Contents
- Whereas, pursuant to section 26 of the Energy Efficiency A…
- Interpretation
- Part 1 General
- Part 2 Energy-Using Products
- Schedule 1 / ANNEXE 1 Explanation for Elements on Household Appliance Energy Efficiency Label / Explication du contenu de l’étiquette indiquant l’efficacité énergétique des appareils domestiques (Subsection 13(1) and section 35 / paragraphe 13(1) et article 35)
- Schedule 2 / ANNEXE 2 Explanation for Elements on Room Air Conditioner Energy Efficiency Label / Explication du contenu de l’étiquette indiquant l’efficacité énergétique des climatiseurs individuels (Paragraph 114(a) / alinéa 114a))
- Schedule 3 / ANNEXE 3 Explanation for Elements on Room Air Conditioner Energy Efficiency Label / Explication du contenu de l’étiquette indiquant l’efficacité énergétique des climatiseurs individuels (Paragraph 114(b) / alinéa 114b))
- Schedule 4 / ANNEXE 4 Explanation for Elements on Portable Air Conditioner Energy Efficiency Label / Explication du contenu de l’étiquette indiquant l’efficacité énergétique des climatiseurs portables (Section 147 / article 147)
Whereas, pursuant to section 26 of the Energy Efficiency Act, a copy of the proposed Energy Efficiency Regulations, 2016, substantially in the annexed form, was published in the Canada Gazette, Part I, on April 30, 2016;noteTherefore, His Excellency the Governor General in Council, on the recommendation of the Minister of Natural Resources, pursuant to sections 20 and 25 of the Energy Efficiency Act, makes the annexed Energy Efficiency Regulations, 2016.note
Interpretation
1Definitions#
(1)The following definitions apply in these Regulations.
Act means the Energy Efficiency Act. (Loi)
adhesive tag means a label that is attached to an energy-using product by at least two strips of adhesive that are located on opposite edges of the label. (étiquette adhésive)
CGA means the Canadian Gas Association. (ACG)
flap tag means a label whose top edge is attached to an energy-using product by one strip of adhesive. (vignette)
hang tag means a label that is attached to an energy-using product by material that is looped around a section of the product so that the label hangs freely from the product. (étiquette volante)
household means manufactured or sold primarily for use in a dwelling. (domestique)
IEC means the International Electrotechnical Commission. (CEI)
IEEE means the Institute of Electrical and Electronics Engineers. (IEEE)
IES means the Illuminating Engineering Society of North America. (IES)
mains power means an alternating current electric power source that is in a building and is less than or equal to a nominal 240-volt single-phase supply. (alimentation principale)
model number means, in respect of any model of an energy-using product, the designator that is assigned to that model for the purposes of these Regulations and that distinguishes it from similar models. (numéro de modèle)
NEMA means the National Electrical Manufacturers Association. (NEMA)
new Regulations [Repealed, SOR/2025-110, s. 1]
unique motor identifier means an identifier consisting of the information set out below, in the following sequence:
(a)the name of the manufacturer, in abbreviated form;
(b)the nominal power of the motor, expressed in kilowatts for an IEC design motor or in horsepower for a NEMA design motor;
(c)the number of poles; and
(d)a statement as to whether the motor is of open or enclosed construction. (identificateur unique du moteur)
(2)In these Regulations, a reference to an energy-using product is a reference to that product as defined in the Division or Subdivision associated with it.
(4)In these Regulations, a reference to a testing standard that is incorporated by reference does not include any test procedure waiver that may be set out in that standard.
1.1Standards and procedures of other jurisdiction incorporated by reference#
Despite these Regulations, if an energy efficiency standard or test procedure that is incorporated by reference in these Regulations as amended from time to time is a reference to a standard or test procedure set out in the laws of another jurisdiction and that standard or procedure is subsequently repealed or revoked in that other jurisdiction, the reference to the standard or procedure in these Regulations is deemed to be a reference to that standard or procedure as it read on the day before the day on which it was repealed or revoked and it continues to apply for the purposes of these Regulations.note
Part 1 · General
Interpretation
2Definitions#
The following definitions apply in this Part.
certification body means, in respect of an energy-using product, a body that is accredited by the Standards Council of Canada to operate a certification program in respect of the energy efficiency of the product. (organisme de certification)
verification mark means, in respect of an energy-using product, a mark that is
(a)issued by a certification body to signify that the body has
(i)determined that the product complies with the applicable energy efficiency standard, and
(ii)if the product is one for which information must be provided to the Minister for the purpose of subsection 5(1) of the Act, verified the information that is related to the product’s energy performance; or
(b)issued by a province to signify that the product complies with the province’s energy efficiency standard. (marque de vérification)
Verification Mark
4Verification mark#
(1)Subject to subsection (4), every energy-using product that, for the purpose of sale or lease, is shipped from one province to another or imported into Canada must be labelled with a verification mark that is issued by
(a)a certification body; or
(b)a province whose energy efficiency standard for the product is equivalent to or exceeds the energy efficiency standard prescribed for the product in these Regulations.
(2)The verification mark must be readily visible on the surface of the energy-using product. However, in respect of the following energy-using products, the verification mark may be on the exterior of the product’s package:
(a)[Repealed, SOR/2025-110, s. 2] (repealed)
(b)a general service lamp;
(c)[Repealed, SOR/2025-110, s. 2] (repealed)
(d)a general service fluorescent lamp;
(e)[Repealed, SOR/2025-110, s. 2] (repealed)
(f)a battery charger;
(g)an external power supply; and
(h)a faucet that is a replacement aerator.
(3)[Repealed, SOR/2025-110, s. 2] (repealed)
(4)An external power supply is not required to be labelled with a verification mark if
(a)it is labelled with a mark in accordance with the U.S. Department of Energy publication entitled “International Efficiency Marking Protocol for External Power Supplies”, as amended from time to time;
(b)a certification body has verified the information related to the product’s energy performance that is provided to the Minister for the purpose of subsection 5(1) of the Act; and
(c)it is labelled with the same model number as that used when the information was verified.
(5)[Repealed, SOR/2025-110, s. 2] (repealed)
note
Provision of Information
5Prescribed information#
(1)A dealer who, for the purpose of sale or lease, ships an energy-using product from one province to another or imports an energy-using product into Canada must, for the purpose of subsection 5(1) of the Act, provide the following information to the Minister:
(a)the name of the product as prescribed in these Regulations;
(b)the brand name of the product, if any;
(c)the product’s model number or, in the case of a motor, the product’s model number or unique motor identifier;
(d)the name of the product’s manufacturer;
(e)one of the following, namely,
(i)the name of the certification body or province whose verification mark will be on the product or its package, or
(ii)[Repealed, SOR/2025-110, s. 3] (repealed)
(iii)in the case of an external power supply, the name of the certification body referred to in paragraph 4(4)(b);
(iv)[Repealed, SOR/2025-110, s. 3] (repealed)
(g)information that indicates whether a mathematical model described in subsection (3) was used to generate any of the information provided under paragraph (f).
(2)The information must be provided electronically or by fax, hand delivery, courier or mail before the product is imported into Canada or shipped from one province to another.
(3)Despite any provision in these Regulations requiring that the information referred to in this section be collected in accordance with an identified standard, a dealer may instead provide the information as generated by a mathematical model that, by means of an engineering or statistical analysis or a computer simulation or model, emulates the manner in which the information is collected under the identified standard.
note
Information Pertaining to Imports
7Prescribed information#
(1)A dealer who, for the purpose of sale or lease, imports an energy-using product into Canada must, for the purpose of subsection 5(1) of the Act, provide the following information to the Minister:
(a)the name of the product as prescribed in these Regulations;
(b)the brand name of the product, if any;
(c)the product’s model number or, in the case of a motor, the product’s model number or unique motor identifier;
(d)the dealer’s address; and
(e)a statement as to whether the product is being imported
(i)for sale or lease in Canada without modification,
(ii)for sale or lease in Canada after being modified to comply with the applicable energy efficiency standard, or
(iii)for incorporation into any other product that is to be exported from Canada.
(1.1)However, the following energy-using products are not energy-using products for the purpose of subsection (1) if, at the time of their importation, they are incorporated into another product:
(a)a battery charger;
(b)an external power supply;
(c)a fluorescent lamp ballast;
(d)an electric motor; and
(e)a small electric motor.
(2)The information must be provided by including it in any customs invoice or commercial invoice that is required to be provided in respect of the energy-using product under subsection 6(1) of the Accounting for Imported Goods and Payment of Duties Regulations and must be provided before the product is released under the Customs Act.
note
Exemptions from Certain Provisions of the Act
8Exemption — product to be modified#
(1)A dealer is exempt from the application of paragraph 4(1)(a) of the Act if the dealer, for the purpose of modifying an energy-using product to comply with the applicable energy efficiency standard, ships the product from the province in which it was manufactured to another province or imports the product into Canada.
(2)The dealer must
(a)ensure that the product is brought into compliance with the applicable energy efficiency standard within 90 days after the day on which the product is shipped or imported;
(b)despite subsection 5(2), provide the information referred to in subsection 5(1) within 120 days after the day on which the product is shipped or imported; and
(c)if requested by the Minister, provide the Minister with any other information that is necessary to establish that the product has been brought into compliance with the applicable energy efficiency standard.
11Exemption — motors with same unique motor identifier#
A dealer is exempt from the application of section 5 of the Act in respect of a motor if
(a)the information has been provided in respect of a motor that has the same unique motor identifier; and
(b)the motor is at least as energy efficient as the motor for which the information was provided.
Specified Energy-Using Products
11.1Subsection 20.1(2) of Act#
The following energy-using products are specified for the purpose of subsection 20.1(2) of the Act:
(a)clothes dryers;
(b)clothes washers;
(c)integrated clothes washer-dryers;
(d)dishwashers;
(e)refrigerators and combination refrigerator-freezers;
(f)freezers;
(g)gas ranges;
(h)dehumidifiers;
(i)microwave ovens;
(j)miscellaneous refrigeration products;
(k)ceiling fans;
(l)room air conditioners;
(m)large air conditioners;
(n)packaged terminal air conditioners;
(o)single package central air conditioners;
(p)single package vertical air conditioners;
(q)split system central air conditioners;
(r)portable air conditioners;
(s)large heat pumps;
(t)packaged terminal heat pumps;
(u)single package central heat pumps;
(v)single package vertical heat pumps;
(w)split system central heat pumps;
(x)gas furnaces;
(y)oil-fired furnaces;
(z)electric furnaces;
(z.01)gas boilers;
(z.02)oil-fired boilers;
(z.03)electric boilers;
(z.04)gas-fired storage water heaters;
(z.05)oil-fired water heaters;
(z.06)electric water heaters;
(z.07)gas-fired instantaneous water heaters;
(z.08)general service lamps;
(z.09)[Repealed, SOR/2025-110, s. 5] (repealed)
(z.10)[Repealed, SOR/2025-110, s. 5] (repealed)
(z.11)general service fluorescent lamps;
(z.12)fluorescent lamp ballasts;
(z.13)metal halide lamp ballasts;
(z.14)torchieres;
(z.15)ceiling fan light kits;
(z.16)exit signs;
(z.17)traffic signal modules;
(z.18)pedestrian modules;
(z.19)external power supplies;
(z.20)battery chargers;
(z.201)line voltage thermostats;
(z.21)commercial refrigerators;
(z.22)commercial refrigerator-freezers;
(z.23)commercial freezers;
(z.24)refrigerated beverage vending machines;
(z.25)snack and refrigerated beverage vending machines;
(z.26)ice-makers;
(z.27)walk-in door assemblies;
(z.28)walk-in panels;
(z.29)walk-in refrigeration systems;
(z.30)dry-type transformers;
(z.31)electric motors;
(z.32)small electric motors;
(z.321)faucets;
(z.322)showerheads;
(z.33)commercial pre-rinse spray valves;
(z.34)clean water pumps;
(z.35)pool pumps; and
(z.36)air compressors.
note
Part 2 · Energy-Using Products
Division 1 — Household Appliances
Interpretation
12Definitions#
The following definitions apply in this Division.
10 C.F.R. Appendix D2 means Appendix D2 to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Clothes Dryers, as amended from time to time. (appendice D2 10 C.F.R.)
CSA C300-00 [Repealed, SOR/2019-163, s. 1]
CSA C300-12 means the CSA standard CAN/CSA-C300-12 entitled Energy Performance and Capacity of Household Refrigerators, Refrigerator-Freezers, Freezers and Wine Chillers. (CSA C300-12)
CSA C300-15 means the CSA standard CAN/CSA-C300-15 entitled Energy Performance and Capacity of Household Refrigerators, Refrigerator-Freezers, Freezers and Wine Chillers. (CSA C300-15)
CSA C358-03 means the CSA standard CAN/CSA-C358-03 entitled Energy Consumption Test Methods for Household Electric Ranges. (CSA C358-03)
CSA C360-03 means the CSA standard CAN/CSA-C360-03 entitled Energy Performance, Water Consumption and Capacity of Household Clothes Washers. (CSA C360-03)
CSA C360-13 means the CSA standard CAN/CSA-C360-13 entitled Energy Performance, Water Consumption and Capacity of Household Clothes Washers. (CSA C360-13)
CSA C361-12 [Repealed, SOR/2018-201, s. 5]
CSA C361-16 means the CSA standard CAN/CSA-C361-16 entitled Energy performance and drum volume of household electric clothes dryers. (CSA C361-16)
CSA C361-92 means the CSA standard CAN/CSA-C361-92 entitled Test Method for Measuring Energy Consumption and Drum Volume of Electrically Heated Household Tumble-Type Clothes Dryers. (CSA C361-92)
note
Labelling
13EnerGuide label#
(1)An energy-using product prescribed in any of Subdivisions A to G or K of this Division must be labelled in the form set out in Schedule 1.
(2)The label must be an adhesive tag, flap tag or hang tag that is attached to the product so that the tag is readily visible when the product is viewed from the front.
note
14Paper — adhesive and flap tags#
(1)The paper that is used for adhesive tags or flap tags must weigh, exclusive of the release liner and adhesive, not less than the equivalent of 26.31 kg (58 pounds) per 500 sheets measuring 63.5 cm (25 inches) by 96.52 cm (38 inches).
(2)The adhesive that is used to attach an adhesive tag or a flap tag to an energy-using product must
(a)render the tag easily removable from the product without the use of a tool or any liquid other than water; and
(b)have an adhesion capacity that is sufficient to prevent the tag from being dislodged from the product under normal handling conditions.
15Paper — hang tags#
(1)The paper that is used for hang tags must weigh not less than the equivalent of 49.9 kg (110 pounds) per 500 sheets measuring 64.77 cm (25.5 inches) by 77.47 cm (30.5 inches).
(2)The material that is used to attach a hang tag to an energy-using product must be of sufficient strength to ensure that when gradual pressure is applied to the tag by pulling it away from the product, the tag will tear before the material breaks.
Subdivision A — Clothes Dryers
16Definition of clothes dryer#
In this Subdivision, clothes dryer means a household tumble-type clothes dryer that is electrically operated.
17Size category#
For the purposes of these Regulations, the size category of a clothes dryer is
(a)compact, if it has a drum capacity of less than 125 L (4.4 cubic feet); or
(b)standard, if it has a drum capacity of 125 L (4.4 cubic feet) or more.
18Energy-using product#
(1)A clothes dryer is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 19, a clothes dryer is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
19Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to clothes dryers that are manufactured during the periods set out in column 3.
(2)A clothes dryer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a clothes dryer as defined in section 16. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C361-92 | CSA C361-92, Table 8.1 | On or after February 3, 1995 and before January 1, 20152 | CSA C361-16 or 10 C.F.R. Appendix D2 | CSA C361-16, Table 1 | On or after January 1, 2015
note
20Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a clothes dryer described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Clothes dryers manufactured on or after February 3, 1995 and before January 1, 2015 | CSA C361-92 | (a)size category;(b)nominal voltage;(c)capacity, in L, of clothes dryer’s drum;(d)annual energy consumption in kWh;(e)energy factor in kg/kWh; and(f)drying controls the product has, namely, timed, auto-temp or auto-moisture.2 | Clothes dryers manufactured on or after January 1, 2015 | CSA C361-16 or 10 C.F.R. Appendix D2 | (a)size category;(b)nominal voltage;(c)capacity, in L, of clothes dryer’s drum;(d)annual energy consumption in kWh;(e)combined energy factor in kg/kWh; and(f)drying controls the product has, namely, timed, auto-temp or auto-moisture.note
Subdivision B — Clothes Washers
21Definition of clothes washer#
In this Subdivision, clothes washer means an electrically operated clothes washer that does not require mechanical fastening to a floor or wall, is top- or front-loaded and has an internal control system that regulates the water temperature without the need for user intervention after the machine is set in operation.
22Size category#
For the purposes of these Regulations, the size category of a clothes washer is
(a)compact, if it has a container capacity of less than 45 L (1.6 cubic feet); or
(b)standard, if it has a container capacity of 45 L (1.6 cubic feet) or more.
23Energy-using product#
(1)A clothes washer is prescribed as an energy-using product.
(2)However, a clothes washer is not considered to be an energy-using product
(b)for the purposes of sections 13 to 15, unless it is a household clothes washer and it is manufactured on or after February 3, 1995.
24Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to clothes washers described in column 1 that are manufactured during the periods set out in column 4.
(2)A clothes washer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a clothes washer as defined in section 21. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Clothes washers | CSA C360-03 | CSA C360-03, Table 9 | On or after February 3, 1995 and before January 1, 20072 | Clothes washers, other than household clothes washers | CSA C360-03 | CSA C360-03, Table 10 | On or after January 1, 2007 and before January 8, 20133 | Clothes washers, other than household clothes washers | CSA C360-03 | CSA C360-13, Table 11 | On or after January 8, 2013 and before January 1, 20184 | Clothes washers that are top-loaded, other than household clothes washers | CSA C360-13 | Modified energy factor ≥ 38.23 L/kWh/cycleIntegrated water consumption factor ≤ 1.18 L/cycle/L | On or after January 1, 20185 | Clothes washers that are front-loaded, other than household clothes washers | CSA C360-13 | Modified energy factor ≥ 56.63 L/kWh/cycleIntegrated water consumption factor ≤ 0.55 L/cycle/L | On or after January 1, 20186 | Household clothes washers | CSA C360-03 | CSA C360-03, Table 10 | On or after January 1, 2007 and before March 7, 20157 | Household clothes washers | CSA C360-13 | CSA C360-13, Table 9 | On or after March 7, 2015 and before January 1, 20188 | Household clothes washers | CSA C360-13 | CSA C360-13, Table 10 | On or after January 1, 2018
note
25Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a clothes washer described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Clothes washers manufactured on or after February 3, 1995 and before March 7, 2015 | CSA C360-03 | (a)size category;(b)capacity, in L, of clothes washer’s container;(c)annual energy consumption in kWh;(d)modified energy factor in L/kWh/cycle;(e)water consumption factor in L/cycle/L;(f)maximum wash temperature available, namely, ≤ 57.2°C or > 57.2°C;(g)the wash/rinse temperature selections listed in Table 5 of CSA C360-03 the product has;(h)water fill control system the product has, namely, manual or adaptive;(i)rotational axis of clothes washer’s container, namely, horizontal or vertical; and(j)method for payment the product has, if any.2 | Household clothes washers manufactured on or after March 7, 2015 | CSA C360-13 | (a)size category;(b)capacity, in L, of clothes washer’s container;(c)annual energy consumption in kWh;(d)integrated modified energy factor in L/kWh/cycle;(e)integrated water consumption factor in L/cycle/L;(f)maximum wash temperature available, namely, ≤ 57.2°C or > 57.2°C;(g)the wash/rinse temperature selections listed in Table 5 of CSA C360-13 the product has;(h)water fill control system the product has, namely, manual or adaptive; and(i)rotational axis of clothes washer’s container, namely, horizontal or vertical.3 | Clothes washers, other than household clothes washers, manufactured on or after March 7, 2015 and before January 1, 2018 | CSA C360-03 | (a)size category;(b)capacity, in L, of clothes washer’s container;(c)annual energy consumption in kWh;(d)modified energy factor in L/kWh/cycle;(e)water consumption factor in L/cycle/L;(f)maximum wash temperature available, namely, ≤ 57.2°C or > 57.2°C;(g)the wash/rinse temperature selections listed in Table 5 of CSA C360-03 the product has;(h)water fill control system the product has, namely, manual or adaptive;(i)rotational axis of clothes washer’s container, namely, horizontal or vertical; and(j)method for payment the product has, if any.4 | Clothes washers, other than household clothes washers, manufactured on or after January 1, 2018 | CSA C360-13 | (a)size category;(b)capacity, in L, of clothes washer’s container;(c)annual energy consumption in kWh;(d)modified energy factor in L/kWh/cycle;(e)integrated water consumption factor in L/cycle/L;(f)maximum wash temperature available, namely, ≤ 57.2°C or > 57.2°C;(g)the wash/rinse temperature selections listed in Table 5 of CSA C360-13 the product has;(h)water fill control system the product has, namely, manual or adaptive;(i)rotational axis of clothes washer’s container, namely, horizontal or vertical; and(j)method for payment the product has, if any.note
Subdivision C — Integrated Clothes Washer-Dryers
26Definitions#
The following definitions apply in this Subdivision.
combination clothes washer-dryer means a household appliance that has
(a)a clothes washer function and clothes dryer function that utilize the same drum;
(b)a common control panel for both functions; and
(c)one power source. (laveuse-sécheuse combinée)
V means
(a)in the case of an integrated clothes washer-dryer that is not a combination clothes washer-dryer, the volumes, expressed in litres, of the basket for the clothes washer component and of the drum for the clothes dryer component; or
(b)in the case of an integrated clothes washer-dryer that is a combination clothes washer-dryer, the volume, expressed in litres, of the drum. (V)
27Size category — other than combination clothes washer-dryer#
(1)For the purposes of these Regulations, the size category of an integrated clothes washer-dryer that is not a combination clothes washer-dryer is
(a)compact, if it has a clothes dryer component with a drum capacity of less than 125 L (4.4 cubic feet) and a clothes washer component with a basket capacity of less than 45 L (1.6 cubic feet); or
(b)standard, if it has a clothes dryer component with a drum capacity of 125 L (4.4 cubic feet) or more and a clothes washer component with a basket capacity of 45 L (1.6 cubic feet) or more.
(2)For the purposes of these Regulations, the size category of an integrated clothes washer-dryer that is a combination clothes washer is
(a)compact, if it has a drum capacity of less than 45 L (1.6 cubic feet); or
(b)standard, if it has a drum capacity of 45 L (1.6 cubic feet) or more.
28Type#
For the purposes of these Regulations, an integrated clothes washer-dryer is one of the following types, namely, combination, over/under or side-by-side.
29Energy-using product#
(1)An integrated clothes washer-dryer is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 30, an integrated clothes washer-dryer is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
30Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to integrated clothes washer-dryers that are manufactured during the periods set out in column 3.
(2)An integrated clothes washer-dryer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to an integrated clothes washer-dryer as defined in section 26. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C360-03 for clothes washer functionCSA C361-92 for clothes dryer function | CSA C360-03, Table 9, for clothes washer functionCSA C361-92, Table 8.1, for clothes dryer function | On or after February 3, 1995 and before January 1, 20072 | CSA C360-03 for clothes washer functionCSA C361-92 for clothes dryer function | CSA C360-03, Table 10, for clothes washer functionCSA C361-92, Table 8.1, for clothes dryer function | On or after January 1, 2007 and before March 7, 20153 | CSA C360-13 for clothes washer functionCSA C361-16 or 10 C.F.R. Appendix D2 for clothes dryer function | CSA C360-13, Table 9, for clothes washer functionCSA C361-16, Table 1, for clothes dryer function | On or after March 7, 2015 and before January 1, 20184 | CSA C360-13 for clothes washer functionCSA C361-16 or 10 C.F.R. Appendix D2 for clothes dryer function | CSA C360-13, Table 10, for clothes washer functionCSA C361-16, Table 1, for clothes dryer function | On or after January 1, 2018
note
31Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an integrated clothes washer-dryer described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Integrated clothes washer-dryers manufactured on or after February 3, 1995 and before March 7, 2015 | CSA C360-03 for clothes washer functionCSA C361-92 for clothes dryer function | (a)type and size category;(b)V;(c)annual energy consumption, in kWh, for clothes washer function and clothes dryer function;(d)modified energy factor in L/kWh/cycle for clothes washer function;(e)energy factor in kg/kWh for clothes dryer function;(f)water consumption factor in L/cycle/L;(g)maximum water temperature available, namely, ≤ 57.2°C or > 57.2°C;(h)which of the wash/rinse temperature selections listed in Table 5 of CSA C360-03 the product has;(i)water fill control system the product has, namely, manual or adaptive; and(j)drying controls the product has, namely, timed, auto-temp or auto-moisture.2 | Integrated clothes washer-dryers manufactured on or after March 7, 2015 | CSA C360-13 for clothes washer functionCSA C361-16 or 10 C.F.R. Appendix D2 for clothes dryer function | (a)type and size category;(b)V;(c)annual energy consumption, in kWh, for clothes washer function and clothes dryer function;(d)integrated modified energy factor in L/kWh/cycle for clothes washer function;(e)combined energy factor in kg/kWh for clothes dryer function;(f)integrated water consumption factor in L/cycle/L;(g)maximum water temperature available, namely, ≤ 57.2°C or > 57.2°C;(h)which of the wash/rinse temperature selections listed in Table 5 of CSA C360-13 the product has;(i)water fill control system the product has, namely, manual or adaptive; and(j)drying controls the product has, namely, timed, auto-temp or auto-moisture.note
Subdivision D — Dishwashers
32Definitions#
The following definitions apply in this Subdivision.
CSA C373-04 means the CSA standard CAN/CSA-C373-04 entitled Energy Consumption Test Methods and Limits for Household Dishwashers. (CSA C373-04)
CSA C373-14 means the CSA standard CAN/CSA-C373-14 entitled Energy Performance and Water Consumption of Household Dishwashers. (CSA C373-14)
dishwasher means an electrically operated automatic household dishwasher. (lave-vaisselle)
33Size category#
For the purposes of these Regulations, the size category of a dishwasher is
(a)compact, if it has a capacity of less than eight place settings and six serving pieces; or
(b)standard, if it has a capacity that is equal to or greater than eight place settings and six serving pieces.
34Type#
For the purposes of these Regulations, a dishwasher is one of the following types:
(a)built-in, if it is designed to be permanently connected to a water and electric supply in a dwelling; or
(b)portable, if it is designed not to be permanently connected to a water and electric supply in a dwelling.
35Labelling — total annual energy consumption#
In respect of a dishwasher that is manufactured on or after January 1, 2010, a reference to “annual energy consumption” in Schedule 1 is to be read as a reference to “total annual energy consumption”.
36Energy-using product#
(1)A dishwasher is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 37, a dishwasher is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
37Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to dishwashers described in column 1 that are manufactured during the periods set out in column 4.
(2)A dishwasher complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a dishwasher as defined in section 32. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Dishwashers | CSA C373-04 | CSA C373-04, Table 2 | On or after February 3, 1995 and before January 1, 20102 | Dishwashers that are standard | CSA C373-04 | Total annual energy consumption ≤ 355 kWh | On or after January 1, 2010 and before May 30, 20133 | [Repealed, SOR/2018-201, s. 11]4 | Dishwashers that are compact | CSA C373-04 | Total annual energy consumption ≤ 260 kWh | On or after January 1, 2010 and before May 30, 20135 | Dishwashers | CSA C373-14 | CSA C373-14, Table 2 | On or after May 30, 2013
note
38Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected and provided to the Minister in respect of a dishwasher described in column 1 and, if applicable, the information must be collected in accordance with the standard set out in column 2. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Dishwashers manufactured on or after February 3, 1995 and before January 1, 2010 | CSA C373-04, for information set out in paragraphs (b) to (d) | (a)type and size category;(b)volume, in L, of hot water used;(c)annual energy consumption in kWh;(d)energy factor in cycles/kWh; and(e)drying option the product has, namely, heat dry or heat on/heat off.2 | Dishwashers manufactured on or after January 1, 2010 and before May 30, 2013 | CSA C373-04, for information set out in paragraphs (b) to (e) | (a)type and size category;(b)volume, in L, of hot water used;(c)total annual energy consumption in kWh;(d)annual standby energy consumption in kWh;(e)energy factor in cycles/kWh; and(f)drying option the product has, namely,(i)power-dry with fan and heat on,(ii)power-dry with fan on and heat off, or(iii)power-dry off.3 | Dishwashers manufactured on or after May 30, 2013 | CSA C373-14, for information set out in paragraphs (b) to (d) and (f) | (a)type and size category;(b)volume, in L, of hot water used;(c)total annual energy consumption in kWh;(d)annual standby energy consumption in kWh;(e)drying option the product has, namely,(i)power-dry with fan and heat on,(ii)power-dry with fan on and heat off, or(iii)power-dry off; and(f)water consumption factor in L/cycle.note
Subdivision E — Refrigerators and Combination Refrigerator-Freezers
39Definitions#
The following definitions apply in this Subdivision.
combination refrigerator-freezer means a household combination refrigerator-freezer that has a defrost system, including a compressor-cycled automatic defrost system and a capacity of 1 105 L (39 cubic feet) or less. (réfrigérateur-congélateur)
compressor-cycled automatic defrost system means a defrost system in which the defrosting action for the refrigerated spaces occurs using the natural warming of the evaporator and that is automatically initiated when the compressor is cycled on and automatically terminated when the compressor is cycled off. (dispositif de dégivrage automatique à cycle du compresseur)
refrigerator means a household refrigerator that has a capacity of 1 105 L (39 cubic feet) or less and that has a defrost system, including a compressor-cycled automatic defrost system. It does not include
(a)a household refrigerator that uses an absorption refrigeration system; or
(b)a miscellaneous refrigeration product. (réfrigérateur)
Type 5A combination refrigerator-freezer [Repealed, SOR/2019-163, s. 3]
note
40Size category#
For the purposes of these Regulations, the size category of a refrigerator or combination refrigerator-freezer is the capacity range set out below within which the actual size of the product falls or that is closest to the actual size of the product:
(a)less than 70 L (2.5 cubic feet);
(b)70 to 126 L (2.5 to 4.4 cubic feet);
(c)127 to 182 L (4.5 to 6.4 cubic feet);
(d)183 to 239 L (6.5 to 8.4 cubic feet);
(e)240 to 295 L (8.5 to 10.4 cubic feet);
(f)296 to 352 L (10.5 to 12.4 cubic feet);
(g)353 to 409 L (12.5 to 14.4 cubic feet);
(h)410 to 465 L (14.5 to 16.4 cubic feet);
(i)466 to 522 L (16.5 to 18.4 cubic feet);
(j)523 to 579 L (18.5 to 20.4 cubic feet);
(k)580 to 635 L (20.5 to 22.4 cubic feet);
(l)636 to 692 L (22.5 to 24.4 cubic feet);
(m)693 to 748 L (24.5 to 26.4 cubic feet);
(n)749 to 805 L (26.5 to 28.4 cubic feet);
(o)806 to 862 L (28.5 to 30.4 cubic feet); or
(p)863 to 1 105 L (30.5 to 39.0 cubic feet).
note
41Type#
For the purposes of these Regulations, a refrigerator or combination refrigerator-freezer is one of the product types (1) to (7-BI) and (11) to (15I) of Table 1 to CSA C300-15.note
42Energy-using products#
(1)Refrigerators and combination refrigerator-freezers are prescribed as energy-using products.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 43, a refrigerator or combination refrigerator-freezer is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
43Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to refrigerators and combination refrigerator-freezers described in column 1 that are manufactured during the periods set out in column 4.
(2)A refrigerator complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a refrigerator as defined in section 39.
(3)A combination refrigerator-freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a combination-refrigerator freezer as defined in section 39.Item | Column 1 | Column 2 | Column 3 | Column 4Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Refrigerators and combination refrigerator-freezers | CSA C300-12 | CSA C300-12, Table 1 | On or after February 3, 1995 and before September 15, 20142 | Refrigerators and combination refrigerator-freezers | CSA C300-15 | CSA C300-15, Table 1 | On or after September 15, 2014
note
44Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a refrigerator or combination refrigerator-freezer:
(a)its type;
(b)the volume of its fresh food compartment;
(c)the volume of its freezer compartment, if any;
(d)its adjusted volume; and
(e)its annual energy consumption, expressed in kilowatt hours.
(2)The information must be collected in accordance with one of the following standards:
(a)CSA C300-12, if the product was manufactured on or after February 3, 1995 and before September 15, 2014; or
(b)CSA C300-15, if the product is manufactured on or after September 15, 2014.
(c)[Repealed, SOR/2019-163, s. 7] (repealed)
note
Subdivision F — Freezers
45Definition of freezer#
In this Subdivision, freezer means a household freezer that has a capacity of 850 L (30 cubic feet) or less.note
46Size category#
For the purposes of these Regulations, the size category of a freezer is the capacity range set out below within which the actual size of the product falls or that is closest to the actual size of the product:
(a)less than 155 L (5.5 cubic feet);
(b)155 to 210 L (5.5 to 7.4 cubic feet);
(c)211 to 267 L (7.5 to 9.4 cubic feet);
(d)268 to 324 L (9.5 to 11.4 cubic feet);
(e)325 to 380 L (11.5 to 13.4 cubic feet);
(f)381 to 437 L (13.5 to 15.4 cubic feet);
(g)438 to 494 L (15.5 to 17.4 cubic feet);
(h)495 to 550 L (17.5 to 19.4 cubic feet);
(i)551 to 607 L (19.5 to 21.4 cubic feet);
(j)608 to 664 L (21.5 to 23.4 cubic feet);
(k)665 to 720 L (23.5 to 25.4 cubic feet);
(l)721 to 777 L (25.5 to 27.4 cubic feet);
(m)778 to 833 L (27.5 to 29.4 cubic feet); or
(n)834 to 850 L (29.5 to 30.0 cubic feet).
note
47Type#
For the purposes of these Regulations, a freezer is one of the types described in the product types (8) to (10A) and (16) to (18) of Table 1 to CSA C300-15.note
48Energy-using product#
(1)A freezer is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 49, a freezer is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
49Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to freezers described in column 1 that are manufactured during the periods set out in column 4.
(2)A freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a freezer as defined in section 45.Item | Column 1 | Column 2 | Column 3 | Column 4Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Freezers | CSA C300-12 | CSA C300-12, Table 1 | On or after February 3, 1995 and before September 15, 20142 | Freezers | CSA C300-15 | CSA C300-15, Table 1 | On or after September 15, 2014
note
50Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a freezer:
(a)its type;
(b)its total refrigerated volume;
(c)its adjusted volume;
(d)its annual energy consumption, expressed in kilowatt hours; and
(e)its ice freezing capacity, expressed in kilograms per 24 hours.
(2)The information must be collected in accordance with one of the following standards:
(a)CSA C300-12, if the product was manufactured on or after February 3, 1995 and before September 15, 2014; or
(b)CSA C300-15, if the product is manufactured on or after September 15, 2014.
(c)[Repealed, SOR/2019-163, s. 12] (repealed)
Subdivision G — Electric Ranges
51Definitions#
The following definitions apply in this Subdivision.
conventional cooking top means a cooking top that is not a modular cooking top. (table de cuisson traditionnelle)
E means energy consumption, expressed in kilowatt hours per month. (E)
electric range means a household electric range. It does not include a portable range that is designed for an electrical supply of 120 V or a microwave oven. (cuisinière électrique)
modular cooking top means a cartridge that consists of at least one surface element and that can be plugged into a receptacle on the surface of an electric range. (table de cuisson modulaire)
52Size category#
For the purposes of these Regulations, the size category of an electric range that has at least one surface element and at least one oven is one of the following, based on the product’s exterior width:
(a)60.96 cm (24 inches);
(b)76.2 cm (30 inches);
(c)91.44 cm (36 inches); or
(d)121.92 cm (48 inches).
53Type#
For the purposes of these Regulations, an electric range is one of the following types:
(a)if it has at least one oven, either self-cleaning or non-self-cleaning; and
(b)if it has no oven, all models.
54Energy-using product#
(1)An electric range is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 55, an electric range is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
55Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to electric ranges described in column 1 that are manufactured during the periods set out in column 3.
(2)An electric range complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C358-03 that are applicable to an electric range as defined in section 51. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Energy Efficiency Standard | Period of Manufacture1 | Electric ranges that have at least one surface element and at least one oven | E ≤ 0.93 V + 14.3 | On or after February 3, 1995 and before August 1, 20032 | Electric ranges that have at least one surface element and at least one oven | CSA C358-03, clause 8(a) | On or after August 1, 20033 | Electric ranges that have at least one oven but no surface elements | E ≤ 38 | On or after February 3, 1995 and before August 1, 20034 | Electric ranges that have at least one oven but no surface elements | CSA C358-03, clause 8(c) | On or after August 1, 20035 | Electric ranges that are counter-mounted and have at least one surface element on a conventional cooking top but have no oven | E ≤ 34 | On or after February 3, 1995 and before August 1, 20036 | Electric ranges that are counter-mounted and have at least one surface element on a modular cooking top but have no oven | E ≤ 43 | On or after February 3, 1995 and before August 1, 20037 | Electric ranges that are counter-mounted and have at least one surface element but have no oven | CSA C358-03, clause 8(b) | On or after August 1, 2003
56Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 2 of the table to this section must be collected in accordance with CSA C358-03 and provided to the Minister in respect of an electric range described in column 1. | Column 1 | Column 2Item | Energy-using Product | Information1 | Electric ranges that have at least one surface element and at least one oven and that were manufactured on or after February 3, 1995 and before August 1, 2003 | (a)type and size category;(b)volume, in L, of usable oven space;(c)annual energy consumption in kWh;(d)cooking top the product has, namely, conventional or modular; and(e)information that indicates whether product is free-standing or built-in.2 | Electric ranges that have at least one surface element and at least one oven and that are manufactured on or after August 1, 2003 | (a)type and size category;(b)volume, in L, of usable oven space;(c)annual energy consumption in kWh;(d)oven configuration, namely, single oven or double oven;(e)baking mode the product has, namely, normal bake or normal bake with forced convection;(f)information that indicates whether product is free-standing or built-in; and(g)annual clock energy consumption in kWh.3 | Electric ranges that have at least one oven but no surface element and that were manufactured on or after February 3, 1995 and before August 1, 2003 | (a)volume, in L, of usable oven space for each oven;(b)annual energy consumption in kWh;(c)oven configuration, namely, single oven, double oven or double oven with microwave upper oven; and(d)information that indicates whether product is built-in or wall-mounted.4 | Electric ranges that have at least one oven but no surface element and that are manufactured on or after August 1, 2003 | (a)type;(b)volume, in L, of usable oven space for each oven;(c)exterior oven width;(d)annual energy consumption in kWh;(e)oven configuration, namely, single oven, double oven or double oven with microwave upper oven;(f)baking mode the product has, namely, normal bake or normal bake with forced convection;(g)information that indicates whether product is built-in or wall-mounted; and(h)annual clock energy consumption in kWh.5 | Electric ranges that are counter-mounted, have at least one surface element but no oven and were manufactured on or after February 3, 1995 and before August 1, 2003 | (a)annual energy consumption in kWh; and(b)cooking top configuration, namely, conventional or modular.6 | Electric ranges that are counter-mounted, have at least one surface element but no oven and are manufactured on or after August 1, 2003 | (a)annual energy consumption in kWh;(b)exterior oven width; and(c)annual clock energy consumption in kWh.
