On or after February 3, 1995 and before January 1, 20235 | Single package central air conditioners that are space-constrained | CSA C656-14 | Seasonal energy efficiency ratio ≥ 12.0 | On or after January 1, 2023 and before January 1, 20266 | Single package central air conditioners that are space-constrained | 10 C.F.R. Appendix F1 | Seasonal energy efficiency ratio 2 ≥ 13.9 | On or after January 1, 20267 | Single package central air conditioners that are small-duct and high-velocity | CSA C656-14 | Seasonal energy efficiency ratio ≥ 12.0 | On or after January 1, 2017 and before January 1, 2023
2 | Split system central air conditioners that are small-duct and high-velocity | CSA C656-14 for seasonal energy efficiency ratio10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 12.0Off mode power consumption ≤ 30 W | On or after February 3, 1995 and before January 1, 2023
4 | Split system central air conditioners that are small-duct and high-velocity | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 12.0Off mode power consumption ≤ 30 W | On or after January 1, 2023
5 | Split system central air conditioners that are space-constrained | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 11.7Off mode power consumption ≤ 30 W | On or after January 1, 2023
| Column 1 | Column 2 | Column 3 | Column 4
Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture
1 | Split system central air conditioners, other than those that are small-duct and high-velocity | CSA C656-14 | Seasonal energy efficiency ratio ≥ 13.0 | On or after February 3, 1995 and before January 1, 2026
3 | Split system central air conditioners that are small-duct and high-velocity | CSA C656-14 | Seasonal energy efficiency ratio ≥ 12.0 | On or after February 3, 1995 and before January 1, 2026
5 | Split system central air conditioners that are space-constrained | 10 C.F.R. Appendix F1 | Seasonal energy efficiency ratio 2 ≥ 12.7 | On or after January 1, 2026
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected and provided to the Minister in respect of a split system central air conditioner described in column 1 and, if applicable, the information must be collected in accordance with the standard set out in column 2. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Split system central air conditioners that are single-phase and manufactured on or after February 3, 1995 and before January 1, 2023 | CSA C656-14 for information set out in paragraphs (a) to (c)10 C.F.R. Appendix M for off mode power consumption | (a)product classification set out in column II of Table 1 to CSA C656-14;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio;(d)off mode power consumption, in watts; and(e)phase of electric current.2 | Split system central air conditioners that are three-phase and manufactured on or after February 3, 1995 and before January 1, 2026 | CSA C656-14 for information set out in paragraphs (a) to (c) | (a)product classification set out in column II of Table 1 to CSA C656-14;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio; and(d)phase of electric current.2.1 | Split system central air conditioners that are three-phase and manufactured on or after January 1, 2026 | 10 C.F.R. Appendix F1 for information set out in paragraphs (b) and (c) | (a)type;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio 2; and(d)phase of electric current.3 | Split system central air conditioners that are single-phase and manufactured on or after January 1, 2023 | 10 C.F.R. Appendix M1 for information set out in paragraphs (b) to (d) | (a)type;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio 2;(d)off mode power consumption, in watts; and(e)phase of electric current.note
2 | Large condensing units that are cooled by water or evaporation | Energy efficiency ratio ≥ 13.1
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C746-98 and provided to the Minister in respect of a large condensing unit:
(a)its classification as set out in Column II of Table 1 of CSA C746-98;
(b)its cooling capacity, expressed in kilowatts (British thermal units per hour); and
(c)its energy efficiency ratio.
CSA C743-02 means the CSA standard CAN/CSA-C743-02 entitled Performance Standard for Rating Packaged Water Chillers. (CSA C743-02)
CSA C743-09 means the CSA standard CAN/CSA-C743-09 entitled Performance Standard for Rating Packaged Water Chillers. (CSA C743-09)
(1)A chiller is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 142, a chiller is not considered to be an energy-using product unless it has an integral refrigerant condenser and is manufactured on or after October 28, 2004.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to chillers that are manufactured during the periods set out in column 3.
(2)A chiller complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a chiller as defined in section 140. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C743-02 | CSA C743-02, Tables 9 to 15 | On or after October 28, 2004 and before January 1, 20172 | CSA C743-09 | Product’s coefficient of performance and integrated part-load value must meet those applicable to the product in CSA C743-09, Path A or Path B, Table 10 | On or after January 1, 2017 and before December 31, 20193 | ASHRAE 90.1-16, table 6.8.1-3, column 6 | Product’s coefficient of performance and integrated part-load value must meet those applicable to the product in ASHRAE 90.1-16, Path A or Path B, Table 6.8.1-3 | On or after December 31, 2019
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a chiller described in column 1.Item | Column 1 | Column 2 | Column 3Energy-using Product | Testing Standard | Information1 | Chillers manufactured on or after October 28, 2004 and before January 1, 2017 | CSA C743-02 | (a)type;(b)net cooling/heating capacity in kW (tons);(c)coefficient of performance; and(d)integrated part-load value or non-standard part-load value and a list of non-standard conditions.2 | Chillers manufactured on or after January 1, 2017 and before December 31, 2019 | CSA C743-09 | (a)type;(b)net cooling/heating capacity, in kW (tons);(c)coefficient of performance;(d)compliance path for the energy-efficiency standard, namely, Path A or Path B of Table 10 to CSA C743-09; and(e)integrated part-load value or non-standard part-load value and a list of non-standard conditions.3 | Chillers manufactured on or after December 31, 2019 | ASHRAE 90.1-16, Table 6.8.1-3, column 6 | (a)type;(b)net cooling/heating capacity in kW (tons);(c)coefficient of performance;(d)compliance path for the energy-efficiency standard, namely, Path A or Path B of Table 6.8.1-3 of ASHRAE 90.1-16;(e)integrated part-load value; and(f)list of non-standard conditions for centrifugal chillers designed for non-standard operation.note
(2)However, for the purposes of sections 4, 5 and 189, a ground-source heat pump is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to ground-source heat pumps that are manufactured during the periods set out in column 3.
(2)A ground source heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a ground source heat pump as defined in section 187. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C446-94 | CSA C446-94, Table 2 | On or after February 3, 1995 and before June 1, 20062 | CSA C13256-1 | CSA C13256-1, Table 10A, first row, for the open-loop systemCSA C13256-1, Table 10A, second row, for the closed-loop system | On or after June 1, 2006
(b)its cooling capacity, expressed in kilowatts (British thermal units per hour);
(c)its cooling coefficient of performance;
(d)its heating capacity, expressed in kilowatts (British thermal units per hour);
(e)its heating coefficient of performance; and
(f)the ground-source system for which the product is intended, namely, open-loop, closed-loop or both open-loop and closed-loop.
(2)The information must be collected in accordance with
(a)CSA C446-94, if the product was manufactured on or after February 3, 1995 and before June 1, 2006; or
(b)CSA C13256-1, if the product is manufactured on or after June 1, 2006.
