Contents
- THE EUROPEAN COMMISSION, Having regard to the Treaty on th…
- 1 Amendments to Regulation (EC) No 152/2009
- 2 Entry into force
- I Methods of sampling
- II General provisions on methods of analysis for feed
- III Methods of analysis to control the composition of feed materials and compound feed
- IV Methods of analysis to control the level of authorised additives in feed
- V Methods of analysis to control undesirable substances in feed
- VI
- VII
THE EUROPEAN COMMISSION,Having regard to the Treaty on the Functioning of the European Union,Having regard to Regulation (EU) 2017/625 of the European Parliament and of the Council of 15 March 2017 on official controls and other official activities performed to ensure the application of food and feed law, rules on animal health and welfare, plant health and plant protection products, amending Regulations (EC) No 999/2001, (EC) No 396/2005, (EC) No 1069/2009, (EC) No 1107/2009, (EU) No 1151/2012, (EU) No 652/2014, (EU) 2016/429 and (EU) 2016/2031 of the European Parliament and of the Council, Council Regulations (EC) No 1/2005 and (EC) No 1099/2009 and Council Directives 98/58/EC, 1999/74/EC, 2007/43/EC, 2008/119/EC and 2008/120/EC, and repealing Regulations (EC) No 854/2004 and (EC) No 882/2004 of the European Parliament and of the Council, Council Directives 89/608/EEC, 89/662/EEC, 90/425/EEC, 91/496/EEC, 96/23/EC, 96/93/EC and 97/78/EC and Council Decision 92/438/EEC (Official Controls Regulation)note, and in particular Article 34(6) thereof,Whereas:
HAS ADOPTED THIS REGULATION:
Article 1Amendments to Regulation (EC) No 152/2009#
Article 2Entry into force#
Annex I · Methods of sampling
1. Purpose and scope
2. Definitions
3. General provisions
4. Apparatus
4.1. The sampling apparatus must be made of materials which cannot contaminate the products to be sampled. Apparatus which is intended to be used multiple times must be easy to clean to avoid any cross-contamination.
4.2. Apparatus recommended for the sampling of solid feed
4.2.1. Manual sampling
4.2.2. Mechanical sampling
4.2.3. Divider
5. Quantitative requirements as regards the number of incremental samples
5.1. Quantitative requirements as regards incremental samples in relation to the control of substances or products uniformly distributed throughout the feed
5.1.1. Loose solid feed
| Size of sampled portion | Minimum number of incremental samples |
|---|---|
| ≤ 2,5 tonnes | 7 |
| > 2,5 tonnes | √ (20 times the number of tonnes making up the sampled portion)note, up to 40 incremental samples |
5.1.2. Loose liquid feed
| Size of sampled portion | Minimum number of incremental samples |
|---|---|
| ≤ 2,5 tonnes or ≤ 2500 litres | 4note |
| > 2,5 tonnes or > 2500 litres | 7note |
5.1.3. Packaged feed
| Size of sampled portion | Minimum number of units from which (at least) one incremental sample has to be takennote |
|---|---|
| 1 to 20 units | 1 unitnote |
| 21 to 150 units | 3 unitsnote |
| 151 to 400 units | 5 unitsnote |
| > 400 units | ¼ of the √ (number of units making up the sampled portion)note, up to 40 units |
5.1.4. Feed blocks and mineral licks
5.1.5. Roughages/forage
| Size of sampled portion | Minimum number of incremental samplesnote |
|---|---|
| ≤ 5 tonnes | 5 |
| > 5 tonnes | √(5 times the number of tonnes making up the sampled portion)note, up to 40 incremental samples |
5.2. Quantitative requirements as regards incremental samples in relation to the control of constituents or substances likely to be distributed non-uniformly in feed
| Size of sampled portion | Minimum number of incremental samples |
|---|---|
| < 80 tonnes | See quantitative requirements under 5.1. The number of incremental samples to be taken has to be multiplied by 2,5. |
| ≥ 80 tonnes | 100 |
5.3. Quantitative requirements as regards the incremental samples in the case of very large lots
6. Quantitative requirements as regards aggregate sample
| Nature of feed | Minimum size of aggregate samplenotenote | |
|---|---|---|
| 6.1. | Loose feed | 4 kg |
| 6.2. | Packaged feed: | 4 kgnote |
| 6.3. | Liquid or semi-liquid feed: | 4 litres |
| 6.4. | Feed blocks or mineral licks: | |
| 6.4.1. | each weighing more than 1 kg | 4 kg |
| 6.4.2. | each weighing not more than 1 kg | weight of four original blocks or licks |
| 6.5. | Roughage/forage | 4 kgnote |
7. Quantitative requirements as regards final samples
Final samples
| Solid feed | 500 gnotenotenotenote |
| Liquid or semi-liquid feed | 500 mlnote |
8. Method of sampling for very large lots or lots stored or transported in a way whereby sampling throughout the lot is not feasible