Subdivision H — Gas Ranges
57Definition of gas range#
In this Subdivision, gas range means a household propane or natural gas range that has an electrical power source, is used for food preparation and provides at least one of the following functions:
(a)surface cooking;
(b)oven cooking; and
(c)broiling.
58Energy-using product#
(1)A gas range is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 59, a gas range is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
59Energy efficiency standard#
The energy efficiency standard that applies to a gas range is that it must not have a continuously burning pilot light.
60Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C358-03 and provided to the Minister in respect of a gas range:
(a)the volume of usable oven space, expressed in litres;
(b)information that indicates whether the product is built-in or free-standing; and
(c)the broiler configuration, namely, open or closed.
Subdivision I — Dehumidifiers
61Definitions#
The following definitions apply in this Subdivision.
CSA C749-07 means the CSA standard CAN/CSA-C749-07 entitled Performance of Dehumidifiers. (CSA C749-07)
CSA C749-94 means the CSA standard CAN/CSA-C749-94 entitled Performance of Dehumidifiers. (CSA C749-94)
dehumidifier means a household appliance that is primarily designed to remove moisture from the air and is
(a)self-contained and encased;
(b)electrically operated; and
(c)mechanically refrigerated. (déshumidificateur)
portable dehumidifier means a dehumidifier that is not a whole-home dehumidifier. (déshumidificateur portatif)
10 C.F.R. Appendix X1 means Appendix X1 to Subpart B of Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Dehumidifiers, as amended from time to time. (appendice X1 10 C.F.R.)
10 C.F.R. §430.32(v)(2) means the table to paragraph 430.32(v)(2) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(v)(2))
whole-home dehumidifier means a dehumidifier that is designed to be installed in an air duct. (déshumidificateur à conduit)
note
62Energy-using product#
(1)A dehumidifier is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 63, a dehumidifier is not considered to be an energy-using product unless
(a)it is manufactured on or after December 31, 1998; and
(b)in the case of a whole-home dehumidifier, it is manufactured on or after June 13, 2019.
note
63Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to dehumidifiers described in column 1 that are manufactured during the periods set out in column 4.
(2)A dehumidifier complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a dehumidifier as defined in section 61. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Dehumidifiers | CSA C749-94 | CSA C749-94, clause 4.2 | On or after December 31, 1998 and before October 1, 20072 | Dehumidifiers | CSA C749-07 | CSA C749-07, Table 1 | On or after October 1, 2007 and before October 1, 20123 | Dehumidifiers | CSA C749-07 | CSA C749-07, Table 1B | On or after October 1, 2012 and before June 13, 20194 | Portable dehumidifiers | 10 C.F.R. Appendix X1 | Minimum integrated energy factor applicable, based on product’s capacity, as set out in 10 C.F.R. §430.32(v)(2) | On or after June 13, 20195 | Whole-home dehumidifiers | 10 C.F.R. Appendix X1 | Minimum integrated energy factor applicable, based on product’s case volume, as set out in 10 C.F.R. §430.32(v)(2) | On or after June 13, 2019
note
64Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a dehumidifier described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Dehumidifiers manufactured before October 1, 2007 | CSA C749-94 | (a)water removal capacity, in L/day; and(b)energy factor, in L/kWh.2 | Dehumidifiers manufactured on or after October 1, 2007 and before June 13, 2019 | CSA C749-07 | (a)water removal capacity, in L/day;(b)energy factor, in L/kWh; and(c)standby power, in watts.3 | Dehumidifiers manufactured on or after June 13, 2019 | 10 C.F.R. Appendix X1 | (a)if product is a portable dehumidifier, water removal capacity, in L/day;(b)if product is a whole-home dehumidifier, case volume in litres (cubic feet);(c)integrated energy factor, in L/kWh; and(d)standby power, in watts.note
Subdivision J — Microwave Ovens
65Definitions#
The following definitions apply in this Subdivision.
CSA C388-15 means the CSA standard CAN/CSA-C388-15 entitled Energy performance and capacity measurement of household microwave ovens. (CSA C388-15)
microwave oven means a household cooking appliance that is designed to cook or heat food in a compartment by means of microwave energy and includes one that has a thermal element that is designed for the surface browning of food. (four à micro-ondes)
10 C.F.R. Appendix I means Appendix I to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Microwave Ovens, as amended from time to time. (appendice I 10 C.F.R.)
10 C.F.R. §430.32(j)(3) means paragraph 430.32(j)(3) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(j)(3))
note
66Type#
For the purposes of these Regulations, a microwave oven is one of the following types:
(a)microwave-only oven;
(b)countertop convection microwave oven;
(c)built-in convection microwave oven; or
(d)over-the-range convection microwave oven.
note
67Energy-using product#
(1)A microwave oven is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 68, a microwave oven is not considered to be an energy-using product unless it is manufactured on or after March 31, 2019.
note
68Energy efficiency standard#
(1)The energy efficiency standard for a microwave oven is the standard set out for that type of microwave oven in 10 C.F.R. §430.32(j)(3).
(2)A microwave oven complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C388-15 or 10 C.F.R. Appendix I that are applicable to a microwave oven as defined in section 65.
note
69Information#
For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a microwave oven:
(a)its type;
(b)its volume, expressed in litres (cubic feet); and
(c)its standby power, expressed in watts, as collected in accordance with CSA C388-15 or 10 C.F.R. Appendix I.
note
Subdivision K — Miscellaneous Refrigeration Products
70Definitions#
The following definitions apply in this Subdivision.
10 C.F.R. Appendix A means Appendix A to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Refrigerators, Refrigerator-Freezers, and Miscellaneous Refrigeration Products, as amended from time to time. (appendice A 10 C.F.R.)
10 C.F.R. §430.32(aa)(1) means the table to paragraph 430.32(aa)(1) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(aa)(1))
10 C.F.R. §430.32(aa)(2) means the table to paragraph 430.32(aa)(2) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(aa)(2))
miscellaneous refrigeration product means a household refrigeration product, which includes a cooler and combination cooler refrigeration product, but does not include a refrigerator, refrigerator-freezer or freezer. (appareil de réfrigération divers)
note
71Type#
For the purposes of these Regulations, a miscellaneous refrigeration product is one of the following types:
(a)if it was manufactured on or after January 1, 2008 and before October 28, 2019, a type described in any of the product types (19) or (20) of Table 1 to CSA C300-15; or
(b)if it is manufactured on or after October 28, 2019, a cooler of a product class described in 10 C.F.R. §430.32(aa)(1) or a combination cooler refrigeration product of a product class described in 10 C.F.R. §430.32(aa)(2).
note
72Energy-using product#
(1)A miscellaneous refrigeration product is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 13 to 15 and 73, a miscellaneous refrigeration product is not considered to be an energy-using product unless
(a)it is manufactured on or after January 1, 2008 and before October 28, 2019, and is a type (19) or (20) as described in Table 1 to CSA C300-15; or
(b)it is manufactured on or after October 28, 2019.
note
73Energy efficiency standard#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to miscellaneous refrigeration products described in column 1 that are manufactured during the periods set out in column 4.
(2)A miscellaneous refrigeration product complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a miscellaneous refrigeration product as defined in section 70.Item | Column 1 | Column 2 | Column 3 | Column 4Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Miscellaneous refrigeration products | CSA C300-12 | CSA C300-12, Table 1 | On or after January 1, 2008 and before September 15, 20142 | Miscellaneous refrigeration products | CSA C300-15 | CSA C300-15, Table 1 | On or after September 15, 2014 and before October 28, 20193 | Miscellaneous refrigeration products – coolers | 10 C.F.R. Appendix A | 10 C.F.R. §430.32(aa)(1) | On or after October 28, 20194 | Miscellaneous refrigeration products – combination cooler refrigeration products | 10 C.F.R. Appendix A | 10 C.F.R. §430.32(aa)(2) | On or after October 28, 2019
note
74Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a miscellaneous refrigeration product:
(a)its type;
(b)its adjusted volume; and
(c)its annual energy consumption expressed in kilowatt-hours.
(2)The information must be collected in accordance with one of the following standards:
(a)CSA C300-12 if the product was manufactured on or after January 1, 2008 and before September 15, 2014;
(b)CSA C300-15 if the product was manufactured on or after September 15, 2014 and before October 28, 2019; or
(c)10 C.F.R. Appendix A if the product is manufactured on or after October 28, 2019.
note
Subdivision L — Ceiling Fans
75Definitions#
The following definitions apply in this Subdivision.
10 C.F.R. Appendix U means Appendix U to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans, as amended from time to time. (appendice U 10 C.F.R.)
10 C.F.R. §430.32(s)(2)(i) means the table to subparagraph 430.32(s)(2)(i) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(s)(2)(i))
ceiling fan means a non-portable device that is suspended from a ceiling for circulating air via the rotation of fan blades. It does not include
(a)a ceiling fan if the plane of rotation of the fan blades is greater than 45 degrees from horizontal;
(b)a centrifugal ceiling fan;
(c)a belt-driven ceiling fan;
(d)an oscillating ceiling fan; and
(e)a ceiling fan with a maximum rotational speed of 90 RPM and a maximum airflow of 52.1 cubic metres/minute (1840 cubic feet/minute). (ventilateur de plafond)
note
76Type#
For the purposes of these Regulations, a ceiling fan is one of the following types:
(a)very small diameter;
(b)standard;
(c)hugger;
(d)high-speed small-diameter; or
(e)large-diameter.
note
77Energy-using product#
(1)A ceiling fan is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 78, a ceiling fan is not considered to be an energy-using product unless it is manufactured on or after January 21, 2020.
note
78Energy efficiency standard#
(1)The energy efficiency standard for a ceiling fan is the standard as set out in 10 C.F.R. §430.32(s)(2)(i).
(2)A ceiling fan complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix U that are applicable to a ceiling fan as defined in section 75.
note
79Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix U and provided to the Minister in respect of a ceiling fan:
(a)its type;
(b)its blade span;
(c)its air flow at high speed;
(d)its ceiling fan efficiency; and
(e)its standby power consumption expressed in watts.
note
Division 2 — Air Conditioners, Condensing Units and Chillers
Interpretation
107Definitions#
The following definitions apply in this Division.
CSA C656-05 means the CSA standard CAN/CSA-C656-05 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-05)
CSA C656-14 means the CSA standard CSA-C656-14 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-14)
CSA C746-06 means the CSA standard CAN/CSA-C746-06 entitled Performance Standard for Rating Large and Single Packaged Vertical Air Conditioners and Heat Pumps. (CSA C746-06)
CSA C746-98 means the CSA standard CAN/CSA-C746-98 entitled Performance Standard for Rating Large Air Conditioners and Heat Pumps. (CSA C746-98)
small-duct and high-velocity, with respect to a single package central air conditioner or a split-system central air conditioner, means one that has an indoor blower and coil combination that
(a)produces at least 300 Pa (1.2 inches of water) external static pressure when operated at an air volume rate of 104 to 165 L/s (220 to 350 cubic feet/minute) per nominal ton of cooling; and
(b)uses room outlets that produce velocities greater than 5 m/s (1,000 feet/minute) and that each have an area less than 39 cm2 (6 square inches). (à grand débit et à petits conduits)
space-constrained, with respect to a single package central air conditioner or a split system central air conditioner, means one that
(a)has a cooling capacity that is less than or equal to 8.79 kW (30,000 Btu/h); and
(b)has an outdoor or indoor unit
(i)that has an overall displacement that is — or two or more overall exterior dimensions that are — substantially smaller than those of other units of a similar cooling capacity that are usually installed in single-family homes, and
(ii)with respect to which an increase in the overall displacement or two or more overall exterior dimensions would result in a considerable increase in the usual cost of installation or in a significant loss in the utility of the product to the consumer. (à espace restreint)
10 C.F.R. Appendix F1 means Appendix F1 to Subpart F, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Air-Cooled, Three-Phase, Small Commercial Package Air Conditioning and Heating Equipment With a Cooling Capacity of Less Than 65,000 Btu/h and Air-Cooled, Three-Phase, Variable Refrigerant Flow Multi-Split Air Conditioners and Heat Pumps With a Cooling Capacity of Less Than 65,000 Btu/h, as amended from time to time. (appendice F1 10 C.F.R.)
10 C.F.R. Appendix M means Appendix M to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M 10 C.F.R)
10 C.F.R. Appendix M1 means Appendix M1 to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M1 10 C.F.R.)
note
107.1Type#
For the purposes of these Regulations, a central air conditioner manufactured on or after January 1, 2023 is one of the following types:
(a)single package, other than space-constrained;
(b)space-constrained single package;
(c)split system, other than space-constrained or small-duct and high-velocity;
(d)small-duct and high-velocity split-system; or
(e)space-constrained split-system.
note
Subdivision A — Room Air Conditioners
108Definitions#
The following definitions apply in this Subdivision.
CEER [Repealed, SOR/2025-110, s. 8]
CSA C368.1 means the CSA standard CAN/CSA-C368.1-M90 entitled Performance Standard for Room Air Conditioners. (CSA C368.1)
CSA C368.1-14 [Repealed, SOR/2025-110, s. 8]
CSA C370 [Repealed, SOR/2019-163, s. 15]
CSA C62301 [Repealed, SOR/2025-110, s. 8]
off mode [Repealed, SOR/2018-201, s. 18]
on mode [Repealed, SOR/2018-201, s. 18]
portable air conditioner [Repealed, SOR/2019-163, s. 15]
room air conditioner means a single-phase electric air conditioner that has a cooling capacity of 10.55 kW (36,000 Btu/h) or less. It does not include a packaged terminal air conditioner, a portable air conditioner or a single package vertical air conditioner. (climatiseur individuel)
standby mode [Repealed, SOR/2018-201, s. 18]
note
109Type#
For the purposes of these Regulations, a room air conditioner is one of the following types:
(a)120 V louvred with reverse cycle;
(b)120 V louvred without reverse cycle;
(c)120 V non-louvred with reverse cycle;
(d)120 V non-louvred without reverse cycle;
(e)120 V casement-only;
(f)120 V casement-slider;
(g)240 V louvred with reverse cycle;
(h)240 V louvred without reverse cycle;
(i)240 V non-louvred with reverse cycle;
(j)240 V non-louvred without reverse cycle;
(k)240 V casement-only; or
(l)240 V casement-slider.
110Cooling capacity category#
For the purposes of these Regulations, the cooling capacity category of a room air conditioner is the applicable cooling capacity range set out in
(a)Table 2 of CSA C368.1, if the product was manufactured before June 1, 2014;
(c)Table 3 to Part 2 of TSD D2SA001, if the product is manufactured on or after May 26, 2026.
note
111Energy-using product#
(1)A room air conditioner is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 112, 114 and 115, a room air conditioner is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
note
112Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to room air conditioners that are manufactured during the periods set out in column 3.
(2)A room air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a room air conditioner as defined in section 108. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C368.1 | CSA C368.1, Table 2, second column | On or after February 3, 1995 and before June 1, 20142 | Part 1 of TSD D2SA001 | Part 2 of TSD D2SA001 | On or after June 1, 2014
note
113Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard or provision set out in column 2 and provided to the Minister in respect of a room air conditioner described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Room air conditioners manufactured before June 1, 2014 | CSA C368.1, for information set out in paragraphs (b) to (d) | (a)type;(b)power input;(c)cooling capacity, in kW (Btu/h); and(d)energy efficiency ratio.2 | Room air conditioners manufactured on or after June 1, 2014 | Part 1 of TSD D2SA001, for information set out in paragraphs (b) and (c) | (a)type;(b)cooling capacity, in kW (Btu/h); and(c)the product’s CEER.note
114Form of labelling#
A room air conditioner must be labelled
(a)if it was manufactured before June 1, 2014, in the form set out in Schedule 2; or
(b)if it is manufactured on or after June 1, 2014, in the form set out in Schedule 3.
115Manner of labelling#
The label must be displayed on the principal display panel of the product’s package
(a)by printing it on that panel; or
(b)by affixing to the panel an adhesive tag that is printed on paper that meets the requirements of subsection 14(1) and that has an adhesion capacity that is sufficient to prevent the tag from being dislodged from the packaging under normal handling conditions.
note
Subdivision B — Large Air Conditioners
116Definitions#
The following definitions apply in this Subdivision.
AHRI 340/360 means the AHRI standard ANSI/AHRI 340/360-2007 entitled Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment. (AHRI 340/360)
CSA C746-17 means the CSA standard CAN/CSA-C746-17 entitled Energy performance rating for large and single packaged vertical air conditioners and heat pumps. (CSA C746-17)
IEER means the integrated energy efficiency ratio, expressed in British thermal units per watt hour, that constitutes a single number cooling part-load efficiency metric of a large air conditioner. (IEER)
large air conditioner means a commercial or industrial unitary air conditioner with a cooling capacity of at least 19 kW (65,000 Btu/h) but less than 223 kW (760,000 Btu/h). It does not include a single package vertical air conditioner. (climatiseur de grande puissance)
10 C.F.R. Appendix A means Appendix A to Subpart F, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Air-Cooled Small (≥65,000 Btu/h), Large, and Very Large Commercial Package Air Conditioning and Heating Equipment, as amended from time to time. (appendice A 10 C.F.R.)
note
117Energy-using product#
(1)A large air conditioner is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 118, a large air conditioner is not considered to be an energy-using product unless
(a)in the case of a large air conditioner with a cooling capacity of less than 70 kW, it is manufactured on or after December 31, 1998; and
(b)in the case of a large air conditioner with a cooling capacity of 70 kW or more, it is manufactured on or after January 1, 2010.
118Energy efficiency standards — cooled by air#
(3)A large air conditioner complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a large air conditioner as defined in section 116. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 10.3 | On or after December 31, 1998 and before January 1, 20102 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.2IEER ≥ 11.4 | On or after January 1, 2010 and before January 1, 20183 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.2IEER ≥ 12.9 | On or after January 1, 2018 and before January 1, 20264 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 11.2IEER ≥ 14.8 | On or after January 1, 20265 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 9.7 | On or after December 31, 1998 and before January 1, 20106 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0IEER ≥ 11.2 | On or after January 1, 2010 and before January 1, 20187 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.0IEER ≥ 12.4 | On or after January 1, 2018 and before January 1, 20268 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 11.0IEER ≥ 14.2 | On or after January 1, 20269 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.0IEER ≥ 10.1 | On or after January 1, 2010 and before January 1, 201810 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 10.0IEER ≥ 11.6 | On or after January 1, 2018 and before January 1, 202611 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.0IEER ≥ 13.2 | On or after January 1, 202612 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 10.1 | On or after December 31, 1998 and before January 1, 201013 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0IEER ≥ 11.2 | On or after January 1, 2010 and before January 1, 201814 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.0IEER ≥ 12.7 | On or after January 1, 2018 and before January 1, 202615 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 11.0IEER ≥ 14.6 | On or after January 1, 202616 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 9.5 | On or after December 31, 1998 and before January 1, 201017 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8IEER ≥ 11.0 | On or after January 1, 2010 and before January 1, 201818 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 10.8IEER ≥ 12.2 | On or after January 1, 2018 and before January 1, 202619 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.8IEER ≥ 14.0 | On or after January 1, 202620 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 9.8IEER ≥ 9.9 | On or after January 1, 2010 and before January 1, 201821 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 9.8IEER ≥ 11.4 | On or after January 1, 2018 and before January 1, 202622 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 9.8IEER ≥ 13.0 | On or after January 1, 2026 | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 11.5 | On or after December 31, 1998 and before January 1, 20102 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.5IEER ≥ 11.7 | On or after January 1, 2010 and before January 1, 20183 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.1IEER ≥ 11.7 | On or after January 1, 20184 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 11.0 | On or after December 31, 1998 and before January 1, 20105 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0IEER ≥ 11.2 | On or after January 1, 2010 and before January 1, 20186 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.5IEER ≥ 11.2 | On or after January 1, 20187 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 11.3 | On or after December 31, 1998 and before January 1, 20108 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.3IEER ≥ 11.5 | On or after January 1, 2010 and before January 1, 20189 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.9IEER ≥ 11.5 | On or after January 1, 201810 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 10.8 | On or after December 31, 1998 and before January 1, 201011 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8IEER ≥ 11.0 | On or after January 1, 2010 and before January 1, 201812 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.3IEER ≥ 11.0 | On or after January 1, 201813 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0IEER ≥ 11.1 | On or after January 1, 2010 and before January 1, 201814 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.4IEER ≥ 11.1 | On or after January 1, 201815 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8IEER ≥ 10.9 | On or after January 1, 2010 and before January 1, 201816 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.2IEER ≥ 10.9 | On or after January 1, 2018 | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 11.5 | On or after December 31, 1998 and before January 1, 20102 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.5IEER ≥ 11.7 | On or after January 1, 2010 and before January 1, 20183 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.1IEER ≥ 11.7 | On or after January 1, 20184 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 11.0 | On or after December 31, 1998 and before January 1, 20105 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0IEER ≥ 11.2 | On or after January 1, 2010 and before January 1, 20186 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 12.0IEER ≥ 11.2 | On or after January 1, 20187 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 11.3 | On or after December 31, 1998 and before January 1, 20108 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.3IEER ≥ 11.5 | On or after January 1, 2010 and before January 1, 20189 | Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.9IEER ≥ 11.5 | On or after January 1, 201810 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-98 | Energy efficiency ratio ≥ 10.8 | On or after December 31, 1998 and before January 1, 201011 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8IEER ≥ 11.0 | On or after January 1, 2010 and before January 1, 201812 | Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.8IEER ≥ 11.0 | On or after January 1, 201813 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0IEER ≥ 11.1 | On or after January 1, 2010 and before January 1, 201814 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.9IEER ≥ 11.1 | On or after January 1, 201815 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-06 for energy efficiency ratioAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8IEER ≥ 10.9 | On or after January 1, 2010 and before January 1, 201816 | Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section | CSA C746-17 | Energy efficiency ratio ≥ 11.7IEER ≥ 10.9 | On or after January 1, 2018
note
119Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a large air conditioner described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Large air conditioners manufactured on or after December 31, 1998 and before January 1, 2010 | CSA C746-98 | (a)product classification set out in Column II of Table 1 of CSA C746-98;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio; and(d)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric.2 | Large air conditioners manufactured on or after January 1, 2010 and before January 1, 2018 | CSA C746-06AHRI 340/360 for IEER | (a)product classification set out in Column II of Table 1 of CSA C746-06;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)IEER; and(e)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric.3 | Large air conditioners manufactured on or after January 1, 2018 and before January 1, 2026 | CSA C746-17 | (a)product classification set out in Column II of Table 1 of CSA C746-17;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)IEER; and(e)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric.4 | Large air conditioners manufactured on or after January 1, 2026 | CSA C746-17 or 10 C.F.R. Appendix A | (a)product classification set out in Column II of Table 1 of CSA C746-17;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)IEER; and(e)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric.note
Subdivision C — Packaged Terminal Air Conditioners
120Definitions#
The following definitions apply in this Subdivision.
CSA C744-04 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2004/CAN/CSA-C744-04 entitled Standard for Packaged Terminal Air Conditioners and Heat Pumps. (CSA C744-04)
CSA C744-14 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2014/CAN/CSA-C744-14 entitled Standard for Packaged Terminal Air Conditioners and Heat Pumps. (CSA C744-14)
CSA C744-17 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2017/CAN/CSA-C744-17 entitled Packaged terminal air-conditioners and heat pumps. (CSA C744-17 )
packaged terminal air conditioner means a factory-built packaged terminal air conditioner that
note
121Energy-using product#
(1)A packaged terminal air conditioner is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 122, a packaged terminal air conditioner is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.
122Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to packaged terminal air conditioners that are manufactured during the periods set out in column 3.
(2)A packaged terminal air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a packaged terminal air conditioner as defined in section 120. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C744-04 | CSA C744-04, Table 2 | On or after December 31, 1998 and before September 30, 20122 | CSA C744-14 | CSA C744-14, Table 2 | On or after September 30, 2012 and before January 1, 20173 | CSA C744-17 | CSA C744-17, Table 2 | On or after January 1, 2017
note
123Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a packaged terminal air conditioner:
(a)its cooling capacity, expressed in kilowatts (British thermal units per hour);
(b)its energy efficiency ratio; and
(c)if applicable, identification of the product as a replacement unit.
(2)The information must be collected in accordance with
(a)CSA C744-04, if the product was manufactured on or after December 31, 1998 and before September 30, 2012;
(b)CSA C744-14, if the product was manufactured on or after September 30, 2012 and before January 1, 2017; or
(c)CSA C744-17, if the product is manufactured on or after January 1, 2017.
Subdivision D — Single Package Central Air Conditioners
124Definitions#
The following definitions apply in this Subdivision.
off mode power consumption means the power consumption when the unit is connected to mains power but is not providing cooling or heating. (consommation d’énergie en mode arrêt)
single package central air conditioner means a single-phase or three-phase central air conditioner that is a single package unit and that has a cooling capacity of less than 19 kW (65,000 Btu/h). It does not include a single package vertical air conditioner. (climatiseur central monobloc)
through-the-wall means, in respect of a single package central air conditioner, one that has a cooling capacity less than or equal to 8.79 kW (30,000 Btu/h), is designed to be installed through an exterior wall and is manufactured prior to January 1, 2023. (mural)
note
125Energy-using product#
(1)A single package central air conditioner is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 126, a single package central air conditioner is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
126Energy efficiency standards — single-phase#
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase single package central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
(1.1)The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase single package central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
(2)A single package central air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a single package central air conditioner as defined in section 124. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Single package central air conditioners, other than those that are through-the-wall or small-duct and high-velocity | CSA C656-14 for seasonal energy efficiency ratio10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 14.0Off mode power consumption ≤ 30 W | On or after February 3, 1995 and before January 1, 20232 | Single package central air conditioners that are through-the-wall | CSA C656-05 for seasonal energy efficiency ratio10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 12.0Off mode power consumption ≤ 30 W | On or after February 3, 1995 and before January 1, 20233 | Single package central air conditioners that are small-duct and high-velocity | CSA C656-14 for seasonal energy efficiency ratio10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 12.0Off mode power consumption ≤ 30 W | On or after February 3, 1995 and before January 1, 20234 | Single package central air conditioners, other than those that are space-constrained | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 13.4Off mode power consumption ≤ 30 W | On or after January 1, 20235 | Single package central air conditioners that are space-constrained | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 11.7Off mode power consumption ≤ 30 W | On or after January 1, 2023 | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Single package central air conditioners, other than those that are through-the-wall, or small-duct and high-velocity | CSA C656-14 | Seasonal energy efficiency ratio ≥ 14.0 | On or after February 3, 1995 and before January 1, 20232 | Single package central air conditioners, other than those that are space-constrained | CSA C656-14 | Seasonal energy efficiency ratio ≥ 14.0 | On or after January 1, 2023 and before January 1, 20263 | Single package central air conditioners, other than those that are space-constrained | 10 C.F.R. Appendix F1 | Seasonal energy efficiency ratio 2 ≥ 13.4 | On or after January 1, 20264 | Single package central air conditioners that are through-the-wall | CSA C656-05 | Seasonal energy efficiency ratio ≥ 12.0 | On or after February 3, 1995 and before January 1, 20235 | Single package central air conditioners that are space-constrained | CSA C656-14 | Seasonal energy efficiency ratio ≥ 12.0 | On or after January 1, 2023 and before January 1, 20266 | Single package central air conditioners that are space-constrained | 10 C.F.R. Appendix F1 | Seasonal energy efficiency ratio 2 ≥ 13.9 | On or after January 1, 20267 | Single package central air conditioners that are small-duct and high-velocity | CSA C656-14 | Seasonal energy efficiency ratio ≥ 12.0 | On or after January 1, 2017 and before January 1, 2023
note
127Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected and provided to the Minister in respect of a single package central air conditioner described in column 1 and, if applicable, the information must be collected in accordance with the standard set out in column 2. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Single package central air conditioners that are single-phase, other than those that are through-the-wall, manufactured on or after February 3, 1995 and before January 1, 2023 | CSA C656-14 for information set out in paragraphs (a) to (c)10 C.F.R. Appendix M for off mode power consumption | (a)product classification set out in column II of Table 1 to CSA C656-14;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio;(d)off mode power consumption, in watts; and(e)phase of electric current.2 | Single package central air conditioners that are three-phase, other than those that are through-the-wall, manufactured on or after February 3, 1995 and before January 1, 2023 | CSA C656-14 for information set out in paragraphs (a) to (c) | (a)product classification set out in column II of Table 1 to CSA C656-14;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio; and(d)phase of electric current.3 | Single package central air conditioners that are single-phase, through-the-wall and manufactured on or after February 3, 1995 and before January 1, 2023 | CSA C656-05 for information set out in paragraphs (a) to (c)10 C.F.R. Appendix M for off mode power consumption | (a)product classification set out in column II of Table 1 to CSA C656-05;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio;(d)off mode power consumption, in watts; and(e)phase of electric current.4 | Single package central air conditioners that are three-phase, through-the-wall and manufactured on or after February 3, 1995 and before January 1, 2023 | CSA C656-05 for information set out in paragraphs (a) to (c) | (a)product classification set out in column II of Table 1 to CSA C656-05;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio; and(d)phase of electric current.5 | Single package central air conditioners that are three-phase and manufactured on or after January 1, 2023 and before January 1, 2026 | CSA C656-14 for information set out in paragraphs (a) to (c) | (a)product classification set out in column II of Table 1 to CSA C656-14;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio; and(d)phase of electric current.5.1 | Single package central air conditioners that are three-phase and manufactured on or after January 1, 2026 | 10 C.F.R. Appendix F1 for information set out in paragraphs (b) and (c) | (a)type;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio 2; and(d)phase of electric current.6 | Single package central air conditioners that are single-phase and manufactured on or after January 1, 2023 | 10 C.F.R. Appendix M1 for information set out in paragraphs (b) to (d) | (a)type;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio 2;(d)off mode power consumption, in watts; and(e)phase of electric current.note
127.1Early compliance#
A single package central air conditioner that is manufactured on or after January 1, 2025 and before January 1, 2026 is deemed to satisfy the requirements of sections 126 and 127 if it satisfies the requirements of those sections that would have applied to the single package central air conditioner if it had been manufactured on or after January 1, 2026.note
Subdivision E — Single Package Vertical Air Conditioners
128Definition of single package vertical air conditioner#
In this Subdivision, single package vertical air conditioner means a single package commercial air conditioner, with or without heating capability, that has its major components arranged vertically, is air-cooled and encased and is intended for mounting through, or on either side of, an exterior wall. It does not include a single package commercial air conditioner that has reverse cycle refrigeration.
129Energy-using product#
(1)A single package vertical air conditioner is prescribed as an energy-using product.
note
130Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to single package vertical air conditioners described in column 1 that are manufactured during the periods set out in column 3.
(2)A single package vertical air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C746-17 that are applicable to a single package vertical air conditioner as defined in section 128.Item | Column 1 | Column 2 | Column 3Energy-using Product | Energy Efficiency Standard | Period of Manufacture1 | Single package vertical air conditioners that have a cooling capacity of < 19 kW (65,000 Btu/h) | Energy efficiency ratio ≥ 9.0 | On or after January 1, 2011 and before September 23, 20192 | Single package vertical air conditioners that have a cooling capacity of < 19 kW (65,000 Btu/h) | Energy efficiency ratio ≥ 11.0 | On or after September 23, 20193 | Single package vertical air conditioners that have a cooling capacity of ≥ 19 kW (65,000 Btu/h) and < 39.5 kW (135,000 Btu/h) | Energy efficiency ratio ≥ 8.9 | On or after January 1, 2011 and before October 9, 20154 | Single package vertical air conditioners that have a cooling capacity of ≥ 19 kW (65,000 Btu/h) and < 39.5 kW (135,000 Btu/h) | Energy efficiency ratio ≥ 10.0 | On or after October 9, 20155 | Single package vertical air conditioners that have a cooling capacity of ≥ 39.5 kW (135,000 Btu/h) and < 70 kW (240,000 Btu/h) | Energy efficiency ratio ≥ 8.6 | On or after January 1, 2011 and before October 9, 20166 | Single package vertical air conditioners that have a cooling capacity of ≥ 39.5 kW (135,000 Btu/h) and < 70 kW (240,000 Btu/h) | Energy efficiency ratio ≥ 10.0 | On or after October 9, 2016
note
131Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C746-17 and provided to the Minister in respect of a single package vertical air conditioner:
(a)its classification as set out in column II of Table 1 to CSA C746-17;
(b)its cooling capacity, expressed in kilowatts (British thermal units per hour); and
(c)its energy efficiency ratio.
note
Subdivision F — Split System Central Air Conditioners
132Definitions#
The following definitions apply in this Subdivision.
off mode power consumption means the power consumption when the unit is connected to mains power but is not providing cooling or heating. (consommation d’énergie en mode arrêt)
split system central air conditioner means a single-phase or three-phase central air conditioner that is a split system and that has a cooling capacity of less than 19 kW (65,000 Btu/h). (climatiseur central bibloc)
split-system central air conditioner [Repealed, SOR/2022-265, s. 9]
note
133Energy-using product#
(1)A split system central air conditioner is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 134, a split system central air conditioner is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
note
134Energy efficiency standards — single-phase#
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase split system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
(1.1)The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase split system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
(2)A split system central air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split system central air conditioner as defined in section 132. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Split system central air conditioners, other than those that are small-duct and high-velocity | CSA C656-14 for seasonal energy efficiency ratio10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 13.0Off mode power consumption ≤ 30 W | On or after February 3, 1995 and before January 1, 20232 | Split system central air conditioners that are small-duct and high-velocity | CSA C656-14 for seasonal energy efficiency ratio10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 12.0Off mode power consumption ≤ 30 W | On or after February 3, 1995 and before January 1, 20233 | Split system central air conditioners, other than those that are space-constrained or small-duct and high-velocity | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 13.4Off mode power consumption ≤ 30 W | On or after January 1, 20234 | Split system central air conditioners that are small-duct and high-velocity | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 12.0Off mode power consumption ≤ 30 W | On or after January 1, 20235 | Split system central air conditioners that are space-constrained | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 11.7Off mode power consumption ≤ 30 W | On or after January 1, 2023 | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Split system central air conditioners, other than those that are small-duct and high-velocity | CSA C656-14 | Seasonal energy efficiency ratio ≥ 13.0 | On or after February 3, 1995 and before January 1, 20262 | Split system central air conditioners, other than those that are space-constrained or small-duct and high-velocity | 10 C.F.R. Appendix F1 | Seasonal energy efficiency ratio 2 ≥ 13.4 | On or after January 1, 20263 | Split system central air conditioners that are small-duct and high-velocity | CSA C656-14 | Seasonal energy efficiency ratio ≥ 12.0 | On or after February 3, 1995 and before January 1, 20264 | Split system central air conditioners that are small-duct and high-velocity | 10 C.F.R. Appendix F1 | Seasonal energy efficiency ratio 2 ≥ 13.0 | On or after January 1, 20265 | Split system central air conditioners that are space-constrained | 10 C.F.R. Appendix F1 | Seasonal energy efficiency ratio 2 ≥ 12.7 | On or after January 1, 2026
note
135Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected and provided to the Minister in respect of a split system central air conditioner described in column 1 and, if applicable, the information must be collected in accordance with the standard set out in column 2. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Split system central air conditioners that are single-phase and manufactured on or after February 3, 1995 and before January 1, 2023 | CSA C656-14 for information set out in paragraphs (a) to (c)10 C.F.R. Appendix M for off mode power consumption | (a)product classification set out in column II of Table 1 to CSA C656-14;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio;(d)off mode power consumption, in watts; and(e)phase of electric current.2 | Split system central air conditioners that are three-phase and manufactured on or after February 3, 1995 and before January 1, 2026 | CSA C656-14 for information set out in paragraphs (a) to (c) | (a)product classification set out in column II of Table 1 to CSA C656-14;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio; and(d)phase of electric current.2.1 | Split system central air conditioners that are three-phase and manufactured on or after January 1, 2026 | 10 C.F.R. Appendix F1 for information set out in paragraphs (b) and (c) | (a)type;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio 2; and(d)phase of electric current.3 | Split system central air conditioners that are single-phase and manufactured on or after January 1, 2023 | 10 C.F.R. Appendix M1 for information set out in paragraphs (b) to (d) | (a)type;(b)cooling capacity in kW (Btu/h);(c)seasonal energy efficiency ratio 2;(d)off mode power consumption, in watts; and(e)phase of electric current.note
135.1Early compliance#
A split system central air conditioner that is manufactured on or after January 1, 2025 and before January 1, 2026 is deemed to satisfy the requirements of sections 134 and 135 if it satisfies the requirements of those sections that would have applied to the split system central air conditioner if it had been manufactured on or after January 1, 2026.note
Subdivision G — Large Condensing Units
136Definition of large condensing unit#
In this Subdivision, large condensing unit means a commercial or industrial condensing unit that is intended for air conditioning applications and that has a cooling capacity of at least 40 kW (135,000 Btu/h) but not more than 70 kW (240,000 Btu/h).note
137Energy-using product#
(1)A large condensing unit is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 138, a large condensing unit is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.
138Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to large condensing units described in column 1.
(2)A large condensing unit complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C746-98 that are applicable to a large condensing unit as defined in section 136. | Column 1 | Column 2Item | Energy-using Product | Energy Efficiency Standard1 | Large condensing units that are cooled by air | Energy efficiency ratio ≥ 10.12 | Large condensing units that are cooled by water or evaporation | Energy efficiency ratio ≥ 13.1
139Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C746-98 and provided to the Minister in respect of a large condensing unit:
(a)its classification as set out in Column II of Table 1 of CSA C746-98;
(b)its cooling capacity, expressed in kilowatts (British thermal units per hour); and
(c)its energy efficiency ratio.
Subdivision H — Chillers
140Definitions#
The following definitions apply in this Subdivision.
ASHRAE 90.1-16 means ANSI/ASHRAE/IES Standard 90.1-2016, entitled Energy Standard for Buildings Except Low-Rise Residential Buildings. (ASHRAE 90.1-16)
CSA C743-02 means the CSA standard CAN/CSA-C743-02 entitled Performance Standard for Rating Packaged Water Chillers. (CSA C743-02)
CSA C743-09 means the CSA standard CAN/CSA-C743-09 entitled Performance Standard for Rating Packaged Water Chillers. (CSA C743-09)
note
142Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to chillers that are manufactured during the periods set out in column 3.