1 | Internal water loop heat pumps that have a cooling capacity of < 5 kW | Cooling coefficient of performance ≥ 3.28 with 30°C inlet waterHeating coefficient of performance ≥ 4.2 with 20°C inlet water
2 | Internal water loop heat pumps that have a cooling capacity of ≥ 5 kW but ≤ 40 kW | Cooling coefficient of performance ≥ 3.52 with 30°C inlet waterHeating coefficient of performance ≥ 4.2 with 20°C inlet water
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C13256-1 and provided to the Minister in respect of an internal water loop heat pump:
CSA C746-98 means the CSA standard CAN/CSA-C746-98 entitled Performance Standard for Rating Large Air Conditioners and Heat Pumps. (CSA C746-98)
IEER means the integrated energy efficiency ratio, expressed in British thermal units per watt hour, that constitutes a single number cooling part-load efficiency metric of a large heat pump. (IEER)
large heat pump means a commercial or industrial unitary heat pump that is intended for air-conditioning and space-heating applications and that has a cooling capacity of at least 19 kW (65,000 Btu/h) but less than 223 kW (760,000 Btu/h). It does not include a single package vertical heat pump. (thermopompe de grande puissance)
10 C.F.R. Appendix A means Appendix A to Subpart F, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Air-Cooled Small (≥65,000 Btu/h), Large, and Very Large Commercial Package Air Conditioning and Heating Equipment, as amended from time to time. (appendice A 10 C.F.R.)
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to large heat pumps described in column 1 that are manufactured during the periods set out in column 4 and that have no heating section or have an electric heating section.
(2)The energy efficiency standards set out in column 3 of Table 2 to this section apply to large heat pumps described in column 1 that are manufactured during the periods set out in column 4 and that have a heating section other than an electric heating section.
(3)A large heat pump complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a large heat pump as defined in section 195. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-98 | Energy efficiency ratio ≥ 10.1Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.2 with –8.3°C inlet air | On or after December 31, 1998 and before January 1, 20102 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 11.2 | On or after January 1, 2010 and before January 1, 20183 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-17 | Energy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 12.2 | On or after January 1, 2018 and before January 1, 20264 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.4 with 8.3°C inlet air and ≥ 2.25 with −8.3°C inlet airIEER ≥ 14.1 | On or after January 1, 20265 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-98 | Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.1 with 8.3°C inlet air and ≥ 2.0 with −8.3°C inlet air | On or after December 31, 1998 and before January 1, 20106 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.6Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.7 | On or after January 1, 2010 and before January 1, 20187 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-17 | Energy efficiency ratio ≥ 10.6Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 11.6 | On or after January 1, 2018 and before January 1, 20268 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.6Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 13.5 | On or after January 1, 20269 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 9.5Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 9.6 | On or after January 1, 2010 and before January 1, 201810 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-17 | Energy efficiency ratio ≥ 9.5Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.6 | On or after January 1, 2018 and before January 1, 202611 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 9.5Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 12.5 | On or after January 1, 2026 | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-98 | Energy efficiency ratio ≥ 9.9Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.2 with –8.3°C inlet air | On or after December 31, 1998 and before January 1, 20102 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 11.0 | On or after January 1, 2010 and before January 1, 20183 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-17 | Energy efficiency ratio ≥ 10.8Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 12.0 | On or after January 1, 2018 and before January 1, 20264 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.8Heating coefficient of performance ≥ 3.4 with 8.3°C inlet air and ≥ 2.25 with −8.3°C inlet airIEER ≥ 13.9 | On or after January 1, 20265 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-98 | Energy efficiency ratio ≥ 9.1Heating coefficient of performance ≥ 3.1 with 8.3°C inlet air and ≥ 2.0 with −8.3°C inlet air | On or after December 31, 1998 and before January 1, 20106 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.4Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.5 | On or after January 1, 2010 and before January 1, 20187 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-17 | Energy efficiency ratio ≥ 10.4Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 11.4 | On or after January 1, 2018 and before January 1, 20268 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.4Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 13.3 | On or after January 1, 20269 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 9.4 | On or after January 1, 2010 and before January 1, 201810 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-17 | Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.4 | On or after January 1, 2018 and before January 1, 202611 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 12.3 | On or after January 1, 2026
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a large heat pump described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Large heat pumps manufactured on or after December 31, 1998 and before January 1, 2010 | CSA C746-98 | (a)product classification set out in columns II and III of Table 2 of CSA C746-98;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)heating capacity, in kW (Btu/h);(e)heating coefficient of performance at 8.3°C;(f)heating coefficient of performance at –8.3°C; and(g)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric.2 | Large heat pumps manufactured on or after January 1, 2010 and before January 1, 2018 | CSA C746-06AHRI 340/360 for IEER | (a)product classification set out in columns II and III of Table 2 of CSA C746-06;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)heating capacity, in kW (Btu/h);(e)heating coefficient of performance at 8.3°C;(f)heating coefficient of performance at –8.3°C;(g)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric; and(h)IEER.3 | Large heat pumps manufactured on or after January 1, 2018 and before January 1, 2026 | CSA C746-17 | (a)product classification set out in columns II and III of Table 2 of CSA C746-17;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)heating capacity, in kW (Btu/h);(e)heating coefficient of performance at 8.3°C;(f)heating coefficient of performance at –8.3°C;(g)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric; and(h)IEER.4 | Large heat pumps manufactured on or after January 1, 2026 | CSA C746-17 or 10 C.F.R. Appendix A | (a)product classification set out in columns II and III of Table 2 of CSA C746-17;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)heating capacity, in kW (Btu/h);(e)heating coefficient of performance at 8.3°C;(f)heating coefficient of performance at −8.3°C;(g)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric; and(h)IEER.note
packaged terminal heat pump means a factory-built packaged heat pump that consists of a separate unencased refrigeration system and uses reverse cycle refrigeration as its primary heat source. (thermopompe terminale autonome)
(2)However, for the purposes of sections 4, 5 and 201, a packaged terminal heat pump is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to packaged terminal heat pumps that are manufactured during the periods set out in column 3.
(2)A packaged terminal heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a packaged terminal heat pump as defined in section 199. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C744-04 | CSA C744-04, Table 2 | On or after December 31, 1998 and before September 30, 20122 | CSA C744-17 | CSA C744-17, Table 2 | On or after September 30, 2012
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a packaged terminal heat pump:
(a)its cooling capacity, expressed in kilowatts (British thermal units per hour);
(b)its energy efficiency ratio;
(c)its heating capacity, expressed in kilowatts (British thermal units per hour);
(d)its heating coefficient of performance; and
(e)if applicable, identification of the product as a replacement unit.