8.1. General principles
8.2. Large lots transported by ship
8.2.1. Dynamic sampling of large lots transported by ship
8.2.2. Sampling of lots transported by ship by static sampling
8.3. Sampling of large lots stored in warehouses
8.4. Sampling of storage facilities (silos)
8.4.1. Sampling of silos (easily) accessible from above
8.4.2. Sampling of silos not accessible from above (closed silos)
8.4.2.1. Silos not accessible from above (closed silos) with size > 100 tonnes
8.4.2.2. Silos not accessible from above (closed silos) with size < 100 tonnes
8.5. Sampling of loose feed in large closed containers
9. Instructions for taking, preparing and packaging the samples
9.1. General
9.2. Incremental samples
9.2.1. Loose feed
9.2.2. Packaged feed
9.2.3. Homogeneous or homogenisable liquid or semi-liquid feed
9.2.4. Non-homogenisable, liquid or semi-liquid feed
9.2.5. Feed blocks and mineral licks
9.3. Preparation of aggregate samples
9.4. Preparation of final samples
9.4.1. Uniformly distributed substances
9.4.2. Non-uniformly distributed substances
9.5. Packaging of samples
9.6. Sending of samples to the laboratory
10. Sampling record
11. Distance selling sample
Annex II · General provisions on methods of analysis for feed
A. preparation of samples for analysis
1. Purpose
2. Precautions to be taken
3. Procedure
3.1. General procedure
3.1.1. Feed which can be ground as such
3.1.2. Feed which can be ground after drying
3.1.3. Liquid or semi-liquid feed
3.1.4. Other feed
3.2. Specific procedure in case of examination by visual inspection or by microscopy or in cases where the whole aggregate sample is homogenised
4. Storage of samples
B. provisions relating to reagents and apparatus used in methods of analysis
C. application of methods of analysis and expression of the results
1. Extraction procedure
2. Clean-up procedure
3. Number of determinations
4. Reporting of the method of analysis used
5. Reporting of the analytical result
6. Analytical measurement uncertainty and recovery rate in case of analysis of undesirable substances
7. Analytical measurement uncertainty and recovery rate in case of analysis of content of feed additives
III · Methods of analysis to control the composition of feed materials and compound feed
A. determination of moisture
1. Purpose and scope
2. Principle
3. Apparatus
4. Procedure
4.1. Preparation
4.1.1. Feed other than those coming under 4.1.2 and 4.1.3
4.1.2. Cereals and groats
4.1.3. Feed in liquid or paste form, feed predominantly composed of oils and fats
4.2. Drying
4.2.1. Feed other than those coming under points 4.2.2 and 4.2.3
4.2.2. Cereals, flour, groats and meal
4.2.3. Compound feed containing more than 4 % of sucrose or lactose: feed materials such as locust beans, hydrolysed cereal products, malt seeds, dried beet chips, fish and sugar solubles
4.3. Preliminary (partial) drying
5. Calculation of results
5.1. Drying without preliminary drying
5.2. Drying with preliminary dryingFor more details on the calculation, reference is made to EN ISO 6498– Animal Feedingstuffs – Guidelines for sample preparation.
5.3. Repeatability
6. Observation
B. determination of moisture in animal and vegetable fats and oils
1. Purpose and scope
2. Principle
3. Apparatus
4. Procedure
5. Calculation of results
Repeatability
C. determination of the nitrogen content and calculation of crude protein content
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. Digestion
5.2. Distillation
5.2.1. Distillation into sulphuric acid
5.2.2. Distillation into boric acid
5.3. Titration
5.3.1. Sulphuric acid
5.3.2. Boric acid
5.4. Blank test
6. Calculation of results
6.1. Calculation for titration according to point 5.3.1
6.2. Calculation for titration according to point 5.3.2
6.2.1. Titration with hydrochloric acid
6.2.2. Titration with sulphuric acid
7. Verification of the method
7.1. Repeatability
7.2. Reproducibility
7.3. Accuracy
8. Observations
D. determination of urea
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. Analysis of sample
5.2. Calibration curve
6. Calculation of results
7. Evaluation of the method
7.1. Repeatability
7.2. Reproducibility
8. Results of a collaborative study
| MAT 2 | MAT 5 | MAT 3 | MAT 4 | MAT 6 | |
|---|---|---|---|---|---|
| Sheep | Cattle | Sheep | Sheep | Cattle | |
| Target mass fraction (mg kg-1) | 3000 | 5000 | 7001 | 9036 | 11000 |
| Average mass fraction. (mg kg-1) | 4241 | 6993 | 7830 | 9962 | 12071 |
| Reproducibility standard deviation sR (mg kg-1) | 1141 | 1303 | 985 | 994 | 1711 |