(2)A chiller complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a chiller as defined in section 140. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C743-02 | CSA C743-02, Tables 9 to 15 | On or after October 28, 2004 and before January 1, 20172 | CSA C743-09 | Product’s coefficient of performance and integrated part-load value must meet those applicable to the product in CSA C743-09, Path A or Path B, Table 10 | On or after January 1, 2017 and before December 31, 20193 | ASHRAE 90.1-16, table 6.8.1-3, column 6 | Product’s coefficient of performance and integrated part-load value must meet those applicable to the product in ASHRAE 90.1-16, Path A or Path B, Table 6.8.1-3 | On or after December 31, 2019
note
143Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a chiller described in column 1.Item | Column 1 | Column 2 | Column 3Energy-using Product | Testing Standard | Information1 | Chillers manufactured on or after October 28, 2004 and before January 1, 2017 | CSA C743-02 | (a)type;(b)net cooling/heating capacity in kW (tons);(c)coefficient of performance; and(d)integrated part-load value or non-standard part-load value and a list of non-standard conditions.2 | Chillers manufactured on or after January 1, 2017 and before December 31, 2019 | CSA C743-09 | (a)type;(b)net cooling/heating capacity, in kW (tons);(c)coefficient of performance;(d)compliance path for the energy-efficiency standard, namely, Path A or Path B of Table 10 to CSA C743-09; and(e)integrated part-load value or non-standard part-load value and a list of non-standard conditions.3 | Chillers manufactured on or after December 31, 2019 | ASHRAE 90.1-16, Table 6.8.1-3, column 6 | (a)type;(b)net cooling/heating capacity in kW (tons);(c)coefficient of performance;(d)compliance path for the energy-efficiency standard, namely, Path A or Path B of Table 6.8.1-3 of ASHRAE 90.1-16;(e)integrated part-load value; and(f)list of non-standard conditions for centrifugal chillers designed for non-standard operation.note
Subdivision I — Portable Air Conditioners
144Definitions#
The following definitions apply in this Subdivision.
10 C.F.R. Appendix CC means Appendix CC to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Portable Air Conditioners, as amended from time to time. (appendice CC 10 C.F.R.)
dual-duct portable air conditioner means a portable air conditioner that draws some or all of the condenser inlet air from outside the conditioned space through a duct attached to an adjustable window bracket and discharges the condenser outlet air outside the conditioned space by means of a separate duct attached to an adjustable window bracket. (climatiseur portative à deux conduits)
portable air conditioner means a single package air conditioner, other than a packaged terminal air conditioner, room air conditioner or dehumidifier, with or without mounted wheels, that is portable and that
(a)is designed to deliver cooled and conditioned air to an enclosed space;
(b)is powered by single-phase electric current; and
(c)has a SACC of less than 19 kW (65,000 Btu/h). (climatiseur portatif)
SACC means the seasonally adjusted cooling capacity of the product, expressed in kilowatts (British thermal units per hour), that constitutes the amount of cooling provided to the conditioned space. (SACC)
single-duct portable air conditioner means a portable air conditioner that draws all of the condenser inlet air from the conditioned space without the means of a duct and discharges the condenser outlet air outside the conditioned space through a single duct attached to an adjustable window bracket. (climatiseur portatif à un conduit unique)
note
145Energy-using product#
(1)A portable air conditioner is prescribed as an energy-using product.
(2)However, a portable air conditioner is not considered to be an energy-using product
(b)for the purposes of sections 145.1, 147 and 148, unless it is manufactured on or after January 10, 2025.
note
145.1Energy efficiency standard#
(1)The energy efficiency standard applicable to a portable air conditioner is that it must have a CEER equal to or greater than the result determined by the formula
(2)A portable air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with the applicable testing procedures established by 10 C.F.R. Appendix CC.
note
146Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix CC and provided to the Minister in respect of a portable air conditioner:
(a)its SACC;
(c)whether it is a single-duct portable air conditioner or a dual-duct portable air conditioner.
(2)For a product with multiple duct configuration options, the information required by paragraphs 1(a) and (b) must be provided for both applicable duct configurations.
note
147Form of labelling#
A portable air conditioner manufactured on or after January 10, 2025 must be labelled in the form set out in Schedule 4.note
148Manner of labelling#
The label must be displayed on the principal display panel of the product’s package, either
(a)by printing it on that panel; or
(b)by affixing to the panel an adhesive tag that is printed on paper that meets the requirements of subsection 14(1) and that has an adhesion capacity that is sufficient to prevent the tag from being dislodged from the packaging under normal handling conditions.
note
Division 3 — Heat Pumps
Interpretation
186Definitions#
The following definitions apply in this Division.
CSA C656-05 means the CSA standard CAN/CSA-C656-05 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-05)
CSA C656-14 means the CSA standard CAN/CSA-C656-14 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-14)
CSA C746-06 means the CSA standard CAN/CSA-C746-06 entitled Performance Standard for Rating Large and Single Packaged Vertical Air Conditioners and Heat Pumps. (CSA C746-06)
CSA C13256-1 means the CSA standard CAN/CSA-C13256-1-01 entitled Water-Source Heat Pumps — Testing and Rating for Performance — Part 1: Water-to-Air and Brine-to-Air Heat Pumps. (CSA C13256-1)
small-duct and high-velocity means, with respect to a split system central heat pump or a single package central heat pump, one that has an indoor blower and coil combination that
(a)produces at least 300 Pa (1.2 inches of water) external static pressure when operated at an air volume rate of 104 to 165 L/s (220 to 350 cubic feet/minute) per nominal ton of cooling; and
(b)uses room outlets that produce velocities greater than 5 m/s (1,000 feet/minute) and that each have an area less than 39 cm2 (6 square inches). (à grand débit et à petits conduits)
space-constrained, with respect to a single package central heat pump or a split system central heat pump, means one that
(a)has a cooling capacity that is less than or equal to 8.79 kW (30,000 Btu/h); and
(b)has an outdoor or indoor unit
(i)that has an overall displacement that is — or two or more overall exterior dimensions that are — substantially smaller than those of other units of a similar cooling capacity that are usually installed in single-family homes, and
(ii)with respect to which an increase in the overall displacement or two or more overall exterior dimensions would result in a considerable increase in the usual cost of installation or in a significant loss in the utility of the product to the consumer. (à espace restreint)
10 C.F.R. Appendix F1 means Appendix F1 to Subpart F, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Air-Cooled, Three-Phase, Small Commercial Package Air Conditioning and Heating Equipment With a Cooling Capacity of Less Than 65,000 Btu/h and Air-Cooled, Three-Phase, Variable Refrigerant Flow Multi-Split Air Conditioners and Heat Pumps With a Cooling Capacity of Less Than 65,000 Btu/h, as amended from time to time. (appendice F1 10 C.F.R.)
10 C.F.R. Appendix M means Appendix M to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M 10 C.F.R.)
10 C.F.R. Appendix M1 means Appendix M1 to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M1 10 C.F.R.)
note
186.1Type#
For the purposes of these Regulations, a central heat pump manufactured on or after January 1, 2023 is one of the following types:
(a)single package, other than space-constrained;
(b)space-constrained single package;
(c)split system, other than space-constrained or small-duct and high-velocity;
(d)small-duct and high-velocity split-system; or
(e)space-constrained split-system.
note
Subdivision A — Ground-Source Heat Pumps
187Definitions#
The following definitions apply in this Subdivision.
CSA C446-94 means the CSA standard CAN/CSA-C446-94 entitled Performance of Ground-Source Heat Pumps. (CSA C446-94)
188Energy-using product#
(1)A ground-source heat pump is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 189, a ground-source heat pump is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
189Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to ground-source heat pumps that are manufactured during the periods set out in column 3.
(2)A ground source heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a ground source heat pump as defined in section 187. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C446-94 | CSA C446-94, Table 2 | On or after February 3, 1995 and before June 1, 20062 | CSA C13256-1 | CSA C13256-1, Table 10A, first row, for the open-loop systemCSA C13256-1, Table 10A, second row, for the closed-loop system | On or after June 1, 2006
note
190Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a ground-source heat pump:
(a)its AHRI type classification;
(b)its cooling capacity, expressed in kilowatts (British thermal units per hour);
(c)its cooling coefficient of performance;
(d)its heating capacity, expressed in kilowatts (British thermal units per hour);
(e)its heating coefficient of performance; and
(2)The information must be collected in accordance with
(a)CSA C446-94, if the product was manufactured on or after February 3, 1995 and before June 1, 2006; or
(b)CSA C13256-1, if the product is manufactured on or after June 1, 2006.
Subdivision B — Internal Water Loop Heat Pumps
191Definition of internal water loop heat pump#
In this Subdivision, internal water loop heat pump means a water-source single package or split-system heat pump that is factory-built, is intended for installation in an internal water loop system and has a cooling or heating capacity of not more than 40 kW (135,000 Btu/h).note
192Energy-using product#
(1)An internal water loop heat pump is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 193, an internal water loop heat pump is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
193Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to internal water loop heat pumps described in column 1.
(2)An internal water loop heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C13256-1 that are applicable to an internal water loop heat pump as defined in section 191. | Column 1 | Column 2Item | Energy-using Product | Energy Efficiency Standard1 | Internal water loop heat pumps that have a cooling capacity of < 5 kW | Cooling coefficient of performance ≥ 3.28 with 30°C inlet waterHeating coefficient of performance ≥ 4.2 with 20°C inlet water2 | Internal water loop heat pumps that have a cooling capacity of ≥ 5 kW but ≤ 40 kW | Cooling coefficient of performance ≥ 3.52 with 30°C inlet waterHeating coefficient of performance ≥ 4.2 with 20°C inlet water
194Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C13256-1 and provided to the Minister in respect of an internal water loop heat pump:
(a)its AHRI type classification;
(b)its voltage;
(c)its cooling capacity, expressed in kilowatts (British thermal units per hour);
(d)its cooling coefficient of performance with 30°C inlet water;
(e)its heating capacity, expressed in kilowatts (British thermal units per hour); and
(f)its heating coefficient of performance with 20°C inlet water.
Subdivision C — Large Heat Pumps
195Definitions#
The following definitions apply in this Subdivision.
AHRI 340/360 means the AHRI standard ANSI/AHRI 340/360-2007 entitled Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment. (AHRI 340/360)
CSA C746-17 means the CSA standard CAN/CSA-C746-17 entitled Energy performance rating for large and single packaged vertical air conditioners and heat pumps. (CSA C746-17)
CSA C746-98 means the CSA standard CAN/CSA-C746-98 entitled Performance Standard for Rating Large Air Conditioners and Heat Pumps. (CSA C746-98)
IEER means the integrated energy efficiency ratio, expressed in British thermal units per watt hour, that constitutes a single number cooling part-load efficiency metric of a large heat pump. (IEER)
large heat pump means a commercial or industrial unitary heat pump that is intended for air-conditioning and space-heating applications and that has a cooling capacity of at least 19 kW (65,000 Btu/h) but less than 223 kW (760,000 Btu/h). It does not include a single package vertical heat pump. (thermopompe de grande puissance)
10 C.F.R. Appendix A means Appendix A to Subpart F, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Air-Cooled Small (≥65,000 Btu/h), Large, and Very Large Commercial Package Air Conditioning and Heating Equipment, as amended from time to time. (appendice A 10 C.F.R.)
note
196Energy-using product#
(1)A large heat pump is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 197, a large heat pump is not considered to be an energy-using product unless
(a)in the case of a large heat pump with a cooling capacity that is less than 70 kW, it is manufactured on or after December 31, 1998; and
(b)in the case of a large heat pump with a cooling capacity that is greater than or equal to 70 kW, it is manufactured on or after January 1, 2010.
197Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to large heat pumps described in column 1 that are manufactured during the periods set out in column 4 and that have no heating section or have an electric heating section.
(2)The energy efficiency standards set out in column 3 of Table 2 to this section apply to large heat pumps described in column 1 that are manufactured during the periods set out in column 4 and that have a heating section other than an electric heating section.
(3)A large heat pump complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a large heat pump as defined in section 195. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-98 | Energy efficiency ratio ≥ 10.1Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.2 with –8.3°C inlet air | On or after December 31, 1998 and before January 1, 20102 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 11.2 | On or after January 1, 2010 and before January 1, 20183 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-17 | Energy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 12.2 | On or after January 1, 2018 and before January 1, 20264 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.4 with 8.3°C inlet air and ≥ 2.25 with −8.3°C inlet airIEER ≥ 14.1 | On or after January 1, 20265 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-98 | Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.1 with 8.3°C inlet air and ≥ 2.0 with −8.3°C inlet air | On or after December 31, 1998 and before January 1, 20106 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.6Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.7 | On or after January 1, 2010 and before January 1, 20187 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-17 | Energy efficiency ratio ≥ 10.6Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 11.6 | On or after January 1, 2018 and before January 1, 20268 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.6Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 13.5 | On or after January 1, 20269 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 9.5Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 9.6 | On or after January 1, 2010 and before January 1, 201810 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-17 | Energy efficiency ratio ≥ 9.5Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.6 | On or after January 1, 2018 and before January 1, 202611 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 9.5Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 12.5 | On or after January 1, 2026 | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-98 | Energy efficiency ratio ≥ 9.9Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.2 with –8.3°C inlet air | On or after December 31, 1998 and before January 1, 20102 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 11.0 | On or after January 1, 2010 and before January 1, 20183 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-17 | Energy efficiency ratio ≥ 10.8Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 12.0 | On or after January 1, 2018 and before January 1, 20264 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.8Heating coefficient of performance ≥ 3.4 with 8.3°C inlet air and ≥ 2.25 with −8.3°C inlet airIEER ≥ 13.9 | On or after January 1, 20265 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-98 | Energy efficiency ratio ≥ 9.1Heating coefficient of performance ≥ 3.1 with 8.3°C inlet air and ≥ 2.0 with −8.3°C inlet air | On or after December 31, 1998 and before January 1, 20106 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.4Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.5 | On or after January 1, 2010 and before January 1, 20187 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-17 | Energy efficiency ratio ≥ 10.4Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 11.4 | On or after January 1, 2018 and before January 1, 20268 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.4Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 13.3 | On or after January 1, 20269 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 9.4 | On or after January 1, 2010 and before January 1, 201810 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-17 | Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.4 | On or after January 1, 2018 and before January 1, 202611 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 12.3 | On or after January 1, 2026
note
198Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a large heat pump described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Large heat pumps manufactured on or after December 31, 1998 and before January 1, 2010 | CSA C746-98 | (a)product classification set out in columns II and III of Table 2 of CSA C746-98;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)heating capacity, in kW (Btu/h);(e)heating coefficient of performance at 8.3°C;(f)heating coefficient of performance at –8.3°C; and(g)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric.2 | Large heat pumps manufactured on or after January 1, 2010 and before January 1, 2018 | CSA C746-06AHRI 340/360 for IEER | (a)product classification set out in columns II and III of Table 2 of CSA C746-06;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)heating capacity, in kW (Btu/h);(e)heating coefficient of performance at 8.3°C;(f)heating coefficient of performance at –8.3°C;(g)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric; and(h)IEER.3 | Large heat pumps manufactured on or after January 1, 2018 and before January 1, 2026 | CSA C746-17 | (a)product classification set out in columns II and III of Table 2 of CSA C746-17;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)heating capacity, in kW (Btu/h);(e)heating coefficient of performance at 8.3°C;(f)heating coefficient of performance at –8.3°C;(g)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric; and(h)IEER.4 | Large heat pumps manufactured on or after January 1, 2026 | CSA C746-17 or 10 C.F.R. Appendix A | (a)product classification set out in columns II and III of Table 2 of CSA C746-17;(b)cooling capacity, in kW (Btu/h);(c)energy efficiency ratio;(d)heating capacity, in kW (Btu/h);(e)heating coefficient of performance at 8.3°C;(f)heating coefficient of performance at −8.3°C;(g)information that indicates whether the product has a heating section and, if so, whether it is electric or other than electric; and(h)IEER.note
Subdivision D — Packaged Terminal Heat Pumps
199Definitions#
The following definitions apply in this Subdivision.
CSA C744-04 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2004/CAN/CSA-C744-04 entitled Standard for Packaged Terminal Air Conditioners and Heat Pumps. (CSA C744-04)
CSA C744-17 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2017/CSA-C744-17 entitled Packaged terminal air conditioners and heat pumps. (CSA C744-17)
packaged terminal heat pump means a factory-built packaged heat pump that consists of a separate unencased refrigeration system and uses reverse cycle refrigeration as its primary heat source. (thermopompe terminale autonome)
note
200Energy-using product#
(1)A packaged terminal heat pump is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 201, a packaged terminal heat pump is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.
201Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to packaged terminal heat pumps that are manufactured during the periods set out in column 3.
(2)A packaged terminal heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a packaged terminal heat pump as defined in section 199. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C744-04 | CSA C744-04, Table 2 | On or after December 31, 1998 and before September 30, 20122 | CSA C744-17 | CSA C744-17, Table 2 | On or after September 30, 2012
note
202Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a packaged terminal heat pump:
(a)its cooling capacity, expressed in kilowatts (British thermal units per hour);
(b)its energy efficiency ratio;
(c)its heating capacity, expressed in kilowatts (British thermal units per hour);
(d)its heating coefficient of performance; and
(e)if applicable, identification of the product as a replacement unit.
(2)The information must be collected in accordance with
(a)CSA C744-04, if the product was manufactured on or after December 31, 1998 and before September 30, 2012; or
(b)CSA C744-17, if the product is manufactured on or after September 30, 2012.
note
Subdivision E — Single Package Central Heat Pumps
203Definitions#
The following definitions apply in this Subdivision.
off mode power consumption means the power consumption when the unit is connected to mains power but is not providing cooling or heating. (consommation d’énergie en mode arrêt)
single package central heat pump means a single-phase or three-phase air-to-air central heat pump that is a single package unit and that has a cooling capacity of less than 19 kW (65,000 Btu/h), but does not include a single package vertical heat pump. (thermopompe centrale monobloc)
single package heat pump [Repealed, SOR/2022-265, s. 15]
through-the-wall means, in respect of a single package central heat pump, one that has a cooling capacity less than or equal to 8.79 kW (30,000 Btu/h), that is designed to be installed through an exterior wall and that is manufactured prior to January 1, 2023. (murale)
note
204Energy-using product#
(1)A single package central heat pump is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 205, a single package central heat pump is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.
note
205Energy efficiency standards — single-phase#
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase single package central heat pumps described in column 1 that are manufactured during the periods set out in column 4.
(1.1)The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase single package central heat pumps described in column 1 that are manufactured during the periods set out in column 4.
(2)A single package central heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a single package central heat pump as defined in section 203. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Single package central heat pumps, other than those that are through-the-wall or small-duct and high-velocity | CSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 14.0Heating seasonal performance factor (Region V) ≥ 7.0Off mode power consumption ≤ 33 W | On or after February 3, 1995 and before January 1, 20232 | Single package central heat pumps that are through-the-wall | CSA C656-05 for seasonal energy efficiency ratio and heating seasonal performance factor10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.4Off mode power consumption ≤ 33 W | On or after February 3, 1995 and before January 1, 20233 | Single package central heat pumps that are small-duct and high-velocity | CSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.3Off mode power consumption ≤ 30 W | On or after February 3, 1995 and before January 1, 20234 | Single package central heat pumps, other than those that are space-constrained | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 13.4Heating seasonal performance factor 2 (Region V) ≥ 5.4Off mode power consumption ≤ 33 W | On or after January 1, 2023 and before January 1, 20255 | Single package central heat pumps that are space-constrained | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 11.9Heating seasonal performance factor 2 (Region V) ≥ 5.0Off mode power consumption ≤ 33 W | On or after January 1, 2023 and before January 1, 20256 | Single package central heat pumps, other than those that are space-constrained | 10 C.F.R. Appendix M1, except that the very low temperature heating test (H4) must be conducted | Seasonal energy efficiency ratio 2 ≥ 13.4Heating seasonal performance factor 2 (Region V) ≥ 5.4Off mode power consumption ≤ 33 W | On or after January 1, 20257 | Single package central heat pumps that are space-constrained | 10 C.F.R. Appendix M1, except that the very low temperature heating test (H4) must be conducted | Seasonal energy efficiency ratio 2 ≥ 11.9Heating seasonal performance factor 2 (Region V) ≥ 5.0Off mode power consumption ≤ 33 W | On or after January 1, 2025 | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Single package central heat pumps, other than those that are through-the-wall or small-duct and high-velocity | CSA C656-14 | Seasonal energy efficiency ratio ≥ 14.0Heating seasonal performance factor (Region V) ≥ 7.0 | On or after February 3, 1995 and before January 1, 20232 | Single package central heat pumps that are through-the-wall | CSA C656-05 | Seasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.4 | On or after February 3, 1995 and before January 1, 20233 | Single package central heat pumps that are small-duct and high-velocity | CSA C656-14 | Seasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.3 | On or after February 3, 1995 and before January 1, 20234 | Single package central heat pumps, other than those that are space-constrained | CSA C656-14 | Seasonal energy efficiency ratio ≥ 14.0Heating seasonal performance factor (Region V) ≥ 7.0 | On or after January 1, 2023 and before January 1, 20265 | Single package central heat pumps that are space-constrained | CSA C656-14 | Seasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.4 | On or after January 1, 2023 and before January 1, 20266 | Single package central heat pumps, other than those that are space-constrained | 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted | Seasonal energy efficiency ratio 2 ≥ 13.4Heating seasonal performance factor 2 (Region V) ≥ 5.3 | On or after January 1, 20267 | Single package central heat pumps that are space-constrained | 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted | Seasonal energy efficiency ratio 2 ≥ 13.9Heating seasonal performance factor 2 (Region V) ≥ 5.3 | On or after January 1, 2026
note
206Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected and provided to the Minister in respect of a single package central heat pump described in column 1 and, if applicable, the information must be collected in accordance with the standard set out in column 2. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Single package central heat pumps that are single-phase, other than those that are through-the-wall, manufactured on or after February 3, 1995 and before January 1, 2023 | CSA C656-14 for information set out in paragraphs (a) to (e)10 C.F.R. Appendix M for off mode power consumption | (a)product classification set out in column II of Table 1 to CSA C656-14;(b)cooling capacity in kW (Btu/h);(c)heating capacity in kW (Btu/h);(d)seasonal energy efficiency ratio;(e)heating seasonal performance factor and the region for the factor;(f)off mode power consumption, in watts; and(g)phase of electric current.2 | Single package central heat pumps that are three-phase, other than those that are through-the-wall, manufactured on or after February 3, 1995 and before January 1, 2023 | CSA C656-14 for information set out in paragraphs (a) to (e) | (a)product classification set out in column II of Table 1 to CSA C656-14;(b)cooling capacity in kW (Btu/h);(c)heating capacity in kW (Btu/h);(d)seasonal energy efficiency ratio;(e)heating seasonal performance factor and the region for the factor; and(f)phase of electric current.3 | Single package central heat pumps that are single-phase, through-the-wall and manufactured on or after February 3, 1995 and before January 1, 2023 | CSA C656-05 for information set out in paragraphs (a) to (e)10 C.F.R. Appendix M for off mode power consumption | (a)product classification set out in column II of Table 1 to CSA C656-05;(b)cooling capacity in kW (Btu/h);(c)heating capacity in kW (Btu/h);(d)seasonal energy efficiency ratio;(e)heating seasonal performance factor and the region for the factor;(f)off mode power consumption, in watts; and(g)phase of electric current.4 | Single package central heat pumps that are three-phase, through-the-wall and manufactured on or after February 3, 1995 and before January 1, 2023 | CSA C656-05 for information set out in paragraphs (a) to (e) | (a)product classification set out in column II of Table 1 to CSA C656-05;(b)cooling capacity in kW (Btu/h);(c)heating capacity in kW (Btu/h);(d)seasonal energy efficiency ratio;(e)heating seasonal performance factor and the region for the factor; and(f)phase of electric current.5 | Single package central heat pumps that are single-phase and manufactured on or after January 1, 2023 and before January 1, 2025 | 10 C.F.R. Appendix M1 for information set out in paragraphs (b) to (i) | (a)type;(b)cooling capacity in kW (Btu/h);(c)heating capacity at 8.3°C (47°F) in kW (Btu/h);(d)seasonal energy efficiency ratio 2;(e)information that indicates whether the results from the very low temperature heating test (H4) were included in the calculation of the heating seasonal performance factor 2 for Region V;(f)heating seasonal performance factor 2 for Region V;(g)heating capacity at -15°C (5°F) in kW (Btu/h), if the very low temperature heating test (H4) was conducted;(h)coefficient of performance at -15°C (5°F), if the very low temperature heating test (H4) was conducted;(i)off mode power consumption, in watts; and(j)phase of electric current.6 | Single package central heat pumps that are single-phase and manufactured on or after January 1, 2025 | 10 C.F.R. Appendix M1, except that the very low temperature heating test (H4) must be conducted for information set out in paragraphs (b) to (h) | (a)type;(b)cooling capacity in kW (Btu/h);(c)heating capacity at 8.3°C (47°F) in kW (Btu/h);(d)seasonal energy efficiency ratio 2;(e)heating seasonal performance factor 2 for Region V;(f)heating capacity at -15°C (5°F) in kW (Btu/h);(g)coefficient of performance at -15°C (5°F);(h)off mode power consumption, in watts; and(i)phase of electric current.7 | Single package central heat pumps that are three-phase and manufactured on or after January 1, 2023 and before January 1, 2026 | CSA C656-14 for information set out in paragraphs (a) to (e) | (a)product classification set out in column II of Table 1 to CSA C656-14;(b)cooling capacity in kW (Btu/h);(c)heating capacity in kW (Btu/h);(d)seasonal energy efficiency ratio;(e)heating seasonal performance factor; and(f)phase of electric current.8 | Single package central heat pumps that are three-phase and manufactured on or after January 1, 2026 | 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted for information set out in paragraphs (b) to (g) | (a)type;(b)cooling capacity in kW (Btu/h);(c)heating capacity at 8.3°C (47°F) in kW (Btu/h);(d)seasonal energy efficiency ratio 2;(e)heating seasonal performance factor 2 for region V;(f)heating capacity at -15°C (5°F) in kW (Btu/h);(g)coefficient of performance at -15°C (5°F); and(h)phase of electric current.note
206.1Early compliance#
A single package central heat pump that is manufactured on or after January 1, 2025 and before January 1, 2026 is deemed to satisfy the requirements of sections 205 and 206 if it satisfies the requirements of those sections that would have applied to the single package central heat pump if it had been manufactured on or after January 1, 2026.note
Subdivision F — Single Package Vertical Heat Pumps
207Definition of single package vertical heat pump#
In this Subdivision, single package vertical heat pump means a single package commercial heat pump that is encased, that has its major components arranged vertically and that
(b)is intended for mounting through, or on either side of, an exterior wall.
208Energy-using product#
(1)A single package vertical heat pump is prescribed as an energy-using product.
note
209Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to single package vertical heat pumps described in column 1 that are manufactured during the periods set out in column 3.
(2)A single package vertical heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C746-17 that are applicable to a single package vertical heat pump as defined in section 207.Item | Column 1 | Column 2 | Column 3Energy-using Product | Energy Efficiency Standard | Period of manufacture1 | Single package vertical heat pumps that have a cooling capacity of < 19 kW (65,000 Btu/h) | Energy efficiency ratio ≥ 9.0Heating coefficient of performance ≥ 3.0 | On or after January 1, 2011 and before September 23, 20192 | Single package vertical heat pumps that have a cooling capacity of < 19 kW (65,000 Btu/h) | Energy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.3 | On or after September 23, 20193 | Single package vertical heat pumps that have a cooling capacity of ≥ 19 kW (65,000 Btu/h) and < 39.5 kW (135,000 Btu/h) | Energy efficiency ratio ≥ 8.9Heating coefficient of performance ≥ 3.0 | On or after January 1, 2011 and before October 9, 20154 | Single package vertical heat pumps that have a cooling capacity of ≥ 19 kW (65,000 Btu/h) and < 39.5 kW (135,000 Btu/h | Energy efficiency ratio ≥ 10.0Heating coefficient of performance ≥ 3.0 | On or after October 9, 20155 | Single package vertical heat pumps that have a cooling capacity of ≥ 39.5 kW (135,000 Btu/h) and < 70 kW (240,000 Btu/h) | Energy efficiency ratio ≥ 8.6Heating coefficient of performance ≥ 2.9 | On or after January 1, 2011 and before October 9, 20166 | Single package vertical heat pumps that have a cooling capacity of ≥ 39.5 kW (135,000 Btu/h) and < 70 kW (240,000 Btu/h) | Energy efficiency ratio ≥ 10.0Heating coefficient of performance ≥ 3.0 | On or after October 9, 2016
note
210Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C746-17 and provided to the Minister in respect of a single package vertical heat pump:
(a)its classification set out in columns II and III of Table 2 to CSA C746-17;
(b)its cooling capacity, expressed in kilowatts (British thermal units per hour);
(c)its energy efficiency ratio;
(d)its heating capacity, expressed in kilowatts (British thermal units per hour); and
(e)its heating coefficient of performance.
note
Subdivision G — Split System Central Heat Pumps
211Definitions#
The following definitions apply in this Subdivision.
off mode power consumption means the power consumption when the unit is connected to mains power but is not providing cooling or heating. (consommation d’énergie en mode arrêt)
split system central heat pump means a single-phase or three-phase air-to-air central heat pump that is a split system and that has a cooling capacity of less than 19 kW (65,000 Btu/h). (thermopompe centrale bibloc)
split-system heat pump [Repealed, SOR/2022-265, s. 19]
note
212Energy-using product#
(1)A split system central heat pump is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 213, a split system central heat pump is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.
note
213Energy efficiency standards — single-phase#
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase split system central heat pumps described in column 1 that are manufactured during the periods set out in column 4.
(1.1)The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase split system central heat pumps described in column 1 that are manufactured during the periods set out in column 4.
(2)A split system central heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split system central heat pump as defined in section 211. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Split system central heat pumps, other than those that are small-duct and high-velocity | CSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 14.0Heating seasonal performance factor (Region V) ≥ 7.1Off mode power consumption ≤ 33 W | On or after December 31, 1998 and before January 1, 20232 | Split system central heat pumps that are small-duct and high-velocity | CSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor10 C.F.R. Appendix M for off mode power consumption | Seasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.3Off mode power consumption ≤ 30 W | On or after December 31, 1998 and before January 1, 20233 | Split system central heat pumps, other than those that are small-duct and high-velocity or space-constrained | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 14.3Heating seasonal performance factor 2 (Region V) ≥ 6.0Off mode power consumption ≤ 33 W | On or after January 1, 2023 and before January 1, 20254 | Split system central heat pumps that are small-duct and high-velocity | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 12.0Heating seasonal performance factor 2 (Region V) ≥ 4.9Off mode power consumption ≤ 30 W | On or after January 1, 2023 and before January 1, 20255 | Split system central heat pumps that are space-constrained | 10 C.F.R. Appendix M1 | Seasonal energy efficiency ratio 2 ≥ 11.9Heating seasonal performance factor 2 (Region V) ≥ 5.0Off mode power consumption ≤ 33 W | On or after January 1, 2023 and before January 1, 20256 | Split system central heat pumps, other than those that are small-duct and high-velocity or space-constrained | 10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F) | Seasonal energy efficiency ratio 2 ≥ 14.3Heating seasonal performance factor 2 (Region V) ≥ 6.0Off mode power consumption ≤ 33 W | On or after January 1, 20257 | Split system central heat pumps that are small-duct and high-velocity | 10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F) | Seasonal energy efficiency ratio 2 ≥ 12.0Heating seasonal performance factor 2 (Region V) ≥ 4.9Off mode power consumption ≤ 30 W | On or after January 1, 20258 | Split system central heat pumps that are space-constrained | 10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F) | Seasonal energy efficiency ratio 2 ≥ 11.9Heating seasonal performance factor 2 (Region V) ≥ 5.0Off mode power consumption ≤ 33 W | On or after January 1, 2025 | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Split system central heat pumps, other than those that are small-duct and high-velocity | CSA C656-14 | Seasonal energy efficiency ratio ≥ 14.0Heating seasonal performance factor (Region V) ≥ 7.1 | On or after December 31, 1998 and before January 1, 20262 | Split system central heat pumps that are small-duct and high-velocity | CSA C656-14 | Seasonal energy efficiency ratio ≥ 12.0Heating seasonal performance factor (Region V) ≥ 6.3 | On or after December 31, 1998 and before January 1, 20263 | Split system central heat pumps, other than those that are space-constrained or small-duct and high-velocity | 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted | Seasonal energy efficiency ratio 2 ≥ 14.3Heating seasonal performance factor 2 (Region V) ≥ 6.0 | On or after January 1, 20264 | Split system central heat pumps that are space-constrained | 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted | Seasonal energy efficiency ratio 2 ≥ 13.9Heating seasonal performance factor 2 (Region V) ≥ 5.6 | On or after January 1, 20265 | Split system central heat pumps that are small-duct and high-velocity | 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted | Seasonal energy efficiency ratio 2 ≥ 14.0Heating seasonal performance factor 2 (Region V) ≥ 5.5 | On or after January 1, 2026
note
214Information#
For the purposes of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected and provided to the Minister in respect of a split system central heat pump described in column 1 and, if applicable, the information must be collected in accordance with the standard set out in column 2. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Split system central heat pumps that are single-phase and manufactured on or after December 31, 1998 and before January 1, 2023 | CSA C656-14 for information set out in paragraphs (a) to (e)10 C.F.R. Appendix M for off mode power consumption | (a)product classification set out in column II of Table 1 to CSA C656-14;(b)cooling capacity in kW (Btu/h);(c)heating capacity in kW (Btu/h);(d)seasonal energy efficiency ratio;(e)heating seasonal performance factor and the region for the factor;(f)off mode power consumption, in watts; and(g)phase of electric current.2 | Split system central heat pumps that are single-phase and manufactured on or after January 1, 2023 and before January 1, 2025 | 10 C.F.R. Appendix M1 for information set out in paragraphs (b) to (i) | (a)type;(b)cooling capacity in kW (Btu/h);(c)heating capacity at 8.3°C (47°F) in kW (Btu/h);(d)seasonal energy efficiency ratio 2;(e)information that indicates whether the results from the very low temperature heating test (H4) were included in the calculation of the heating seasonal performance factor 2 for Region V;(f)heating seasonal performance factor 2 for Region V;(g)heating capacity at -15°C (5°F) in kW (Btu/h), if the very low temperature heating test (H4) was conducted;(h)coefficient of performance at -15°C (5°F), if the very low temperature heating test (H4) was conducted;(i)off mode power consumption, in watts; and(j)phase of electric current.3 | Split system central heat pumps that are single-phase and manufactured on or after January 1, 2025 | 10 C.F.R. Appendix M1, except that the very low temperature heating test (H4) must be conducted for information set out in paragraphs (b) to (h) | (a)type;(b)cooling capacity in kW (Btu/h);(c)heating capacity at 8.3°C (47°F) in kW (Btu/h);(d)seasonal energy efficiency ratio 2;(e)heating seasonal performance factor 2 for Region V;(f)heating capacity at -15°C (5°F) in kW (Btu/h);(g)coefficient of performance at -15°C (5°F);(h)off mode power consumption, in watts; and(i)phase of electric current.4 | Split system central heat pumps that are three-phase and manufactured on or after December 31, 1998 and before January 1, 2026 | CSA C656-14 for information set out in paragraphs (a) to (e) | (a)product classification set out in column II of Table 1 to CSA C656-14;(b)cooling capacity in kW (Btu/h);(c)heating capacity in kW (Btu/h);(d)seasonal energy efficiency ratio;(e)heating seasonal performance factor and the region for the factor; and(f)phase of electric current.5 | Split system central heat pumps that are three-phase and manufactured on or after January 1, 2026 | 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted for information set out in paragraphs (b) to (g) | (a)type;(b)cooling capacity in kW (Btu/h);(c)heating capacity at 8.3°C (47°F) in kW (Btu/h);(d)seasonal energy efficiency ratio 2;(e)heating seasonal performance factor 2 for region V;(f)heating capacity at -15°C (5°F) in kW (Btu/h);(g)coefficient of performance at -15°C (5°F); and(h)phase of electric current.note
214.1Early compliance#
A split system central heat pump that is manufactured on or after January 1, 2025 and before January 1, 2026 is deemed to satisfy the requirements of sections 213 and 214 if it satisfies the requirements of those sections that would have applied to the split system central heat pump if it had been manufactured on or after January 1, 2026.note
Division 4 — Furnaces, Fireplaces, Unit Heaters and Recovery Ventilators
Interpretation
256.1Definitions#
The following definitions apply in this Division.
FER means, in respect of a gas furnace, an oil-fired furnace or an electric furnace, the fan energy rating, which is the annual electrical energy consumption of the furnace fan normalized by annual fan operating hours and the product’s maximum airflow (Qmax). (FER)
10 C.F.R. Appendix AA means Appendix AA to Subpart B of Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Furnace Fans, as amended from time to time. (appendice AA 10 C.F.R.)
10 C.F.R. §430.32(y) means Table 1 to paragraph 430.32(y) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(y))
note
Subdivision A — Gas Furnaces
257Definitions#
The following definitions apply in this Subdivision.
CSA P.2 [Repealed, SOR/2018-201, s. 34]
gas furnace means an automatic operating gas-fired central forced air furnace that uses propane or natural gas and has an input rate of not more than 117.23 kW (400,000 Btu/h). It does not include a furnace for a park model trailer or a recreational vehicle. (générateur d’air chaud à gaz)
gas furnace for relocatable buildings means a gas furnace that is intended for use in a temporary modular building that can be relocated from one site to another and is marked for use in relocatable buildings. (générateur d’air chaud à gaz pour bâtiments relocalisables)
manufactured home means a factory-built, single- or multiple-section, one-storey dwelling that
(a)is designed and constructed for year-round occupancy;
(b)is designed to be transported to its installation site; and
(c)is ready for occupancy when it is installed in accordance with the manufacturer’s installation instructions. (maison usinée)
replacement non-condensing gas furnace means a non-condensing gas furnace that is marked for use as a replacement for a non-condensing gas furnace in a manufactured home. (générateur d’air chaud à gaz sans condensation de remplacement)
space-constrained, with respect to a gas furnace, means one that
(a)uses single-phase electric current; and
(b)has an outdoor or indoor unit
(i)that has an overall displacement that is — or two or more overall exterior dimensions that are — substantially smaller than those of other units of a similar heating capacity that are usually installed in single-family homes, and
(ii)with respect to which an increase in the overall displacement or two or more overall exterior dimensions would result in a considerable increase in the usual cost of installation or in a significant loss in the utility of the product to the consumer. (à espace restreint)
through-the-wall means, with respect to a gas furnace, one that is designed and marketed to be installed in an opening in an exterior wall that is fitted with a weatherized sleeve. (mural)
note
258Energy-using product#
(1)A gas furnace is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 259, a gas furnace is not considered to be an energy-using product if
(a)it was manufactured before February 3, 1995;
(b)it is a gas furnace for relocatable buildings that is manufactured before July 3, 2019; or
(c)it is a replacement non-condensing gas furnace that is manufactured before July 3, 2019.
note
259Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to gas furnaces described in column 1 that are manufactured during the periods set out in column 4.