(2)The information must be collected in accordance with
(a)CSA C744-04, if the product was manufactured on or after December 31, 1998 and before September 30, 2012; or
(b)CSA C744-17, if the product is manufactured on or after September 30, 2012.
note
[Repealed, SOR/2022-265, s. 15]
through-the-wall means, in respect of a single package central heat pump, one that has a cooling capacity less than or equal to 8.79 kW (30,000 Btu/h), that is designed to be installed through an exterior wall and that is manufactured prior to January 1, 2023. (murale)
(2)However, for the purposes of sections 4, 5 and 205, a single package central heat pump is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C746-17 and provided to the Minister in respect of a single package vertical heat pump:
(a)its classification set out in columns II and III of Table 2 to CSA C746-17;
(b)its cooling capacity, expressed in kilowatts (British thermal units per hour);
(c)its energy efficiency ratio;
(d)its heating capacity, expressed in kilowatts (British thermal units per hour); and
(e)its heating coefficient of performance.
note
note
2.1 | Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and do not have an integrated cooling component | CSA P.2, for annual fuel utilization efficiency10 C.F.R. Appendix AA, for FER | Annual fuel utilization efficiency ≥ 95%FER ≤ FER for product class “Non-Weatherized, Condensing Gas Furnace Fan (NWG-C)”, set out in 10 C.F.R. §430.32(y) | On or after July 3, 2019
3 | Gas furnaces that are outdoor furnaces, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling component | CSA P.2 | Annual fuel utilization efficiency ≥ 78% | On or after December 31, 2009 and before July 3, 2019
3.1 | Gas furnaces that are outdoor furnaces, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling component | CSA P.2, for annual fuel utilization efficiency10 C.F.R. Appendix AA, for FER | Annual fuel utilization efficiency ≥ 78%FER ≤ FER for product class “Weatherized Non-Condensing Gas Furnace Fan (WG-NC)”, set out in 10 C.F.R. §430.32(y) | On or after July 3, 2019
4 | Gas furnaces that are through-the-wall, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling component | CSA P.2 | Annual fuel utilization efficiency ≥ 78% | On or after December 31, 2009 and before December 31, 2012
5 | Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that are through-the-wall, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling component | CSA P.2 | Annual fuel utilization efficiency ≥ 90% | On or after December 31, 2012 and before January 1, 2024
5.1 | Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that are space-constrained, have an input rate of ≤ 65.92 kW (225,000 Btu/h) and have an integrated cooling component | CSA P.2 | Annual fuel utilization efficiency ≥ 90% | On or after January 1, 2024
6 | Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and use three-phase electric current | CSA 2.3 | Annual fuel utilization efficiency ≥ 78%orThermal efficiency ≥ 80% | On or after February 3, 1995
7 | Gas furnaces that have an input rate of > 65.92 kW (225,000 Btu/h) but ≤ 117.23 kW (400,000 Btu/h) | CSA 2.3 | Thermal efficiency ≥ 80% | On or after February 3, 1995
8 | Gas furnaces for relocatable buildings | CSA P.2 for annual fuel utilization efficiency10 C.F.R. Appendix AA, for fan energy rating | Annual fuel utilization efficiency ≥ 80%FER ≤ FER for product class “Mobile Home Non-Weatherized, Non-Condensing Gas Furnace Fan (MH-NWG-NC)”, set out in 10 C.F.R. §430.32(y) | On or after July 3, 2019
9 | Replacement non-condensing gas furnaces | CSA P.2 for annual fuel utilization efficiency10 C.F.R. Appendix AA, for fan energy rating | Annual fuel utilization efficiency ≥ 80%FER ≤ FER for product class “Mobile Home Non-Weatherized, Non-Condensing Gas Furnace Fan (MH-NWG-NC)”, set out in 10 C.F.R. §430.32(y) | On or after July 3, 2019
2.1 | Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured on or after July 3, 2019 | CSA P.2, for information set out in paragraphs (a) to (e)10 C.F.R. Appendix AA, for information set out in paragraphs (f) and (g) | (a)maximum heat input and output nominal capacities, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)information that indicates whether product has an integrated cooling component;(d)if product has an integrated cooling component, information that indicates whether the product is outdoor or through-the-wall;(e)type of fuel used;(f)FER, expressed in W/472 L/s (W/1,000 ft³/min);(g)product’s maximum airflow (Qmax), expressed in L/s (ft³/min); and(h)if applicable, information that indicates whether product is gas furnace for relocatable buildings or is replacement non-condensing gas furnace.
2.2 | Gas furnaces that are through-the-wall, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current, that have an integrated cooling component and that are manufactured on or after December 31, 2009 and before January 1, 2024 | CSA P.2 for information set out in paragraphs (a) to (c) | (a)maximum heat input and output nominal capacities, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)type of fuel used; and(d)if applicable, information that indicates whether product is gas furnace for relocatable buildings or is replacement non-condensing gas furnace.
2.3 | Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that are space-constrained, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that have an integrated cooling component and that are manufactured on or after January 1, 2024 | CSA P.2 for information set out in paragraphs (a) to (c) | (a)maximum heat input and output nominal capacities, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)type of fuel used; and(d)type of blower fan motor, namely brushless permanent magnet, permanent split-capacitor or other.
3 | Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and that use three-phase electric current | CSA 2.3 | (a)heating capacity, in kW (Btu/h); and(b)annual fuel utilization efficiency or thermal efficiency.
4 | Gas furnaces that have an input rate of > 65.92 kW (225,000 Btu/h) but ≤ 117.23 kW (400,000 Btu/h) | CSA 2.3 | (a)heating capacity, in kW (Btu/h); and(b)thermal efficiency.
5 | Gas furnaces for relocatable buildings manufactured on or after January 1, 2024 | CSA P.2 for information set out in paragraphs (a) to (c)10 C.F.R. Appendix AA for information set out in paragraphs (d) and (e) | (a)maximum heat input and output nominal capacities, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)type of fuel used;(d)FER, expressed in W/472 L/s (W/1,000 ft3/min); and(e)product’s maximum airflow (Qmax), expressed in L/s (ft3/min).
6 | Replacement non-condensing gas furnaces manufactured on or after January 1, 2024 | CSA P.2 for information set out in paragraphs (a) to (c)10 C.F.R. Appendix AA for information set out in paragraphs (d) and (e) | (a)maximum heat input and output nominal capacities, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)type of fuel used;(d)FER, expressed in W/472 L/s (W/1,000 ft3/min); and(e)product’s maximum airflow (Qmax), expressed in L/s (ft3/min).note
(b)capable of being fired, at the choice of the user, by either oil or another fuel. (générateur d’air chaud à mazout)
(2)However, for the purposes of sections 4, 5 and 263, an oil-fired furnace is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.
)
decorative gas fireplace means a vented fireplace that is fuelled by natural gas or propane, is marked for decorative use only and is not equipped with a thermostat or intended for use as a heater. (foyer à gaz décoratif)
(h)if the product is a decorative gas fireplace that is manufactured on or after January 1, 2020, information that indicates whether it is intended for use as a replacement unit.
(2)The information must be collected in accordance with
(a)CSA P.4.1, if the product was manufactured on or after June 1, 2003 and before January 1, 2017; or
(b)CSA P.4.1-15, if the product is manufactured on or after January 1, 2017.