| Repeatability standard deviation sr (mg kg-1) | 723 | 601 | 549 | 712 | 737 |
| Reproducibility relative standard deviation RSDR (%) | 27 | 19 | 13 | 10 | 14 |
| Repeatability relative standard deviation RSDr (%) | 17 | 9 | 7 | 7 | 6 |
| Limit of reproducibility, R[R = 2,8 × sR] | 3195 | 3649 | 2759 | 2784 | 4790 |
| Limit of repeatability, r[r = 2,8 × sr] | 2024 | 1684 | 1536 | 1994 | 2064 |
| MAT 2 | MAT 5 | MAT 3 | MAT 4 | MAT 6 | |
|---|---|---|---|---|---|
| Sheep | Cattle | Sheep | Sheep | Cattle | |
| Target mass fraction (mg kg-1) | 3000 | 5000 | 7001 | 9036 | 11000 |
| Average mass fraction. (mg kg-1) | 4101 | 6467 | 7890 | 10062 | 11642 |
| Reproducibility standard deviation sR (mg kg-1) | 706 | 1194 | 675 | 745 | 1378 |
| Repeatability standard deviation sr (mg kg-1) | 570 | 628 | 613 | 196 | 167 |
| Reproducibility relative standard deviation RSDR (%) | 17 | 18 | 9 | 7 | 12 |
| Repeatability relative standard deviation RSDr (%) | 14 | 10 | 8 | 2 | 1 |
| Limit of reproducibility, R[R = 2,8 × sR] | 1977 | 3344 | 1889 | 2087 | 3859 |
| Limit of repeatability, r[r = 2,8 × sr] | 1596 | 1759 | 1715 | 549 | 467 |
9. Observations
E. determination of amino acids (except tryptophan)
1. Purpose and scope
2. Principle
2.1. Free amino acids
2.2. Total amino acids
3. Reagents
4. Apparatus
5. Procedure
5.1. Preparation of the sample
5.2. Determination of free amino acids
5.3. Determination of total amino acids
5.3.1. Oxidation
5.3.2. Hydrolysis
5.3.3. Adjustment of pH
5.3.4. Sample solution for chromatography
5.4. Chromatography
6. Calculation of results
7. Evaluation of the method
| Reference Material | Amino Acid | |||
|---|---|---|---|---|
| Threonine | Cyst(e)ine | Methionine | Lysine | |
| Mixed Pig Feed | 6,94n = 15 | 3,01n = 17 | 3,27n = 17 | 9,55n = 13 |
| Broiler Compound Feed | 9,31n = 16 | 3,92n = 18 | 5,08n = 18 | 13,93n = 16 |
| Protein Concentrate | 22,32n = 16 | 5,06n = 17 | 12,01n = 17 | 47,74n = 15 |
| Premixture | 58,42n = 16 | — | 90,21n = 16 | 98,03n = 16 |
7.1. Repeatability
| Reference Material | Amino Acid | |||
|---|---|---|---|---|
| Threonine | Cyst(e)ine | Methionine | Lysine | |
| Mixed Pig Feed | 1,9n = 15 | 3,3n = 17 | 3,4n = 17 | 2,8n = 13 |
| Broiler Compound Feed | 2,1n = 16 | 2,8n = 18 | 3,1n = 18 | 2,1n = 16 |
| Protein Concentrate | 2,7n = 16 | 2,6n = 17 | 2,2n = 17 | 2,4n = 15 |
| Premixture | 2,2n = 16 | — | 2,4n = 16 | 2,1n = 16 |
7.2. Reproducibility
| Reference Material | Amino Acid | |||
|---|---|---|---|---|
| Threonine | Cyst(e)ine | Methionine | Lysine | |
| Mixed Pig Feed | 4,1n = 15 | 9,9n = 17 | 7,0n = 17 | 3,2n = 13 |
| Broiler Compound feed | 5,2n = 16 | 8,8n = 18 | 10,9n = 18 | 5,4n = 16 |
| Protein Concentrate | 3,8n = 16 | 12,3n = 17 | 13,0n = 17 | 3,0n = 15 |
| Premixture | 4,3n = 16 | — | 6,9n = 16 | 6,7n = 16 |
8. Use of Reference Materials
9. Observations
10. Performance criteria
10.1. Repeatability
10.2. Reproducibility
F. determination of tryptophan
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. Preparation of samples
5.2. Determination of free tryptophan (extract)
5.3. Determination of total tryptophan (hydrolysate)
5.4. HPLC determination
| Liquid chromatographic column (point 4.2): | 125 mm × 4 mm, C18, 3 μm packing or equivalent |
| Column temperature: | Room temperature |
| Mobile phase (point 3.22): | 3,00 g acetic acid (point 3.18) + 900 ml water (point 3.1) + 50,0 ml solution (point 3.21) of 1,1,1-trichloro-2-methyl-2-propanol (point 3.19) in methanol (point 3.8) (1 g/100 ml). Adjust pH to 5,00 using ethanolamine (point 3.20). Make up to 1000 ml with water (point 3.1) |
| Flow rate: | 1 ml/min |
| Total run time: | approx. 34 min |
| Detection wavelength: | excitation: 280 nm, emission: 356 nm. |
| Injection volume | 20 μl. |
6. Calculation of results
7. Repeatability
8. Results of a collaborative study
| Sample 1Pig feed | Sample 2Pig feed supplemented with L-tryptophan | Sample 3Feed concentrate for pigs | |
|---|---|---|---|
| L | 12 | 12 | 12 |
| nMean [g/kg] | 502,42 | 553,40 | 504,22 |
| sr [g/kg] | 0,05 | 0,05 | 0,08 |
| r [g/kg] | 0,14 | 0,14 | 0,22 |
| CVr [%] | 1,9 | 1,6 | 1,9 |
| SR [g/kg] | 0,15 | 0,20 | 0,09 |
| R [g/kg] | 0,42 | 0,56 | 0,25 |
| CVR [%] | 6,3 | 6,0 | 2,2 |
| Sample 4Wheat and soya mixture | Sample 5Wheat and soya mixture (= sample 4) with added tryptophan (0,457 g/kg) | |
|---|---|---|
| Ln | 1255 | 1260 |
| Mean [g/kg] | 0,391 | 0,931 |
| sr [g/kg] | 0,005 | 0,012 |
| r [g/kg] | 0,014 | 0,034 |
| CVr [%] | 1,34 | 1,34 |
| SR [g/kg] | 0,018 | 0,048 |
| R [g/kg] | 0,050 | 0,134 |