(2)A gas furnace complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a gas furnace as defined in section 257. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and use single-phase electric current | CSA 2.3 | Annual fuel utilization efficiency ≥ 78% | On or after February 3, 1995 and before December 31, 20092 | Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and do not have an integrated cooling component | CSA P.2 | Annual fuel utilization efficiency ≥ 90% | On or after December 31, 2009 and before July 3, 20192.1 | Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and do not have an integrated cooling component | CSA P.2, for annual fuel utilization efficiency10 C.F.R. Appendix AA, for FER | Annual fuel utilization efficiency ≥ 95%FER ≤ FER for product class “Non-Weatherized, Condensing Gas Furnace Fan (NWG-C)”, set out in 10 C.F.R. §430.32(y) | On or after July 3, 20193 | Gas furnaces that are outdoor furnaces, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling component | CSA P.2 | Annual fuel utilization efficiency ≥ 78% | On or after December 31, 2009 and before July 3, 20193.1 | Gas furnaces that are outdoor furnaces, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling component | CSA P.2, for annual fuel utilization efficiency10 C.F.R. Appendix AA, for FER | Annual fuel utilization efficiency ≥ 78%FER ≤ FER for product class “Weatherized Non-Condensing Gas Furnace Fan (WG-NC)”, set out in 10 C.F.R. §430.32(y) | On or after July 3, 20194 | Gas furnaces that are through-the-wall, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling component | CSA P.2 | Annual fuel utilization efficiency ≥ 78% | On or after December 31, 2009 and before December 31, 20125 | Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that are through-the-wall, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling component | CSA P.2 | Annual fuel utilization efficiency ≥ 90% | On or after December 31, 2012 and before January 1, 20245.1 | Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that are space-constrained, have an input rate of ≤ 65.92 kW (225,000 Btu/h) and have an integrated cooling component | CSA P.2 | Annual fuel utilization efficiency ≥ 90% | On or after January 1, 20246 | Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and use three-phase electric current | CSA 2.3 | Annual fuel utilization efficiency ≥ 78%orThermal efficiency ≥ 80% | On or after February 3, 19957 | Gas furnaces that have an input rate of > 65.92 kW (225,000 Btu/h) but ≤ 117.23 kW (400,000 Btu/h) | CSA 2.3 | Thermal efficiency ≥ 80% | On or after February 3, 19958 | Gas furnaces for relocatable buildings | CSA P.2 for annual fuel utilization efficiency10 C.F.R. Appendix AA, for fan energy rating | Annual fuel utilization efficiency ≥ 80%FER ≤ FER for product class “Mobile Home Non-Weatherized, Non-Condensing Gas Furnace Fan (MH-NWG-NC)”, set out in 10 C.F.R. §430.32(y) | On or after July 3, 20199 | Replacement non-condensing gas furnaces | CSA P.2 for annual fuel utilization efficiency10 C.F.R. Appendix AA, for fan energy rating | Annual fuel utilization efficiency ≥ 80%FER ≤ FER for product class “Mobile Home Non-Weatherized, Non-Condensing Gas Furnace Fan (MH-NWG-NC)”, set out in 10 C.F.R. §430.32(y) | On or after July 3, 2019
note
260Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas furnace described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured before December 31, 2009 | CSA 2.3 | (a)heating capacity, in kW (Btu/h); and(b)annual fuel utilization efficiency.2 | Gas furnaces, other than those that are through-the-wall, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured on or after December 31, 2009 and before July 3, 2019 | CSA P.2 | (a)maximum heat input and output nominal capacities, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)information that indicates whether product has an integrated cooling component;(d)if product has an integrated cooling component, information that indicates whether the product is outdoor or through-the-wall;(e)standby power, in W;(f)power burner’s PE and VPE; and(g)type of fuel used.2.1 | Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured on or after July 3, 2019 | CSA P.2, for information set out in paragraphs (a) to (e)10 C.F.R. Appendix AA, for information set out in paragraphs (f) and (g) | (a)maximum heat input and output nominal capacities, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)information that indicates whether product has an integrated cooling component;(d)if product has an integrated cooling component, information that indicates whether the product is outdoor or through-the-wall;(e)type of fuel used;(f)FER, expressed in W/472 L/s (W/1,000 ft³/min);(g)product’s maximum airflow (Qmax), expressed in L/s (ft³/min); and(h)if applicable, information that indicates whether product is gas furnace for relocatable buildings or is replacement non-condensing gas furnace.2.2 | Gas furnaces that are through-the-wall, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current, that have an integrated cooling component and that are manufactured on or after December 31, 2009 and before January 1, 2024 | CSA P.2 for information set out in paragraphs (a) to (c) | (a)maximum heat input and output nominal capacities, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)type of fuel used; and(d)if applicable, information that indicates whether product is gas furnace for relocatable buildings or is replacement non-condensing gas furnace.2.3 | Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that are space-constrained, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that have an integrated cooling component and that are manufactured on or after January 1, 2024 | CSA P.2 for information set out in paragraphs (a) to (c) | (a)maximum heat input and output nominal capacities, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)type of fuel used; and(d)type of blower fan motor, namely brushless permanent magnet, permanent split-capacitor or other.3 | Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and that use three-phase electric current | CSA 2.3 | (a)heating capacity, in kW (Btu/h); and(b)annual fuel utilization efficiency or thermal efficiency.4 | Gas furnaces that have an input rate of > 65.92 kW (225,000 Btu/h) but ≤ 117.23 kW (400,000 Btu/h) | CSA 2.3 | (a)heating capacity, in kW (Btu/h); and(b)thermal efficiency.5 | Gas furnaces for relocatable buildings manufactured on or after January 1, 2024 | CSA P.2 for information set out in paragraphs (a) to (c)10 C.F.R. Appendix AA for information set out in paragraphs (d) and (e) | (a)maximum heat input and output nominal capacities, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)type of fuel used;(d)FER, expressed in W/472 L/s (W/1,000 ft3/min); and(e)product’s maximum airflow (Qmax), expressed in L/s (ft3/min).6 | Replacement non-condensing gas furnaces manufactured on or after January 1, 2024 | CSA P.2 for information set out in paragraphs (a) to (c)10 C.F.R. Appendix AA for information set out in paragraphs (d) and (e) | (a)maximum heat input and output nominal capacities, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)type of fuel used;(d)FER, expressed in W/472 L/s (W/1,000 ft3/min); and(e)product’s maximum airflow (Qmax), expressed in L/s (ft3/min).note
Subdivision B — Oil-Fired Furnaces
261Definitions#
The following definitions apply in this Subdivision.
oil-fired furnace means a warm-air furnace, other than a furnace for a mobile home or for a recreational vehicle, that has an input rate of not more than 65.92 kW (225,000 Btu/h) and that is either
(a)exclusively oil-fired; or
(b)capable of being fired, at the choice of the user, by either oil or another fuel. (générateur d’air chaud à mazout)
262Energy-using product#
(1)An oil-fired furnace is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 263, an oil-fired furnace is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.
263Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to oil-fired furnaces that are manufactured during the periods set out in column 3.
(2)An oil-fired furnace complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to an oil-fired furnace as defined in section 261. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA B212 | Seasonal energy utilization efficiency ≥ 78% | On or after December 31, 1998 and before January 1, 20172 | CSA P.2 | Annual fuel utilization efficiency ≥ 83% | On or after January 1, 2017 and before July 3, 20193 | CSA P.2, for annual fuel utilization efficiency10 C.F.R. Appendix AA, for FER | Annual fuel utilization efficiency ≥ 83%FER ≤ FER for product class “Non-Weatherized, Non-Condensing Oil Furnace Fan (NWO-NC)”, set out in 10 C.F.R. §430.32(y) | On or after July 3, 2019
note
264Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an oil-fired furnace described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Oil-fired furnaces that are manufactured on or after December 31, 1998 and before January 1, 2017 | CSA B212 | (a)input rate, in kW (Btu/h); and(b)seasonal energy utilization efficiency.2 | Oil-fired furnaces that are manufactured on or after January 1, 2017 and before July 3, 2019 | CSA P.2 | (a)input rate, in kW (Btu/h); and(b)annual fuel utilization efficiency.3 | Oil-fired furnaces that are manufactured on or after July 3, 2019 | CSA P.2, for information set out in paragraphs (a) and (b)10 C.F.R. Appendix AA, for information set out in paragraphs (c) and (d) | (a)input rate, in kW (Btu/h);(b)annual fuel utilization efficiency;(c)FER, expressed in W/472 L/s (W/1,000 ft³/min); and(d)maximum airflow (Qmax), expressed in L/s (ft³/min).note
Subdivision C — Gas Fireplaces
265Definitions#
The following definitions apply in this Subdivision.
CSA P.4.1-15 means the CSA standard CAN/CSA P.4.1-15 entitled Testing Method for Measuring Annual Fireplace Efficiency. (CSA P.4.1-15)
decorative gas fireplace means a vented fireplace that is fuelled by natural gas or propane, is marked for decorative use only and is not equipped with a thermostat or intended for use as a heater. (foyer à gaz décoratif)
gas fireplace means a decorative gas fireplace or a heating gas fireplace. (foyer à gaz)
heating gas fireplace means a vented fireplace that is fuelled by natural gas or propane and is not a decorative gas fireplace. (foyer à gaz de chauffage)
note
266Energy-using product#
(1)A gas fireplace is prescribed as an energy-using product.
(2)However, a gas fireplace is not considered to be an energy-using product
(a)for the purposes of sections 4, 5 and 7, unless it is manufactured on or after June 1, 2003; or
(b)for the purpose of section 266.1, unless it is manufactured on or after January 1, 2020.
note
266.1Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to gas fireplaces described in column 1 that are manufactured during the periods set out in column 4.
(2)A gas fireplace complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a gas fireplace as defined in section 265.Item | Column 1 | Column 2 | Column 3 | Column 4Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Decorative gas fireplaces | N\A | The product must be capable of(a)automatically extinguishing pilot flame when main gas burner flame is established;(b)automatically extinguishing pilot flame when main gas burner flame is extinguished;(c)if it has the capability of being manually switched to a mode of continuous pilot operation, preventing pilot flame from burning continuously for more than seven days; or(d)in absence of any automatic or manual adjustment to main gas burner flame height or appearance, preventing any ignition source for the main gas burner flame from operating continuously for more than seven days.Must have a direct vent configuration, unless it is marked for replacement use only. | On or after January 1, 20202 | Heating gas fireplaces | CSA P.4.1-15 for fireplace efficiency | Fireplace efficiency ≥ 50%The product must be capable of(a)automatically extinguishing pilot flame when main gas burner flame is established;(b)automatically extinguishing pilot flame when main gas burner flame is extinguished;(c)if it has the capability of being manually switched to a mode of continuous pilot operation, preventing pilot flame from burning continuously for more than seven days; or(d)in absence of any automatic or manual adjustment to main gas burner flame height or appearance, preventing any ignition source for the main gas burner flame from operating continuously for more than seven days. | On or after January 1, 2020
note
267Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a gas fireplace:
(a)the type of fuel it uses;
(b)its maximum and minimum input rates, expressed in kilowatts (British thermal units per hour);
(c)the fireplace efficiency;
(d)information that indicates whether it is freestanding, zero-clearance or an insert;
(e)the type of ignition system it uses;
(f)the venting configuration the product has, namely, natural venting, direct venting or powered venting;
(g)information that indicates whether the product is a decorative gas fireplace or a heating gas fireplace; and
(h)if the product is a decorative gas fireplace that is manufactured on or after January 1, 2020, information that indicates whether it is intended for use as a replacement unit.
(2)The information must be collected in accordance with
(b)CSA P.4.1-15, if the product is manufactured on or after January 1, 2017.
note
Subdivision D — Gas-Fired Unit Heaters
268Definitions#
The following definitions apply in this Subdivision.
gas-fired unit heater means a self-contained, automatically controlled, vented, gas-burning appliance that distributes warmed air without the use of ducts and that has an input rate of not more than 2 931 kW (10,000,000 Btu/h). (aérotherme à gaz)
269Energy-using product#
(1)A gas-fired unit heater is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 270, a gas-fired unit-heater is not considered to be an energy-using product unless it is manufactured on or after August 8, 2008.
270Energy efficiency standards#
(1)The following energy efficiency standards apply to a gas-fired unit heater:
(a)its thermal efficiency must be at least 80% at the maximum heat input nominal capacity; and
(b)it must be equipped with an intermittent ignition device and
(i)a power-vented system,
(ii)an automatic vent damper, or
(iii)an automatic flue damper.
(2)A gas-fired unit heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA P.11 that are applicable to a gas-fired unit heater as defined in section 268.
271Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA P.11 and provided to the Minister in respect of a gas-fired unit heater:
(a)the type of fuel it uses;
(b)the type of ignition system it has;
(c)the venting configuration it has, namely, a power-vented system, an automatic vent damper or an automatic flue damper;
(d)its maximum heat input and output nominal capacities, expressed in kilowatts;
(e)its thermal efficiency when at the maximum heat input nominal capacity;
(f)its electricity consumption, expressed in kilowatt hours, when at the maximum nominal heat input capacity; and
Subdivision E — Electric Furnaces
272Definition of electric furnace#
In this Subdivision, electric furnace means an automatic operating central forced air furnace that uses single-phase electric current to heat one or more electrical resistance heating elements and has an input rate of not more than 65.92 kW (225,000 Btu/h). It does not include an electric furnace that
(a)produces at least 300 Pa (1.2 inches of water) external static pressure when operated at an air volume rate of 104 to 165 L/s (220 to 350 ft3/min) per nominal ton of cooling in the highest default cooling airflow-control setting; and
(b)uses room outlets that produce velocities greater than 5 m/s (1,000 ft/min) and each have an area less than 39 cm2 (6 square inches).
note
273Energy-using product#
(1)An electric furnace is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 274, an electric furnace is not considered to be an energy-using product unless it is manufactured on or after July 3, 2019.
note
274Energy efficiency standard#
(1)The energy efficiency standard that applies to an electric furnace is that its FER must be less than or equal to the FER for product class “Non-Weatherized, Electric Furnace/Modular Blower Fan”, set out in 10 C.F.R. §430.32(y).
(2)An electric furnace complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix AA that are applicable to an electric furnace as defined in section 272.
note
275Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix AA and provided to the Minister in respect of an electric furnace:
(a)its maximum heat input nominal capacity, expressed in kilowatts (British thermal units per hour);
(c)its maximum airflow (Qmax), expressed in L/s (ft3/min).
note
Subdivision F — Recovery Ventilators
Interpretation
276Definitions#
The following definitions apply in this Subdivision.
CSA C439-18 means the CSA standard CAN/CSA-C439-18 entitled Laboratory methods of test for rating the performance of heat/energy-recovery ventilators. (CSA C439-18)
energy-recovery ventilator means a factory-built packaged unit that has fans or blowers, has a maximum rated airflow of not more than 142 L/s (300 ft3/min) at 0°C and transfers heat and moisture between two isolated airstreams. (ventilateur-récupérateur d’énergie)
heat-recovery ventilator means a factory-built packaged unit that has fans or blowers, has a maximum rated airflow of not more than 142 L/s (300 ft3/min) at 0°C and transfers heat between two isolated airstreams. (ventilateur-récupérateur de chaleur)
sensible heat recovery efficiency means, in respect of an energy-recovery ventilator or a heat-recovery ventilator, the ratio of the net sensible energy recovered by the unit’s supply airstream, as adjusted to account for the unit’s external and internal energy gains and losses, to the maximum sensible energy that would be recovered if the unit had an infinite transfer area. (efficacité de récupération de chaleur sensible)
note
Energy-recovery Ventilators
277Energy-using product#
(1)An energy-recovery ventilator is prescribed as an energy-using product.
(2)However, for the purposes of sections 4 and 5, an energy-recovery ventilator is not considered to be an energy-using product unless it is manufactured on or after January 1, 2020.
note
278Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C439-18 and be provided to the Minister in respect of an energy-recovery ventilator:
(a)its maximum rated airflow at 0°C;
(c)unless the unit is marked for use only where the outdoor design temperature is greater than or equal to -10°C, its sensible heat recovery efficiency at -25°C and the associated net supply airflow, expressed in L/s.
note
Heat-recovery Ventilators
279Energy-using product#
(1)A heat-recovery ventilator is prescribed as an energy-using product.
(2)However, for the purposes of sections 4 and 5, a heat-recovery ventilator is not considered to be an energy-using product unless it is manufactured on or after January 1, 2020.
note
280Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C439-18 and be provided to the Minister in respect of a heat-recovery ventilator:
(a)its maximum rated airflow at 0°C;
(c)unless the unit is marked for use only where the outdoor design temperature is greater than or equal to -10°C, its sensible heat recovery efficiency at -25°C and the associated net supply airflow, expressed in L/s.
note
Division 5 — Boilers
Interpretation
314Definitions#
The following definitions apply in this Division.
ASHRAE 103 means the ANSI/ASHRAE standard 103-2007 entitled Method of Testing for Annual Fuel Utilization Efficiency of Residential Central Furnaces and Boilers. (ASHRAE 103)
automatic water temperature adjustment device means a device that
(a)adjusts the temperature of the water supplied by a boiler to ensure that an incremental change in inferred heat load produces a corresponding incremental change in the temperature of the water supplied or, if the boiler fires at a single input rate, automatically allows the burner or heating element to fire only when the device has determined that the inferred heat load cannot be met by the residual heat of the water in the system; and
(b)when there is no inferred heat load, limits the water temperature in the boiler to not more than 60°C. (dispositif automatique de réglage de la température de l’eau)
10 C.F.R. Appendix A means Appendix A to Subpart E, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Thermal Efficiency and Combustion Efficiency of Commercial Packaged Boilers, as amended from time to time. (appendice A 10 C.F.R.)
note
Subdivision A — Gas Boilers
315Definitions#
The following definitions apply in this Subdivision.
CSA P.2 [Repealed, SOR/2019-164, s. 14]
gas boiler means a boiler that uses exclusively propane or natural gas, is intended for application in a low pressure steam, or hot water, central heating system and has an input rate of not more than 2 930.71 kW (10,000,000 Btu/h). (chaudière à gaz)
note
315.1Type#
For the purpose of these Regulations, a gas boiler is one of the following types:
(a)household, if it has an input rate of less than 87.92 kW (300,000 Btu/h); or
(b)commercial, if it is has an input rate of greater than or equal to 87.92 kW (300,000 Btu/h) but not more than 2 930.71 kW (10,000,000 Btu/h).
note
316Energy-using product#
(1)A gas boiler is prescribed as an energy-using product.
(2)However, a gas boiler is not considered to be an energy-using product
(a)for the purpose of section 4 unless
(i)it is a household gas boiler that is manufactured on or after June 30, 1999, or
(ii)it is a commercial gas boiler that is manufactured on or after January 1, 2025; and
(b)for the purposes of sections 5 and 317 unless
(i)it is a household gas boiler that is manufactured on or after December 31, 1998, or
(ii)it is a commercial gas boiler that is manufactured on or after January 1, 2025.
note
317Energy efficiency standards — household#
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to household gas boilers described in column 1 that are manufactured during the periods set out in column 4.
(2)A household gas boiler complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 1 that are applicable to a gas boiler as defined in section 315.
(3)The energy efficiency standards set out in column 2 of Table 2 to this section apply to commercial gas boilers described in column 1 that are manufactured on or after January 1, 2025.
(4)A commercial gas boiler complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix A that are applicable to a gas boiler as defined in section 315.Item | Column 1 | Column 2 | Column 3 | Column 4Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Household gas boilers that are intended for low pressure steam systems | CGA P.2 | Annual fuel utilization efficiency ≥ 75% | On or after December 31, 1998 and before September 1, 20102 | Household gas boilers that are intended for low pressure steam systems | CSA P.2 for annual fuel utilization efficiency | Annual fuel utilization efficiency ≥ 80%No continuously burning pilot light | On or after September 1, 2010 and before January 15, 20212.1 | Household gas boilers that are intended for low pressure steam systems | CSA P.2 for annual fuel utilization efficiency, standby power and off-mode power | Annual fuel utilization efficiency ≥ 82%No continuously burning pilot lightStandby power ≤ 8 WOff-mode power ≤ 8 W | On or after January 15, 20213 | Household gas boilers that are intended for hot water systems | CGA P.2 | Annual fuel utilization efficiency ≥ 80% | On or after December 31, 1998 and before September 1, 20104 | Household gas boilers that are intended for hot water systems | CSA P.2 for annual fuel utilization efficiency | Annual fuel utilization efficiency ≥ 82%No continuously burning pilot light | On or after September 1, 2010 and before September 1, 20125 | Household gas boilers that are intended for hot water systems and have tankless domestic water heating coils | CSA P.2 for annual fuel utilization efficiency | Annual fuel utilization efficiency ≥ 82%No continuously burning pilot light | On or after September 1, 2012 and before July 1, 20235.1 | Household gas boilers that are intended for hot water systems and have tankless domestic water heating coils | CSA P.2 for annual fuel utilization efficiency, standby power and off-mode power | Annual fuel utilization efficiency ≥ 90%No continuously burning pilot lightStandby power ≤ 9 WOff-mode power ≤ 9 W | On or after July 1, 20236 | Household gas boilers that are intended for hot water systems and do not have tankless domestic water heating coils | CSA P.2 for annual fuel utilization efficiency | Annual fuel utilization efficiency ≥ 82%No continuously burning pilot lightEquipped with automatic water temperature adjustment device and not operable without the device | On or after September 1, 2012 and before July 1, 20237 | Household gas boilers that are intended for hot water systems and do not have tankless domestic water heating coils | CSA P.2 for annual fuel utilization efficiency, standby power and off-mode power | Annual fuel utilization efficiency ≥ 90%No continuously burning pilot lightEquipped with automatic water temperature adjustment device and not operable without the deviceStandby power ≤ 9 WOff-mode power ≤ 9 W | On or after July 1, 2023Item | Column 1 | Column 2Energy-using Product | Energy Efficiency Standard1 | Commercial gas boilers that have an input rate of ≥ 87.92 kW (300,000 Btu/h) but ≤ 732.68 kW (2,500,000 Btu/h) and are intended for hot water systems | Thermal efficiency ≥ 90%2 | Commercial gas boilers that have an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and are intended for hot water systems | Combustion efficiency ≥ 90%3 | Commercial gas boilers that have an input rate of ≥ 87.92 kW (300,000 Btu/h) but ≤ 732.68 kW (2,500,000 Btu/h) and are intended for low pressure steam systems | Thermal efficiency ≥ 81%4 | Commercial gas boilers that have an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and are intended for low pressure steam systems | Thermal efficiency ≥ 82%
note
318Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas boiler described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Household gas boilers manufactured on or after December 31, 1998 and before September 1, 2010 | CGA P.2 | (a)type of fuel used;(b)type of central heating system for which product is intended;(c)input rate, in kW (Btu/h); and(d)annual fuel utilization efficiency.2 | Household gas boilers manufactured on or after September 1, 2010 and before January 15, 2021 and intended for low pressure steam systems | CSA P.2 | (a)type of fuel used;(b)maximum heat input and output nominal capacities, in kW (Btu/h); and(c)annual fuel utilization efficiency.3 | Household gas boilers manufactured on or after January 15, 2021 and intended for low pressure steam systems | CSA P.2 | (a)type of fuel used;(b)maximum heat input and output nominal capacities, in kW (Btu/h);(c)annual fuel utilization efficiency;(d)standby power, in W; and(e)off-mode power, in W.4 | Household gas boilers, other than those intended for low pressure steam systems, manufactured on or after September 1, 2010 and before July 1, 2023 | CSA P.2 for information set out in paragraphs (a) to (c) | (a)type of fuel used;(b)maximum heat input and output nominal capacities, in kW (Btu/h);(c)annual fuel utilization efficiency; and(d)if product is manufactured on or after September 1, 2012 and before July 1, 2023,(i)information that indicates whether product has tankless domestic water heating coils, and(ii)type of automatic water temperature adjustment device it has, if any.5 | Household gas boilers, other than those intended for low pressure steam systems, manufactured on or after July 1, 2023 | CSA P.2 for information set out in paragraphs (a) to (e) | (a)type of fuel used;(b)maximum heat input and output nominal capacities, in kW (Btu/h);(c)annual fuel utilization efficiency;(d)standby power, in W;(e)off-mode power, in W;(f)information that indicates whether product has tankless domestic water heating coils; and(g)type of automatic water temperature adjustment device it has, if any.6 | Commercial gas boilers manufactured on or after January 1, 2025 | 10 C.F.R. Appendix A | (a)type of central heating system for which product is intended;(b)maximum heat input nominal capacity, in kW (Btu/h); and(c)thermal efficiency or, if product has an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and is intended for hot water systems, combustion efficiency.note
Subdivision B — Oil-Fired Boilers
319Definitions#
The following definitions apply in this Subdivision.
oil-fired boiler means a boiler that is intended for application in a low pressure steam, or hot water, central heating system, has an input rate of less than 2 930.71 kW (10,000,000 Btu/h) and is
(a)exclusively oil-fired; or
(b)capable of being fired, at the choice of the user, by either oil or another fuel. (chaudière à mazout)
note
319.1Type#
For the purpose of these Regulations, an oil-fired boiler is one of the following types:
(a)household, if it has an input rate of less than 87.92 kW (300,000 Btu/h); or
(b)commercial, if it is has an input rate of greater than or equal to 87.92 kW (300,000 Btu/h) but not more than 2 930.71 kW (10,000,000 Btu/h).
note
320Energy-using product#
(1)An oil-fired boiler is prescribed as an energy-using product.
(2)However, an oil-fired boiler is not considered to be an energy-using product
(a)for the purpose of section 4, unless
(i)it is a household oil-fired boiler that is manufactured on or after June 30, 1999, or
(ii)it is a commercial oil-fired boiler that is manufactured on or after January 1, 2025; and
(b)for the purposes of sections 5 and 321, unless
(i)it is a household oil-fired boiler that is manufactured on or after December 31, 1998, or
(ii)it is a commercial oil-fired boiler that is manufactured on or after January 1, 2025.
note
321Energy efficiency standards — household#
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to household oil-fired boilers described in column 1 that are manufactured during the periods set out in column 4.
(2)A household oil-fired boiler complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 1 that are applicable to an oil-fired boiler as defined in section 319.
(3)The energy efficiency standards set out in column 2 of Table 2 to this section apply to commercial oil-fired boilers described in column 1 that are manufactured on or after January 1, 2025.
(4)A commercial oil-fired boiler complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix A that are applicable to an oil-fired boiler as defined in section 319.Item | Column 1 | Column 2 | Column 3 | Column 4Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Household oil-fired boilers | CSA B212 | Seasonal energy utilization efficiency ≥ 80% | On or after December 31, 1998 and before September 1, 20102 | Household oil-fired boilers that are intended for low pressure steam systems | ASHRAE 103 | Annual fuel utilization efficiency ≥ 82% | On or after September 1, 2010 and before January 15, 20212.1 | Household oil-fired boilers that are intended for low pressure steam systems | CSA P.2 for annual fuel utilization efficiency, standby power and off-mode power | Annual fuel utilization efficiency ≥ 85%Standby power ≤ 11 WOff-mode power ≤ 11 W | On or after January 15, 20213 | Household oil-fired boilers that are intended for hot water systems | ASHRAE 103 | Annual fuel utilization efficiency ≥ 84% | On or after September 1, 2010 and before September 1, 20124 | Household oil-fired boilers that are intended for hot water systems and have tankless domestic water heating coils | ASHRAE 103 | Annual fuel utilization efficiency ≥ 84% | On or after September 1, 2012 and before January 15, 20214.1 | Household oil-fired boilers that are intended for hot water systems and have tankless domestic water heating coils | CSA P.2 for annual fuel utilization efficiency, standby power and off-mode power | Annual fuel utilization efficiency ≥ 86%Standby power ≤ 11 WOff-mode power ≤ 11 W | On or after January 15, 20215 | Household oil-fired boilers that are intended for hot water systems and do not have tankless domestic water heating coils | ASHRAE 103 for annual fuel utilization efficiency | Annual fuel utilization efficiency ≥ 84%Equipped with automatic water temperature adjustment device and not operable without the device | On or after September 1, 2012 and before January 15, 20216 | Household oil-fired boilers that are intended for hot water systems and do not have tankless domestic water heating coils | CSA P.2 for annual fuel utilization efficiency, standby power and off-mode power | Annual fuel utilization efficiency ≥ 86%Equipped with automatic water temperature adjustment device and not operable without the deviceStandby power ≤ 11 WOff-mode power ≤ 11 W | On or after January 15, 2021Item | Column 1 | Column 2Energy-using Product | Energy Efficiency Standard1 | Commercial oil-fired boilers that have an input rate of ≥ 87.92 kW (300,000 Btu/h) but ≤ 732.68 kW (2,500,000 Btu/h) and are intended for hot water systems | Thermal efficiency ≥ 87%2 | Commercial oil-fired boilers that have an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and are intended for hot water systems | Combustion efficiency ≥ 88%3 | Commercial oil-fired boilers that have an input rate of ≥ 87.92 kW (300,000 Btu/h) but ≤ 732.68 kW (2,500,000 Btu/h) and are intended for low pressure steam systems | Thermal efficiency ≥ 84%4 | Commercial oil-fired boilers that have an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and are intended for low pressure steam systems | Thermal efficiency ≥ 85%
note
322Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an oil-fired boiler described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Household oil-fired boilers manufactured on or after December 31, 1998 and before September 1, 2010 | CSA B212 | (a)input rate, in kW (Btu/h); and(b)seasonal energy utilization efficiency.2 | Household oil-fired boilers manufactured on or after September 1, 2010 and before January 15, 2021 | ASHRAE 103 for information set out in paragraphs (a) to (f) | (a)type of central heating system for which product is intended;(b)maximum heat input and output nominal capacities, in kW (Btu/h);(c)power burner’s PE;(d)water pump’s BE;(e)average annual electrical energy consumption (EAE), in kWh;(f)annual fuel utilization efficiency; and(g)if product is manufactured on or after September 1, 2012,(i)information that indicates whether product has tankless domestic water heating coils, and(ii)type of automatic water temperature adjustment device product has, if any.3 | Household oil-fired boilers manufactured on or after January 15, 2021 | CSA P.2 for information set out in paragraphs (a) to (e) | (a)type of central heating system for which product is intended;(b)maximum heat input and output nominal capacities, in kW (Btu/h);(c)annual fuel utilization efficiency;(d)standby power, in W;(e)off-mode power, in W;(f)information that indicates whether product has tankless domestic water heating coils; and(g)type of automatic water temperature adjustment device product has, if any.4 | Commercial oil-fired boilers manufactured on or after January 1, 2025 | 10 C.F.R. Appendix A | (a)type of central heating system for which product is intended;(b)maximum heat input nominal capacity, in kW (Btu/h); and(c)thermal efficiency or, if product has an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and is intended for hot water systems, combustion efficiency.note
Subdivision C — Electric Boilers
323Definition of electric boiler#
In this Subdivision, electric boiler means a boiler that uses electric energy as a source of heat, is intended for application in a hot water central heating system, has an input rate of less than 88 kW (300,000 Btu/h) and is not equipped with tankless domestic water heating coils.
324Energy-using product#
(1)An electric boiler is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 325, an electric boiler is not considered to be an energy-using product unless it is manufactured on or after September 1, 2012.
325Energy efficiency standard#
The energy efficiency standard that applies to an electric boiler is that it must be equipped with an automatic water temperature adjustment device without which the boiler is not operable.
326Information#
For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of an electric boiler:
(a)its input rate, expressed in kilowatts, collected in accordance with ASHRAE 103; and
(b)the type of automatic water temperature adjustment device that it has.
Division 6 — Water Heaters
Interpretation
369Definitions#
(1)The following definitions apply in this Division.
CSA P.3-15 means the CSA standard CAN/CSA-P.3-15 entitled Testing method for measuring energy consumption and determining efficiencies of gas-fired and fuel oil-fired water heaters. (CSA P.3-15)
electric water heater means a stationary electric storage tank water heater that is intended for use on a pressurized water system and has a Vr of at least 50 L (13.21 US gallons). (chauffe-eau électrique)
first-hour rating means, in respect of an electric water heater, gas-fired storage water heater or oil-fired water heater, the measure of the maximum volume of hot water that the water heater can supply within an hour that begins when the water in the water heater is fully heated. (capacité de première heure)
gas-fired instantaneous water heater means a flow-activated water heater that uses propane or natural gas for fuel, has a Vr that is less than or equal to 38 L (10 US gallons) and has an input rate to Vr ratio of at least 309 W/L (4,000 Btu/h/US gallon). (chauffe-eau instantané au gaz)
gas-fired storage water heater means a stationary gas-heated water container that uses propane or natural gas for fuel and has a Vr of at least 76 L (20 US gallons). (chauffe-eau à réservoir alimenté au gaz)
oil-fired water heater means a water heater that uses oil for fuel and has a Vr of at least 76 L (20 US gallons). (chauffe-eau à mazout)
10 C.F.R. Appendix A means Appendix A to Subpart G, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Thermal Efficiency and Standby Loss of Gas-Fired and Oil-Fired Storage Water Heaters and Storage-Type Instantaneous Water Heaters, as amended from time to time. (appendice A 10 C.F.R.)
10 C.F.R. Appendix E means Appendix E to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Water Heaters, as amended from time to time, except for sections 5.1.1 and 5.1.2. (appendice E 10 C.F.R.)
Veff means the effective storage volume, expressed in litres, of a water heater’s storage tank, as determined in accordance with 10 C.F.R. Appendix E. (Veff)
Vr means the nominal volume, expressed in litres, of a water heater’s storage tank. (Vr)
Vs means the measured storage volume, expressed in litres, of a water heater’s storage tank. (Vs)
(2)In this Division, a reference to
(a)a “very-small-usage” draw pattern is to be read as a reference to the draw pattern set out in Table III.1 to section 5.5 of 10 C.F.R. Appendix E;
(b)a “low-usage” draw pattern is to be read as a reference to the draw pattern set out in Table III.2 to section 5.5 of 10 C.F.R. Appendix E;
(c)a “medium-usage” draw pattern is to be read as a reference to the draw pattern set out in Table III.3 to section 5.5 of 10 C.F.R. Appendix E; and
(d)a “high-usage” draw pattern is to be read as a reference to the draw pattern set out in Table III.4 to section 5.5 of 10 C.F.R. Appendix E.
note
Subdivision A — Electric Water Heaters
370Definitions#
The following definitions apply in this Subdivision.
bottom inlet means a cold water inlet, other than one with a dip tube, that enters near the bottom of the water heater’s storage tank. (entrée inférieure)
CSA C191-04 means the CSA standard CAN/CSA-C191-04 entitled Performance of Electric Storage Tank Water Heaters for Domestic Hot Water Service. (CSA C191-04)
electric water heater [Repealed, SOR/2025-110, s. 46]
10 C.F.R. Appendix B means Appendix B to Subpart G, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Standby Loss of Electric Storage Water Heaters and Storage-Type Instantaneous Water Heaters, as amended from time to time. (appendice B 10 C.F.R.)
note
370.1Type#
For the purpose of these Regulations, an electric water heater is one of the following types:
(a)household, if it has an input rate of less than or equal to 12 kW (40,982 Btu/h); or
(b)commercial, if it is has an input rate of greater than 12 kW (40,982 Btu/h).
note
371Energy-using product#
(1)An electric water heater is prescribed as an energy-using product.
(2)However, an electric water heater is not considered to be an energy-using product
(a)for the purposes of sections 4 and 5, unless it is
(i)a household electric water heater that is manufactured on or after February 3, 1995, or
(ii)a commercial electric water heater that is manufactured on or after January 1, 2020; and
(b)for the purposes of section 372, unless it is
(i)a household electric water heater that is manufactured on or after February 3, 1995,
(ii)a commercial electric water heater that is manufactured on or after January 1, 2020, or
(iii)a commercial electric water heater with a Vr that is less than or equal to 530 L (140 US gallons).
note
372Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to an electric water heater described in column 1 that is manufactured during the periods set out in column 4.
(2)An electric water heater described in column 1 complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to an electric water heater as defined in subsection 369(1).Item | Column 1 | Column 2 | Column 3 | Column 4Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Household electric water heaters that have a bottom inlet and a Vr of ≥ 50 L (13.2 US gallons) but ≤ 270 L (71.3 US gallons) | CSA C191-04 | Standby loss, in W, ≤ 40 + 0.2 Vr | On or after February 3, 1995 and before May 6, 20292 | Household electric water heaters that have a bottom inlet and a Vr of ≥ 50 L (13.2 US gallons) but < 76 L (20 US gallons) | CSA C191-04 | Standby loss, in W, ≤ 40 + 0.2 Vr | On or after May 6, 20293 | Household electric water heaters that have a bottom inlet and a Vr of > 270 L (71.3 US gallons) but ≤ 454 L (120 US gallons) | CSA C191-04 | Standby loss, in W, ≤ 0.472 Vr − 33.5 | On or after February 3, 1995 and before May 6, 20294 | Household electric water heaters that have a top inlet and a Vr of ≥ 50 L (13.2 US gallons) but ≤ 270 L (71.3 US gallons) | CSA C191-04 | Standby loss, in W, ≤ 35 + 0.2 Vr | On or after February 3, 1995 and before May 6, 20295 | Household electric water heaters that have a top inlet and a Vr of ≥ 50 L (13.2 US gallons) but < 76 L (20 US gallons) | CSA C191-04 | Standby loss, in W, ≤ 35 + 0.2 Vr | On or after May 6, 20296 | Household electric water heaters that have a top inlet and a Vr of > 270 L (71.3 US gallons) but ≤ 454 L (120 US gallons) | CSA C191-04 | Standby loss, in W, ≤ 0.472 Vr − 38.5 | On or after February 3, 1995 and before May 6, 20297 | Household electric water heaters that have a Veff of ≥ 76 L (20 US gallons) but ≤ 208 L (55 US gallons) | 10 C.F.R. Appendix E | Must have at least one of the following:(a)uniform energy factor of ≥ 0.8808 − 0.000211 Veff, if draw pattern is very-small-usage;(b)uniform energy factor of ≥ 0.9254 − 0.000079 Veff, if draw pattern is low-usage;(c)uniform energy factor ≥ 0.9307 − 0.000053 Veff, if draw pattern is medium-usage; or(d)uniform energy factor ≥ 0.9349 − 0.000026 Veff, if draw pattern is high-usage. | On or after May 6, 20298 | Household electric water heaters that have a Veff of ˃ 208 L (55 US gallons) but ≤ 454 L (120 US gallons) | 10 C.F.R. Appendix E | Uniform energy factor ≥ 0.9349 − 0.000026 Veff | On or after May 6, 20299 | Commercial electric water heaters | 10 C.F.R. Appendix B | Standby loss, in %/hr ≤ 0.3 + 102.2/Vs | On or after January 1, 2020
note
373Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an electric water heater described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Household electric water heaters manufactured on or after February 3, 1995 and before May 6, 2029 | CSA C191-04 for information set out in paragraphs (a) to (c) | (a)Vr;(b)nominal power input of upper and lower elements, in W;(c)standby loss, in W; and(d)cold water inlet configuration, namely, top inlet or bottom inlet.1.1 | Household electric water heaters with a Vr of ≥ 50 L (13.2 US gallons) but < 76 L (20 US gallons), manufactured on or after May 6, 2029 | CSA C191-04 for information set out in paragraphs (a) to (c) | (a)Vr;(b)nominal power input of upper and lower elements, in W;(c)standby loss, in W; and(d)cold water inlet configuration, namely, top inlet or bottom inlet.1.2 | Household electric water heaters with a Vr ≥ 76 L (20 US gallons) but ≤ 454 L (120 US gallons), manufactured on or after May 6, 2029 | 10 C.F.R. Appendix E | (a)Vr;(b)annual energy consumption, in kWh;(c)first-hour rating, in L;(d)Veff;(e)uniform energy factor; and(f)input rate, in kW.2 | Commercial electric water heaters with a Vr ≤ to 530 L (140 US gallons), manufactured on or after January 1, 2020 | 10 C.F.R. Appendix B | (a)Vr;(b)Vs;(c)standby loss, in %/hr; and(d)input rate, in kW.3 | Commercial electric water heaters with a Vr > 530 L (140 US gallons), manufactured on or after January 1, 2020 | 10 C.F.R. Appendix B | (a)Vr;(b)Vs; and(c)input rate, in kW.note
373.1Early compliance#
An electric water heater that is manufactured on or after May 6, 2028 and before May 6, 2029 is deemed to satisfy the requirements of sections 372 and 373 if it satisfies the requirements of those sections that would have applied to the electric water heater if it had been manufactured on or after May 6, 2029.note
Subdivision B — Gas-Fired Storage Water Heaters
374Definitions#
The following definitions apply in this Subdivision.