(2)However, for the purposes of sections 4, 5 and 270, a gas-fired unit-heater is not considered to be an energy-using product unless it is manufactured on or after August 8, 2008.
(a)its thermal efficiency must be at least 80% at the maximum heat input nominal capacity; and
(b)it must be equipped with an intermittent ignition device and
(i)a power-vented system,
(ii)an automatic vent damper, or
(iii)an automatic flue damper.
(2)A gas-fired unit heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA P.11 that are applicable to a gas-fired unit heater as defined in section 268.
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA P.11 and provided to the Minister in respect of a gas-fired unit heater:
(a)the type of fuel it uses;
(b)the type of ignition system it has;
(c)the venting configuration it has, namely, a power-vented system, an automatic vent damper or an automatic flue damper;
(d)its maximum heat input and output nominal capacities, expressed in kilowatts;
(e)its thermal efficiency when at the maximum heat input nominal capacity;
(f)its electricity consumption, expressed in kilowatt hours, when at the maximum nominal heat input capacity; and
(i)its reduced heat input and output nominal capacities, expressed in kilowatts, and
(ii)its electricity consumption, expressed in kilowatt hours, when at reduced heat input nominal capacity.
means a boiler that uses exclusively propane or natural gas, is intended for application in a low pressure steam, or hot water, central heating system and has an input rate of not more than 2 930.71 kW (10,000,000 Btu/h). (
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas boiler described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Household gas boilers manufactured on or after December 31, 1998 and before September 1, 2010 | CGA P.2 | (a)type of fuel used;(b)type of central heating system for which product is intended;(c)input rate, in kW (Btu/h); and(d)annual fuel utilization efficiency.2 | Household gas boilers manufactured on or after September 1, 2010 and before January 15, 2021 and intended for low pressure steam systems | CSA P.2 | (a)type of fuel used;(b)maximum heat input and output nominal capacities, in kW (Btu/h); and(c)annual fuel utilization efficiency.3 | Household gas boilers manufactured on or after January 15, 2021 and intended for low pressure steam systems | CSA P.2 | (a)type of fuel used;(b)maximum heat input and output nominal capacities, in kW (Btu/h);(c)annual fuel utilization efficiency;(d)standby power, in W; and(e)off-mode power, in W.4 | Household gas boilers, other than those intended for low pressure steam systems, manufactured on or after September 1, 2010 and before July 1, 2023 | CSA P.2 for information set out in paragraphs (a) to (c) | (a)type of fuel used;(b)maximum heat input and output nominal capacities, in kW (Btu/h);(c)annual fuel utilization efficiency; and(d)if product is manufactured on or after September 1, 2012 and before July 1, 2023,(i)information that indicates whether product has tankless domestic water heating coils, and(ii)type of automatic water temperature adjustment device it has, if any.5 | Household gas boilers, other than those intended for low pressure steam systems, manufactured on or after July 1, 2023 | CSA P.2 for information set out in paragraphs (a) to (e) | (a)type of fuel used;(b)maximum heat input and output nominal capacities, in kW (Btu/h);(c)annual fuel utilization efficiency;(d)standby power, in W;(e)off-mode power, in W;(f)information that indicates whether product has tankless domestic water heating coils; and(g)type of automatic water temperature adjustment device it has, if any.6 | Commercial gas boilers manufactured on or after January 1, 2025 | 10 C.F.R. Appendix A | (a)type of central heating system for which product is intended;(b)maximum heat input nominal capacity, in kW (Btu/h); and(c)thermal efficiency or, if product has an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and is intended for hot water systems, combustion efficiency.note
(b)capable of being fired, at the choice of the user, by either oil or another fuel. (chaudière à mazout)
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an oil-fired boiler described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Household oil-fired boilers manufactured on or after December 31, 1998 and before September 1, 2010 | CSA B212 | (a)input rate, in kW (Btu/h); and(b)seasonal energy utilization efficiency.2 | Household oil-fired boilers manufactured on or after September 1, 2010 and before January 15, 2021 | ASHRAE 103 for information set out in paragraphs (a) to (f) | (a)type of central heating system for which product is intended;(b)maximum heat input and output nominal capacities, in kW (Btu/h);(c)power burner’s PE;(d)water pump’s BE;(e)average annual electrical energy consumption (EAE), in kWh;(f)annual fuel utilization efficiency; and(g)if product is manufactured on or after September 1, 2012,(i)information that indicates whether product has tankless domestic water heating coils, and(ii)type of automatic water temperature adjustment device product has, if any.3 | Household oil-fired boilers manufactured on or after January 15, 2021 | CSA P.2 for information set out in paragraphs (a) to (e) | (a)type of central heating system for which product is intended;(b)maximum heat input and output nominal capacities, in kW (Btu/h);(c)annual fuel utilization efficiency;(d)standby power, in W;(e)off-mode power, in W;(f)information that indicates whether product has tankless domestic water heating coils; and(g)type of automatic water temperature adjustment device product has, if any.4 | Commercial oil-fired boilers manufactured on or after January 1, 2025 | 10 C.F.R. Appendix A | (a)type of central heating system for which product is intended;(b)maximum heat input nominal capacity, in kW (Btu/h); and(c)thermal efficiency or, if product has an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and is intended for hot water systems, combustion efficiency.note
(b)it is a commercial oil-fired water heater that is manufactured on or after January 1, 2020.
note
(3)The words “lumens”, “lumens/watt”, “watts”, “hours”, “heures” and “Kelvin” and the upper case letter “K” must be in the same font and be equal in size, but they must not be more than 50% of the size of the words referred to in subsection (2).
(4)The numerical values indicating the product’s luminous flux, efficacy, nominal power, life and correlated colour temperature must be in the same font and be equal in size.
(5)If the product is a three-way lamp, the information required by paragraphs (1)(a) to (c) must be displayed for each level of the lamp’s operation.
(6)If the product has a variable correlated colour temperature, the information required by paragraph (1)(e) must be displayed for the lamp’s range of operation or for each level of its operation.
(1)If the design voltage of the product is other than 120 V, the information required by section 426 may correspond to
(a)a voltage of 120 V, followed by the words “at 120 volts” and “à 120 volts”; or
(b)the design voltage, followed by the words, “at [design voltage] volts” and “à [tension spécifique]”.
(2)If the information corresponds to the design voltage,
(a)the following statements must be displayed on the principal display panel:“This product is designed for [design voltage] volts. When used on the normal line voltage of 120 volts, the light output and energy efficiency are noticeably reduced. See [appropriate panel] panel for 120-volt rating.”« Ce produit a été conçu en fonction d’une tension de [tension spécifique] volts. S’il est employé à la tension normale de 120 volts, son flux lumineux et son efficacité énergétique s’en trouveront considérablement réduits. Voir le panneau [panneau en cause] pour les renseignements correspondant à une tension de 120 volts. »;
(b)the information required by section 426 for the product corresponding to a voltage of 120 V, followed by the words “at 120 volts” and “à 120 volts”, must be displayed on a panel of the product’s package other than the principal display panel; and
(c)the design voltage must be displayed on every panel that displays the information required by section 426, other than the panel on which the information required by paragraph (b) is displayed.