| CVR [%] | 4,71 | 5,11 |
| Sample 1Mixed pig feed(CRM 117) | Sample 2Low fat fish meal(CRM 118) | Sample 3Soybean meal(CRM 119) | Sample 4Skimmed milk powder(CRM 120) | |
|---|---|---|---|---|
| L | 7 | 7 | 7 | 7 |
| n | 25 | 30 | 30 | 30 |
| Mean [g/kg] | 2,064 | 8,801 | 6,882 | 5,236 |
| sr [g/kg] | 0,021 | 0,101 | 0,089 | 0,040 |
| r [g/kg] | 0,059 | 0,283 | 0,249 | 0,112 |
| CVr [%] | 1,04 | 1,15 | 1,30 | 0,76 |
| SR [g/kg] | 0,031 | 0,413 | 0,283 | 0,221 |
| R [g/kg] | 0,087 | 1,156 | 0,792 | 0,619 |
| CVR [%] | 1,48 | 4,69 | 4,11 | 4,22 |
9. Observations
9.3. Barium hydroxide
G. determination of crude oils and fats
1. Purpose and scope
1.1. Procedure A – Directly extractable crude oils and fats
1.2. Procedure B – Total crude oils and fats
1.3. Interpretation of results
2. Principle
2.1. Procedure A
2.2. Procedure B
3. Reagents
4. Apparatus
5. Procedure
5.1. Procedure A (see point 8.1)
5.2. Procedure B
5.3. Procedure A and re-extraction by Procedure B
6. Expression of result
7. Repeatability
8. Observations
H. determination of crude fibre
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
6. Calculation of results
7. Repeatability
8. Reproducibility
9. Observations
I. determination of sugar
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. Extraction of sample
5.2. Determination of reducing sugars
5.3. Determination of total sugars after inversion
5.4. Titration by the Luff-Schoorl method
6. Calculation of results
7. Special procedures
8. Observations
J. determination of lactose
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
6. Calculation of results
7. Observation
K. determination of starch
Polarimetric method
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. Preparation of the sample
5.2. Determination of the total optical rotation (P or S) (see observation point 7.1)
5.3. Determination of the optical rotation (P' or S') of substances soluble in 40 % ethanol
6. Calculation of results
6.1. Measurement by polarimeter
6.2. Measurement by saccharimeter
6.3. Repeatability
7. Observations
L. determination of crude ash
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
6. Calculation of results
7. Observations
M. determination of ash which is insoluble in hydrochloric acid
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. Method A
5.2. Method B
6. Calculation of results
7. Observation
N. determination of total phosphorus
Photometric method
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. Preparation of the solution
5.1.1. Usual procedure
5.1.2. Samples containing organic substances and free from calcium and magnesium dihydrogen phosphates
5.2. Development of coloration and measurement of optical density
5.3. Calibration curve
6. Calculation of results
Repeatability
O. determination of chlorine from chlorides
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. Preparation of the solution
5.1.1. Samples free from organic matter
5.1.2. Samples containing organic matter, excluding the products listed under point 5.1.3
5.1.3. Cooked feed, flax cakes and flour, products rich in flax flour and other products rich in mucilage or in colloidal substances (for example, dextrinated starch)
5.2. Titration
6. Calculation of results
7. Observations
Annex IV · Methods of analysis to control the level of authorised additives in feed
A. determination of vitamin a
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. Preparation of the sample
5.2. Saponification
5.3. Extraction
5.3.1. Extraction using a separating funnel (point 4.2.3)
5.3.2. Extraction using an extraction apparatus (point 4.8)
5.4. Preparation of the sample solution for HPLC
5.5. Determination by HPLC
| Liquid chromatographic column (point 4.5.1): | 250 mm × 4 mm, C18, 5 or 10 μm packing, or equivalent |
| Mobile phase (point 3.9): | Mixture of methanol (point 3.3) and water, e.g. 980 + 20 (v + v) |
| Flow rate: | 1–2 ml/min |
| Detector (point 4.5.2): | UV detector (325 nm) or fluorescence detector (excitation: 325 nm/emission: 475 nm). |
5.6. Calibration
5.6.1. Preparation of the working standard solutions
5.6.2. Preparation of the calibration solutions and calibration graph
5.6.3. UV standardisation of the standard solutions
5.6.3.1. Vitamin A acetate stock solution
5.6.3.2. Vitamin A palmitate stock solution
5.6.3.3. Vitamin A working standard solution
6. Calculation of the results
7. Observations
8. Repeatability
9. Results of a collaborative studyConducted by the Feed Working Group of Verband Deutscher Landwirtschaftlicher Untersuchungs- und Forschungsanstalten (VDLUFA).