CSA P.3-04 means the CSA standard CAN/CSA-P.3-04 entitled Testing Method for Measuring Energy Consumption and Determining Efficiencies of Gas-Fired Storage Water Heaters. (CSA P.3-04)
gas-fired storage water heater [Repealed, SOR/2025-110, s. 50]
replacement unit means a commercial gas-fired storage water heater that is marked for replacement installations only. (unité de remplacement)
note
374.1Type#
For the purpose of these Regulations, a gas-fired storage water heater is one of the following types:
(a)household, if it has an input rate of less than or equal to 21.97 kW (75,000 Btu/h); or
(b)commercial, if it is has an input rate of greater than 21.97 kW (75,000 Btu/h).
note
375Energy-using product#
(1)A gas-fired storage water heater is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 376, a gas-fired storage water heater is not considered to be an energy-using product unless
(a)it is a household gas-fired storage water heater that is manufactured on or after February 3, 1995; or
(b)it is a commercial gas-fired storage water heater that is manufactured on or after July 1, 2023.
note
376Energy-efficiency standards — household#
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to household gas-fired storage water heaters described in column 1 that are manufactured during the periods set out in column 4.
(2)A household gas-fired storage water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 1 that are applicable to a gas-fired storage water heater as defined in subsection 369(1).
(3)The energy efficiency standards set out in column 3 of Table 2 to this section apply to commercial gas-fired storage water heaters described in column 1 that are manufactured on or after July 1, 2023.
(4)A commercial gas-fired storage water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 2 that are applicable to a gas-fired storage water heater as defined in subsection 369(1). | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Household gas-fired storage water heaters | CSA P.3-04 | Energy factor of ≥ 0.67 – 0.0005 Vr | On or after February 3, 1995 and before December 31, 20162 | Household gas-fired storage water heaters | CSA P.3-04 | Energy factor of ≥ 0.675 – 0.00039 Vr | On or after December 31, 2016 and before January 1, 20183 | Household gas-fired storage water heaters that have a first-hour rating of < 68 L (18 US gallons) | CSA P.3-04 for energy factorCSA P.3-15 for uniform energy factor | Must have at least one of the following:(a)energy factor of ≥ 0.675 – 0.00039 Vr; or(b)uniform energy factor of ≥ 0.3456 –0.00053 Vs | On or after January 1, 2018 and before May 6, 20294 | Household gas-fired storage water heaters that have a first-hour rating of ≥ 68 L (18 US gallons) but < 193 L (51 US gallons) | CSA P.3-04 for energy factorCSA P.3-15 for uniform energy factor | Must have at least one of the following:(a)energy factor of ≥ 0.675 – 0.00039 Vr; or(b)uniform energy factor of ≥ 0.5982 – 0.00050 Vs. | On or after January 1, 2018 and before May 6, 20295 | Household gas-fired storage water heaters that have a first-hour rating of ≥ 193 L (51 US gallons) but < 284 L (75 US gallons) | CSA P.3-04 for energy factorCSA P.3-15 for uniform energy factor | Must have at least one of the following:(a)energy factor of ≥ 0.675 – 0.00039 Vr; or(b)uniform energy factor of ≥ 0.6483 – 0.00045 Vs. | On or after January 1, 2018 and before May 6, 20296 | Household gas-fired storage water heaters that have a first-hour rating of ≥ 284 L (75 US gallons) | CSA P.3-04 for energy factorCSA P.3-15 for uniform energy factor | Must have at least one of the following:(a)energy factor of ≥ 0.675 – 0.00039 Vr; or(b)uniform energy factor of ≥ 0.692 – 0.00034 Vs. | On or after January 1, 2018 and before May 6, 20297 | Household gas-fired storage water heaters | 10 C.F.R. Appendix E | Must have at least one of the following:(a)uniform energy factor of ≥ 0.3456 − 0.00053 Veff, if draw pattern is very-small-usage;(b)uniform energy factor of ≥ 0.5982 − 0.00050 Veff, if draw pattern is low-usage;(c)uniform energy factor of ≥ 0.6483 − 0.00045 Veff, if draw pattern is medium-usage; or(d)uniform energy factor of ≥ 0.692 − 0.00034 Veff, if draw pattern is high-usage. | On or after May 6, 2029 | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Energy Efficiency Standard1 | Commercial gas-fired storage water heaters, other than replacement units, that have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power and limit water temperatures to < 82°C (180°F) | CSA P.3-15 | Uniform energy factor ≥ 0.8107-0.00021 Vs2 | Commercial gas-fired storage water heaters that are replacement units, have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power and limit water temperatures to < 82°C (180°F) | CSA P.3-15 | Uniform energy factor ≥ 0.6597-0.00024 Vs3 | Commercial gas-fired storage water heaters, other than replacement units, that have a Vr of > 530 L (140 US gallons) | 10 C.F.R. Appendix A | Thermal efficiency ≥ 90%4 | Commercial gas-fired storage water heaters that are replacement units and that have a Vr of > 530 L (140 US gallons) | 10 C.F.R. Appendix A | Thermal efficiency ≥ 80%5 | Commercial gas-fired storage water heaters, other than those described in items 1 and 3, that are not replacement units | 10 C.F.R. Appendix A | Thermal efficiency ≥ 90%Standby loss ≤ 0.84 (1.25 Q + 16.57√Vs)6 | Commercial gas-fired storage water heaters, other than those described in items 2 and 4, that are replacement units | 10 C.F.R. Appendix A | Thermal efficiency ≥ 80%Standby loss ≤ 1.25 Q + 16.57√Vs
note
377#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas-fired storage water heater described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Household gas-fired storage water heaters that are manufactured on or after February 3, 1995 and before January 1, 2018 | CSA P.3-04 | (a)input rate, in kW (Btu/h);(b)recovery efficiency;(c)type of fuel used;(d)annual energy consumption, in kJ (Btu);(e)first-hour rating, in L;(f)Vr; and(g)energy factor.2 | Household gas-fired storage water heaters that are manufactured on or after January 1, 2018 and before May 6, 2029 | CSA P.3-04, if a certification body has verified that the product is in compliance with the energy efficiency standard set out in any of paragraphs 3(a), 4(a), 5(a) and 6(a) of Table 1 to section 376CSA P.3-15, if a certification body has verified that the product is in compliance with the energy efficiency standard set out in any of paragraphs 3(b), 4(b), 5(b) and 6(b) of Table 1 to section 376 | (a)input rate, in kW (Btu/h);(b)recovery efficiency;(c)type of fuel used;(d)annual energy consumption, in kJ (Btu);(e)first-hour rating, in L;(f)Vr;(g)energy factor, if a certification body has verified that the product is in compliance with the energy efficiency standard set out in any of paragraphs 3(a), 4(a), 5(a) and 6(a) of Table 1 to section 376; and(h)uniform energy factor and Vs, if a certification body has verified that the product is in compliance with the energy efficiency standard set out in any of paragraphs 3(b), 4(b), 5(b) and 6(b) of Table 1 to section 376.2.1 | Household gas-fired storage water heaters that are manufactured on or after May 6, 2029 | 10 C.F.R. Appendix E | (a)input rate, in kW (Btu/h);(b)recovery efficiency;(c)type of fuel used;(d)annual energy consumption, in kJ (Btu);(e)first-hour rating, in L;(f)Vr;(g)Veff; and(h)uniform energy factor.3 | Commercial gas-fired storage water heaters that have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power, limit water temperatures to < 82°C (180°F) and are manufactured on or after July 1, 2023 | CSA P.3-15 | (a)uniform energy factor;(b)Vr;(c)Vs;(d)input rate, in kW (Btu/h);(e)type of fuel used; and(f)information that indicates whether the product is a replacement unit.4 | Commercial gas-fired storage water heaters with a Vr of > 530 L (140 US gallons) that are manufactured on or after July 1, 2023 | 10 C.F.R. Appendix A | (a)thermal efficiency;(b)Vr;(c)Vs;(d)input rate, in kW (Btu/h);(e)type of fuel used; and(f)information that indicates whether the product is a replacement unit.5 | Commercial gas-fired storage water heaters, other than those described in items 3 and 4, that are manufactured on or after July 1, 2023 | 10 C.F.R. Appendix A | (a)thermal efficiency;(b)standby loss, in W;(c)Vr;(d)Vs;(e)input rate, in kW (Btu/h);(f)type of fuel used; and(g)information that indicates whether the product is a replacement unit.note
Subdivision C — Oil-Fired Water Heaters
378Definitions#
The following definitions apply in this Subdivision.
CSA B211-00 means the CSA standard CAN/CSA-B211-00 entitled Energy Efficiency of Oil-Fired Storage Tank Water Heaters. (CSA B211-00)
oil-fired water heater [Repealed, SOR/2025-110, s. 53]
note
378.1Type#
For the purpose of these Regulations, an oil-fired water heater is one of the following types:
(a)household, if it has an input rate of less than or equal to 30.5 kW (105,000 Btu/h); or
(b)commercial, if it is has an input rate of greater than 30.5 kW (105,000 Btu/h).
note
379Energy-using product#
(1)An oil-fired water heater is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 380, an oil-fired water heater is not considered to be an energy-using product unless
(a)it is a household oil-fired water heater that is manufactured on or after February 3, 1995; or
(b)it is a commercial oil-fired water heater that is manufactured on or after January 1, 2020.
note
380Energy efficiency standards — household#
(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to household oil-fired water heaters described in column 1 that are manufactured during the period set out in column 4.
(2)A household oil-fired water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 1 that are applicable to an oil-fired water heateras defined in subsection 369(1).
(3)The energy efficiency standards set out in column 2 of Table 2 to this section apply to commercial oil-fired water heaters described in column 1 that are manufactured on or after January 1, 2020.
(4)A commercial oil-fired water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 2 that are applicable to an oil-fired water heater as defined in subsection 369(1). | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Household oil-fired water heaters | CSA B211-00 | Energy factor of ≥ 0.59 – 0.0005 Vr | On or after February 3, 1995 and before December 31, 20162 | Household oil-fired water heaters | CSA B211-00 | Energy factor of ≥ 0.68 – 0.0005 Vr | On or after December 31, 2016 and before January 1, 20183 | Household oil-fired water heaters that have a first-hour rating of < 68 L (18 US gallons) | CSA B211-00 for energy factorCSA P.3-15 for uniform energy factor | Must have at least one of the following:(a)energy factor of ≥ 0.68 – 0.0005 Vr; or(b)uniform energy factor of ≥ 0.2509 – 0.00032 Vs. | On or after January 1, 2018 and before May 6, 20294 | Household oil-fired water heaters that have a first-hour rating of ≥ 68 L (18 US gallons) but < 193 L (51 US gallons) | CSA B211-00 for energy factorCSA P.3-15 for uniform energy factor | Must have at least one of the following:(a)energy factor of ≥ 0.68 – 0.0005 Vr; or(b)uniform energy factor of ≥ 0.5330 – 0.00042 Vs. | On or after January 1, 2018 and before May 6, 20295 | Household oil-fired water heaters that have a first-hour rating of ≥ 193 L (51 US gallons) but < 284 L (75 US gallons) | CSA B211-00 for energy factorCSA P.3-15 for uniform energy factor | Must have at least one of the following:(a)energy factor of ≥ 0.68 – 0.0005 Vr; or(b)uniform energy factor of ≥ 0.6078 – 0.00042 Vs. | On or after January 1, 2018 and before May 6, 20296 | Household oil-fired water heaters that have a first-hour rating of ≥ 284 L (75 US gallons) | CSA B211-00 for energy factorCSA P.3-15 for uniform energy factor | Must have at least one of the following:(a)energy factor of ≥ 0.68 – 0.0005 Vr; or(b)uniform energy factor of ≥ 0.6815 – 0.00037 Vs. | On or after January 1, 2018 and before May 6, 20297 | Household oil-fired water heaters | 10 C.F.R. Appendix E | Must have at least one of the following:(a)uniform energy factor of ≥ 0.2509 − 0.00032 Veff, if draw pattern is very-small-usage;(b)uniform energy factor ≥ 0.5330 − 0.00042 Veff, if draw pattern is low-usage;(c)uniform energy factor ≥ 0.6078 − 0.00042 Veff, if draw pattern is medium-usage; or(d)uniform energy factor ≥ 0.6815 − 0.00037 Veff, if draw pattern is high-usage. | On or after May 6, 2029 | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Energy Efficiency Standard1 | Commercial oil-fired water heaters that have an input rate of > 30.5 kW (105,000 Btu/h) but ≤ 40.99 kW (140,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power, limit water temperatures to < 82°C (180°F) and are manufactured on or after January 1, 2020 | CSA P.3-15 | Uniform energy factor ≥ 0.6740 - 0.00035 Vs2 | Commercial oil-fired water heaters with a Vr of > 530 L (140 US gallons) that are manufactured on or after January 1, 2020 | 10 C.F.R. Appendix A | Thermal efficiency ≥ 80%3 | Commercial oil-fired water heaters, other than those described in items 1 and 2, that are manufactured on or after January 1, 2020 | 10 C.F.R. Appendix A | Thermal efficiency ≥ 80%Standby loss ≤ 1.25 Q + 16.57√Vs
note
381Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an oil-fired water heater described in column 1.Item | Column 1 | Column 2 | Column 3Energy-using Product | Testing Standard | Information1 | Household oil-fired water heaters that are manufactured on or after February 3, 1995 and before January 1, 2018 | CSA B211-00 | (a)input rate, in kW (Btu/h);(b)recovery efficiency;(c)annual energy consumption, in kJ (Btu);(d)first-hour rating, in L;(e)Vr; and(f)energy factor.2 | Household oil-fired water heaters that are manufactured on or after January 1, 2018 and before May 6, 2029 | CSA B211-00, if a certification body has verified that product is in compliance with the energy efficiency standard set out in any of paragraphs 3(a), 4(a), 5(a) and 6(a) of Table 1 to section 380CSA P.3-15, if a certification body has verified that product is in compliance with the energy efficiency standard set out in any of paragraphs 3(b), 4(b), 5(b) and 6(b) of Table 1 to section 380 | (a)input rate, kW (Btu/h);(b)recovery efficiency;(c)annual energy consumption, in kJ (Btu);(d)first-hour rating, in L;(e)Vr;(f)energy factor; and(g)uniform energy factor and Vs, if a certification body has verified that product is in compliance with the energy efficiency standard set out in any of paragraphs 3(b), 4(b), 5(b) and 6(b) of Table 1 to section 380.2.1 | Household oil-fired water heaters that are manufactured on or after May 6, 2029 | 10 C.F.R. Appendix E | (a)input rate, in kW (Btu/h);(b)recovery efficiency;(c)annual energy consumption, in kJ (Btu);(d)first-hour rating, in L;(e)Vr;(f)Veff; and(g)uniform energy factor.3 | Commercial oil-fired water heaters that have an input rate of > 30.5 kW (105,000 Btu/h) but ≤ 40.99 kW (140,000 Btu/h), have a Vr of ≤ 454 L (120 US gallons), use single-phase power, limit water temperatures to < 82°C (180°F) and are manufactured on or after January 1, 2020 | CSA P.3-15 | (a)input rate, in kW (Btu/h);b)uniform energy factor;(c)Vr; and(d)Vs.4 | Commercial oil-fired water heaters with a Vr of > 530 L (140 US gallons) that are manufactured on or after January 1, 2020 | 10 C.F.R. Appendix A | (a)input rate, in kW (Btu/h);(b)thermal efficiency;(c)Vr; and(d)Vs.5 | Commercial oil-fired water heaters, other than those described in items 3 and 4, that are manufactured on or after January 1, 2020 | 10 C.F.R. Appendix A | (a)input rate, in kW (Btu/h);(b)thermal efficiency;(c)Vr;(d)Vs; and(e)standby loss, in W.note
Subdivision D — Gas-Fired Instantaneous Water Heaters
382Definitions#
The following definitions apply in this Subdivision.
gas-fired instantaneous water heater [Repealed, SOR/2025-110, s. 56]
maximum flow rate means, in respect of a gas-fired instantaneous water heater, the maximum litres per minute (gallons per minute) of hot water that can be supplied by the water heater while operating in a steady state and maintaining a nominal temperature rise of 37.3°C (67°F). (débit maximal)
10 C.F.R. Appendix C means Appendix C to the Subpart G, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Thermal Efficiency and Standby Loss of Gas-Fired and Oil-Fired Instantaneous Water Heaters and Hot Water Supply Boilers (Other Than Storage-Type Instantaneous Water Heaters), as amended from time to time. (appendice C 10 C.F.R.)
note
383Type#
For the purpose of these Regulations, a gas-fired instantaneous water heater is one of the following types:
(a)household, if it has an input rate of less than 58.56 kW (200,000 Btu/h), has a Vr of no greater than 7.6 L (2 US gallons) and is designed to provide hot water at a temperature no greater than 82°C (180°F); or
(b)commercial, if it is not described in paragraph (a).
note
384Energy-using product#
(1)A gas-fired instantaneous water heater is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 385, a gas-fired instantaneous water heater is not considered to be an energy-using product unless
(a)it is a household gas-fired instantaneous water heater that is manufactured on or after January 1, 2020; or
(b)it is a commercial gas-fired instantaneous water heater that is manufactured on or after July 1, 2023.
note
385Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to gas-fired instantaneous water heaters described in column 1 that are manufactured during the period set out in column 4.
(2)A gas-fired instantaneous water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a gas-fired instantaneous water heater as defined in subsection 369(1).Item | Column 1 | Column 2 | Column 3 | Column 4Energy-using Product | Testing Standard | Energy Efficiency Standard | Manufacturing Period1 | Household gas-fired instantaneous water heaters that have a maximum flow rate of < 6.4 L/min | CSA P.3-15 | Uniform energy factor ≥ 0.86 | On or after January 1, 2020 and before May 6, 20292 | Household gas-fired instantaneous water heaters that have a maximum flow rate of ≥ 6.4 L/min | CSA P.3-15 | Uniform energy factor ≥ 0.87 | On or after January 1, 2020 and before May 6, 20293 | Household gas-fired instantaneous water heaters that have a maximum flow rate of < 6.4 L/min | 10 C.F.R. Appendix E | Uniform energy factor ≥ 0.86 | On or after May 6, 20294 | Household gas-fired instantaneous water heaters that have a maximum flow rate of ≥ 6.4 L/min | 10 C.F.R. Appendix E | Uniform energy factor ≥ 0.87 | On or after May 6, 20295 | Commercial gas-fired instantaneous water heaters | 10 C.F.R. Appendix C | Thermal efficiency ≥ 94% | On or after July 1, 2023
note
386Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas-fired instantaneous water heater described in column 1.Item | Column 1 | Column 2 | Column 3Energy-using Product | Testing Standard | Information1 | Household gas-fired instantaneous water heaters manufactured on or after January 1, 2020 and before May 6, 2029 | CSA P.3-15 | (a)uniform energy factor;(b)Vr;(c)the type of fuel used;(d)input rate, in kW (Btu/h); and(e)maximum flow rate.1.1 | Household gas-fired instantaneous water heaters manufactured on or after May 6, 2029 | 10 C.F.R. Appendix E | (a)Vr;(b)Veff;(c)type of fuel used;(d)input rate, in kW (Btu/h);(e)maximum flow rate; and(f)uniform energy factor.2 | Commercial gas-fired instantaneous water heaters manufactured on or after July 1, 2023 | 10 C.F.R. Appendix C | (a)thermal efficiency;(b)Vr;(c)the type of fuel used;(d)input rate, in kW (Btu/h); and(e)maximum flow rate.note
Division 7 — Lamps and Lamp Ballasts
Interpretation
424Definitions#
The following definitions apply in this Division.
ANSI C78.20 [Repealed, SOR/2025-110, s. 60]
ANSI C78.79 means the ANSI standard ANSI C78.79-2014 entitled American National Standard for Electric Lamps — Nomenclature for Envelope Shapes Intended for Use with Electric Lamps. (ANSI C78.79)
ANSI C79.1 [Repealed, SOR/2018-201, s. 42]
ANSI C81.61 means the ANSI standard ANSI C81.61-2016 entitled American National Standard for Electrical Lamp Bases — Specifications for Bases (Caps) for Electric Lamps. (ANSI C81.61)
appliance lamp [Repealed, SOR/2025-110, s. 60]
coloured lamp [Repealed, SOR/2025-110, s. 60]
colour rendering index means the measured degree of colour shift that objects undergo when they are illuminated by a light source as compared with the colour of those same objects when they are illuminated by a reference source of comparable colour temperature. (indice de rendu des couleurs)
former Regulations means these Regulations as they read immediately before the day on which subsection 1(2) of the Regulations Amending the Energy Efficiency Regulations, 2016 (Amendment 18) comes into force. (règlement antérieur)
IES Handbook means the IES publication entitled Lighting Handbook, 9th edition. (Manuel IES)
IES LM16 means the IES standard IES LM-16-1993 entitled Practical Guide to Colorimetry of Light Sources. (IES LM16)
IES LM45 [Repealed, SOR/2025-110, s. 60]
IES LM49 [Repealed, SOR/2025-110, s. 60]
IES LM65 [Repealed, SOR/2025-110, s. 60]
incandescent reflector lamp [Repealed, SOR/2025-110, s. 60]
infrared lamp [Repealed, SOR/2025-110, s. 60]
lamp efficacy means the number of lumens per watt determined by
(a)dividing a lamp’s luminous flux by its power, measured under equilibrium conditions at the time of determining the luminous flux; and
(b)in the case of a general service incandescent reflector lamp, rounding the number calculated under paragraph (a) to the nearest half number. (efficacité lumineuse)
modified spectrum lamp [Repealed, SOR/2025-110, s. 60]
rough service lamp [Repealed, SOR/2025-110, s. 60]
shatter-resistant lamp [Repealed, SOR/2025-110, s. 60]
silver bowl lamp [Repealed, SOR/2025-110, s. 60]
submersible lamp [Repealed, SOR/2025-110, s. 60]
vibration service lamp [Repealed, SOR/2025-110, s. 60]
note
Labelling
425Label required#
(1)Every general service lamp that is manufactured on or after January 1, 2027 and that, for the purpose of sale or lease, is shipped from one province to another or imported into Canada must be labelled in accordance with sections 426 to 429.
(2)Sections 425 to 429 of the former Regulations continue to apply in respect of a lamp that is referred to in section 425 of the former Regulations that is manufactured before January 1, 2027.
note
426Information on principal display panel#
(1)The principal display panel of the product’s package must display the following information in the following order:
(5)If the product is a three-way lamp, the information required by paragraphs (1)(a) to (c) must be displayed for each level of the lamp’s operation.
(6)If the product has a variable correlated colour temperature, the information required by paragraph (1)(e) must be displayed for the lamp’s range of operation or for each level of its operation.
note
427Model number#
The lamp model number must be indicated on both the product packaging and the lamp itself.note
428Design voltage other than 120 V#
(1)If the design voltage of the product is other than 120 V, the information required by section 426 may correspond to
(a)a voltage of 120 V, followed by the words “at 120 volts” and “à 120 volts”; or
(b)the design voltage, followed by the words, “at [design voltage] volts” and “à [tension spécifique]”.
(2)If the information corresponds to the design voltage,
(a)the following statements must be displayed on the principal display panel:“This product is designed for [design voltage] volts. When used on the normal line voltage of 120 volts, the light output and energy efficiency are noticeably reduced. See [appropriate panel] panel for 120-volt rating.”« Ce produit a été conçu en fonction d’une tension de [tension spécifique] volts. S’il est employé à la tension normale de 120 volts, son flux lumineux et son efficacité énergétique s’en trouveront considérablement réduits. Voir le panneau [panneau en cause] pour les renseignements correspondant à une tension de 120 volts. »;
(c)the design voltage must be displayed on every panel that displays the information required by section 426, other than the panel on which the information required by paragraph (b) is displayed.
note
429Multiple lamps in common package#
If more than one type of lamp is included in a common package and their characteristics are not uniform, the principal display panel of the common package must display the following information for each type of lamp:
(a)its design voltage; and
(b)the information required by section 426, which must be in the size and font specified in that section.
Subdivision A — [Repealed, SOR/2025-110, s. 64]
Subdivision B — General Service Lamps
433Definitions#
(1)The following definitions apply in this Subdivision.
10 C.F.R. §430.23(gg) means paragraph 430.23(gg) of Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.23(gg))
black light lamp means an ultraviolet lamp that has its highest radiant power peaks in the UV-A band (315 to 400 nm) of the electromagnetic spectrum. (lampe à lumière noire)
CFL means a compact fluorescent lamp that has an integrated or non-integrated single base. It does not include circline or U-shaped lamps. (LFC)
coloured lamp means a lamp that is designed and marketed as a coloured lamp and that, in each of its modes of operation, has,
(a)if it is an incandescent lamp,
(i)a colour rendering index of less than 50, as determined in accordance with CIE 13.3, or
(ii)a correlated colour temperature of less than 2500 K or greater than 4600 K; and
(b)if it is a lamp other than an incandescent lamp,
(i)a colour rendering index of less than 40, as determined in accordance with CIE 13.3, or
(ii)a correlated colour temperature of less than 2500 K or greater than 7000 K. (lampe colorée)
fluorescent lamp means a low-pressure mercury, electric-discharge source in which a fluorescing coating transforms some of the ultraviolet energy generated by the mercury discharge into light. (lampe fluorescente)
general lighting application means lighting that provides an interior or exterior area with overall illumination. (source d’éclairage général)
general service incandescent lamp means a standard incandescent lamp, including a halogen type lamp, that is intended for general lighting applications and that
(a)has a medium screw base;
(c)is capable of being operated at a voltage that is at least partially within the range from 110 V to 130 V.
It does not include an appliance lamp, black light lamp, bug lamp, coloured lamp, G-shape lamp — as described in ANSI C78.79 — with a diameter of 127 mm (5 in) or more, infrared lamp, left-hand thread lamp, marine lamp, marine signal service lamp, mine service lamp, plant lamp, R20 short lamp, sign service lamp, silver bowl lamp, showcase lamp or traffic signal lamp. (lampe à incandescence standard)
general service incandescent reflector lamp means a lamp in which light is produced by a filament heated to incandescence by an electric current and that
(a)contains an inner reflective coating on the outer bulb to direct the light;
(b)has an R, PAR, ER, BR, BPAR or similar bulb shape with an E26 medium screw base;
(c)has a rated voltage or voltage range that lies at least partially in the range of 115 V to 130 V;
(d)has a diameter exceeding 57 mm (2.25 inches); and
(e)has a rated wattage of 40 W or higher.
It does not include a coloured lamp, rough service lamp, vibration service lamp or R20 short lamp. (lampe-réflecteur à incandescence standard)
general service lamp means, subject to subsection (2), an electrical device that is used in general lighting applications and that
(a)has a base that complies with ANSI C81.61;
(b)is able to operate, in the case of an integrated lamp, at
(i)a voltage of 12 V or 24V,
(ii)a voltage ranging from 100 V to 130 V,
(iii)a voltage ranging from 220 V to 240 V, or
(iv)a voltage of 277 V or 347 V;
(c)is able to operate at any voltage, in the case of a non-integrated lamp; and
(d)has an initial lumen output of
(i)at least 310 lm but no more than 3300 lm, or
(ii)in the case of a modified spectrum incandescent lamp, at least 232 lm but no more than 3300 lm.
general service LED lamp means an integrated or non-integrated lamp that is designed for use in general lighting applications and that uses light-emitting diodes as the primary source of light. (lampe à DEL standard)
general service OLED lamp means an integrated or non-integrated lamp that is designed for use in general lighting applications and that uses organic light-emitting diodes as the primary source of light. (lampe à DELO standard)
infrared lamp means a lamp that
(a)has its highest radiant power peaks in the infrared region of the electromagnetic spectrum (770 nm to 1 mm);
(b)has a rated wattage of 125 W or greater; and
(c)provides heat as its primary purpose. (lampe infrarouge)
integrated, in relation to a lamp, means containing all of the components necessary for the starting and stable operation of the lamp, not including any replaceable or interchangeable parts, and being connected directly to a branch circuit through a base and corresponding socket that comply with ANSI standards. (intégrée)
LED downlight retrofit kit means a retrofit kit that is designed and marketed to install into an existing downlight for the purpose of replacing the existing light source and related electrical components with a light source that uses light-emitting diodes as the primary source of light. It includes a kit that employs an ANSI standard lamp base, either integrated or connected to the downlight retrofit by wire leads. (ensemble de conversion à DEL)
left-hand thread lamp means a lamp with the direction of threads on the lamp base oriented in the left-hand direction. (lampe à filetage à gauche)
modified spectrum incandescent lamp means an incandescent lamp that, when operated at the rated voltage and wattage of the lamp, has a colour point on the CIE 1931 chromaticity diagram, figure 2, page 3 of IES LM16 that lies
(a)below the black-body locus; and
It does not include a coloured lamp. (lampe à incandescence à spectre modifié)
R20 short lamp means a lamp that is an R20 incandescent reflector lamp that is designed, labelled and marketed for pool and spa applications and that
(a)has a rated wattage of 100 W; and
(b)has a maximum overall length of 92 mm (3.625 inches). (lampe courte R20)
reflector lamp means a lamp that has an R, PAR, BPAR, BR, ER, MR or similar bulb shape, as described in ANSI C78.79, and that is used to provide directional light. (lampe-réflecteur)
rough service lamp means a lamp that is marketed as a rough service lamp and has any of the following filament constructions, as illustrated in figure 6.12 of the IES Handbook:
(a)a C-7A or C-11 filament construction with at least five supports exclusive of lead wires;
(b)a C-17 filament construction with eight supports exclusive of lead wires;
(c)a C-22 filament construction with 16 supports exclusive of lead wires. (lampe à construction renforcée)
shatter-resistant lamp means a lamp that is designed and marketed as a shatter-resistant, shatter-proof or shatter-protected lamp and has an external silicone, polytetrafluoroethylene or similar coating applied to it for the purpose of resisting breakage and preventing glass from reaching its environment in the event of breakage. (lampe résistante à l’éclatement)
showcase lamp means a lamp that is designed and marketed for use in a showcase, has a T-shape, as described in ANSI C78.79, and has a maximum rated wattage of 75 W. (lampe de vitrine)
sign service lamp means a vacuum type or gas-filled lamp that is designed and marketed for use in a sign and that
(a)has sufficiently low bulb temperature to permit exposed outdoor use on high-speed flashing circuits; and
(b)has a maximum rated wattage of 15 W. (lampe d’enseigne)
silver bowl lamp means a lamp that is marketed as a silver bowl lamp and that has an opaque reflective coating that is applied directly to a part of the bulb surface so that the light is reflected toward the lamp base. (lampe à calotte argentée)
specialty MR lamp means a lamp that is designed and marketed for a specialty application and that has an MR shape, as described in ANSI C78.79, a diameter of less than or equal to 57 mm (2.25 inches) and a lifetime of 300 hours or less. (lampe MR spécialisée)
TSD D7SB001 means the technical standards document D7SB001 published by the Minister and entitled General Service Lamps: Energy Efficiency Standards for General Service Lamps. (DNT D7SB001)
vibration service lamp means a lamp that is sold at retail in packages of one or two, is designed and marketed as a vibration service lamp and
(a)has a maximum nominal power of 60 W; and
(b)has a C-5, C-7A or C-9 filament construction, as illustrated in figure 6.12 of the IES Handbook, or a similar configuration. (lampe antivibrations)
(2)The definition general service lamp in subsection (1) does not include
(a)a light fixture;
(b)an LED downlight retrofit kit;
(c)an appliance lamp;
(d)a black light lamp;
(e)a bug lamp;
(f)a coloured lamp;
(g)a G-shape lamp, as described in ANSI C78.79, with a diameter of 127 mm (5 inches) or more;
(h)a high-intensity discharge lamp;
(i)an infrared lamp;
(j)a J-, JC-, JCD-, JCS-, JCV-, JCX-, JD-, JS- or JT-shape lamp that does not have an Edison screw base as defined in ANSI C81.61;
(k)a lamp that has a wedge base or pre-focus base;
(l)a left-hand thread lamp;
(m)a marine lamp;
(n)a marine signal service lamp;
(o)a mine service lamp;
(p)an MR-shape lamp that has a first number symbol equal to 16 (diameter equal to 51 mm (2 inches)), as described in ANSI C78.79, operates at 12 V and has a lumen output greater than or equal to 800 lm;
(q)a fluorescent lamp other than a CFL;
(r)a plant lamp;
(s)an R20 short lamp;
(t)a reflector lamp that
(i)has a first number symbol less than 16 (diameter less than 51 mm (2 inches)), as described in ANSI C78.79, and
(ii)does not have an E26/E24, E26d, E26/50x39, E26/53x39, E29/28, E29/53x39, E39, E39d, EP39 or EX39 base;
(u)an S-shape or G-shape lamp that has a first number symbol less than or equal to 12.5 (diameter less than or equal to 40 mm (1.5625 inches)), as described in ANSI C78.79;
(v)a sign service lamp;
(w)a silver bowl lamp;
(x)a showcase lamp;
(y)a specialty MR lamp;
(z)a T-shape lamp, other than a CFL, that
(i)has a first number symbol less than or equal to 8 (diameter less than or equal to 25 mm (1 inch)), as described in ANSI C78.79, and
(ii)has a nominal overall length less than 305 mm (12 inches); or
(z.1)a traffic signal lamp.
note
434Energy-using product#
(1)A general service lamp is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 435 and 436, a general service lamp is not considered to be an energy-using product if
(a)in the case of a general service incandescent lamp or general service incandescent reflector lamp, it is manufactured before January 1, 2026; or
(b)in any other case, it is manufactured before January 1, 2027.
note
434.1Application of former Regulations#
(1)Sections 4, 5, 424 and 430 to 444 of the former Regulations continue to apply in respect of a lamp that is
(a)a CFL, as defined in section 430 of the former Regulations, manufactured before January 1, 2027;
(b)a general service lamp, as defined in subsection 433(1) of the former Regulations, manufactured before January 1, 2026;
(c)a modified spectrum incandescent lamp, as defined in section 437 of the former Regulations, manufactured before January 1, 2026; or
(d)a general service incandescent reflector lamp, as defined in section 441 of the former Regulations, manufactured before January 1, 2026.
(2)Subsection (1) does not apply in respect of a lamp that is deemed, under section 436.1, to satisfy the requirements of sections 4, 5, 435 and 436.
note
435Energy efficiency standards#
(1)The energy efficiency standards set out in TSD D7SB001 apply to general service lamps.
(2)A general service lamp complies with the energy efficiency standard if it meets that standard when tested in accordance with the applicable testing procedures established by 10 C.F.R. §430.23(gg).
note
436Information#
For the purposes of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a general service lamp:
(a)a description of the lamp, collected in accordance with ANSI C78.79; and
(b)the following information, collected in accordance with 10 C.F.R. §430.23(gg):
(i)the rated lumen output or, in the case of a three-way lamp, the three rated lumen outputs, in lumens,
(ii)the rated power or, in the case of a three-way lamp, the three values for rated power, in watts,
(iii)the rated lamp efficacy, in lm/W,
(iv)the rated life, in hours,
(v)the rated correlated colour temperature or range of correlated colour temperatures, in degrees Kelvin, and
(vi)the rated colour rendering index.
note
436.1Early compliance#
A general service lamp is deemed to satisfy the requirements of sections 4, 5, 435 and 436 if
(a)in the case of a general service incandescent lamp or general service incandescent reflector lamp, it was manufactured on or after January 1, 2024 and before January 1, 2026 and satisfies the requirements of sections 4, 5, 435 and 436 that would have applied to the lamp if it had been manufactured on or after January 1, 2026; and
note
Subdivision C — Modified Spectrum Incandescent Lamps
Subdivision D — [Repealed, SOR/2025-110, s. 69]
Subdivision E — General Service Fluorescent Lamps
445Definitions#
The following definitions apply in this Subdivision.
10 C.F.R. Appendix R means Appendix R to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring Average Lamp Efficacy (LE), Color Rendering Index (CRI), and Correlated Color Temperature (CCT) of Electric Lamps, as amended from time to time. (appendice R 10 C.F.R.)