If more than one type of lamp is included in a common package and their characteristics are not uniform, the principal display panel of the common package must display the following information for each type of lamp:
(a)its design voltage; and
(b)the information required by section 426, which must be in the size and font specified in that section.
)
ANSI C78.81 means the ANSI standard ANSI C78.81-2010 entitled American National Standard for Electric Lamps Double-Capped Fluorescent Lamps — Dimensional and Electrical Characteristics. (ANSI C78.81)
ANSI C78.901 means the ANSI standard ANSI C78.901-2005 entitled American National Standard for Electric Lamps Single — Based Fluorescent Lamps — Dimensional and Electrical Characteristics. (ANSI C78.901)
CSA C819-11 means the CSA standard CAN/CSA-C819-11 entitled Performance of general service fluorescent lamps. (CSA C819-11)
CSA C819-16 means the CSA standard CAN/CSA-C819-16 entitled Performance of General Service Fluorescent Lamps. (CSA C819-16)
cold temperature fluorescent lamp means a fluorescent lamp that is marketed for outdoor or cold temperature use and that is designed to start at temperatures as low as –29°C (–20°F) when used with a ballast that conforms to the requirements of ANSI C78.81 and ANSI C78.901. (lampe fluorescente pour basses températures)
(b)a correlated colour temperature of less than 2 500 K or more than 7 000 K, as determined in accordance with the IES standard IES LM-9-09 entitled IES Approved Method for the Electrical and Photometric Measurement of Fluorescent Lamps. (lampe fluorescente colorée)
(a)is straight-shaped and has a nominal overall length of 1 200 mm (48 inches), a medium bi-pin base and a nominal power of at least 25 W;
(b)is U-shaped and has a nominal overall length of at least 560 mm (22 inches) but not more than 635 mm (25 inches), a medium bi-pin base and a nominal power of at least 25 W;
(c)is rapid-start and straight-shaped and has a nominal overall length of 2 400 mm (96 inches) and a recessed double-contact base;
(d)is instant-start and straight-shaped and has a nominal overall length of 2 400 mm (96 inches), a single-pin base and a nominal power of at least 49 W;
(e)is straight-shaped and standard output and has a nominal overall length of at least 1 125 mm (45 inches) but not more than 1 200 mm (48 inches), a miniature bi-pin base and a nominal power of at least 25 W;
(f)is straight-shaped and high output with a nominal overall length of at least 1 125 mm (45 inches) but not more than 1 200 mm (48 inches), a miniature bi-pin base and a nominal power of at least 44 W; or
(g)is a physical and electrical equivalent of a lamp described in any of paragraphs (a) to (f).
(h)a fluorescent lamp that is marketed as a plant lamp;
(2)However, for the purpose of section 4, a general service fluorescent lamp is not considered to be an energy-using product unless it is manufactured on or after December 31, 1996.
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a general service fluorescent lamp:
(a)its nominal power, expressed in watts;
(b)its shape;
(c)its nominal overall length;
(d)its diameter;
(e)its base type;
(f)its abbreviation under the designation system in ANSI C78.81, Annex A, and ANSI C78.901, Annex B;
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a fluorescent lamp ballast described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Fluorescent lamp ballasts manufactured on or after February 3, 1995 and before November 14, 2014 | CSA C654-10 | (a)ballast efficacy factor;(b)type and number of fluorescent lamps it is designed to operate; and(c)nominal voltage.2 | Fluorescent lamp ballasts manufactured on or after November 14, 2014, other than T12 dimming ballasts | CSA C654-14 | (a)class number set out in Table 1A of CSA C654-14;(b)ballast luminous efficiency;(c)nominal voltage;(d)ballast input power, in watts;(e)total lamp arc power, in watts; and(f)power factor.3 | T12 dimming ballasts manufactured on or after November 14, 2014 | CSA C654-14 | (a)the type and number of fluorescent lamps it is designed to operate;(b)ballast luminous efficiency;(c)nominal voltage;(d)ballast input power, in watts;(e)total lamp arc power, in watts;(f)power factor; and(g)whether it is high-frequency or low-frequency.note
(1)A torchiere is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 509, a torchiere is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to torchieres described in column 1 that are manufactured during the periods set out in column 3.
(2)A torchiere complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C22.2 No. 250.4 that are applicable to a torchiere as defined in section 507. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Energy Efficiency Standard | Period of Manufacture1 | Torchieres that have no additional sockets | Total power ≤ 190 W | On or after January 1, 2007 and before January 1, 20102 | Torchieres that have no additional sockets | Total power ≤ 75 W | On or after January 1, 20103 | Torchieres that have one or more additional sockets | Total power ≤ 230 W | On or after January 1, 2007 and before January 1, 20104 | Torchieres that have one or more additional sockets | Total power ≤ 100 W | On or after January 1, 2010
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C22.2 No. 250.4 and provided to the Minister in respect of a torchiere:
(a)information that indicates whether the product has lighting functions additional to those of the bowl; and
(b)the total power, expressed in watts, for all lighting functions.
if it is manufactured on or after January 7, 2019, it has at least one socket, has maximum wattage markings on each socket that together indicate that the combined total power for the lighting is less than or equal to 70 W and does not have non-consumer-replaceable solid-state lighting.
note
legend means any of the following that is displayed on an exit sign:
(a)a representation of a running person, as described in Annex B.1 of the CSA standard CSA C22.2 No. 141 entitled Emergency lighting equipment; and
(1)An exit sign is prescribed as an energy-using product.
(2)However, for the purpose of section 4, an exit sign is not considered to be an energy-using product unless it is manufactured on or after November 1, 2004.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to exit signs described in column 1.
(2)An exit sign complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C860 that are applicable to an exit sign as defined in section 519. | Column 1 | Column 2Item | Energy-using Product | Energy Efficiency Standard1 | Type 1 and Type 2 exit signs | Wattage ≤ 5 W × (number of legends)2 | Type 3 exit signs | Wattage ≤ 5 W × (number of legends) + 5 W
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C860 and provided to the Minister in respect of an exit sign:
(2)However, for the purposes of sections 4, 5 and 525, a traffic signal module is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007.
(1)The energy efficiency standards set out in column 3 of the table to this section apply to traffic signal modules described in column 1.