| Premix | Premix feed | Mineral concentrate | Protein feed | Piglet | |
|---|---|---|---|---|---|
| L | 13 | 12 | 13 | 12 | 13 |
| n | 48 | 45 | 47 | 46 | 49 |
| mean [IU/kg] | 17,02 × 106 | 1,21 × 106 | 537100 | 151800 | 18070 |
| sr [IU/kg] | 0,51 × 106 | 0,039 × 106 | 22080 | 12280 | 682 |
| r [IU/kg] | 1,43 × 106 | 0,109 × 106 | 61824 | 34384 | 1910 |
| CVr [%] | 3,0 | 3,5 | 4,1 | 8,1 | 3,8 |
| sR [IU/kg] | 1,36 × 106 | 0,069 × 106 | 46300 | 23060 | 3614 |
| R [IU/kg] | 3,81 × 106 | 0,193 × 106 | 129640 | 64568 | 10119 |
| CVR [%] | 8,0 | 6,2 | 8,6 | 15 | 20 |
Figure 1 — Extraction apparatus (point 4.8)
B. determination of vitamin e
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. Preparation of the sample
5.2. Saponification
5.3. Extraction
5.3.1. Extraction using a separating funnel (point 4.2.3)
5.3.2. Extraction using an extraction apparatus (point 4.8)
5.4. Preparation of the sample solution for HPLC
5.5. Determination by HPLC
HPLC conditions
| Liquid chromatographic column (point 4.5.1): | 250 mm × 4 mm, C18, 5 or 10 μm packing, or equivalent |
| Mobile phase (point 3.8): | Mixture of methanol (point 3.3) and water, e.g. 980 + 20 (v + v). |
| Flow rate: | 1–2 ml/min |
| Detector (point 4.5.2) | Fluorescence detector (excitation: 295 nm/emission: 330 nm) or UV detector (292 nm). |
5.6. Calibration (DL-α-tocopherol acetate or DL-α-tocopherol)
5.6.1. DL-α-tocopherol acetate standard
5.6.1.1. Preparation of the working standard solution
5.6.1.2. Preparation of the calibration solutions and calibration graph
5.6.1.3. UV standardisation of the DL-α-tocopherol acetate stock solution (point 3.10.1)
5.6.2. DL-α-tocopherol standard
5.6.2.1. Preparation of the working standard solution
5.6.2.2. Preparation of the calibration solutions and calibration graph
5.6.2.3. UV standardisation of the DL-α-tocopherol stock solution (point 3.11.1)
6. Calculation of the results
7. Observations
8. Repeatability·
9. Results of collaborative studyConducted by the Feed Working Group of Verband Deutscher Landwirtschaftlicher Untersuchungs- und Forschungsanstalten (VDLUFA).
| Premix | Premix feed | Mineral concentrate | Protein feed | Piglet | |
|---|---|---|---|---|---|
| L | 12 | 12 | 12 | 12 | 12 |
| n | 48 | 48 | 48 | 48 | 48 |
| mean [mg/kg] | 17380 | 1187 | 926 | 315 | 61,3 |
| sr [mg/kg] | 384 | 45,3 | 25,2 | 13,0 | 2,3 |
| r [mg/kg] | 1075 | 126,8 | 70,6 | 36,4 | 6,4 |
| CVr [%] | 2,2 | 3,8 | 2,7 | 4,1 | 3,8 |
| sR mg/kg] | 830 | 65,0 | 55,5 | 18,9 | 7,8 |
| R [mg/kg] | 2324 | 182,0 | 155,4 | 52,9 | 21,8 |
| CVR [%] | 4,8 | 5,5 | 6,0 | 6,0 | 12,7 |
Figure 2 — Extraction apparatus (point 4.8)
C. determination of the trace elements iron, copper, manganese and zinc
1. Purpose and scope
2. Principle
3. Reagents
Introductory comments
4. Apparatus
5. ProcedureOther methods of digestion may be used provided they have been demonstrated to have similar results (such as microwave pressure digestion).
5.1. Samples containing organic matter
5.1.1. Ashing and preparation of the solution for analysisGreen fodder (fresh or dried) is liable to contain large amounts of vegetable silica, which may retain trace elements and must be removed. For samples of these feed, therefore, the following modified procedure must be followed. Carry out operation 5.1.1.1 as far as the filtration. Wash the filter paper containing the insoluble residue twice with boiling water and place it in a quartz or platinum crucible.Ignite in the muffle furnace (point 4.1) at a temperature below 550 °C until all carbonaceous material has completely disappeared. Allow to cool, add a few drops of water followed by 10 to 15 ml of hydrofluoric acid (point 3.4) and evaporate to dryness at about 150 °C. If any silica remains in the residue, redissolve it in a few millilitres of hydrofluoric acid (point 3.4) and evaporate to dryness. Add five drops of sulphuric acid (point 3.5) and heat until no more white fumes are given off. After the addition of 5 ml of 6 mol/litre hydrochloric acid (point 3.2) and about 30 ml of water, heat, filter the solution into the 250 ml volumetric flask and make up to the mark with water (HCl concentration about 0,5 mol/l). Proceed then with the determination from point 5.1.2.