10 C.F.R. §430.32(n)(4) means the table to paragraph 430.32(n)(4) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(n)(4))
ANSI C78.81 means the ANSI standard ANSI C78.81-2010 entitled American National Standard for Electric Lamps Double-Capped Fluorescent Lamps — Dimensional and Electrical Characteristics. (ANSI C78.81)
ANSI C78.901 means the ANSI standard ANSI C78.901-2005 entitled American National Standard for Electric Lamps Single — Based Fluorescent Lamps — Dimensional and Electrical Characteristics. (ANSI C78.901)
CSA C819-11 means the CSA standard CAN/CSA-C819-11 entitled Performance of general service fluorescent lamps. (CSA C819-11)
CSA C819-16 means the CSA standard CAN/CSA-C819-16 entitled Performance of General Service Fluorescent Lamps. (CSA C819-16)
CSA C819-95 [Repealed, SOR/2018-201, s. 44]
cold temperature fluorescent lamp means a fluorescent lamp that is marketed for outdoor or cold temperature use and that is designed to start at temperatures as low as –29°C (–20°F) when used with a ballast that conforms to the requirements of ANSI C78.81 and ANSI C78.901. (lampe fluorescente pour basses températures)
coloured fluorescent lamp means a fluorescent lamp that has
(a)a colour rendering index of less than 40, as determined in accordance with CIE 13.3; or
(b)a correlated colour temperature of less than 2 500 K or more than 7 000 K, as determined in accordance with the IES standard IES LM-9-09 entitled IES Approved Method for the Electrical and Photometric Measurement of Fluorescent Lamps. (lampe fluorescente colorée)
general service fluorescent lamp means a fluorescent lamp that
(g)is a physical and electrical equivalent of a lamp described in any of paragraphs (a) to (f).
(h)a fluorescent lamp that is marketed as a plant lamp;
(k)a fluorescent lamp that is designed to be impact-resistant;
(l)a reflectorized or aperture fluorescent lamp;
(m)a fluorescent lamp that is designed for use in reprographic equipment;
(n)a fluorescent lamp that is primarily designed to produce ultraviolet radiation; or
(o)a fluorescent lamp that has a colour rendering index of at least 87. (lampe fluorescente standard)
It does not include any of the following:
note
446Energy-using product#
(1)A general service fluorescent lamp is prescribed as an energy-using product.
(2)However, for the purpose of section 4, a general service fluorescent lamp is not considered to be an energy-using product unless it is manufactured on or after December 31, 1996.
447Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to general service fluorescent lamps that are manufactured during the periods set out in column 3.
(2)A general service fluorescent lamp complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a general service fluorescent lamp as defined in section 445. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C819-11 | CSA C819-11, Table 1 | On or after December 31, 1996 and before January 26, 20182 | CSA C819-16 or 10 C.F.R. Appendix R | CSA C819-16, Table 1 or average lamp efficacy × 1.011 > minimum average lamp efficacy for the product in 10 C.F.R. §430.32(n)(4) | On or after January 26, 2018
note
448Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a general service fluorescent lamp:
(a)its nominal power, expressed in watts;
(b)its shape;
(c)its nominal overall length;
(d)its diameter;
(e)its base type;
(f)its abbreviation under the designation system in ANSI C78.81, Annex A, and ANSI C78.901, Annex B;
(g)its correlated colour temperature;
(h)its average colour rendering index; and
(i)the average lamp efficacy.
(2)The information must be collected in accordance with one of the following standards:
(a)CSA C819-11, if the product was manufactured on or after December 31, 1996 and before January 26, 2018; or
(b)CSA C819-16 or 10 C.F.R. Appendix R, if the product is manufactured on or after January 26, 2018.
note
Subdivision F — Fluorescent Lamp Ballasts
449Definitions#
(1)The following definitions apply in this Subdivision.
CSA C654-10 means the CSA standard CAN/CSA-C654-10 entitled Fluorescent lamp ballast efficacy measurements. (CSA C654-10)
CSA C654-14 means the CSA standard CAN/CSA-C654-14 entitled Fluorescent lamp ballast efficacy measurements. (CSA C654-14)
fluorescent lamp ballast means a ballast that is
(a)designed to start and operate fluorescent lamps by
(i)providing the necessary voltage and current,
(ii)limiting the current during normal operation, and
(iii)if necessary to facilitate lamp operation, providing cathode heating;
(b)designed for a nominal voltage of at least 120 V but not more than 347 V; and
(c)described in Table 1A of CSA C654-14.
(d)a ballast — other than a T12 dimming ballast — that, by means of an integrated dimming capability, is designed to reduce the output of a fluorescent lamp by 50% or more;
It does not include any of the following:
high-frequency means, in respect of a fluorescent lamp ballast, that the ballast operates the lamp at a frequency of 10 kHz or more. (à haute fréquence)
low-frequency means, in respect of a fluorescent lamp ballast, that the ballast operates at a supply frequency of 50 to 60 Hz and operates the lamp at the same frequency as the supply. (à basse fréquence)
10 C.F.R. §430.32(m)(2)(ii)(B) means paragraph 430.32(m)(2)(ii)(B) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(m)(2)(ii)(B))
10 C.F.R. Appendix Q means Appendix Q to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Fluorescent Lamp Ballasts, as amended from time to time. (appendice Q 10 C.F.R.)
T12 dimming ballast means a fluorescent lamp ballast that
(a)is designed for a nominal voltage of at least 120 V but not more than 277 V;
(b)by means of an integrated dimming capability, is designed to reduce the output of a T12 fluorescent lamp by 50% or more; and
(c)is designed to operate one F34T12 fluorescent lamp or two F34T12, F96T12ES or F96T12HO ES fluorescent lamps. (ballast de gradation T12)
(2)Despite subsection 1(3), a reference in this Subdivision to Table 1A of CSA C654-14 is a reference to that table as it read on the day on which the standard was published.
note
450Energy-using product#
(1)A fluorescent lamp ballast is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 451, a fluorescent lamp ballast is not considered to be an energy-using product if
(a)it was manufactured before February 3, 1995; or
(i)is a T12 dimming ballast,
(ii)is designed to operate a fluorescent lamp other than an F32T8, F34T12, F40T10 or F40T12 rapid-start fluorescent lamp or an F96T12ES, F96T12IS, F96T12HO or F96T12HO ES fluorescent lamp, or
(iii)is designed to be used in an outdoor sign and to operate two F96T12HO fluorescent lamps in ambient temperatures at or below –28.9°C.
note
451Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to fluorescent lamp ballasts described in column 1 that are manufactured during the periods described in column 4.
(2)A fluorescent lamp ballast complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a fluorescent lamp ballast as defined in section 449. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Fluorescent lamp ballasts | CSA C654-10 | CSA C654-10, clause 4 for power factorCSA C654-10, Table 2 for ballast efficacy factor | On or after February 3, 1995 and before November 14, 20142 | Fluorescent lamp ballasts, other than T12 dimming ballasts | CSA C654-14 or 10 C.F.R. Appendix Q | CSA C654-14, clause 4 for power factorCSA C654-14, clause 5.2 for ballast luminous efficiency | On or after November 14, 20143 | T12 dimming ballasts that are low-frequency and designed to operate one F34T12 lamp | CSA C654-14 or 10 C.F.R. Appendix Q | CSA C654-14, clause 4 for power factorMust have ballast luminous efficiency that is ≥ that specified for ballast in table to 10 C.F.R. §430.32(m)(2)(ii)(B) | On or after November 14, 20144 | T12 dimming ballasts that are high-frequency and designed to operate one F34T12 lamp | CSA C654-14 or 10 C.F.R. Appendix Q | CSA C654-14, clause 4 for power factorMust have ballast luminous efficiency that is ≥ that specified for ballast in table to 10 C.F.R. §430.32(m)(2)(ii)(B) | On or after November 14, 20145 | T12 dimming ballasts that are low-frequency and designed to operate two F34T12 lamps | CSA C654-14 or 10 C.F.R. Appendix Q | CSA C654-14, clause 4 for power factorMust have ballast luminous efficiency that is ≥ that specified for ballast in table to 10 C.F.R. §430.32(m)(2)(ii)(B) | On or after November 14, 20146 | T12 dimming ballasts that are high-frequency and designed to operate two F34T12 lamps | CSA C654-14 or 10 C.F.R. Appendix Q | CSA C654-14, clause 4 for power factorMust have ballast luminous efficiency that is ≥ that specified for ballast in table to 10 C.F.R. §430.32(m)(2)(ii)(B) | On or after November 14, 20147 | T12 dimming ballasts that are low-frequency and designed to operate two F96T12/ES lamps | CSA C654-14 or 10 C.F.R. Appendix Q | CSA C654-14, clause 4 for power factorMust have ballast luminous efficiency that is ≥ that specified for ballast in table to 10 C.F.R. §430.32(m)(2)(ii)(B) | On or after November 14, 20148 | T12 dimming ballasts that are high-frequency and designed to operate two F96T12/ES lamps | CSA C654-14 or 10 C.F.R. Appendix Q | CSA C654-14, clause 4 for power factorMust have ballast luminous efficiency that is ≥ that specified for ballast in table to 10 C.F.R. §430.32(m)(2)(ii)(B) | On or after November 14, 20149 | T12 dimming ballasts that are low-frequency and designed to operate two F96T12HO/ES lamps | CSA C654-14 or 10 C.F.R. Appendix Q | CSA C654-14, clause 4 for power factorMust have ballast luminous efficiency that is ≥ that specified for ballast in table to 10 C.F.R. §430.32(m)(2)(ii)(B) | On or after November 14, 201410 | T12 dimming ballasts that are high-frequency and designed to operate two F96T12HO/ES lamps | CSA C654-14 or 10 C.F.R. Appendix Q | CSA C654-14, clause 4 for power factorMust have ballast luminous efficiency that is ≥ that specified for ballast in table to 10 C.F.R. §430.32(m)(2)(ii)(B) | On or after November 14, 2014
note
452Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a fluorescent lamp ballast described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Fluorescent lamp ballasts manufactured on or after February 3, 1995 and before November 14, 2014 | CSA C654-10 | (a)ballast efficacy factor;(b)type and number of fluorescent lamps it is designed to operate; and(c)nominal voltage.2 | Fluorescent lamp ballasts manufactured on or after November 14, 2014, other than T12 dimming ballasts | CSA C654-14 | (a)class number set out in Table 1A of CSA C654-14;(b)ballast luminous efficiency;(c)nominal voltage;(d)ballast input power, in watts;(e)total lamp arc power, in watts; and(f)power factor.3 | T12 dimming ballasts manufactured on or after November 14, 2014 | CSA C654-14 | (a)the type and number of fluorescent lamps it is designed to operate;(b)ballast luminous efficiency;(c)nominal voltage;(d)ballast input power, in watts;(e)total lamp arc power, in watts;(f)power factor; and(g)whether it is high-frequency or low-frequency.note
Subdivision G — Metal Halide Lamp Ballasts
453Definitions#
The following definitions apply in this Subdivision.
CSA C863-16 means the CSA standard CAN/CSA C863-16 entitled Energy efficiency of high-intensity discharge (HID) and low-pressure sodium (LPS) lamp ballasts. (CSA C863-16)
electronic ballast means a ballast that is controlled by a transistor, thyristor or other active electronic component and in which impedance is provided by capacitive or inductive reactance. (ballast électronique)
magnetic-regulated lamp ballast means a ballast that operates at a lagging high power factor and that has
(a)three coils;
(b)isolated secondary windings; and
(c)a constant-voltage regulator that, in conjunction with capacitive reactance, provides power factor correction and lamp wattage regulation. (ballast à régulation magnétique)
metal halide lamp ballast means a device that is used to obtain the voltage, current and waveform necessary for starting and operating a metal halide lamp that has a nominal power of at least 50 W but not more than 1 000 W. It does not include any of the following:
(a)a magnetic-regulated lamp ballast;
(b)a replacement metal halide lamp ballast; or
(c)an electronic ballast that is designed for a nominal voltage of 480 V or to operate a lamp at an output frequency of 1000 Hz or more. (ballast pour lampes aux halogénures métalliques)
replacement metal halide lamp ballast means a ballast that is marketed for use as replacement ballast for a metal halide luminaire installation and that is sold in a package of 10 or fewer. (ballast pour lampes aux halogénures métalliques de remplacement)
10 C.F.R. §431.324 means section 431.324 of Subpart S, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.324)
note
454Energy-using product#
(1)A metal halide lamp ballast is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 455, a metal halide lamp ballast is not considered to be an energy-using product if
(a)it was manufactured before February 10, 2017; or
(b)it is manufactured before December 31, 2019 and is capable of using a nominal voltage of 347 V.
note
455Energy efficiency standards#
(1)The energy efficiency standards set out in Table 3 of CSA C863-16 apply to metal halide lamp ballasts.
(2)A metal halide lamp ballast complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C863-16 or 10 C.F.R. §431.324 that are applicable to a metal halide lamp ballast as defined in section 453.
note
456Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C863-16 and provided to the Minister in respect of a metal halide lamp ballast:
(a)its type;
(b)the efficiency of the lamp and ballast combination, expressed as a percentage;
(c)its nominal voltage;
(d)its input power, in watts;
(e)the power, in watts, of the lamps that the ballast is designed to operate; and
(f)its power factor.
note
Division 8 — Lighting Fixtures
Interpretation
506Definitions#
The following definitions apply in this Division.
CSA C22.2 No. 250.0 means the CSA standard C22.2 No. 250.0-08 entitled Luminaires. (CSA C22.2 No. 250.0)
ITE VTCSH [Repealed, SOR/2018-201, s. 52]
pin-based means, with respect to a socket of a ceiling fan or ceiling fan light kit, one that is designed to hold a fluorescent lamp that is not integrally ballasted and that has a plug-in lamp base. It does not include a GU-24 socket. (à broche)
note
Subdivision A — Torchieres
507Definitions#
The following definitions apply in this Subdivision.
CSA C22.2 No. 250.4 means the CSA standard C22.2 No. 250.4-14 entitled Portable luminaires. (CSA C22.2 No. 250.4)
torchiere means a portable luminaire that has a reflector bowl or similar-shaped reflector that directs light in a predominantly upward direction for the purpose of providing indirect lighting and that may be equipped with one or more additional sockets intended for other lighting functions. (torchère)
508Energy-using product#
(1)A torchiere is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 509, a torchiere is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007.
509Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to torchieres described in column 1 that are manufactured during the periods set out in column 3.
(2)A torchiere complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C22.2 No. 250.4 that are applicable to a torchiere as defined in section 507. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Energy Efficiency Standard | Period of Manufacture1 | Torchieres that have no additional sockets | Total power ≤ 190 W | On or after January 1, 2007 and before January 1, 20102 | Torchieres that have no additional sockets | Total power ≤ 75 W | On or after January 1, 20103 | Torchieres that have one or more additional sockets | Total power ≤ 230 W | On or after January 1, 2007 and before January 1, 20104 | Torchieres that have one or more additional sockets | Total power ≤ 100 W | On or after January 1, 2010
510Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C22.2 No. 250.4 and provided to the Minister in respect of a torchiere:
(a)information that indicates whether the product has lighting functions additional to those of the bowl; and
(b)the total power, expressed in watts, for all lighting functions.
Subdivision B — [Repealed, SOR/2018-201, s. 53]
Subdivision C — Ceiling Fan Light Kits
515Definitions#
The following definitions apply in this Subdivision.
ceiling fan light kit means equipment that is designed to provide light from a ceiling fan and that is
(a)integral to the fan before its retail sale; or
(b)attachable to the fan after its retail sale. (ensemble d’éclairage pour ventilateurs de plafond)
integrated solid-state lighting circuitry [Repealed, SOR/2024-54, s. 1]
non-consumer-replaceable solid-state lighting means the lighting system in a ceiling fan light kit for which the solid-state lighting light source and all components necessary for the starting and stable operation of the light source – that is, the driver, heat sink, intermediate circuitry – cannot be replaced by the consumer without permanently altering the ceiling fan light kit. Furthermore, if the lighting system fails, the entire ceiling fan light kit must be replaced. (éclairage à semi-conducteurs non remplaçable par le consommateur)
10 C.F.R. §430.23(x)(1) means paragraph 430.23(x)(1) of Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.23(x)(1))
10 C.F.R. §430.32(s)(6) means the table to paragraph 430.32(s)(6) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(s)(6))
note
516Energy-using product#
(1)A ceiling fan light kit is prescribed as an energy-using product.
(2)However, a ceiling fan light kit is not considered to be an energy-using product
(b)for the purpose of section 517,
(i)if it was manufactured before January 1, 2010,
(ii)if it is manufactured on or after January 1, 2010 and before January 7, 2019, it has a total power less than or equal to 10 W or only pin-based sockets, or
(iii)if it is manufactured on or after January 7, 2019, it has at least one socket, has maximum wattage markings on each socket that together indicate that the combined total power for the lighting is less than or equal to 70 W and does not have non-consumer-replaceable solid-state lighting.
note
517Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to ceiling fan light kits described in column 1 that are manufactured during the periods set out in column 4.
(2)A ceiling fan light kit complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a ceiling fan light kit as defined in section 515. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Ceiling fan light kits | CSA C22.2 No. 250.0 | Total power for lighting ≤ 190 W | On or after January 1, 2010 and before January 7, 20192 | Ceiling fan light kits that have at least one socket, that are not packaged with a lamp for each socket and that do not have non-consumer-replaceable solid-state lighting | CSA C22.2 No. 250.0 | Total power for lighting ≤ 70 W | On or after January 7, 20193 | Ceiling fan light kits that have at least one socket, that are packaged with a lamp for each socket and that do not have non-consumer-replaceable solid-state lighting | 10 C.F.R. §430.23(x)(1) | Lighting efficacy ≥ minimum required efficacy in 10 C.F.R. §430.32(s)(6) | On or after January 7, 20194 | Ceiling fan light kits that have non-consumer-replaceable solid-state lighting | 10 C.F.R. §430.23(x)(1) | Lighting efficacy ≥ minimum required efficacy in 10 C.F.R. §430.32(s)(6) | On or after January 7, 2019
note
518Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a ceiling fan light kit:
(a)if it has at least one socket, the type of socket and the number of each type of socket;
(b)if it has non-consumer-replaceable solid-state lighting, the lighting efficacy, expressed in lumens per watt, and the total light output, expressed in lumens;
(c)if it has a pin-based socket, the ballast type;
(e)the total power for the lighting, expressed in watts.
(2)The information must be collected in accordance with CSA C22.2 No. 250.0 or 10 C.F.R. §430.23(x)(1).
note
Subdivision D — Exit Signs
519Definitions#
The following definitions apply in this Subdivision.
legend means any of the following that is displayed on an exit sign:
(b)the word “EXIT” or “SORTIE”. (légende)
note
520Energy-using product#
(1)An exit sign is prescribed as an energy-using product.
(2)However, for the purpose of section 4, an exit sign is not considered to be an energy-using product unless it is manufactured on or after November 1, 2004.
521Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to exit signs described in column 1.
(2)An exit sign complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C860 that are applicable to an exit sign as defined in section 519. | Column 1 | Column 2Item | Energy-using Product | Energy Efficiency Standard1 | Type 1 and Type 2 exit signs | Wattage ≤ 5 W × (number of legends)2 | Type 3 exit signs | Wattage ≤ 5 W × (number of legends) + 5 W
Subdivision E — Traffic Signal Modules
523Definitions#
The following definitions apply in this Subdivision.
traffic signal module means a self-contained device that is designed to
(a)fit into a traffic signal housing; and
(b)provide drivers with movement information by means of a red or green traffic signal indicator that has a nominal diameter of 200 mm (8 inches) or 300 mm (12 inches). (module de signalisation routière)
VTCSH Arrow means the Institute of Transportation Engineers standard entitled Vehicle Traffic Control Signal Heads: Light Emitting Diode (LED) Vehicle Arrow Traffic Signal Supplement, dated July 1, 2007. (VTCSH Arrow)
VTCSH Circular means the Institute of Transportation Engineers standard entitled Vehicle Traffic Control Signal Heads: Light Emitting Diode (LED) Circular Signal Supplement, dated June 27, 2005. (VTCSH Circular)
note
524Energy-using product#
(1)A traffic signal module is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 525, a traffic signal module is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007.
525Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to traffic signal modules described in column 1.
(2)For the purpose of subsection (1), the maximum power and nominal power of a traffic signal module must be determined in accordance with the following procedures:
(a)the luminous intensity of the product must be determined in accordance with the procedures established by the standard set out in column 2 that are applicable to a traffic signal module as defined in section 523;
(b)the product’s power must be measured using a watt meter that has an accuracy of ± 1%;
(c)when determining the product’s maximum power, the product must be
(i)mounted in a temperature testing chamber with the lens portion of the product outside the chamber, and
(d)when determining the product’s nominal power, the product must be operated for a minimum of 60 minutes at an ambient temperature of 25°C.
| Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Energy Efficiency Standard1 | Traffic signal modules that have a red traffic signal indicator that has a nominal diameter of 200 mm (8 inches) | VTCSH Circular | Maximum power ≤ 13 WNominal power ≤ 8 W2 | Traffic signal modules that have a red traffic signal indicator that has a nominal diameter of 300 mm (12 inches) | VTCSH Circular | Maximum power ≤ 17 WNominal power ≤ 11 W3 | Traffic signal modules that have a green traffic signal indicator that has a nominal diameter of 200 mm (8 inches) | VTCSH Circular | Maximum power ≤ 12 WNominal power ≤ 12 W4 | Traffic signal modules that have a green traffic signal indicator that has a nominal diameter of 300 mm (12 inches) | VTCSH Circular | Maximum power ≤ 15 WNominal power ≤ 15 W5 | Traffic signal modules that have a red arrow traffic signal indicator | VTCSH Arrow | Maximum power ≤ 12 WNominal power ≤ 9 W6 | Traffic signal modules that have a green arrow traffic signal indicator | VTCSH Arrow | Maximum power ≤ 11 WNominal power ≤ 11 W
note
526Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a traffic signal module:
(a)its type;
(b)its maximum power, expressed in watts; and
(c)its nominal power, expressed in watts.
(2)The information must be collected in accordance with
(a)VTCSH Arrow, if the traffic signal module has an arrow traffic signal indicator; or
(b)VTCSH Circular, if the traffic signal module has any other traffic signal indicator.
Subdivision F — Pedestrian Modules
527Definitions#
The following definitions apply in this Subdivision.
pedestrian module means a self-contained device that is designed
(a)to fit into a pedestrian signal housing; and
(b)to provide pedestrians with movement information by means of a walking person display or a hand display but not by means of a countdown message. (module de signalisation piétonnière)
PTCSI means the Institute of Transportation Engineers standard entitled Pedestrian Traffic Control Signal Indicators: Light Emitting Diode (LED) Signal Modules, dated August 4, 2010. (PTCSI)
528Energy-using product#
(1)A pedestrian module is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 529, a pedestrian module is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007.
529Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to pedestrian modules described in column 1.
(2)For the purpose of subsection (1), the maximum power and nominal power of a pedestrian module must be determined in accordance with the following procedures:
(a)the luminous intensity of the product must be determined in accordance with the procedures established by PTCSI that are applicable to a pedestrian module as defined in section 527;
(b)the product’s power must be measured using a watt meter that has an accuracy of ± 1%;
(c)when determining the product’s maximum power, the product must be
(i)mounted in a temperature testing chamber with the lens portion of the product outside the chamber, and
(d)when determining the product’s nominal power, the product must be operated for a minimum of 60 minutes at an ambient temperature of 25°C.
| Column 1 | Column 2Item | Energy-using Product | Energy Efficiency Standard1 | Pedestrian modules that have a walking person display and a hand display | Maximum power ≤ 16 WNominal power ≤ 13 W2 | Pedestrian modules that have a walking person display only | Maximum power ≤ 12 WNominal power ≤ 9 W3 | Pedestrian modules that have a hand display only | Maximum power ≤ 16 WNominal power ≤ 13 W
Division 9 — Electronic Products
Interpretation
573Definitions#
The following definitions apply in this Division.
CSA C62301 means the CSA standard CAN/CSA-C62301:11 entitled Household electrical appliances – Measurement of standby power. (CSA C62301)
information display means a clock or other device that provides visual alphanumeric or graphical information or indicates the status of the equipment. (affichage)
medical device has the same meaning as in section 1 of the Medical Devices Regulations. (instrument médical)
note
Subdivision A — Compact Audio Products
574Definitions#
The following definitions apply in this Subdivision.
compact audio product means a product that consists of an amplifier and a terrestrial tuner that are encased in a single housing — including a product that can produce sound from another media — and that uses mains power as at least one source of power and has attached or separable speakers. (produit audio compact)
off mode means the mode in which the product, while connected to mains power, cannot produce sound or provide any mechanical function and cannot be switched into another mode except by means of a manual switch on the product. (mode arrêt)
standby mode means the mode in which the product, while connected to mains power,
(a)is not producing sound, providing mechanical function or exchanging data with, or receiving it from, an external source; and
(b)can be switched into another mode with a remote control unit, an internal signal or an internal timer. (mode veille)
note
575Energy-using product#
(1)A compact audio product is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 576, a compact audio product is not considered to be an energy-using product unless it is manufactured on or after May 1, 2011.
576Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to compact audio products described in column 1 that are manufactured during the periods set out in column 3.
(2)A compact audio product complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C62301 that are applicable to a compact audio product as defined in section 574. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Energy Efficiency Standard | Period of Manufacture1 | Compact audio products | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 3 W in standby mode; and(b)≤ 1 W in off mode. | On or after May 1, 2011 and before January 1, 20132 | Compact audio products, other than clock radios | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 1 W in standby mode with information display active;(b)≤ 0.5 W in standby mode with information display inactive;(c)≤ 0.5 W in standby mode when there is no information display; and(d)≤ 0.5 W in off mode. | On or after January 1, 20133 | Compact audio products that are clock radios | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 2 W in standby mode with information display active; and(b)≤ 1 W in off mode. | On or after January 1, 2013
577Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C62301 and provided to the Minister in respect of a compact audio product:
(a)its type;
(b)if it was manufactured before January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts;
(c)if it is manufactured on or after January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts, as applicable,
(i)with the information display active,
(ii)with the information display inactive, and
(iii)without the information display;
(e)if it has off mode, its power consumption, expressed in watts, in off mode.
Subdivision B — Video Products
578Definitions#
The following definitions apply in this Subdivision.
off mode means the mode in which the product, while connected to mains power, cannot provide any mechanical function and cannot be switched into another mode with a remote control unit, a timer or another internal or external signal. (mode arrêt)
standby mode means the mode in which the product, while connected to mains power,
(a)is not producing video or audio output signals, providing any mechanical function or exchanging data with, or receiving it from, an external source; and
(b)can be switched into another mode with a remote control unit, an internal signal or an internal timer. (mode veille)
video product means a household electronic product that is encased in a single housing, requires a power supply device in order to operate and is designed
(a)to be connected to mains power; and
(b)primarily to do one or both of the following, namely, produce audio and video signals from, or record those signals to, digital or analog media.
It does not include a camera or a portable DVD player that has both an integral display screen and a DC power source. (appareil vidéo)
note
579Energy-using product#
(1)A video product is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 580, a video product is not considered to be an energy-using product unless it is manufactured on or after May 1, 2011.
580Energy efficiency standards#
(1)The energy efficiency standards set out in column 1 of the table to this section apply to video products that are manufactured during the periods set out in column 2.
(2)A video product complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C62301 that are applicable to a video product as defined in section 578. | Column 1 | Column 2Item | Energy Efficiency Standard | Period of Manufacture1 | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 3 W in standby mode; and(b)≤ 1 W in off mode. | On or after May 1, 2011 and before January 1, 20132 | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 1 W in standby mode with information display active;(b)≤ 0.5 W in standby mode with information display inactive;(c)≤ 0.5 W in standby mode without information display; and(d)≤ 0.5 W in off mode. | On or after January 1, 2013
581Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C62301 and provided to the Minister in respect of a video product:
(a)if it was manufactured before January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts;
(b)if it is manufactured on or after January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts, as applicable,
(i)with the information display active,
(ii)with the information display inactive, and
(iii)without the information display;
(c)if it has standby mode, the period, expressed in minutes, that begins when standby mode is enabled and ends when the measurement of power consumption in that mode is completed;
(d)if it has off mode, its power consumption, expressed in watts, in off mode; and
(e)the type of playback or recording technology that it has.
Subdivision C — Televisions
582Definitions#
The following definitions apply in this Subdivision.
off mode means the mode in which the product, while connected to mains power, cannot produce either sound or picture or provide any mechanical function and cannot be switched into another mode with a remote control unit, a timer or another internal or external signal. (mode arrêt)
standby mode means the mode in which the product, while connected to mains power,
(a)is not producing sound or picture, providing any mechanical function or exchanging data with, or receiving it from, an external source; and
(b)can be switched into another mode with a remote control unit, an internal signal or an internal timer. (mode veille)
television means an analog or digital product, with or without an internal tuner, that is designed primarily for the display and reception of a terrestrial, satellite, cable, Internet Protocol TV or other broadcast or recorded transmission of analog or digital video and audio signals and includes
(c)a television that is marketed exclusively for commercial use and is without an internal tuner; or
(d)a television that is marketed primarily for use as a computer monitor. (téléviseur)
It does not include
note
583Energy-using product#
(1)A television is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 584, a television is not considered to be an energy-using product unless it is manufactured on or after May 1, 2011.
584Energy efficiency standards#
(1)The energy efficiency standards set out in column 1 of the table to this section apply to televisions that are manufactured during the periods set out in column 2.
(2)A television complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C62301 that are applicable to a television as defined in section 582. | Column 1 | Column 2Item | Energy Efficiency Standard | Period of Manufacture1 | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 4 W in standby mode; and(b)≤ 1 W in off mode. | On or after May 1, 2011 and before January 1, 20132 | Must be capable of entering standby mode or off mode.Power consumption of product must be, as applicable,(a)≤ 1 W in standby mode with information display active;(b)≤ 0.5 W in standby mode with information display inactive;(c)≤ 0.5 W in standby mode without information display; and(d)≤ 0.5 W in off mode. | On or after January 1, 2013
585Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C62301 and provided to the Minister in respect of a television:
(a)if it was manufactured before January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts;
(b)if it is manufactured on or after January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts, as applicable,
(i)with the information display active,
(ii)with the information display inactive, and
(iii)without the information display;
(d)if it has off mode, its power consumption, expressed in watts, in off mode.
Subdivision D — External Power Supplies
586Definitions#
(1)The following definitions apply in this Subdivision.
adaptive external power supply means an external power supply that, without user intervention and while it is connected to mains power and each output is connected to a load, can alter the output voltage using a digital communication protocol with the end-use product. (bloc d’alimentation externe adaptatif)
CSA C381.1 means the CSA standard CAN/CSA-C381.1-08 entitled Test method for calculating the energy efficiency of single-voltage external ac-ac and ac-ac power supplies. (CSA C381.1)
CSA C381.1-17 means the CSA standard CAN/CSA C381.1-17 entitled Energy performance of external ac-dc and ac-ac power supplies. (CSA C381.1-17)
detachable battery pack means a battery that is encased in an enclosure separate from an end-use product and that is designed to be removed or disconnected from the end-use product for recharging. (bloc-batterie amovible)
direct operation external power supply means a power supply device that is capable of operating an end-use product, other than a battery charger, without the assistance of a battery. (bloc d’alimentation externe à fonctionnement direct)
external power supply means a single-voltage external power supply or a multiple-voltage external power supply that is designed to be used with a household or office end-use product that constitutes the primary load. It does not include
(a)a direct operation external power supply that has a nominal output voltage of less than 3 V and a nominal output current of 1 000 mA or more and that charges the battery of an end-use product that is fully or primarily motor-operated;
(b)an indirect operation external power supply that has a nominal output power of greater than 250 W;
(c)a device that powers the charger of a detachable battery pack of an end-use product;
(d)a device that is an accessory to a medical device; or
(e)a device that is solely designed to power solid-state lighting or a ceiling fan that has a direct current motor. (bloc d’alimentation externe)
indirect operation external power supply means a power supply device that can only operate an end-use product with the assistance of a battery. (bloc d’alimentation externe à fonctionnement indirect)
multiple-voltage external power supply means a device that is designed to convert line voltage AC input into more than one simultaneous lower voltage AC or DC outputs. (bloc d’alimentation externe à tensions multiples)
replacement external power supply means an external power supply that is marked as a replacement to be used with a specific end-use product that was manufactured before July 1, 2017. (bloc d’alimentation externe de remplacement)
security external power supply means an external power supply manufactured before July 1, 2017 that
(a)is designed to convert line voltage AC into lower voltage AC output;
(b)has a nominal output power of 20 W or more; and
(c)is designed for and marketed with equipment that operates continuously in on mode to perform any of the following principal functions:
(i)to monitor, detect, record or provide notification of any intrusion on real property or immovables, or access to real property or immovables or physical assets,
(ii)to provide notification of threats to personal safety resulting from an intrusion or access referred to in subparagraph (i),
(iii)to monitor, detect, record or provide notification of fire, gas, smoke, flooding or any other physical threats to real property or immovables, physical assets or personal safety, or
(iv)to deter or control access to real property or immovables or physical assets or prevent the unauthorized removal of physical assets.
It includes an external power supply for equipment that is designed and marketed with a built-in alarm or theft-deterrent feature and whose principal functions are those referred to in paragraph (c). (bloc d’alimentation externe de sécurité)
single-voltage external power supply means a device that is designed to convert line voltage AC input into only one lower AC or DC voltage output at a time. (bloc d’alimentation externe à simple tension)
10 C.F.R. Appendix Z means Appendix Z to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of External Power Supplies, as amended from time to time. (appendice Z 10 C.F.R.)
10 C.F.R. §430.32(w)(1)(i) means the table to paragraph 430.32(w)(1)(i) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(w)(1)(i))
verification mark has the same meaning as in section 2. (marque de vérification)
(2)[Repealed, SOR/2018-201, s. 64] (repealed)
note
587Energy-using product#
(1)An external power supply is prescribed as an energy-using product.
(2)However, an external power supply is not considered to be an energy-using product
(a)for the purposes of sections 4 and 5 if
(i)it was manufactured before July 1, 2010, or
(A)it is a multiple-voltage external power supply or an adaptive external power supply,
(B)it is a direct operation external power supply that has a nominal output power of greater than 250 W, or
(C)it is an indirect operation external power supply that has a nominal output voltage of greater than 3 V and a nominal output current of less than 1 000 mA and that charges the battery of an end-use product that is fully or primarily motor-operated; and
(b)for the purpose of section 588 if
(i)it was manufactured before July 1, 2010,
(A)it is a multiple-voltage external power supply or an adaptive external power supply,
(B)it is a direct operation external power supply that has a nominal output power of greater than 250 W, or
(C)it is an indirect operation external power supply that has a nominal output voltage of greater than 3 V and a nominal output current of less than 1 000 mA and that charges the battery of an end-use product that is fully or primarily motor-operated, or
(iii)it was manufactured before July 1, 2013 and is a replacement external power supply.
note
588Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to external power supplies described in column 1 that are manufactured during the periods set out in column 4.
(2)An external power supply complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to an external power supply as defined in subsection 586(1). | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | External power supplies, other than replacement external power supplies | CSA C381.1 or 10 C.F.R. Appendix Z | 10 C.F.R. §430.32(w)(1)(i) for efficiency in active mode and, if product is not a security external power supply, power in no-load mode ≤ 0.5 W | On or after July 1, 2010 and before July 1, 20172 | Direct operation external power supplies other than replacement external power supplies | CSA C381.1-17 or 10 C.F.R. Appendix Z | CSA C381.1-17, Table D.1, for efficiency in active mode and power in no-load mode | On or after July 1, 20173 | Indirect operation external power supplies other than replacement external power supplies | CSA C381.1 or 10 C.F.R. Appendix Z | 10 C.F.R. §430.32(w)(1)(i) for efficiency in active mode and, if product is not a security external power supply, power in no-load mode ≤ 0.5 W | On or after July 1, 20174 | Replacement external power supplies | CSA C381.1 or 10 C.F.R. Appendix Z | 10 C.F.R. §430.32(w)(1)(i) for efficiency in active mode and, if product is not a security external power supply, power in no-load mode ≤ 0.5 W | On or after July 1, 2013 and before February 10, 20205 | Replacement external power supplies | CSA C381.1-17 or 10 C.F.R. Appendix Z | CSA C381.1-17, Table D.1, for efficiency in active mode and power in no-load mode | On or after February 10, 2020
note
589Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must provided to the Minister in respect of an external power supply:
(a)information that indicates whether the product is a single-voltage external power supply or a multiple-voltage external power supply;
(c)its nominal output power, expressed in watts, at the highest and lowest power settings, if applicable;
(d)its average efficiency at the highest and lowest power settings, if applicable;
(e)its power in no-load mode, expressed in watts;
(f)the Roman numeral mark, if applicable;
(g)information that indicates whether the product bears a verification mark; and
(h)information that indicates whether the product is a replacement external power supply or a security external power supply and, if it is one of those power supplies, the end-use product or equipment, as applicable, and the model number and brand of that end-use product or equipment.
(2)The information must be collected in accordance with a standard set out in column 2 of the table to this section in respect of an external power supply described in column 1. | Column 1 | Column 2Item | Energy-using Product | Testing Standard1 | External power supplies, other than replacement external power supplies, that are manufactured on or after July 1, 2010 and before July 1, 2017 | CSA C381.1 or 10 C.F.R. Appendix Z2 | Direct operation external power supplies, other than replacement external power supplies, that are manufactured on or after July 1, 2017 | CSA C381.1-17 or 10 C.F.R. Appendix Z3 | Indirect operation external power supplies, other than replacement external power supplies, that are manufactured on or after July 1, 2017 | CSA C381.1 or 10 C.F.R. Appendix Z4 | Replacement external power supplies that are manufactured on or after July 1, 2013 and before February 10, 2020 | CSA C381.1 or 10 C.F.R. Appendix Z5 | Replacement external power supplies that are manufactured on or after February 10, 2020 | CSA C381.1-17 or 10 C.F.R. Appendix Z
note
Subdivision E — Battery Chargers
590Definitions#
The following definitions apply in this Subdivision.
backup battery charger means a device that
(a)is incorporated into an end-use product, including a device that is incorporated into an uninterruptible power supply or that uses an external power supply, that is designed to operate continuously using mains power; and
(b)recharges a battery that is used to maintain the continuity of electrical power to the end-use product such that the product can continue its full or partial operation in the event of a failure of mains power. (chargeur de batterie de secours)
battery charger means a device that charges the battery of a wheelchair, golf cart, low-speed vehicle or any other end-use product. It does not include any of the following:
(a)a device that charges the battery of a vehicle other than a wheelchair, golf cart or low-speed vehicle;
(b)a device that charges the battery of a medical device;
(c)a wireless battery charger, other than a wireless battery charger that is inductive and designed for wet environments; or
(d)a backup battery charger. (chargeur de batterie)
CSA C381.2-17 means the CSA standard CSA C381.2-17 entitled Energy performance of battery-charging systems and uninterruptible power supplies. (CSA C381.2-17)
low-speed vehicle means a vehicle that
(a)does not use fuel as an on-board source of energy;
(b)travels on two or more wheels;
(c)is powered by an electric power train that is designed to allow the vehicle to attain a speed of no greater than 40 km/h over a distance of 1.6 km on a paved level surface; and
(d)has a loaded weight, as specified by its manufacturer, of less than 1 361 kg. (véhicule à basse vitesse)
10 C.F.R. Appendix Y means Appendix Y to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Battery Chargers, as amended from time to time. (appendice Y 10 C.F.R.)
note
591Energy-using product#
(1)A battery charger is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 592, a battery charger is not considered to be an energy-using product unless it is manufactured on or after June 13, 2019.
note
592Energy efficiency standard#
(1)A battery charger must have a unit energy consumption that is less than or equal to that set out for the battery charger’s product class in Table C.1 of CSA C381.2-17.