(2)For the purpose of subsection (1), the maximum power and nominal power of a traffic signal module must be determined in accordance with the following procedures:
(a)the luminous intensity of the product must be determined in accordance with the procedures established by the standard set out in column 2 that are applicable to a traffic signal module as defined in section 523;
(b)the product’s power must be measured using a watt meter that has an accuracy of ± 1%;
(c)when determining the product’s maximum power, the product must be
(i)mounted in a temperature testing chamber with the lens portion of the product outside the chamber, and
(ii)operated for a minimum of 60 minutes at a temperature of 74°C and with the temperature in front of the lens maintained at a minimum of 49°C; and
(d)when determining the product’s nominal power, the product must be operated for a minimum of 60 minutes at an ambient temperature of 25°C.
| Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Energy Efficiency Standard1 | Traffic signal modules that have a red traffic signal indicator that has a nominal diameter of 200 mm (8 inches) | VTCSH Circular | Maximum power ≤ 13 WNominal power ≤ 8 W2 | Traffic signal modules that have a red traffic signal indicator that has a nominal diameter of 300 mm (12 inches) | VTCSH Circular | Maximum power ≤ 17 WNominal power ≤ 11 W3 | Traffic signal modules that have a green traffic signal indicator that has a nominal diameter of 200 mm (8 inches) | VTCSH Circular | Maximum power ≤ 12 WNominal power ≤ 12 W4 | Traffic signal modules that have a green traffic signal indicator that has a nominal diameter of 300 mm (12 inches) | VTCSH Circular | Maximum power ≤ 15 WNominal power ≤ 15 W5 | Traffic signal modules that have a red arrow traffic signal indicator | VTCSH Arrow | Maximum power ≤ 12 WNominal power ≤ 9 W6 | Traffic signal modules that have a green arrow traffic signal indicator | VTCSH Arrow | Maximum power ≤ 11 WNominal power ≤ 11 W
(2)However, for the purposes of sections 4, 5 and 529, a pedestrian module is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to pedestrian modules described in column 1.
(2)For the purpose of subsection (1), the maximum power and nominal power of a pedestrian module must be determined in accordance with the following procedures:
(a)the luminous intensity of the product must be determined in accordance with the procedures established by PTCSI that are applicable to a pedestrian module as defined in section 527;
(b)the product’s power must be measured using a watt meter that has an accuracy of ± 1%;
(c)when determining the product’s maximum power, the product must be
(i)mounted in a temperature testing chamber with the lens portion of the product outside the chamber, and
(ii)operated for a minimum of 60 minutes at a temperature of 74°C and with the temperature in front of the lens maintained at a minimum temperature of 49°C; and
(d)when determining the product’s nominal power, the product must be operated for a minimum of 60 minutes at an ambient temperature of 25°C.
| Column 1 | Column 2Item | Energy-using Product | Energy Efficiency Standard1 | Pedestrian modules that have a walking person display and a hand display | Maximum power ≤ 16 WNominal power ≤ 13 W2 | Pedestrian modules that have a walking person display only | Maximum power ≤ 12 WNominal power ≤ 9 W3 | Pedestrian modules that have a hand display only | Maximum power ≤ 16 WNominal power ≤ 13 W
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with PTCSI and provided to the Minister in respect of a pedestrian module:
(2)However, for the purposes of sections 4, 5 and 576, a compact audio product is not considered to be an energy-using product unless it is manufactured on or after May 1, 2011.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to compact audio products described in column 1 that are manufactured during the periods set out in column 3.
(2)A compact audio product complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C62301 that are applicable to a compact audio product as defined in section 574. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Energy Efficiency Standard | Period of Manufacture1 | Compact audio products | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 3 W in standby mode; and(b)≤ 1 W in off mode. | On or after May 1, 2011 and before January 1, 20132 | Compact audio products, other than clock radios | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 1 W in standby mode with information display active;(b)≤ 0.5 W in standby mode with information display inactive;(c)≤ 0.5 W in when there is no ; and(d)≤ 0.5 W in . | On or after January 1, 20133 | Compact audio products that are clock radios | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 2 W in standby mode with information display active; and(b)≤ 1 W in off mode. | On or after January 1, 2013
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C62301 and provided to the Minister in respect of a compact audio product:
(a)its type;
(b)if it was manufactured before January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts;
(c)if it is manufactured on or after January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts, as applicable,
(d)if it has standby mode, the period, expressed in minutes, that begins when standby mode is enabled and ends when the measurement of power consumption in that mode is completed; and
(e)if it has off mode, its power consumption, expressed in watts, in off mode.
(a)is not producing video or audio output signals, providing any mechanical function or exchanging data with, or receiving it from, an external source; and
(b)can be switched into another mode with a remote control unit, an internal signal or an internal timer. (mode veille)
video product means a household electronic product that is encased in a single housing, requires a power supply device in order to operate and is designed
(1)A video product is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 580, a video product is not considered to be an energy-using product unless it is manufactured on or after May 1, 2011.
(1)The energy efficiency standards set out in column 1 of the table to this section apply to video products that are manufactured during the periods set out in column 2.
(2)A video product complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C62301 that are applicable to a video product as defined in section 578. | Column 1 | Column 2Item | Energy Efficiency Standard | Period of Manufacture1 | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 3 W in standby mode; and(b)≤ 1 W in off mode. | On or after May 1, 2011 and before January 1, 20132 | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 1 W in standby mode with information display active;(b)≤ 0.5 W in standby mode with information display inactive;(c)≤ 0.5 W in without ; and(d)≤ 0.5 W in . | On or after January 1, 2013
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C62301 and provided to the Minister in respect of a video product:
(a)if it was manufactured before January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts;
(b)if it is manufactured on or after January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts, as applicable,
(c)if it has standby mode, the period, expressed in minutes, that begins when standby mode is enabled and ends when the measurement of power consumption in that mode is completed;
(d)if it has off mode, its power consumption, expressed in watts, in off mode; and
(e)the type of playback or recording technology that it has.
(a)is not producing sound or picture, providing any mechanical function or exchanging data with, or receiving it from, an external source; and
(b)can be switched into another mode with a remote control unit, an internal signal or an internal timer. (mode veille)
television means an analog or digital product, with or without an internal tuner, that is designed primarily for the display and reception of a terrestrial, satellite, cable, Internet Protocol TV or other broadcast or recorded transmission of analog or digital video and audio signals and includes
(a)a combination television system in which a television and one or more other devices are encased as a single unit in the television casing; and
(b)a component television that has two or more separate components and that is marketed and sold as a television under one model or system designation.
(c)a television that is marketed exclusively for commercial use and is without an internal tuner; or
(d)a television that is marketed primarily for use as a computer monitor. (téléviseur)
(1)A television is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 584, a television is not considered to be an energy-using product unless it is manufactured on or after May 1, 2011.
(1)The energy efficiency standards set out in column 1 of the table to this section apply to televisions that are manufactured during the periods set out in column 2.