5.1.2. Spectrophotometric determination
5.1.2.1. Preparation of calibration solutions
| μg Fe/ml | 0 | 0,5 | 1 | 2 | 3 | 4 | 5 |
| ml working standard solution (point 3.7.1) (1 ml = 100 μg Fe) | 0 | 0,5 | 1 | 2 | 3 | 4 | 5 |
| ml HCl (point 3.2) | 7 | 7 | 7 | 7 | 7 | 7 | 7 |
| + 10 ml of lanthanum chloride solution (point 3.11) and make up to 100 ml with water. |
| μg Cu/ml | 0 | 0,1 | 0,2 | 0,4 | 0,6 | 0,8 | 1,0 |
| ml working standard solution (point 3.8.1) (1 ml = 10 μg Cu) | 0 | 1 | 2 | 4 | 6 | 8 | 10 |
| ml HCl (point 3.2) | 8 | 8 | 8 | 8 | 8 | 8 | 8 |
| μg Mn/ml | 0 | 0,1 | 0,2 | 0,4 | 0,6 | 0,8 | 1,0 |
| ml working standard solution (point 3.9.1) (1 ml = 10 μg Mn) | 0 | 1 | 2 | 4 | 6 | 8 | 10 |
| ml HCl (point 3.2) | 7 | 7 | 7 | 7 | 7 | 7 | 7 |
| + 10 ml of lanthanum chloride solution (point 3.11) and make up to 100 ml with water. |
| μg Zn/ml | 0 | 0,05 | 0,1 | 0,2 | 0,4 | 0,6 | 0,8 |
| ml working standard solution (point 3.10.1) (1 ml = 10 μg Zn) | 0 | 0,5 | 1 | 2 | 4 | 6 | 8 |
| ml HCl (point 3.2) | 7 | 7 | 7 | 7 | 7 | 7 | 7 |
| + 10 ml of lanthanum chloride solution (point 3.11) and make up to 100 ml with water. |
5.1.2.2. Preparation of solution for analysis
5.1.2.3. Blank experiment
5.1.2.4. Measurement of the atomic absorption
5.2. Mineral feed
6. Calculation of results
7. Repeatability
8. Observation
D. determination of halofuginone
DL-trans-7-bromo-6-chloro-3-[3-(3-hydroxy-2-piperidyl)acetonyl]-quinazolin-4-(3H)-one hydrobromide
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. General
5.2. Extraction
5.3. Clean up
5.3.1. Preparation of the Amberlite column
5.3.2. Sample clean up
5.4. HPLC determination
5.4.1. Parameters
5.4.2. Calibration graph
5.4.3. Sample solution
6. Calculation of results
7. Validation of the results
7.1. Identity
7.1.1. Co-chromatography
7.1.2. Diode-array detection
7.2. Repeatability
7.3. Recovery
8. Results of a collaborative study
| Sample A (blank)On receipt | Sample B (Meal) | Sample C (Pellets) | |||
|---|---|---|---|---|---|
| On receipt | After two months | On receipt | After two months | ||
| Mean [mg/kg] | ND | 2,80 | 2,42 | 2,89 | 2,45 |
| SR [mg/kg] | — | 0,45 | 0,43 | 0,40 | 0,42 |
| CVR [%] | — | 16 | 18 | 14 | 17 |
| Rec. [%] | 86 | 74 | 88 | 75 |
E. determination of robenidine
1,3-bis [(4-chlorobenzylidene)amino]guanidine – hydrochloride
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. General
5.2. Extraction
5.3. Purification
5.3.1. Preparation of the aluminium-oxide column
5.3.2. Sample purification
5.4. HPLC determination
5.4.1. Parameters
5.4.2. Calibration graph
5.4.3. Sample solution
6. Calculation of results
7. Validation of the results
7.1. Identity
7.1.1. Co-chromatography
7.1.2. Diode-array detection
7.2. Repeatability
7.3. Recovery
8. Results of a collaborative study
| Poultry | Rabbit | |||
|---|---|---|---|---|
| Meal | Pellet | Meal | Pellet | |
| Mean [mg/kg] | 27,00 | 27,99 | 43,6 | 40,1 |
| sr [mg/kg] | 1,46 | 1,26 | 1,44 | 1,66 |
| CVr [%] | 5,4 | 4,5 | 3,3 | 4,1 |
| SR [mg/kg] | 4,36 | 3,36 | 4,61 | 3,91 |
| CVR [%] | 16,1 | 12,0 | 10,6 | 9,7 |
| Recovery [%] | 90,0 | 93,3 | 87,2 | 80,2 |
F. determination of diclazuril
(+)-4-chlorphenyl [2,6-dichloro-4-(2,3,4,5-tetrahydro-3,5-dioxo-1,2,4-triazin-2-yl)phenyl] acetonitrile.