(2)A battery charger complies with the energy efficiency standard if it meets that standard when tested in accordance with the testing procedures established by CSA C381.2-17 or 10 C.F.R. Appendix Y that are applicable to a battery charger as defined in section 590.
note
593Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C381.2-17 or 10 C.F.R. Appendix Y and provided to the Minister in respect of a battery charger:
(a)its product class;
(b)its rated battery energy (Ebatt), expressed in watt-hours;
(c)its unit energy consumption, expressed in kilowatt-hours per year;
(e)if an external power supply was used to test the battery charger, the power supply’s model number and the name of its manufacturer.
note
Subdivision F — Line Voltage Thermostats
594Definitions#
(1)The following definitions apply in this Subdivision.
control point means the temperature value, measured at the centre of the test room, that is used to verify the performance of a line voltage thermostat at the set point. (température de contrôle)
CSA C828-19 means the CSA standard CSA C828:19 entitled Performance requirements for line voltage thermostats used with individual room electric space heating devices. (CSA C828-19)
differential means the difference between the maximum and minimum air temperatures at the centre of the test room, calculated at 50% duty cycle. (différentielle)
line voltage thermostat means, subject to subsection (2), a thermostat that is used with a line voltage of between 120 V and 240 V, is intended for switching of a controlled resistive heating load and is one of the following:
(a)a wall-mounted thermostat designed to be used with baseboards, panel convectors or radiant floors;
(b)a built-in thermostat having a nominal load from 1000 W to 1500 W that is used in baseboards or panel convectors; or
(c)a two-component thermostat. (thermostat à tension de secteur)
(2)The definition line voltage thermostat in subsection (1) does not include thermostats designed to be used exclusively for or built into
(a)fan-forced heaters;
(b)kick space heaters;
(c)fireplaces;
(d)thermal storage heaters;
(f)portable heaters; or
(g)central heating units under the control of a single thermostat.
note
595Energy-using product#
(1)A line voltage thermostat is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 596 and 597, a line voltage thermostat is not considered to be an energy-using product unless
(a)in the case of a wall-mounted thermostat or a two-component thermostat, it is manufactured on or after July 1, 2026; and
(b)in the case of a built-in thermostat, it is manufactured on or after July 1, 2027.
note
596Energy efficiency standards#
(1)The energy efficiency standards set out in clause 4.4 of CSA C828-19 apply to a line voltage thermostat.
(2)A line voltage thermostat complies with the energy efficiency standard when tested in accordance with the applicable testing procedures established by CSA C828-19.
note
597Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C828-19 and provided to the Minister in respect of a line voltage thermostat:
(a)its equipment class;
(b)its nominal voltage;
(c)its maximum nominal load, expressed in watts;
(d)its minimum nominal load, expressed in watts;
(e)its droop, expressed in degrees Celsius;
(f)its differential, expressed in degrees Celsius; and
(g)its control point precision, expressed in degrees Celsius.
note
Division 10 — Commercial Refrigeration
Interpretation
Subdivision A — Commercial Refrigerators, Refrigerator-Freezers and Freezers
636Definitions#
The following definitions apply in this Subdivision.
AV means, in respect of a commercial refrigerator-freezer, its adjusted volume in litres, which is the sum of the refrigerator volume and 1.63 times the freezer volume. (VC)
closed means
(a)in respect of a refrigerated compartment of a commercial refrigerator, commercial refrigerator-freezer or commercial freezer, that all its points of access can be closed off from the outside by a physical barrier and from which any refrigerated item can be accessed by opening a door or drawer; and
(b)in respect of a commercial refrigerator, commercial refrigerator-freezer or commercial freezer, that all of its compartments are as described in paragraph (a). (type fermé)
commercial freezer means a freezer that is self-contained or remote-condensing, that uses or is designed to be used with a vapour-compression refrigeration system and whose compartments are all designed for the freezing and display or storage of food, beverages or ice at temperatures below 0°C. It does not include a household freezer or walk-in freezer. (congélateur commercial)
commercial refrigerator means a refrigerator that is self-contained or remote-condensing, that uses or is designed to be used with a vapour-compression refrigeration system and whose compartments are all designed for the display or storage of food, beverages or flowers at temperatures at or above 0°C. It does not include a household refrigerator, refrigerated buffet table, refrigerated preparation table or walk-in cooler. (réfrigérateur commercial)
commercial refrigerator-freezer means a refrigerator-freezer that is self-contained or remote-condensing, that uses or is designed to be used with a vapour-compression refrigeration system and that has two or more compartments, at least one of which is designed for the display or storage of food and beverages at temperatures at or above 0°C and at least one of which is designed for the freezing and display or storage of food and beverages at temperatures below 0°C. It does not include a household refrigerator-freezer, walk-in freezer or walk-in cooler. (réfrigérateur-congélateur commercial)
ice cream freezer means a commercial freezer that is designed to operate at temperatures at or below –21°C ± 1.1°C and that is designed or marketed for the storage, display or dispensing of ice cream. (congélateur de crème glacée)
open means, in respect of a commercial refrigerator, commercial refrigerator-freezer or commercial freezer — or a refrigerated compartment of one — that it is not closed. (type ouvert)
pull-down temperature reduction capability means the capability of a commercial refrigerator, when it is situated in an area that has an ambient temperature of 32.22˚C and when it is fully loaded with 355 mL beverage cans that are at a temperature of 32.22˚C at the time of loading, to cool those cans to an average stable temperature of 3.33˚C in 12 hours or less. (capacité d’abaisser la température)
TDA means the total display area of a product, expressed in square metres. (TDA)
transparent means
(a)in respect of a refrigerated compartment of a commercial refrigerator, commercial refrigerator-freezer or commercial freezer, that it is closed and has a TDA that is at least 75% of the geometrically projected area of the refrigerated space on the plane of the face with the largest access space; and
(b)in respect of a commercial refrigerator, commercial refrigerator-freezer or commercial freezer, that all of its compartments are as described in paragraph (a). (transparent)
V means, in respect of a refrigerated compartment of a commercial refrigerator, commercial refrigerator-freezer or commercial freezer, its volume, expressed in litres, calculated in accordance with clause 8 of CSA C657. (V)
note
Commercial Refrigerators
637Energy-using product#
(1)A commercial refrigerator is prescribed as an energy-using product.
(2)However, a commercial refrigerator is not considered to be an energy-using product
note
638Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to commercial refrigerators described in column 1 that are manufactured during the periods set out in column 4.
(2)A commercial refrigerator complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a commercial refrigerator as defined in section 636. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Commercial refrigerators that are self-contained, closed and not transparent | CSA C657, Test Procedure A | Edaily ≤ 0.00441 V + 4.22 | On or after April 1, 2007 and before January 1, 20082 | Commercial refrigerators that are self-contained, closed and not transparent | CSA C657, Test Procedure A | Edaily ≤ 0.00441 V + 2.76 | On or after January 1, 2008 and before January 1, 20103 | Commercial refrigerators that are self-contained, closed and not transparent | CSA C657, Test Procedure A | Edaily ≤ 0.00353 V + 2.04 | On or after January 1, 2010 and before March 27, 20174 | Commercial refrigerators that are self-contained and transparent | CSA C657, Test Procedure A | Edaily ≤ 0.00607 V + 5.78 | On or after April 1, 2007 and before January 1, 20085 | Commercial refrigerators that are self-contained and transparent | CSA C657, Test Procedure A | Edaily ≤ 0.00607 V + 4.77 | On or after January 1, 2008 and before January 1, 20106 | Commercial refrigerators that are self-contained and transparent and that do not have pull-down temperature reduction capability | CSA C657, Test Procedure A | Edaily ≤ 0.00424 V + 3.34 | On or after January 1, 2010 and before March 27, 20177 | Commercial refrigerators that are self-contained and transparent and that have pull-down temperature reduction capability | CSA C657, Test Procedure A | Edaily ≤ 0.00445 V + 3.51 | On or after January 1, 2010 and before March 27, 20178 | Commercial refrigerators that are self-contained and open | CSA C657, Test Procedure A | CSA C657, Table 5 | On or after January 1, 2012 and before March 27, 20179 | Commercial refrigerators that are remote-condensing | CSA C657, Test Procedure A | CSA C657, Table 5 | On or after January 1, 2012 and before March 27, 201710 | Commercial refrigerators | CSA C657, Test Procedure B | CSA C657, Table 6 | On or after March 27, 2017
note
639Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a commercial refrigerator:
(a)its Edaily;
(2)The information must be collected in accordance with one of the following standards:
(a)CSA C657, Test Procedure A, if the product was manufactured before March 27, 2017; or
(b)CSA C657, Test Procedure B, if the product is manufactured on or after March 27, 2017.
note
Commercial Refrigerator-Freezers
640Energy-using product#
(1)A commercial refrigerator-freezer is prescribed as an energy-using product.
(2)However, a commercial refrigerator-freezer is not considered to be an energy-using product
(a)for the purposes of sections 4 and 5, unless
(ii)it is self-contained, is open and is manufactured on or after January 1, 2012, or
note
641Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to commercial refrigerator-freezers described in column 1 that are manufactured during the periods set out in column 4.
(2)A commercial refrigerator-freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a commercial refrigerator-freezer as defined in section 636. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Commercial refrigerator-freezers that are self-contained, closed and not transparent | CSA C657, Test Procedure A | Edaily ≤ 0.00964 AV + 2.63 | On or after April 1, 2007 and before January 1, 20082 | Commercial refrigerator-freezers that are self-contained, closed and not transparent | CSA C657, Test Procedure A | Edaily ≤ 0.00964 AV + 1.65 | On or after January 1, 2008 and before January 1, 20103 | Commercial refrigerator-freezers that are self-contained, closed and not transparent | CSA C657, Test Procedure A | Edaily ≤ the greater of (0.00953 AV – 0.71) and 0.70 | On or after January 1, 2010 and before March 27, 20174 | Commercial refrigerator-freezers that are self-contained and open or transparent | CSA C657, Test Procedure A | CSA C657, Table 5 | On or after January 1, 2012 and before March 27, 20175 | Commercial refrigerator-freezers that are remote-condensing | CSA C657, Test Procedure A | CSA C657, Table 5 | On or after January 1, 2012 and before March 27, 20176 | Commercial refrigerator-freezers | CSA C657, Test Procedure B | CSA C657, Table 6 | On or after March 27, 2017
note
642Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a commercial refrigerator-freezer described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Commercial refrigerator-freezers that are self-contained, closed, not transparent and manufactured on or after April 1, 2007 and before March 27, 2017 | CSA C657, Test Procedure A | (a)Edaily;(b)AV; and(c)for each compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting.2 | Commercial refrigerator-freezers that are self-contained, transparent and manufactured on or after April 1, 2007 and before January 1, 2012 | CSA C657, Test Procedure A | (a)Edaily;(b)AV; and(c)for each compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting.3 | Commercial refrigerator-freezers that are self-contained, open or transparent and manufactured on or after January 1, 2012 and before March 27, 2017 | CSA C657, Test Procedure A | (a)Edaily;(b)for each compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting; and(c)for each compartment, its equipment class designation and TDA.4 | Commercial refrigerator-freezers that are remote-condensing and manufactured on or after January 1, 2012 and before March 27, 2017 | CSA C657, Test Procedure A | (a)Edaily;(b)for each compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting; and(c)for each compartment, its equipment class designation and TDA.5 | Commercial refrigerator-freezers that are manufactured on or after March 27, 2017 | CSA C657, Test Procedure B | (a)Edaily;(b)for each compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting; and(c)for each compartment, its equipment class designation and its TDA or V, as applicable.note
Commercial Freezers
643Energy-using product#
(1)A commercial freezer is prescribed as an energy-using product.
(2)However, a commercial freezer is not considered to be an energy-using product
note
644Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to commercial freezers described in column 1 that are manufactured during the periods set out in column 4.
(2)A commercial freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a commercial freezer as defined in section 636. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Commercial freezers that are self-contained and open, other than ice cream freezers | CSA C657, Test Procedure A | CSA C657, Table 5 | On or after January 1, 2012 and before March 27, 20172 | Commercial freezers that are self-contained, closed and not transparent and have a volume of < 340 L | CSA C657, Test Procedure A | Edaily ≤ 7.62 | On or after April 1, 2007 and before January 1, 20083 | Commercial freezers that are self-contained, closed and not transparent and have a volume of < 340 L | CSA C657, Test Procedure A | Edaily ≤ 7.07 | On or after January 1, 2008 and before January 1, 20104 | Commercial freezers that are self-contained, closed and not transparent and have a volume of ≥ 340 L | CSA C657, Test Procedure A | Edaily ≤ 0.0141 V + 2.83 | On or after April 1, 2007 and before January 1, 20085 | Commercial freezers that are self-contained, closed and not transparent and have a volume of ≥ 340 L | CSA C657, Test Procedure A | Edaily ≤ 0.0141 V + 2.28 | On or after January 1, 2008 and before January 1, 20106 | Commercial freezers that are self-contained, closed and not transparent | CSA C657, Test Procedure A | Edaily ≤ 0.01413 V + 1.38 | On or after January 1, 2010 and before January 1, 20127 | Commercial freezers that are self-contained, closed and not transparent, other than ice cream freezers | CSA C657, Test Procedure A | Edaily ≤ 0.01413 V + 1.38 | On or after January 1, 2012 and before March 27, 20178 | Commercial freezers that are self-contained and transparent | CSA C657, Test Procedure A | Edaily ≤ 0.0332 V + 5.10 | On or after April 1, 2007 and before January 1, 20109 | Commercial freezers that are self-contained and transparent | CSA C657, Test Procedure A | Edaily ≤ 0.02649 V + 4.10 | On or after January 1, 2010 and before January 1, 201210 | Commercial freezers that are self-contained and transparent, other than ice cream freezers | CSA C657, Test Procedure A | Edaily ≤ 0.02649 V + 4.10 | On or after January 1, 2012 and before March 27, 201711 | Commercial freezers that are remote-condensing, other than ice cream freezers | CSA C657, Test Procedure A | CSA C657, Table 5 | On or after January 1, 2012 and before March 27, 201712 | Ice cream freezers | CSA C657, Test Procedure A | CSA C657, Table 5 | On or after January 1, 2012 and before March 27, 201713 | Commercial freezers | CSA C657, Test Procedure B | CSA C657, Table 6 | On or after March 27, 2017
note
645Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a commercial freezer:
(a)its Edaily; and
(2)The information must be collected in accordance with one of the following standards:
(a)CSA C657, Test Procedure A, if the product was manufactured before March 27, 2017; or
(b)CSA C657, Test Procedure B, if the product is manufactured on or after March 27, 2017.
note
Subdivision B — Refrigerated Vending Machines
646Definitions#
The following definitions apply in this Subdivision.
ASHRAE 32.1 means the ASHRAE standard 32.1-2010 entitled Methods of Testing for Rating Vending Machines for Bottled, Canned, and Other Sealed Beverages. (ASHRAE 32.1)
combination vending machine means a refrigerated beverage vending machine containing two or more compartments separated by a solid partition — whether or not they share a product delivery chute — in which at least one compartment is designed to be refrigerated and has temperature controls; and at least one compartment is not designed to be refrigerated and does not contain temperature controls. (distributeur automatique mixte))
refrigerated beverage vending machine means a self-contained product that is designed to accept consumer payments and dispense refrigerated beverages in bottles, cans or other sealed containers. (distributeur automatique de boissons réfrigérées)
snack and refrigerated beverage vending machine means a self-contained product that
(b)has a vendible capacity of not more than 100 of those beverages. (distributeur automatique de boissons réfrigérées et de collations)
standby mode means a mode into which the product automatically enters during a period of extended inactivity that is capable of reducing its energy consumption by means of the following power states:
(a)a refrigeration power state in which the average temperature of the refrigerated beverages is allowed to rise to 4.4°C; and
V means, in respect of a refrigerated beverage vending machine, its volume, expressed in litres, calculated in accordance with Appendix C to ASHRAE 32.1. (V)
note
Refrigerated Beverage Vending Machines
646.1#
For the purposes of these Regulations, the class of a refrigerated beverage vending machine is one of the following:
(a)Class A, if it is not a combination vending machine and 25% or more of the surface area on the front side of the refrigerated beverage vending machine is transparent;
(b)Class B, if it is not a combination vending machine and less than 25% of the surface area on the front side of the refrigerated beverage vending machine is transparent;
(c)Combination A, if it is a combination vending machine and 25% or more of the surface area on its front side is transparent; and
(d)Combination B, if it is a combination vending machine and less than 25% of the surface area on its front side is transparent.
note
647Energy-using product#
(1)A refrigerated beverage vending machine is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 648, a refrigerated beverage vending machine is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007.
648Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to refrigerated beverage vending machines described in column 1 that are manufactured during the periods set out in column 3.
(2)The refrigerated beverage vending machine complies with the energy efficiency standard if it meets that standard in the following circumstances:
(a)subject to paragraph (b), it is manufactured before January 8, 2019 and tested in accordance with testing procedures established by sections 1 to 7.2 of ASHRAE 32.1 that are applicable to a refrigerated beverage vending machine as defined in section 646, except that the ambient temperature during the testing to determine Edaily must be 23.9°C ± 1°C;
(b)it is manufactured before August 31, 2012, is designed to display and dispense less than 20 discrete types of beverages and is tested in accordance with testing procedures established by sections 1 to 7.2 of ASHRAE 32.1 that are applicable to a refrigerated beverage vending machine as defined in section 646, except that the ambient temperature during the testing to determine the Edaily must be 32.2°C ± 1°C; or
| Column 1 | Column 2 | Column 3Item | Energy-using Product | Energy Efficiency Standard | Period of Manufacture1 | Refrigerated beverage vending machines, other than those that display and dispense 20 or more discrete types of beverages | Edaily ≤ 55% (8.66 + 0.009 × vendible capacity)Must be capable of operating in standby mode | On or after January 1, 2007 and before January 1, 20082 | Refrigerated beverage vending machines, other than those that display and dispense 20 or more discrete types of beverages | Edaily ≤ 45% (8.66 + 0.009 × vendible capacity)Must be capable of operating in standby mode | On or after January 1, 2008 and before August 31, 20123 | Refrigerated beverage vending machines that display and dispense 20 or more discrete types of beverages | Edaily ≤ 55% (8.66 + 0.009 × vendible capacity)Must be capable of operating in standby mode | On or after January 1, 2007 and before August 31, 20124 | Class A refrigerated beverage vending machines | Edaily ≤ 0.00194 × V + 2.56Must be capable of operating in standby mode | On or after August 31, 2012 and before January 8, 20195 | Class B refrigerated beverage vending machines | Edaily ≤ 0.00258 × V + 3.16Must be capable of operating in standby mode | On or after August 31, 2012 and before January 8, 20196 | Class A refrigerated beverage vending machines | Edaily ≤ 0.00184 x V + 2.43 | On or after January 8, 20197 | Class B refrigerated beverage vending machines | Edaily ≤ 0.00184 x V + 2.20 | On or after January 8, 20198 | Combination A combination vending machines | Edaily ≤ 0.00304 x V + 2.66 | On or after January 8, 20199 | Combination B combination vending machines | Edaily ≤ 0.00392 x V + 2.04 | On or after January 8, 2019
note
649Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2, with the testing procedure adjusted in accordance with paragraphs 648(2)(a) and (b), and be provided to the Minister in respect of a refrigerated beverage vending machine described in column 1.Item | Column 1 | Column 2 | Column 3Energy-using Product | Testing Standard | Information1 | Refrigerated beverage vending machines manufactured on or after January 1, 2007 and before August 31, 2012 | Sections 1 to 7.2 of ASHRAE 32.1 | (a)Edaily;(b)vendible capacity; and(c)number of discrete types of beverages that it can display and dispense.2 | Refrigerated beverage vending machines manufactured on or after August 31, 2012 and before January 8, 2019 | Sections 1 to 7.2 of ASHRAE 32.1 | (a)Edaily;(b)if the product is Class A or Class B; and(c)V.3 | Refrigerated beverage vending machines manufactured on or after January 8, 2019 | CSA C804 | (a)Edaily;(b)if the product is Class A, Class B, Combination A, or Combination B;(c)if Edaily was calculated based on the presence of a refrigeration low power mode;(d)if applicable, the lowest application product temperature in degrees Celsius;(e)V; and(f)the percentage of the surface area on the front side that is transparent.note
Snack and Refrigerated Beverage Vending Machines
650Energy-using product#
(1)A snack and refrigerated beverage vending machine is prescribed as an energy-using product.
note
651Energy efficiency standards#
(1)The following energy efficiency standards apply to a snack and refrigerated beverage vending machine:
(a)its Edaily must be less than or equal to 55% (8.66 + 0.009 × vendible capacity); and
(b)it must be capable of operating in standby mode.
(2)A snack and refrigerated beverage vending machine complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by sections 1 to 7.2 of ASHRAE 32.1 that are applicable to a snack and refrigerated beverage vending machine as defined in section 646, except that the ambient temperature during the testing to determine Edaily must be 23.9°C ± 1°C.
652Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with ASHRAE 32.1, with the testing procedures adjusted in accordance with subsection 651(2), and be provided to the Minister in respect of a snack and refrigerated beverage vending machine:
(a)its Edaily; and
(b)its vendible capacity.
Subdivision C — Ice-Makers
653Definitions#
The following definitions apply in this Subdivision.
CSA C742-08 means the CSA standard CAN/CSA-C742-08 entitled Energy Performance of Automatic Icemakers and Ice Storage Bins. (CSA C742-08)
CSA C742-15 means the CSA standard CAN/CSA-C742-15 entitled Energy Performance of Automatic Icemakers and Ice Storage Bins. (CSA C742-15)
CSA C742-98 means the CSA standard CAN/CSA-C742-98 entitled Performance of Automatic Ice-Makers and Ice Storage Bins. (CSA C742-98)
ice-maker means a factory-assembled automatic ice-maker that has a capacity of at least 23 kg/day (51 pounds per day) but not more than 1 814 kg/day (4,000 pounds per day) and that produces cubed, flaked, crushed or fragmented ice in either a batch or a continuous process. (machine à glaçons)
10 C.F.R. §431.134 means section 431.134 of Subpart H, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.134)
note
654Energy-using product#
(1)An ice-maker is prescribed as an energy-using product.
655Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to ice-makers described in column 1 that are manufactured during the periods set out in column 4.
(2)An ice-maker complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to an ice-maker as defined in section 653. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Ice-makers that have a capacity of ≥ 23 kg/day (51 lbs/day) but ≤ 1 000 kg/day (2,200 lbs/day) | CSA C742-98 | CSA C742-98, Table 2 | On or after December 31, 1998 and before January 1, 20082 | Ice-makers that have a capacity of ≥ 23 kg/day (51 lbs/day) but ≤ 1 000 kg/day (2,200 lbs/day) and that produce ice in a continuous process | CSA C742-98 | CSA C742-98, Table 2, categories “Continuous automatic ice-makers” and “Ice storage bins” | On or after January 1, 2008 and before January 28, 20183 | Ice-makers that have a capacity of ≥ 23 kg/day (51 lbs/day) but ≤ 1 000 kg/day (2,200 lbs/day) and that produce ice in a batch process | CSA C742-08 | CSA C742-08, Tables 2 and 3 | On or after January 1, 2008 and before January 28, 20184 | Ice-makers | CSA C742-15 or 10 C.F.R. §431.134 | CSA C742-15, Tables 3 to 5 | On or after January 28, 2018
note
656Information#
For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an ice-maker described in column 1. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Ice-makers manufactured on or after December 31, 1998 and before January 1, 2008 | CSA C742-98 | (a)ice-making capacity, in kg/day;(b)configuration of product, namely, one cabinet or split system;(c)ice-making process, namely batch process or continuous process;(d)condensing unit type, namely, air-cooled or water-cooled; and(e)input energy rating, in kJ/kg (kWh/100 lbs) of ice.2 | Ice-makers manufactured on or after January 1, 2008 and before January 28, 2018 | CSA C742-98 for ice-makers that produce ice in a continuous processCSA C742-08 for ice-makers that produce ice in a batch process | (a)ice-making capacity, in kg/day;(b)configuration of product, namely,(i)ice-making mechanism and condenser are combined in single package,(ii)self-contained,(iii)remote condenser but no remote compressor, or(iv)remote condenser and remote compressor;(c)ice-making process, namely, batch process or continuous process;(d)condensing unit type, namely, air-cooled or water-cooled;(e)the input energy rating, in kJ/kg (kWh/100 lbs) of ice; and(f)if product has an ice storage bin, the bin capacity, in kg, and its storage effectiveness, as a percentage.3 | Ice-makers manufactured on or after January 28, 2018 | CSA C742-15 | (a)ice-making capacity, in kg/day;(b)configuration of product, namely,(i)ice-making mechanism and condenser are combined in single package,(ii)self-contained,(iii)remote condenser but no remote compressor, or(iv)remote condenser and remote compressor;(c)ice-making process, namely, batch process or continuous process;(d)condensing unit type, namely, air-cooled or water-cooled;(e)the input energy rating, in kJ/kg (kWh/100 lbs) of ice; and(f)if product has an ice storage bin, the bin capacity, in kg, and its storage effectiveness, as a percentage.note
Subdivision D — Walk-in Freezer and Walk-in Cooler Components
Interpretation
657Definitions#
The following definitions apply in this Subdivision.
Add represents, with respect to display door assemblies, the surface area in m2 (square feet). (App)
And represents, with respect to a door assembly other than a display door assembly, the surface area in m2 (square feet). (Apa)
annual walk-in energy factor means the ratio of total heat removed from an enclosed space, excluding heat generated by the operation of the walk-in refrigeration system, to the total energy input of the walk-in refrigeration system during a one-year period, expressed in watt-hours per watt-hours. (facteur énergétique annuel de la chambre froide)
dedicated condensing refrigeration system means a dedicated condensing unit, a single-package dedicated system or a matched refrigeration system. (unité de condensation dédié)
dedicated condensing unit means a positive displacement condensing unit that
(b)is designed to serve one refrigerated load. (unité de condensation dédiée)
(c)[Repealed, SOR/2019-163, s. 49] (repealed)
display door assembly means a walk-in door assembly that is designed for product display and that has 75% or more of its surface area composed of glass or other transparent material. (assemblage de porte de présentation)
envelope means
(a)the portion of a walk-in cooler or walk-in freezer that isolates the interior, refrigerated environment from the ambient, external environment; and
(b)all energy-consuming components of the walk-in cooler or walk-in freezer that are not part of its refrigeration system. (enveloppe)
floor panel means a walk-in panel that is installed, or designed to be installed, as the floor of a walk-in freezer. (panneau de plancher)
freight door assembly means a walk-in door assembly, other than a display door assembly, that is 1.22 m (4 feet) or more in width and 2.44 m (8 feet) or more in height. (assemblage de porte de quai de chargement)
matched refrigeration system means a refrigeration system that includes a dedicated condensing unit and one or more unit coolers with which it is sold. (système de réfrigération apparié)
Net Refrigeration Capacity or (qnet) is the net refrigeration capacity available for space and product cooling. (puissance frigorifique nette ou qnet)
passage door assembly means a walk-in door assembly that is not a display door assembly or a freight door assembly. (assemblage de porte de passage)
RSI-value means, in respect of a walk-in panel and a walk-in door assembly, its thermal resistance, in square metre kelvins per watt (m²·K/W). (valeur-RSI)
R-value means, in respect of a walk-in panel and a walk-in door assembly, its thermal resistance, expressed in square foot Fahrenheit per Btu/h (ft2·°F·h/Btu). (valeur-R)
single-package dedicated system means a single-package refrigeration system that has
(b)components by which heat is transferred from air to refrigerant without any components that are external to the system imposing resistance to the flow of the refrigerated air. (système dédié monobloc)
structural panel means a walk-in panel that is installed, or is designed to be installed, as the ceiling or a wall of a walk-in cooler or walk-in freezer. (panneau de structure)
10 C.F.R. Appendix A means Appendix A to Subpart R, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of the Components of Envelopes of Walk-In Coolers and Walk-In Freezers, as amended from time to time. (appendice A 10 C.F.R.)
10 C.F.R. Appendix B means Appendix B to Subpart R, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of R-Value for Envelope Components of Walk-In Coolers and Walk-In Freezers, as amended from time to time. (appendice B 10 C.F.R.)
10 C.F.R. Appendix C means Appendix C to Subpart R, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Net Capacity and AWEF of Walk-In Cooler and Walk-In Freezer Refrigeration Systems, as amended from time to time. (appendice C 10 C.F.R.)
10 C.F.R. §431.304 means section 431.304 of Subpart R, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.304)
unit cooler means an assembly that includes a means for forced air circulation and elements by which heat is transferred from air to refrigerant without any element external to the cooler imposing air resistance. (refroidisseur d’air)
walk-in cooler means an enclosed storage space that has an area of less than 278.71 m2 (3,000 square feet) and is designed to be cooled to temperatures at or above 0°C and to allow a person to enter, but does not include a walk-in cooler that is designed and marketed exclusively for medical, scientific or research purposes. (réfrigérateur-chambre)
walk-in door assembly means an assembly that is installed, or is designed to be installed, in an opening of an interior or exterior wall of a walk-in cooler or walk-in freezer in order to allow access through the opening or to close it off and that consists of the framing material necessary for its attachment and a moveable door panel, including any glass, door plugs or mullions, but does not include a walk-in door assembly that is designed and marketed exclusively for medical, scientific or research purposes. (assemblage de porte de chambre froide)
walk-in freezer means an enclosed storage space that has an area of less than 278.71 m2 (3000 square feet) and is designed to be cooled to temperatures below 0°C and to allow a person to enter, but does not include a walk-in freezer that is designed and marketed exclusively for medical, scientific or research purposes. (congélateur-chambre)
walk-in panel means a panel that is installed, or is designed to be installed, as part of the envelope of a walk-in cooler or walk-in freezer, but does not include a walk-in door assembly or a walk-in panel that is designed and marketed exclusively for medical, scientific or research purposes. (panneau de chambre froide)
walk-in process cooling refrigeration system means a refrigeration system that
(a)is sold as a set with an insulated enclosure and, when assembled with the enclosure, has a cooling capacity of at least 1.035 kW/m3 (100 Btu/h/ft3) of enclosed internal volume;
(b)is a unit cooler — or a dedicated condensing unit exclusively sold as a set that has a dedicated condensing unit and a unit cooler — that has an evaporator coil with a means of forced air circulation and a height that is
(i)at least 1.37 metres (4.5 feet), as measured perpendicular to the tubes, and
(ii)at least one and a half times the width, as measured parallel to the tubes; or
(c)is sold as a set that has a dedicated condensing unit and an evaporator coil that does not have a means of forced air circulation. (système de réfrigération de type chambre pour refroidissement industriel)
walk-in refrigeration system means a refrigeration system that is installed, or that is designed to be installed, in a walk-in cooler or walk-in freezer and has a unit cooler or a dedicated condensing refrigeration system. It includes all controls and other components that are integral to its operation but does not include a walk-in process cooling refrigeration system or a walk-in refrigeration system that is designed and marketed exclusively for medical, scientific or research purposes. (système de réfrigération de chambre froide)
note
Nameplate
658Nameplate required#
(1)Every walk-in door assembly and walk-in panel that is manufactured on or after June 26, 2017 must be labelled with a nameplate that is attached to the outside of the product in a location that is readily visible prior to assembly of the walk-in cooler or walk-in freezer and that sets out the following information in English and French:
(a)the brand name or manufacturer of the product; and
(b)a statement indicating whether the product is intended for use in a walk-in cooler, walk-in freezer or both.
(2)Every walk-in cooler dedicated condensing refrigeration system that is manufactured on or after January 1, 2020 and every walk-in refrigeration system that is manufactured on or after July 10, 2020 must be labelled with a nameplate that is attached to the outside of the product in a location that is readily visible prior to assembly of the walk-in cooler or the walk-in freezer and that sets out the following information in English and French:
(a)the brand name or manufacturer of the product;
(b)a statement indicating whether the product is intended for use in a walk-in cooler, walk-in freezer or both;
(c)the model number;
(d)the product’s date of manufacture, if it is not included in the model number; and
(e)a statement indicating that the product is for indoor use only, if applicable.
(3)For matched refrigeration systems, the statement referred to in paragraph (2)(e) must appear on the dedicated condensing unit.
note
Walk-in Door Assemblies
659Energy-using product#
(1)A walk-in door assembly is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 660, a walk-in door assembly is not considered to be an energy-using product unless it is manufactured on or after June 5, 2017.
note
660Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to walk-in door assemblies described in column 1 that are manufactured on or after June 5, 2017.
(2)A walk-in door assembly complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a walk-in door assembly as defined in section 657. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Energy Efficiency Standard1 | Display door assemblies for walk-in coolers | 10 C.F.R. Appendix A | Edaily ≤ 0.4306 × Add + 0.41 (0.04 × Add+ 0.41)2 | Display door assemblies for walk-in freezers | 10 C.F.R. Appendix A | Edaily ≤ 1.6146 × Add + 0.29 (0.15 × Add+ 0.29)3 | Freight door assemblies for walk-in coolers | 10 C.F.R. Appendix A for Edaily10 C.F.R. Appendix B for RSI-value (R-value) | Edaily ≤ 0.4306 × And + 1.9 (0.04 × And + 1.9)RSI-value ≥ 4.40 m²·K/W (25 ft²·°F h/Btu)4 | Freight door assemblies for walk-in freezers | 10 C.F.R. Appendix A for Edaily10 C.F.R. Appendix B for RSI-value (R-value) | Edaily ≤ 1.2917 × And + 5.6 (0.12 × And + 5.6)RSI-value ≥ 5.64 m²·K/W (32 ft²·°F h/Btu)5 | Passage door assemblies for walk-in coolers | 10 C.F.R. Appendix A for Edaily10 C.F.R. Appendix B for RSI-value (R-value) | Edaily ≤ 0.5382 × And + 1.7 (0.05 × And + 1.7)RSI-value ≥ 4.40 m²·K/W (25 ft²·°F h/Btu)6 | Passage door assemblies for walk-in freezers | 10 C.F.R. Appendix A for Edaily10 C.F.R. Appendix B for RSI-value (R-value) | Edaily ≤ 1.5069 × And + 4.8 (0.14 × And + 4.8)RSI-value ≥ 5.64 m²·K/W (32 ft²·°F h/Btu)
note
661Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. §431.304 and provided to the Minister in respect of a walk-in door assembly:
(a)its Edaily;
(b)information that indicates whether it is a display door assembly, freight door assembly or passage door assembly;
(c)information that indicates whether it is for use with a walk-in cooler or walk-in freezer; and
(d)if the product is a freight door assembly or passage door assembly, its RSI-value (R-value).
note
Walk-in Panels
662Energy-using product#
(1)A walk-in panel is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 663, a walk-in panel is not considered to be an energy-using product unless it is manufactured on or after June 5, 2017.
note
663Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to walk-in panels described in column 1 that are manufactured on or after June 5, 2017.
(2)A walk-in panel complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix B that are applicable to a walk-in panel as defined in section 657. | Column 1 | Column 2Item | Energy-using Product | Energy Efficiency Standard1 | Structural panels for walk-in coolers | RSI-value ≥ 4.40 m²·K/W (25 ft²·°F h/Btu)2 | Structural panels for walk-in freezers | RSI-value ≥ 5.64 m²·K/W (32 ft²·°F h/Btu)3 | Floor panels | RSI-value ≥ 4.93 m²·K/W (28 ft²·°F h/Btu)
note
664Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix B and provided to the Minister in respect of a walk-in panel:
(a)its RSI-value (R-value),
(b)information that indicates whether it is a structural panel or floor panel; and
(c)if it is a structural panel, information that indicates whether it is for use with a walk-in cooler or walk-in freezer.
note
Walk-in Refrigeration Systems
665Energy-using product#
(1)A walk-in refrigeration system is prescribed as an energy-using product.
(2)However, a walk-in refrigeration system is not considered to be an energy-using product for the purposes of sections 4, 5 and 666 unless
(a)it is a walk-in cooler dedicated condensing refrigeration system manufactured on or after January 1, 2020;
(b)it is a walk-in freezer dedicated condensing refrigeration system manufactured on or after July 10, 2020; or
(c)it is a walk-in cooler or walk-in freezer unit cooler manufactured on or after July 10, 2020.
note
666Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to walk-in refrigeration systems described in column 1 that are manufactured during the periods set out in column 3.
(2)A walk-in refrigeration system complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix C that are applicable to a walk-in refrigeration system as defined in section 657.Item | Column 1 | Column 2 | Column 3Energy-using Product | Energy Efficiency Standard | Period of Manufacture1 | Walk-in cooler dedicated condensing refrigeration systems for use indoors | Annual walk-in energy factor ≥ 1.644 W-h/W-h (5.61 Btu/W-h) | On or after January 1, 20202 | Walk-in cooler dedicated condensing refrigeration systems for use outdoors | Annual walk-in energy factor ≥ 2.227 W-h/W-h (7.60 Btu/W-h) | On or after January 1, 20203 | Walk-in freezer dedicated condensing refrigeration systems for use indoors with a net refrigeration capacity of < 1900 W (6,500 Btu/h) | Annual walk-in energy factor ≥ 9.091 x 10-5 x qnet + 0.530 W-h/W-h (9.091 x 10-5 x qnet+ 1.81 Btu/W-h) | On or after July 10, 20204 | Walk-in freezer dedicated condensing refrigeration systems for use indoors with a net refrigeration capacity of ≥ 1900 W (6,500 Btu/h) | Annual walk-in energy factor ≥ 0.703 W-h/W-h (2.40 Btu/W-h) | On or after July 10, 20205 | Walk-in freezer dedicated condensing refrigeration system for use outdoors with a net refrigeration capacity of < 1900 W (6,500 Btu/h) | Annual walk-in energy factor ≥ 6.522 x 10-5 x qnet + 0.800 W-h/W-h (6.522 x 10-5 x qnet + 2.73 Btu/W-h) | On or after July 10, 20206 | Walk-in freezer dedicated condensing refrigeration systems for use outdoors with a net refrigeration capacity of ≥ 1900 W (6,500 Btu/h) | Annual walk-in energy factor ≥ 0.923 W-h/W-h (3.15 Btu/W-h) | On or after July 10, 20207 | Walk-in cooler unit coolers with a fan motor that operates using direct current or has a nominal voltage of not more than 480 V AC | Annual walk-in energy factor ≥ 2.638 W-h/W-h (9.00 Btu/W-h) | On or after July 10, 20208 | Walk-in freezer unit coolers with a fan motor that operates using direct current or has a nominal voltage of not more than 480 V AC and with a net refrigeration capacity of < 4540 W (15,500 Btu/h) | Annual walk-in energy factor ≥ 1.575 x 10-5 x qnet + 1.146 W-h/W-h (1.575 x 10-5 x qnet + 3.91 Btu/W-h) | On or after July 10, 20209 | Walk-in freezer unit coolers with a fan motor that operates using direct current or has a nominal voltage of not more than 480 V AC and with a net refrigeration capacity of ≥ 4540 W (15,500 Btu/h) | Annual walk-in energy factor ≥ 1.216 W-h/W-h (4.15 Btu/W-h) | On or after July 10, 2020
note
667Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix C and provided to the Minister in respect of a walk-in refrigeration system:
(a)its annual walk-in energy factor;
(b)information that indicates whether it is designed and marketed for use indoors, outdoors or both;
(c)information that indicates if it is for use in a walk-in cooler or walk-in freezer;
(d)information that indicates if it has a unit cooler or a dedicated condensing refrigeration system; and
(e)if it is a walk-in freezer unit cooler or dedicated condensing refrigeration system, its net refrigeration capacity expressed in watts.
note
Division 11 — Dry-type Transformers
703Definitions#
The following definitions apply in this Division.