(2)A television complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C62301 that are applicable to a television as defined in section 582. | Column 1 | Column 2Item | Energy Efficiency Standard | Period of Manufacture1 | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 4 W in standby mode; and(b)≤ 1 W in off mode. | On or after May 1, 2011 and before January 1, 20132 | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 1 W in standby mode with information display active;(b)≤ 0.5 W in standby mode with information display inactive;(c)≤ 0.5 W in without ; and(d)≤ 0.5 W in . | On or after January 1, 2013
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C62301 and provided to the Minister in respect of a television:
(a)if it was manufactured before January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts;
(b)if it is manufactured on or after January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts, as applicable,
(c)if it has standby mode, the period, expressed in minutes, that begins when standby mode is enabled and ends when the measurement of power consumption in standby mode is completed; and
(d)if it has off mode, its power consumption, expressed in watts, in off mode.
bloc d’alimentation externe adaptatif
)
CSA C381.1 means the CSA standard CAN/CSA-C381.1-08 entitled Test method for calculating the energy efficiency of single-voltage external ac-ac and ac-ac power supplies. (CSA C381.1)
detachable battery pack means a battery that is encased in an enclosure separate from an end-use product and that is designed to be removed or disconnected from the end-use product for recharging. (bloc-batterie amovible)
direct operation external power supply means a power supply device that is capable of operating an end-use product, other than a battery charger, without the assistance of a battery. (bloc d’alimentation externe à fonctionnement direct)
(a)a direct operation external power supply that has a nominal output voltage of less than 3 V and a nominal output current of 1 000 mA or more and that charges the battery of an end-use product that is fully or primarily motor-operated;
(d)a device that is an accessory to a medical device; or
(e)a device that is solely designed to power solid-state lighting or a ceiling fan that has a direct current motor. (bloc d’alimentation externe)
indirect operation external power supply means a power supply device that can only operate an end-use product with the assistance of a battery. (bloc d’alimentation externe à fonctionnement indirect)
multiple-voltage external power supply means a device that is designed to convert line voltage AC input into more than one simultaneous lower voltage AC or DC outputs. (bloc d’alimentation externe à tensions multiples)
replacement external power supply means an external power supply that is marked as a replacement to be used with a specific end-use product that was manufactured before July 1, 2017. (bloc d’alimentation externe de remplacement)
(a)is designed to convert line voltage AC into lower voltage AC output;
(b)has a nominal output power of 20 W or more; and
(c)is designed for and marketed with equipment that operates continuously in on mode to perform any of the following principal functions:
(i)to monitor, detect, record or provide notification of any intrusion on real property or immovables, or access to real property or immovables or physical assets,
(ii)to provide notification of threats to personal safety resulting from an intrusion or access referred to in subparagraph (i),
(iii)to monitor, detect, record or provide notification of fire, gas, smoke, flooding or any other physical threats to real property or immovables, physical assets or personal safety, or
(iv)to deter or control access to real property or immovables or physical assets or prevent the unauthorized removal of physical assets.
It includes an external power supply for equipment that is designed and marketed with a built-in alarm or theft-deterrent feature and whose principal functions are those referred to in paragraph (c). (bloc d’alimentation externe de sécurité)
single-voltage external power supply means a device that is designed to convert line voltage AC input into only one lower AC or DC voltage output at a time. (bloc d’alimentation externe à simple tension)
10 C.F.R. Appendix Z means Appendix Z to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of External Power Supplies, as amended from time to time. (appendice Z 10 C.F.R.)
10 C.F.R. §430.32(w)(1)(i) means the table to paragraph 430.32(w)(1)(i) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(w)(1)(i))
verification mark has the same meaning as in section 2. (marque de vérification)
(C)it is an indirect operation external power supply that has a nominal output voltage of greater than 3 V and a nominal output current of less than 1 000 mA and that charges the battery of an end-use product that is fully or primarily motor-operated; and
(b)for the purpose of section 588 if
(i)it was manufactured before July 1, 2010,
(ii)it was manufactured on or after July 1, 2010 and before July 1, 2017 and
(C)it is an indirect operation external power supply that has a nominal output voltage of greater than 3 V and a nominal output current of less than 1 000 mA and that charges the battery of an end-use product that is fully or primarily motor-operated, or
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a commercial refrigerator:
(a)its Edaily;
(b)for each of its compartments,
(i)its equipment class designation and its TDA or V, as applicable, and
(ii)if it is tested at its lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting.
(2)The information must be collected in accordance with one of the following standards:
(a)CSA C657, Test Procedure A, if the product was manufactured before March 27, 2017; or
(b)CSA C657, Test Procedure B, if the product is manufactured on or after March 27, 2017.
note
(i)it is self-contained, is closed and is manufactured on or after April 1, 2007,
(ii)it is self-contained, is open and is manufactured on or after January 1, 2012, or
(iii)it is remote-condensing and is manufactured on or after January 1, 2012; and
(b)for the purpose of section 641, unless
(i)it is self-contained, is closed, is not transparent and is manufactured on or after April 1, 2007,
(ii)it is self-contained, is open or transparent and is manufactured on or after January 1, 2012, or
(iii)it is remote-condensing and is manufactured on or after January 1, 2012.
note
(b)for the purpose of section 644, unless
(i)it is self-contained, closed and was manufactured on or after April 1, 2007 and before January 1, 2012, or
(ii)it is manufactured on or after January 1, 2012.
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a commercial freezer:
(a)its Edaily; and
(b)for each of its compartments,
(i)its equipment class designation and its TDA or V, as applicable, and
(ii)if it is tested at its lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting.
(2)The information must be collected in accordance with one of the following standards:
(a)CSA C657, Test Procedure A, if the product was manufactured before March 27, 2017; or
(b)CSA C657, Test Procedure B, if the product is manufactured on or after March 27, 2017.
note
distributeur automatique mixte)
)
CSA C804 means the CSA standard CAN/CSA-C804:18 entitled Energy performance of refrigerated bottled or canned beverage vending machines. (CSA C804)
refrigerated beverage vending machine means a self-contained product that is designed to accept consumer payments and dispense refrigerated beverages in bottles, cans or other sealed containers. (distributeur automatique de boissons réfrigérées)
(a)is designed to accept consumer payments and dispense packages of solid non-refrigerated food and bottled, canned or other sealed refrigerated beverages; and
(b)has a vendible capacity of not more than 100 of those beverages. (distributeur automatique de boissons réfrigérées et de collations)
standby mode means a mode into which the product automatically enters during a period of extended inactivity that is capable of reducing its energy consumption by means of the following power states:
(a)a refrigeration power state in which the average temperature of the refrigerated beverages is allowed to rise to 4.4°C; and
(b)if the product is equipped with lights,
(i)a lighting power state in which the lights are turned off, and
(ii)a machine power state in which the power states referred in paragraph (a) and subparagraph (i) are in operation at the same time. (mode veille)
(2)However, for the purposes of sections 4, 5 and 648, a refrigerated beverage vending machine is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007.
(1)The energy efficiency standards set out in column 2 of the table to this section apply to refrigerated beverage vending machines described in column 1 that are manufactured during the periods set out in column 3.