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. General
5.1.1. Blank feed
5.1.2. Recovery test
5.2. Extraction
5.2.1. Compound feed
5.2.2. Premixtures
5.3. HPLC determination
5.3.1. Parameters
5.3.2. Chromatographic analysis of calibration solutions
5.3.3. Chromatographic analysis of sample solutions
6. Calculation of the results
6.1. Compound feed
6.2. Premixtures
7. Validation of the results
7.1. Identity
7.1.1. Co-chromatography
7.1.2. Diode-array detection
7.2. Repeatability
7.3. Recovery
8. Results of a collaborative study
| Sample 1A 100 | Sample 2O 100 | Sample 3 L1 | Sample 4 Z1 | Sample 5 K1 | Sample 6MAT 1 | Sample 7MAT 2 | Sample 8MAT 3 | |
|---|---|---|---|---|---|---|---|---|
| L | 11 | 11 | 11 | 11 | 6 | 10 | 9 | 10 |
| n | 19 | 18 | 19 | 19 | 12 | 20 | 18 | 10 |
| Mean (mg/kg) | 100,8 | 103,5 | 0,89 | 1,15 | 0,89 | 1,0 | 1,5 | < LOQ |
| Sr (mg/kg) | 5,88 | 7,64 | 0,15 | 0,02 | 0,03 | 0,11 | 0,07 | — |
| CVr (%) | 5,83 | 7,38 | 17,32 | 1,92 | 3,34 | 11,2 | 4,5 | — |
| SR (mg/kg) | 7,59 | 7,64 | 0,17 | 0,11 | 0,12 | 0,18 | 0,21 | — |
| CVR (%) | 7,53 | 7,38 | 18,61 | 9,67 | 13,65 | 18,1 | 14,3 | — |
| Nominal content (mg/kg) | 100 | 100 | 1,0 | 1,0 | 1,0 | 0,9 | 1,5 | — |
| Referencenote | First study from 1994 | First study from 1994 | First study from 1994 | First study from 1994 | First study from 1994 | Second study from 2015 | Second study from 2015 | Second study from 2015 |
9. General comments
G. determination of lasalocid sodium
Sodium salt of a polyether monocarboxylic acid produced by Streptomyces lasaliensis.
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. General
5.1.1. Blank feed
5.1.2. Recovery test
5.2. Extraction
5.2.1. Feed
5.2.2. Premixtures
5.3. HPLC determination
5.3.1. Parameters
| Liquid chromatographic column (point 4.3.1): | 125 mm × 4 mm, reversed-phase C18, 5 μm packing or equivalent |
| Mobile phase (point 3.9): | Mixture of phosphate buffer solution (point 3.7) and methanol (point 3.5), 5 + 95 (V + V) |
| Flow rate: | 1,2 ml/min |
| Detection wavelengths: | Excitation: 310 nm |
| Emission: 419 nm | |
| Injection volume: | 20 μl |
5.3.2. Calibration graph
5.3.3. Sample solution
6. Calculation of results
6.1. Feed
6.2. Premixtures
7. Validation of the results
7.1. Identity
7.1.1. Co-chromatography
7.2. Repeatability
7.3. Recovery
8. Results of a collaborative study
| Sample 1Chicken premix | Sample 2Turkey premix | Sample 3Turkey pellets | Sample 4Chicken crumbs | Sample 5Turkey Feed | Sample 6Poultry Feed A | Sample 7Poultry Feed B | |
|---|---|---|---|---|---|---|---|
| L | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
| n | 23 | 23 | 23 | 23 | 23 | 23 | 23 |
| Mean [mg/kg] | 5050 | 16200 | 76,5 | 78,4 | 92,9 | 48,3 | 32,6 |
| sr [mg/kg] | 107 | 408 | 1,71 | 2,23 | 2,27 | 1,93 | 1,75 |
| CVr [%] | 2,12 | 2,52 | 2,24 | 2,84 | 2,44 | 4,00 | 5,37 |
| sR [mg/kg] | 286 | 883 | 3,85 | 7,32 | 5,29 | 3,47 | 3,49 |
| CVR [%] | 5,66 | 5,45 | 5,03 | 9,34 | 5,69 | 7,18 | 10,70 |
| Nominal content [mg/kg] | 5000note | 16000note | 80note | 105note | 120note | 50note | 35note |
H. determination of amprolium hydrochloride
1-[(4-amino-2-propyl-5-pyrimidinyl)methyl]-2-methylpyridinium chloride monohydrochloride
1. Purpose and scope
2. Principle
3. Reagents
4. Apparatus
5. Procedure
5.1. General
5.1.1. Blank feed
5.1.2. Recovery test
5.2. Extraction
5.2.1. Premixtures (content < 1 % amprolium) and feed
5.2.2. Premixtures (content ≥ 1 % amprolium)
5.3. HPLC determination
5.3.1. Parameters
| Liquid chromatographic column (point 4.1.1): | 125 mm × 4 mm, cation exchange Nucleosil 10 SA, 5 or 10 μm packing, or equivalent |
| Mobile phase (point 3.6): | Mixture of acetonitrile (point 3.2), sodium dihydrogen phosphate solution (point 3.4) and sodium perchlorate solution (point 3.5), 450 + 450 + 100 (v + v + v). |
| Flow rate: | 0,7–1 ml/min |
| Detection wavelength: | 264 nm |
| Injection volume: | 100 μl |
5.3.2. Calibration graph
5.3.3. Sample solution
6. Calculation of the results
7. Validation of the results
7.1. Identity
7.1.1. Co-chromatography
7.1.2. Diode array detection
7.2. Repeatability
7.3. Recovery
8. Results of a collaborative study
| sample 1 (blank feed) | sample 2 | sample 3 | sample 4 | sample 5 | |