CSA C802.2 means the CSA standard CAN/CSA-C802.2-00 entitled Minimum Efficiency Values for Dry-Type Transformers. (CSA C802.2)
CSA C802.2-12 means the CSA standard CAN/CSA-C802.2-12 entitled Minimum efficiency values for dry-type transformers. (CSA C802.2-12)
dry-type transformer means a transformer whose core and windings are in a gaseous or dry compound insulating medium and that is either single-phase with a nominal power of 15 to 833 kVA or three-phase with a nominal power of 15 to 7 500 kVA, has a nominal frequency of 60 Hz and has a high voltage winding of 35 kV or less. It does not include any of the following:
(a)an autotransformer;
(b)a drive (isolation) transformer that has two or more output windings or a nominal low-voltage line current of more than 1 500 A;
(c)a grounding transformer;
(d)a rectifier transformer;
(e)a sealed transformer;
(f)a non-ventilated transformer;
(g)a testing transformer;
(h)a furnace transformer;
(i)a welding transformer;
(j)a special impedance transformer;
(k)a transformer that has a nominal low-voltage line current of 4 000 A or more;
(l)an on-load regulating transformer;
(m)a resistance grounding transformer; or
(n)a transformer that is in a voltage class greater than 1.2 kV and that has a BIL of less than 20 kV or more than 199 kV. (transformateur à sec)
10 C.F.R. Appendix A means Appendix A to Subpart K, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Distribution Transformers, as amended from time to time. (appendice A 10 C.F.R.)
transformer means a static-electric device that consists of two or more coils of insulated wire, together with the necessary accessories, and that transfers alternating current by electromagnetic induction from one coil to another to change the original voltage. (transformateur)
note
704Energy-using product#
(1)A dry-type transformer is prescribed as an energy-using product.
(2)However, a dry-type transformer is not considered to be an energy-using product
(b)for the purpose of section 705, if it has a BIL of more than 150 kV and was manufactured before January 1, 2010.
705Energy efficiency standards — manufactured before January 1, 2016#
(1)In respect of dry-type transformers that were manufactured on or after January 1, 2005 and before January 1, 2016, the energy efficiency standards set out in column 2 of the table to this section apply to dry-type transformers that were manufactured during the periods set out in column 3.
(2)A dry-type transformer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard referred to in column 1 that are applicable to a dry-type transformer as defined in section 703. | Column 1 | Column 2 | Column 3Item | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | CSA C802.2 | CSA C802.2, Table 1 | On or after January 1, 2005 and before January 1, 20102 | CSA C802.2-12 | CSA C802.2-12, Table 1 | On or after January 1, 2010 and before January 1, 2016
note
705.1Energy efficiency standard — single-phase and 1.2 kV voltage class#
(1)In respect of dry-type transformers that are single-phase, in the 1.2 kV voltage class and manufactured on or after January 1, 2016, the energy efficiency standards set out in column 2 of Table 1 to this section apply to dry-type transformers that have a kVA rating described in column 1.
(2)In respect of dry-type transformers that are single-phase, in a voltage class greater than 1.2 kV and manufactured on or after January 1, 2016, the energy efficiency standards that are set out in relation to the product’s BIL rating set out in column 2 of Table 2 to this section apply to dry-type transformers that have a kVA rating set out in column 1.
(3)For the purposes of subsections (1) and (2), if the kVA rating of the product falls between the kVA ratings set out in two consecutive items in column 1 of the applicable table to this section, the energy efficiency standard for the product is an interpolation of the corresponding energy efficiency standards set out in column 2.
(4)A dry-type transformer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix A that are applicable to a dry-type transformer as defined in section 703. | Column 1 | Column 2Item | kVA Rating | % Efficiency When Tested at 35% of Nominal Load1 | 15.0 | 97.702 | 25.0 | 98.003 | 37.5 | 98.204 | 50.0 | 98.305 | 75.0 | 98.506 | 100.0 | 98.607 | 167.0 | 98.708 | 250.0 | 98.809 | 333.0 | 98.90 | Column 1 | Column 2Item | kVA Rating | % Efficiency When Tested at 50% of Nominal Load20-45 kV BIL | > 45-95 kV BIL | > 95-199 kV BIL1 | 15.0 | 98.10 | 97.86 | 97.602 | 25.0 | 98.33 | 98.12 | 97.903 | 37.5 | 98.49 | 98.30 | 98.104 | 50.0 | 98.60 | 98.42 | 98.205 | 75.0 | 98.73 | 98.57 | 98.536 | 100.0 | 98.82 | 98.67 | 98.637 | 167.0 | 98.96 | 98.83 | 98.808 | 250.0 | 99.07 | 98.95 | 98.919 | 333.0 | 99.14 | 99.03 | 98.9910 | 500.0 | 99.22 | 99.12 | 99.0911 | 667.0 | 99.27 | 99.18 | 99.1512 | 833.0 | 99.31 | 99.23 | 99.20
note
705.2Energy efficiency standards — three-phase and 1.2 kV voltage class#
(1)In respect of dry-type transformers that are three-phase, in the 1.2 kV voltage class and manufactured on or after January 1, 2016, the energy efficiency standards set out column 2 of Table 1 to this section apply to dry-type transformers that have a kVA rating set out in column 1.
(2)In respect of dry-type transformers that are three-phase, in a voltage class greater than 1.2 kV and manufactured on or after January 1, 2016, the energy efficiency standards that are set out in relation to the product’s BIL rating set out in column 2 of Table 2 to this section apply to dry-type transformers that have a kVA rating set out in column 1.
(3)For the purposes of subsections (1) and (2), if the kVA rating of the product falls between the kVA ratings set out in two consecutive items in column 1 of the applicable table to this section, the energy efficiency standard for the product is an interpolation of the corresponding energy efficiency standards set out in column 2.
(4)The energy efficiency standard that is applicable to a dry-type transformer under this section is reduced by 0.11 if the transformer has multiple high-voltage windings and a voltage ratio other than 2:1.
(5)A dry-type transformer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix A that are applicable to a dry-type transformer as defined in section 703. | Column 1 | Column 2Item | kVA Rating | % Efficiency When Tested at 35% of Nominal Load1 | 15.0 | 97.892 | 30.0 | 98.233 | 45.0 | 98.404 | 75.0 | 98.605 | 112.5 | 98.746 | 150.0 | 98.837 | 225.0 | 98.948 | 300.0 | 99.029 | 500.0 | 99.1410 | 750.0 | 99.2311 | 1 000.0 | 99.28 | Column 1 | Column 2Item | kVA Rating | % Efficiency When Tested at 50% of Nominal Load20-45 kV BIL | > 45-95 kV BIL | > 95-199 kV BIL1 | 15.0 | 97.50 | 97.18 | 96.802 | 30.0 | 97.90 | 97.63 | 97.303 | 45.0 | 98.10 | 97.86 | 97.604 | 75.0 | 98.33 | 98.13 | 97.905 | 112.5 | 98.52 | 98.36 | 98.106 | 150.0 | 98.65 | 98.51 | 98.207 | 225.0 | 98.82 | 98.69 | 98.578 | 300.0 | 98.93 | 98.81 | 98.699 | 500.0 | 99.09 | 98.99 | 98.8910 | 750.0 | 99.21 | 99.12 | 99.0211 | 1 000.0 | 99.28 | 99.20 | 99.1112 | 1 500.0 | 99.37 | 99.30 | 99.2113 | 2 000.0 | 99.43 | 99.36 | 99.2814 | 2 500.0 | 99.47 | 99.41 | 99.3315 | 3 000.0 | 99.47 | 99.41 | 99.3316 | 3 750.0 | 99.47 | 99.41 | 99.3317 | 5 000.0 | 99.47 | 99.41 | 99.3318 | 7 500.0 | 99.48 | 99.41 | 99.39
note
706Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a dry-type transformer:
(a)if applicable, information that indicates whether the transformer is in the 1.2 kV voltage class;
(b)its BIL rating;
(c)if applicable, information that indicates whether the transformer is a three-phase transformer that has multiple high-voltage windings and a voltage ratio other than 2:1;
(d)its kVA rating;
(e)its phase — namely, single-phase or three-phase;
(f)the tested efficiency, expressed as a percentage;
(h)if it is manufactured on or after January 1, 2010, the impedance, expressed as a percentage.
(2)The information must be collected in accordance with one of the following standards:
(a)CSA C802.2-12, if the product was manufactured on or after January 1, 2005 and before January 1, 2016; or
(b)10 C.F.R. Appendix A, if the product is manufactured on or after January 1, 2016.
note
Division 12 — Motors
Definitions
748Definitions#
The following definitions apply in this Division.
CSA C390-10 means the CSA standard CSA C390-10 entitled Test methods, marking requirements, and energy efficiency levels for three-phase induction motors. (CSA C390-10)
IEC 60034-2-1 means the IEC standard CEI/IEC 60034-2-1 entitled Rotating electrical machines – Part 2-1: Standard methods for determining losses and efficiency from tests (excluding machines for traction vehicles). (CEI 60034-2-1)
IEEE 112 means the IEEE standard IEEE 112 entitled Standard Test Procedure for Polyphase Induction Motors and Generators. (IEEE 112)
note
Subdivision A — Electric Motors
749Definitions#
The following definitions apply in this Subdivision.
CSA C390-10 [Repealed, SOR/2022-265, s. 42]
electric motor means a machine that converts electrical power into rotational mechanical power and that
(a)is an electric three-phase induction design;
(b)is one of the following designs:
(i)a NEMA design A, B or C with a three- or four-digit NEMA frame number,
(ii)an enclosed NEMA design A, B or C with a NEMA frame number of 56, or
(iii)an IEC design N or H with an IEC frame number of 80 or above;
(c)has a nominal output power of not less than 0.75 kW (1 horsepower) and not more than 375 kW (500 horsepower);
(d)has a cage or squirrel-cage design;
(e)is rated for continuous duty or S1 operation;
(f)is designed to operate at a single speed;
(g)has a nominal voltage of not more than 600 V AC;
(h)has a nominal frequency of 50 Hz, 50/60 Hz or 60 Hz;
(i)has a two-, four-, six- or eight-pole construction;
(j)has an open or enclosed construction; and
(k)has an IP code from 00 to 67.
(l)a motor that is cooled by air that is forced over the motor by a fan or blower that is not an integral part of the motor;
(m)a liquid-cooled motor;
(n)an inverter-only motor; or
(o)a motor that is designed to operate continuously only while immersed. (moteur électrique)
It does not include any of the following:
explosion-proof motor means an electric motor
(a)in respect of which measures have been taken to prevent excessive temperatures and the production of arcs or sparks by the motor; or
(b)that is encased in an enclosure that can withstand the explosion of any flammable gas or vapour that might enter it, without being damaged and without transmitting the explosion to the outside. (moteur antidéflagrant)
footless means, in respect of an electric motor, that it does not have feet or detachable feet or that it is not designed to receive detachable feet. (sans pieds)
IEC 60034-5 means the IEC standard CEI/IEC 60034-5: 2006 entitled Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electric machines (IP code) - Classification. (CEI 60034-5)
IEC 60529 means the IEC standard CEI/IEC 60529: 2013 entitled Degrees of Protection Provided by Enclosures (IP Code). (CEI 60529)
IEEE 112-2004 [Repealed, SOR/2022-265, s. 42]
integral gear assembly means a product that consists of an electric motor and a gear mechanism that are combined in such a manner that
(b)if the motor and the gear mechanism are separated, only one of them remains intact. (assemblage d’engrenages intégrés)
IP code means the classification of the degree of protection provided by an enclosure, as set out in IEC 60034-5, IEC 60529 or NEMA MG-1. (code IP)
NEMA MG-1 means the NEMA standard MG 1 entitled NEMA MG 1 Motors and Generators. (NEMA MG-1)
note
750Energy-using product#
(1)An electric motor is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5, 751 and 752, an electric motor is not considered to be an energy-using product if
(a)it was manufactured before February 3, 1995;
(b)it was manufactured before November 27, 1999 and is an explosion-proof motor or is part of an integral gear assembly;
(c)it was manufactured before January 1, 2011 and it
(i)has an eight-pole construction,
(ii)has NEMA U frame dimensions,
(iii)is a NEMA design C or an IEC design H,
(iv)is a close-coupled pump motor,
(v)is a vertically mounted solid shaft normal thrust motor,
(vi)is a fire-pump motor or other NEMA design B motor with a nominal output power of more than 150 kW (200 horsepower) or is an IEC design N motor with a nominal output power of more than 150 kW (200 horsepower), or
(vii)is footless;
(d)it was manufactured before June 1, 2016 and it
(i)is a NEMA design A with a nominal output power of more than 150 kW (200 horsepower),
(ii)is an enclosed NEMA design with a NEMA frame number of 56,
(iii)has NEMA frame dimensions other than T or U,
(iv)has an IEC frame number of 80 or more but less than 90,
(v)is a partial electric motor, a brake motor or a vertical hollow shaft motor,
(vi)is designed to operate continuously in free air, but can operate continuously for a period of at least 30 minutes while completely immersed,
(vii)has a separately powered blower,
(viii)has a base, end shields or flanges that are not within the dimensions specified in NEMA MG-1, or
(ix)has a NEMA shaft that is not a standard shaft, R-shaft or S-shaft, as specified in NEMA MG-1; or
(e)it was manufactured before June 1, 2017 and is a medical-imaging motor.
note
751Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to electric motors described in column 1 that are manufactured during the periods set out in column 4.
(2)An electric motor complies with the energy efficiency standard if it meets the standard when tested at 100% of its nominal full load in accordance with testing procedures established by the standard set out in column 2 that are applicable to an electric motor as defined in section 749. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Electric motors that are fire-pump motors | CSA C390-10, IEEE 112 or IEC 60034-2-1 | CSA C390-10, Table 2 | On or after February 3, 19952 | Electric motors that are medical-imaging motors | CSA C390-10, IEEE 112 or IEC 60034-2-1 | NEMA MG-1, Table 12-12 | On or after June 1, 20173 | Electric motors that are part of an integral gear assembly; | CSA C390-10 | CSA C390-10, Table 2 | On or after November 27, 1999 and before June 1, 20164 | Electric motors that are close-coupled pump motors | CSA C390-10 | CSA C390-10, Table 2 | On or after January 1, 2011 and before June 1, 20165 | Electric motors that are vertically-mounted solid shaft normal thrust motors | CSA C390-10 | CSA C390-10, Table 2 | On or after January 1, 2011 and before June 1, 20166 | Electric motors that(a)have an eight-pole construction;(b)have NEMA U frame dimensions;(c)are a NEMA design C or an IEC design H;(d)have a nominal output power of more than 150 kW (200 HP) and are a NEMA design B or an IEC design N; or(e)are footless. | CSA C390-10 | CSA C390-10, Table 2 | On or after January 1, 2011 and before June 1, 20167 | Electric motors other than motors described in items 1 to 6 | CSA C390-10 | CSA C390-10, Table 3 | On or after February 3, 1995 and before June 1, 20168 | Electric motors other than fire-pump motors or medical-imaging motors | CSA C390-10, IEEE 112 or IEC 60034-2-1 | NEMA MG-1, Table 12-12 | On or after June 1, 2016
note
752Information#
For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of an electric motor:
(a)in respect of an electric motor for which a unique motor identifier was not provided under paragraph 5(1)(c),
(i)its nominal output power, expressed in kilowatts (horsepower),
(ii)the number of poles, and
(iii)its construction — namely, open construction or enclosed construction; and
(b)in respect of an electric motor described in column 1 of the table to this section, the information set out in column 3, which must be collected in accordance with the standard set out in column 2.
| Column 1 | Column 2 | Column 3Item | Energy-using Product | Testing Standard | Information1 | Electric motors manufactured on or after February 3, 1995 and before June 1, 2016 | CSA C390-10 | (a)nominal efficiency value;(b)NEMA or IEC design of motor;(c)frame type;(d)motor configuration, namely, close-coupled pump motor, vertically mounted solid shaft normal thrust motor, fire-pump motor or motor that is part of an integral gear assembly;(e)shaft type;(f)mounting type; and(g)motor configuration, namely, footless, with feet or with detachable feet.2 | Electric motors manufactured on or after June 1, 2016 | CSA C390-10, IEEE 112 or IEC 60034-2-1 | (a)nominal efficiency value;(b)NEMA or IEC design of motor; and(c)motor configuration, namely, fire-pump motor, medical-imaging motor or another configuration.note
Subdivision B — Small Electric Motors
753Definitions#
The following definitions apply in this Subdivision.
CSA C747-09 means the CSA standard CSA C747-09 entitled Energy efficiency test methods for small motors. (CSA C747-09)
IEEE 114-2010 means the IEEE standard IEEE 114-2010 entitled IEEE Standard Test Procedure for Single-Phase Induction Motors. (IEEE 114-2010)
small electric motor means a machine that converts electrical power into rotational mechanical power and that
(a)has a nominal output power of not less than 0.18 kW (0.25 horsepower) and not more than 2.2 kW (3 horsepower);
(b)is a NEMA design with a two-digit frame number or an IEC design with a frame number of 63 or 71;
(c)has a nominal frequency of 50/60 Hz or 60 Hz;
(d)has a two-, four- or six-pole construction;
(e)operates using alternating current;
(f)is one of the following types, namely, capacitor-start capacitor-run, capacitor-start induction-run or polyphase;
(g)has an open construction;
(h)is rated for continuous duty or S1 operation;
(i)is designed to operate at a single speed; and
(j)is designed as a general purpose motor.
It does not include a split-phase motor, shaded pole motor or permanent split-capacitor motor. (petit moteur électrique)
10 C.F.R. §431.446 means section 431.446 of Subpart X, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.446)
note
754Energy-using product#
(1)A small electric motor is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 755, a small electric motor is not considered to be an energy-using product if it was manufactured before March 9, 2015 or it is incorporated into any other product that is subject to these Regulations.
note
755Energy efficiency standards#
(1)The energy efficiency standards set out in the applicable table in paragraph (a) of 10 C.F.R. §431.446 apply to a small motor.
(2)A small electric motor complies with the energy efficiency standard if it meets that standard when
(a)the product’s average full load efficiency is determined using horsepower and kilowatt ratings that are determined in accordance with paragraph (b) of 10 C.F.R. §431.446;
(b)the product is tested at 100% of its nominal full load; and
(c)the product is tested in accordance with testing procedures established by one of the following standards that are applicable to a small electric motor as defined in section 753:
(i)if the motor is polyphase and has a nominal output power ≥ 0.18 kW (0.25 horsepower) but ≤ 0.75 kW (1 horsepower), CSA C747-09, IEEE 112 (Test Method A) or IEC 60034-2-1 (Test Method 2-1-1A),
(ii)if the motor is polyphase and has a nominal output power > 0.75 kW (1 horsepower) but ≤ 2.2 kW (3 horsepower), CSA C390-10, IEEE 112 (Test Method B) or IEC 60034-2-1 (Test Method 2-1-1B), or
(iii)if the motor is capacitor-start capacitor-run or capacitor-start induction-run, CSA C747-09, IEEE 114-2010 or IEC 60034-2-1 (Test Method 2-1-1A).
note
756Information#
(1)For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a small electric motor:
(a)its average full load efficiency;
(b)its type, namely, capacitor-start capacitor-run, capacitor-start induction-run or polyphase; and
(c)if the motor is one for which a unique motor identifier has not been provided under paragraph 5(1)(c), its nominal output power expressed in kilowatts (horsepower) and the number of poles.
(2)The information must be collected in accordance with one of the following standards:
(a)if the motor is polyphase and has a nominal output power ≥ 0.18 kW (0.25 horsepower) but ≤ 0.75 kW (1 horsepower), CSA C747-09, IEEE 112 (Test Method A) or IEC 60034-2-1 (Test Method 2-1-1A);
(b)if the motor is polyphase and has a nominal output power > 0.75 kW (1 horsepower) but ≤ 2.2 kW (3 horsepower), CSA C390-10, IEEE 112 (Test Method B) or IEC 60034-2-1 (Test Method 2-1-1B); or
(c)if the motor is capacitor-start capacitor-run or capacitor-start induction-run, CSA C747-09, IEEE 114-2010 or IEC 60034-2-1 (Test Method 2-1-1A).
note
Division 13 — Plumbing Supply Fittings
799Definition of 10 C.F.R. Appendix S#
In this Division, 10 C.F.R. Appendix S means Appendix S to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads, as amended from time to time.note
Subdivision A — Commercial Pre-Rinse Spray Valves
800Definitions#
The following definitions apply in this Subdivision.
commercial pre-rinse spray valve means a handheld device for spraying water on food service items, that has a release-to-close valve and is designed and marketed to be used in conjunction with commercial dishwashing or commercial ware washing equipment. (pulvérisateur de prérinçage commercial)
10 C.F.R. §431.264 means the test method set out in section 431.264 of Subpart O, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.264)
10 C.F.R. §431.266 means the table to paragraph 431.266(b) of Subpart O, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.266)
note
801Energy-using product#
(1)A commercial pre-rinse spray valve is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 802, a commercial pre-rinse spray valve is not considered to be an energy-using product unless it is manufactured on or after June 27, 2016.
note
802Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to commercial pre-rinse spray valves described in column 1 that are manufactured during the periods set out in column 3.
(2)A commercial pre-rinse spray valve complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. §431.264 that are applicable to a commercial pre-rinse spray valve as defined in section 800. | Column 1 | Column 2 | Column 3Item | Energy-using Product | Energy Efficiency Standard | Period of Manufacture1 | Commercial pre-rinse spray valves | Maximum water flow rate ≤ 6.1 L/min (1.6 gallons/min) | On or after June 27, 2016 and before January 28, 20192 | Commercial pre-rinse spray valves that have a spray force ≤ 1.39 N (5.0 ounce-force) | Maximum water flow rate ≤ flow rate for “Product Class 1” commercial pre-rinse spray valve set out in 10 C.F.R. §431.266 | On or after January 28, 20193 | Commercial pre-rinse spray valves that have a spray force > 1.39 N (5.0 ounce-force) but ≤ 2.22 N (8.0 ounce-force) | Maximum water flow rate ≤ flow rate for “Product Class 2” commercial pre-rinse spray valve set out in 10 C.F.R. §431.266 | On or after January 28, 20194 | Commercial pre-rinse spray valves that have a spray force > 2.22 N (8.0 ounce-force) | Maximum water flow rate ≤ flow rate for “Product Class 3” commercial pre-rinse spray valve set out in 10 C.F.R. §431.266 | On or after January 28, 2019
note
803Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. §431.264 and provided to the Minister in respect of a commercial pre-rinse spray valve:
(a)the maximum water flow rate, in litres per minute (gallons per minute); and
(b)if it is manufactured on or after January 28, 2019, the spray force in newtons (ounce-force).
note
Subdivision B — Faucets
803.1Definitions#
The following definitions apply in this Subdivision.
faucet means
(a)a private lavatory faucet;
(b)a replacement aerator for a private lavatory faucet;
(c)a public lavatory faucet;
(d)a replacement aerator for a public lavatory faucet;
(g)a metering faucet.
low-pressure water dispenser means a terminal fitting that dispenses drinking water at a pressure of 105 kPa (15 psi) or less. (distributeur d’eau à basse pression)
pot filler means a terminal fitting that can accommodate only a single supply water inlet, with an articulated arm or the equivalent that allows the product to reach to fill vessels when in use and allows the product to be retracted when not in use. (robinet remplisseur)
note
803.3Energy efficiency standards#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to faucets described in column 1.
(2)A faucet complies with the energy efficiency standard if it meets that standard when tested in accordance with the applicable testing procedures established by 10 C.F.R. Appendix S. | Column 1 | Column 2Item | Energy-using Product | Energy Efficiency Standard1 | Private lavatory faucets and replacement aerators for private lavatory faucets | Maximum water flow rate ≤ 4.7 L/min (1.2 US gallons/min) measured at 414 kPa (60 psi)2 | Public lavatory faucets — other than metering faucets — and replacement aerators for public lavatory faucets | Maximum water flow rate ≤ 2.0 L/min (0.5 US gallons/min) measured at 414 kPa (60 psi)3 | Kitchen faucets and replacement aerators for kitchen faucets | Maximum water flow rate ≤ 7.0 L/min (1.8 US gallons/min), with optional temporary flow rate ≤ 8.5 L/min (2.2 US gallons/min) measured at 414 kPa (60 psi)4 | Metering faucets | Maximum water flow rate ≤ 0.95 L/cycle (0.25 US gallons/cycle) measured at 414 kPa (60 psi)
note
803.4Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix S and provided to the Minister in respect of a faucet:
(a)its type;
(b)the maximum water flow rate, expressed in litres per cycle (US gallons per cycle) for metering faucets and in litres per minute (US gallons per minute) for other faucets;
(d)the water pressure at which the maximum water flow rate was measured, expressed in kPa (psi).
note
Subdivision C — Showerheads
803.5Definition of showerhead#
In this Subdivision, showerhead means a component or set of components with one or multiple nozzles that is intended for attachment to a single supply fitting for spraying water onto a bather. It does not include a showerhead designed and marketed exclusively for the emergency washing of a person who has been exposed to hazardous materials or a showerhead designed and marketed exclusively for use in health care facilities.note
803.6Energy-using product#
(1)A showerhead is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 803.7, a showerhead is not considered to be an energy-using product unless it is manufactured on or after July 1, 2026.
note
803.7Energy efficiency standard#
(1)The energy efficiency standards set out in column 2 of the table to this section apply to showerheads described in column 1. For showerheads with multiple nozzles, the maximum water flow rate applies regardless of the number of nozzles in use.
(2)A showerhead complies with the energy efficiency standard if it meets that standard when tested in accordance with the applicable testing procedures established by 10 C.F.R. Appendix S.Item | Column 1 | Column 2Energy-using Product | Energy Efficiency Standard1 | Showerheads with one nozzle | Maximum water flow rate ≤ 7.0 L/min (1.8 U.S. gallons/min) measured at 552 kPa (80 psi)2 | Showerheads with multiple nozzles | Maximum water flow rate ≤ 7.0 L/min (1.8 U.S. gallons/min) measured at 552 kPa (80 psi)
note
803.8Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix S and provided to the Minister in respect of a showerhead:
(a)the number of nozzles;
(b)the maximum water flow rate when all nozzles are used, expressed in litres per minute (US gallons per minute); and
(c)the water pressure at which the maximum water flow rate was measured, expressed in kPa (psi).
note
Division 14 — Pumps
Subdivision A — Clean Water Pumps
804Definitions#
The following definitions apply in this subdivision.
10 C.F.R. Appendix A means Appendix A to Subpart Y, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Pumps, as amended from time to time. (appendice A 10 C.F.R.)
10 C.F.R. §431.465(b)(4) means the table to paragraph 431.465(b)(4) of Subpart Y, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.465(b)(4))
best efficiency point means the pump hydraulic power operating point that results in a maximum efficiency. (point de rendement maximal)
clean water means water that has a maximum non-absorbent solid content of 0.25 kg/m3(0.016 lb/ft3), a maximum dissolved solid content of 50 kg/m3 (3.1 lb/ft3) and a total gas content that does not exceed the saturation volume and that may include additives necessary to prevent the water from freezing down to -10°C (14°F). (eau claire)
clean water pump means a pump – with or without mechanical equipment, driver and controls, that is designed for pumping clean water – other than a fire pump, a self-priming pump, a prime-assist pump, a magnet-driven pump, a pump designed to be used in a nuclear facility, a pump designed to Canadian or United States military specifications or a pump designed and marketed for use as a pool pump, that
(a)is one of the following types:
(i)an end suction close-coupled pump with a maximum specific speed of 5000 RPM,
(ii)an end suction frame mounted pump with its own bearings and with a specific speed not more than 5000 RPM,
(iii)an in-line pump,
(iv)a radially split, multi-stage, vertical, in-line diffuser casing pump, or
(v)a submersible turbine pump with a bowl diameter not greater than 152 mm (6 in),
(b)has a shaft input power not less than 0.75 kW (1 horsepower) and not greater than 150 kW (200 horsepower) at best efficiency point and full impeller diameter;
(c)has a flow rate of 5.68 m3/h (25 US gallons/min) or greater at best efficiency point and full impeller diameter;
(d)has a maximum head of 139.9 m (459 ft) at best efficiency point and full impeller diameter;
(f)is designed to operate with either a 2-pole or 4-pole induction motor or a non-induction motor with a nominal speed of rotation of either 1800 RPM or 3600 RPM, as determined in accordance with 10 C.F.R. Appendix A, and in which the driver and impeller rotate at the same speed. (pompe à eau claire)
note
805Energy-using product#
(1)A clean water pump is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 806, a clean water pump is not considered to be an energy-using product unless it is manufactured on or after January 27, 2020.
note
806Energy efficiency standard#
(1)The energy efficiency standard that applies to a clean water pump is the maximum pump energy index set out for the applicable equipment class in 10 C.F.R. §431.465(b)(4).
(2)A clean water pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix A that apply to a clean water pump as defined in section 804.
note
807Information#
For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a clean water pump:
(a)its nominal power in kilowatts;
(b)the impeller diameter in millimetres;
(c)its type, namely, end suction close-coupled pump, end suction frame mounted with own bearings pump, in-line pump, radially split multi-stage, vertical, in-line diffuser casing pump or submersible turbine pump;
(d)its nominal speed of rotation collected in accordance with 10 C.F.R. Appendix A;
(e)its mode of operation, namely, constant load or variable load; and
(f)its pump energy index value collected in accordance with 10 C.F.R. Appendix A.
note
Subdivision B — Pool Pumps
808Definitions#
(1)The following definitions apply in this Subdivision.
10 C.F.R. §431.465(f) means the table to paragraph (f) of section 431.465 of Subpart Y, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.465(f))
10 C.F.R. §431.465(g) means paragraph (g) of section 431.465 of Subpart Y, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.465(g))
10 C.F.R. §431.465(h) means paragraph (h) of section 431.465 of Subpart Y, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.465(h))
10 C.F.R. Appendix C means Appendix C to Subpart Y, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Efficiency of Dedicated-Purpose Pool Pumps, as amended from time to time. (appendice C 10 C.F.R.)
pool pump means, subject to subsection (2), a pump that is designed for use with a pool or spa and that is
(a)a filter pump that has a hydraulic power of less than 1.865 kW (2.5 HP);
(b)a pressure cleaner booster pump;
(c)a waterfall pump with a maximum head less than or equal to 9.144 m (30 ft) and a maximum speed less than or equal to 1800 RPM;
(d)a pump with an integral sand filter;
(e)a pump with an integral cartridge filter;
(f)a pump for a storable electric spa; or
(g)a pump for a rigid electric spa. (pompe de piscine)
(2)The definition pool pump in subsection (1) does not include
(a)a clean water pump;
(b)a circulator pump;
(c)a submersible pump;
(d)a pool filter pump with hydraulic output power equal to or greater than 1.865 kW (2.5 HP); or
(e)a pump marketed exclusively for commercial use that has
(i)an orifice on the pump body that accepts suction side plumbing connections that has an inner diameter greater than 72 mm (2.85 inches), and
(ii)a measured performance greater than or equal to 757 litres per minute (200 US gallons per minute) at 15.24 m (50 feet) of head.
note
809Energy-using product#
(1)A pool pump is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 810, a pool pump is not considered to be an energy-using product unless it is manufactured on or after January 1, 2026.
note
810Energy efficiency standards#
(1)The energy efficiency standards set out in column 3 of the table to this section apply to pool pumps described in column 1.
(2)A pool pump complies with the energy efficiency standard if it meets that standard when tested in accordance with the applicable testing procedures established by the standard, if any, set out in column 2 of the table to this section.Item | Column 1 | Column 2 | Column 3Energy-using Product | Testing Standard | Energy Efficiency Standard1 | Self-priming pool filter pumps that have a single phase electric motor and hydraulic horsepower of 0.711 HP or more but less than 2.5 HP | 10 C.F.R. Appendix C | 10 C.F.R. §431.465(f)10 C.F.R. §431.465(h)2 | Self-priming pool filter pumps that have a single phase electric motor and hydraulic horsepower of less than 0.711 HP | 10 C.F.R. Appendix C | 10 C.F.R. §431.465(f)10 C.F.R. §431.465(h)3 | Non-self-priming pool filter pumps that have hydraulic horsepower of less than 2.5 HP | 10 C.F.R. Appendix C | 10 C.F.R. §431.465(f)10 C.F.R. §431.465(h)4 | Pressure cleaner booster pumps | 10 C.F.R. Appendix C | 10 C.F.R. §431.465(f)10 C.F.R. §431.465(h)5 | Waterfall pumps | 10 C.F.R. Appendix C | 10 C.F.R. §431.465(h)6 | Integral sand filter pool pumps | None | 10 C.F.R. §431.465(g)10 C.F.R. §431.465(h)7 | Integral cartridge filter pool pumps | None | 10 C.F.R. §431.465(g)10 C.F.R. §431.465(h)8 | Storable electric spa pumps | None | 10 C.F.R. §431.465(h)9 | Rigid electric spa pumps | None | 10 C.F.R. §431.465(h)
note
811Information#
For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a pool pump:
(a)its type;
(b)its nominal motor power, expressed in watts;
(c)its nominal hydraulic power, expressed in watts;
(d)its total power, expressed in watts;
(e)in the case of a self-priming pool filter pump, a non-self-priming pool filter pump, a waterfall pump or a pressure cleaner booster pump, its weighted energy factor;
(f)in the case of a pool pump with an integral filter, information that indicates whether it has a separate or built-in timer;
(g)information that indicates whether it has freeze protection controls;
(h)in the case of a pool pump with freeze protection controls, information that indicates whether freeze protection is enabled or disabled; and
(i)in the case of a pool pump with freeze protection controls that are enabled, its default dry-bulb air temperature setting, default run-time and default motor speed.
note
Division 15 — Air Compressors
812Definitions#
The following definitions apply in this Division.
10 C.F.R. §431.345 means the table to section 431.345 to Subpart T, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.345)
10 C.F.R. Appendix A means Appendix A to Subpart T, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Certain Air Compressors, as amended from time to time. (appendice A 10 C.F.R.)
air compressor means a lubricated rotary compressor that is designed to compress air, has an inlet open to the atmosphere or another source of air, is made up of one or more compression elements (bare compressors), one or more drivers, mechanical equipment to drive the compression elements and any ancillary equipment and has all of the following features:
(a)it is driven by a brushless three-phase electric motor;
(b)it is air- or liquid-cooled;
(c)it is fixed- or variable-speed;
(d)it has a full-load operating pressure that is greater than or equal to 0.52 MPa (75 psig) and less than or equal to 1.38 MPa (200 psig);
(e)it has a full-load actual volume flow rate that is greater than or equal to 0.99 m3/min (35 cfm) or has a motor whose nominal power is greater than or equal to 7.46 kW (10 HP); and
(f)it has a full-load actual volume flow rate that is less than or equal to 35.4 m3/min (1250 cfm) or is sold or supplied with a compressor motor whose nominal power is less than or equal to 149.14 kW (200 HP).
It does not include a liquid ring compressor, a reciprocating compressor or a rotary-type positive displacement compressor for use in the petroleum, petrochemical or natural gas industries. (compresseur d’air)
compressor means a machine or apparatus that converts different types of energy into the potential energy of gas pressure for displacement and compression of gaseous media to any pressure value above atmospheric pressure and has a pressure ratio at full-load operating pressure greater than 1.3. (compresseur)
note
813Energy-using product#
(1)An air compressor is prescribed as an energy-using product.
(2)However, for the purposes of sections 4, 5 and 814, an air compressor is not considered to be an energy-using product unless it is manufactured on or after July 1, 2026.
note
814Energy efficiency standard#
(1)The energy efficiency standard that applies to an air compressor is the minimum package isentropic efficiency set out for the applicable equipment class in 10 C.F.R. §431.345.
(2)An air compressor complies with the energy efficiency standard if it meets that standard when tested in accordance with the applicable testing procedures established by 10 C.F.R. Appendix A.
note
815Information#
For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix A and provided to the Minister in respect of an air compressor:
(a)its equipment class;
(b)the air compressor motor nominal power, expressed in kilowatts (HP);
(c)its dimensionless full-load package isentropic efficiency or part-load package isentropic efficiency, as applicable;
(d)its full-load actual volume flow rate, expressed in m3/min (cfm);
(e)its full-load operating pressure, expressed in MPa (psig);
(f)its maximum full-flow operating pressure, expressed in MPa (psig);
(g)its pressure ratio at full-load operating pressure; and
(h)if any ancillary equipment that is not part of the air compressor package is installed for testing,
(i)a description of the ancillary equipment,
(ii)the manufacturer of the ancillary equipment and, if it is different than the manufacturer, the brand,
(iii)the model number of the ancillary equipment,
(iv)the serial number of the ancillary equipment, if any, and
(v)the input voltage, number of phases and input frequency of the ancillary equipment, if applicable.
note
Schedule 1 / ANNEXE 1 · Explanation for Elements on Household Appliance Energy Efficiency Label / Explication du contenu de l’étiquette indiquant l’efficacité énergétique des appareils domestiques (Subsection 13(1) and section 35 / paragraphe 13(1) et article 35)
Schedule 2 / ANNEXE 2 · Explanation for Elements on Room Air Conditioner Energy Efficiency Label / Explication du contenu de l’étiquette indiquant l’efficacité énergétique des climatiseurs individuels (Paragraph 114(a) / alinéa 114a))
Schedule 3 / ANNEXE 3 · Explanation for Elements on Room Air Conditioner Energy Efficiency Label / Explication du contenu de l’étiquette indiquant l’efficacité énergétique des climatiseurs individuels (Paragraph 114(b) / alinéa 114b))
Schedule 4 / ANNEXE 4 · Explanation for Elements on Portable Air Conditioner Energy Efficiency Label / Explication du contenu de l’étiquette indiquant l’efficacité énergétique des climatiseurs portables (Section 147 / article 147)
Federal laws of Canada reproduced under the Reproduction of Federal Law Order (SI/97-5); not the official version. Source: Justice Laws Website.