(a)subject to paragraph (b), it is manufactured before January 8, 2019 and tested in accordance with testing procedures established by sections 1 to 7.2 of ASHRAE 32.1 that are applicable to a refrigerated beverage vending machine as defined in section 646, except that the ambient temperature during the testing to determine Edaily must be 23.9°C ± 1°C;
(b)it is manufactured before August 31, 2012, is designed to display and dispense less than 20 discrete types of beverages and is tested in accordance with testing procedures established by sections 1 to 7.2 of ASHRAE 32.1 that are applicable to a refrigerated beverage vending machine as defined in section 646, except that the ambient temperature during the testing to determine the Edaily must be 32.2°C ± 1°C; or
(c)it is manufactured on or after January 8, 2019 and tested in accordance with testing procedures established by CSA C804.
| Column 1 | Column 2 | Column 3Item | Energy-using Product | Energy Efficiency Standard | Period of Manufacture1 | Refrigerated beverage vending machines, other than those that display and dispense 20 or more discrete types of beverages | Edaily ≤ 55% (8.66 + 0.009 × vendible capacity)Must be capable of operating in standby mode | On or after January 1, 2007 and before January 1, 20082 | Refrigerated beverage vending machines, other than those that display and dispense 20 or more discrete types of beverages | Edaily ≤ 45% (8.66 + 0.009 × vendible capacity)Must be capable of operating in standby mode | On or after January 1, 2008 and before August 31, 20123 | Refrigerated beverage vending machines that display and dispense 20 or more discrete types of beverages | Edaily ≤ 55% (8.66 + 0.009 × vendible capacity)Must be capable of operating in standby mode | On or after January 1, 2007 and before August 31, 2012
(2)However, for the purposes of sections 4, 5 and 651, a snack and refrigerated beverage vending machine is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007 and before January 8, 2019.
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with ASHRAE 32.1, with the testing procedures adjusted in accordance with subsection 651(2), and be provided to the Minister in respect of a snack and refrigerated beverage vending machine:
(a)its Edaily; and
(b)its vendible capacity.
CSA C742-98 means the CSA standard CAN/CSA-C742-98 entitled Performance of Automatic Ice-Makers and Ice Storage Bins. (CSA C742-98)
ice-maker means a factory-assembled automatic ice-maker that has a capacity of at least 23 kg/day (51 pounds per day) but not more than 1 814 kg/day (4,000 pounds per day) and that produces cubed, flaked, crushed or fragmented ice in either a batch or a continuous process. (machine à glaçons)
10 C.F.R. §431.134 means section 431.134 of Subpart H, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.134)
(1)An ice-maker is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 655, an ice-maker is not considered to be an energy-using product unless
(a)it is manufactured on or after December 31, 1998 and before January 28, 2018 and has a capacity of not more than 1 000 kg/day (2,200 pounds per day); or
(b)it is manufactured on or after January 28, 2018 and has a capacity of not more than 1 814 kg/day (4,000 pounds per day).
(1)The energy efficiency standards set out in column 3 of the table to this section apply to ice-makers described in column 1 that are manufactured during the periods set out in column 4.
(2)An ice-maker complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to an ice-maker as defined in section 653. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Ice-makers that have a capacity of ≥ 23 kg/day (51 lbs/day) but ≤ 1 000 kg/day (2,200 lbs/day) | CSA C742-98 | CSA C742-98, Table 2 | On or after December 31, 1998 and before January 1, 20082 | Ice-makers that have a capacity of ≥ 23 kg/day (51 lbs/day) but ≤ 1 000 kg/day (2,200 lbs/day) and that produce ice in a continuous process | CSA C742-98 | CSA C742-98, Table 2, categories “Continuous automatic ice-makers” and “Ice storage bins” | On or after January 1, 2008 and before January 28, 20183 | Ice-makers that have a capacity of ≥ 23 kg/day (51 lbs/day) but ≤ 1 000 kg/day (2,200 lbs/day) and that produce ice in a batch process | CSA C742-08 | CSA C742-08, Tables 2 and 3 | On or after January 1, 2008 and before January 28, 20184 | Ice-makers | CSA C742-15 or 10 C.F.R. §431.134 | CSA C742-15, Tables 3 to 5 | On or after January 28, 2018
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an ice-maker described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Ice-makers manufactured on or after December 31, 1998 and before January 1, 2008 | CSA C742-98 | (a)ice-making capacity, in kg/day;(b)configuration of product, namely, one cabinet or split system;(c)ice-making process, namely batch process or continuous process;(d)condensing unit type, namely, air-cooled or water-cooled; and(e)input energy rating, in kJ/kg (kWh/100 lbs) of ice.2 | Ice-makers manufactured on or after January 1, 2008 and before January 28, 2018 | CSA C742-98 for ice-makers that produce ice in a continuous processCSA C742-08 for ice-makers that produce ice in a batch process | (a)ice-making capacity, in kg/day;(b)configuration of product, namely,(i)ice-making mechanism and condenser are combined in single package,(ii)self-contained,(iii)remote condenser but no remote compressor, or(iv)remote condenser and remote compressor;(c)ice-making process, namely, batch process or continuous process;(d)condensing unit type, namely, air-cooled or water-cooled;(e)the input energy rating, in kJ/kg (kWh/100 lbs) of ice; and(f)if product has an ice storage bin, the bin capacity, in kg, and its storage effectiveness, as a percentage.3 | Ice-makers manufactured on or after January 28, 2018 | CSA C742-15 | (a)ice-making capacity, in kg/day;(b)configuration of product, namely,(i)ice-making mechanism and condenser are combined in single package,(ii)self-contained,(iii)remote condenser but no remote compressor, or(iv)remote condenser and remote compressor;(c)ice-making process, namely, batch process or continuous process;(d)condensing unit type, namely, air-cooled or water-cooled;(e)the input energy rating, in kJ/kg (kWh/100 lbs) of ice; and(f)if product has an ice storage bin, the bin capacity, in kg, and its storage effectiveness, as a percentage.note
(a)for the purposes of sections 4 and 5, if it was manufactured before January 1, 2005; and
(b)for the purpose of section 705, if it has a BIL of more than 150 kV and was manufactured before January 1, 2010.
| Column 1 | Column 2 | Column 3
Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture
1 | CSA C802.2 | CSA C802.2, Table 1 | On or after January 1, 2005 and before January 1, 2010
4 | Class A refrigerated beverage vending machines | Edaily ≤ 0.00194 × V + 2.56Must be capable of operating in standby mode | On or after August 31, 2012 and before January 8, 2019
5 | Class B refrigerated beverage vending machines | Edaily ≤ 0.00258 × V + 3.16Must be capable of operating in standby mode | On or after August 31, 2012 and before January 8, 2019
6 | Class A refrigerated beverage vending machines | Edaily ≤ 0.00184 x V + 2.43 | On or after January 8, 2019
7 | Class B refrigerated beverage vending machines | Edaily ≤ 0.00184 x V + 2.20 | On or after January 8, 2019
8 | Combination A combination vending machines | Edaily ≤ 0.00304 x V + 2.66 | On or after January 8, 2019
9 | Combination B combination vending machines | Edaily ≤ 0.00392 x V + 2.04 | On or after January 8, 2019