|---|---|---|---|---|---|
| L | 14 | 14 | 14 | 14 | 15 |
| n | 56 | 56 | 56 | 56 | 60 |
| mean [mg/kg] | — | 45,5 | 188 | 5129 | 25140 |
| sr [mg/kg] | — | 2,26 | 3,57 | 178 | 550 |
| CVr [%] | — | 4,95 | 1,90 | 3,46 | 2,20 |
| sR [mg/kg] | — | 2,95 | 11,8 | 266 | 760 |
| CVR [%] | — | 6,47 | 6,27 | 5,19 | 3,00 |
| nominal content [mg/kg] | — | 50 | 200 | 5000 | 25000 |
9. Observations
I. determination of narasin
J. determination of nicarbazin
K. determination of decoquinate
L. determination of monensin
M. determination of salinomycin
N. determination of semduramycin
O. en standards
Annex V · Methods of analysis to control undesirable substances in feed
A. DETERMINATION OF THE LEVELS OF DIOXINS (PCDD/PCDF) AND PCBs
Chapter I — methods of sampling and interpretation of analytical results
1. Scope and definitions
2. Compliance of the lot or sublot with the maximum level
2.1. As regards non-dioxin-like PCBs
2.2. As regards PCDD/Fs and dioxin-like PCBs
3. Results exceeding action thresholds as laid down in Annex II to Directive 2002/32/EC
Chapter II — sample preparation and requirements for methods of analysis used in offical control of the levels of dioxins (pcdd/fs) and dioxin-like pcbs in feed
1. Field of application
(a) Screening methods
(b) Confirmatory methods
2. Background
3. Quality assurance requirements
4. Requirements for laboratories
5. Basic requirements to be met by analytical procedure for dioxins (PCDD/Fs) and dioxin-like PCBs
5.1. Low working range and limits of quantification
5.2. High selectivity (specificity)
5.3. High accuracy (trueness and precision, bioassay apparent recovery)
5.4. Validation in the range of maximum level and general quality control measures
5.5. Limit of quantification
5.6. Analytical criteria
| Screening with bioanalytical or physico-chemical methods | Confirmatory methods | |
|---|---|---|
| False-compliant ratenote | < 5 % | |
| Trueness | –20 % to +20 % | |
| Repeatability (RSDr) | < 20 % | |
| Intermediate precision (RSDR) | < 25 % | < 15 % |
5.7. Specific requirements for screening methods
6. Specific requirements for GC-MS methods to be complied with for screening or confirmatory purposes
6.1. Acceptable differences between upper-bound and lower-bound WHO-TEQ results
6.2. Control of recoveries
6.3. Removal of interfering substances
6.4. Calibration with standard curve
6.5. Specific criteria for confirmatory methods
7. Specific requirements for bioanalytical methods
7.1. Evaluation of the test response
7.1.1. General requirements
7.1.2. Calibration
7.1.2.1. Calibration with standard curve
7.1.2.2. Calibration with reference samples
7.1.3. Separate determination of PCDD/Fs and dioxin-like PCBs
7.1.4. Bioassay apparent recoveries
7.1.5. Control of recoveries for clean-up
7.1.6. Reporting limit
7.2. Use of reference samples
7.3. Determination of cut-off values
Figure 1
7.4. Performance characteristics
8. Reporting of the results
8.1. Confirmatory methods
8.2. Bioanalytical screening methods
8.3. Physico-chemical screening methods
Chapter III — sample preparation and requirements for methods of analysis used in offical control of the levels of non-dioxin-like pcbs in feed
1. Field of application
2. Applicable detection methods
3. Identification and confirmation of analytes of interest
4. Demonstration of performance of method
5. Limit of quantification
6. Quality control
7. Control of recoveries
8. Requirements for laboratories
9. Performance characteristics: criteria for the sum of non-dioxin-like PCBs at the maximum level
| Isotope dilution mass spectrometrynote | Other techniques | |
|---|---|---|
| Trueness | –20 to +20 % | –30 to +30 % |
| Intermediate precision (RSD %) | ≤ 15 % | ≤ 20 % |
| Difference between upper and lower-bound calculation | ≤ 20 % | ≤ 20 % |
10. Reporting of the results
B. en standards
Annex VI
VII
Method of calculating the energy value of poultry feed
1. Method of calculation and expression of energy value
2. Tolerances applicable to declared values
3. Expression of result
4. Sampling and analysis methods
Method of calculating the energy value in feed materials and compound feed for cats and dogs
Source: EUR-Lex, © European Union, 1998-2026. Reuse authorised under Decision 2011/833/EU.