Contents
- THE EUROPEAN COMMISSION, Having regard to the Treaty on th…
- 1 A Union authorisation with authorisation number EU-0027044…
- 2 This Regulation shall enter into force on the twentieth da…
- Summary of product characteristics for a biocidal productGHC ChlorProduct type 2 – Disinfectants and algaecides not intended for direct application to humans or animals (Disinfectants)Product type 5 – Drinking water (Disinfectants)Authorisation number: EU-0027044-0000R4BP asset number: EU-0027044-0000
- 1. Administrative information
- 2. Product composition and formulation
- 3. Hazard and precautionary statements
- 4. Authorised use(s)
- 5. GENERAL DIRECTIONS FOR USEInstructions for use, risk mitigation measures and other directions for use under this section are valid for any authorised uses.
- 6. Other information
THE EUROPEAN COMMISSION,Having regard to the Treaty on the Functioning of the European Union,Having regard to Regulation (EU) No 528/2012 of the European Parliament and of the Council of 22 May 2012 concerning the making available on the market and use of biocidal productsnote, and in particular Article 44(5), first subparagraph, thereof,Whereas:
(1)On 10 December 2018, GHC Gerling, Holz & Co. Handels GmbH submitted to the European Chemicals Agency (‘the Agency’) an application in accordance with Article 43(1) of Regulation (EU) No 528/2012 and Article 4 of Commission Implementing Regulation (EU) No 414/2013note for authorisation of the same single biocidal product, as referred to in Article 1 of Implementing Regulation (EU) No 414/2013, named ‘GHC Chlor’ of product-types 2 (disinfectants and algaecides not intended for direct application to humans or animals) and 5 (drinking water) as described in Annex V to Regulation (EU) No 528/2012. The application was recorded under case number BC-EN045705-33 in the Register for Biocidal Products (‘the Register’). The application also indicated the application number of the related reference single biocidal product ‘Arche Chlorine’, recorded in the Register under case number BC-UQ045679-98.
(2)‘GHC Chlor’ contains active chlorine released from chlorine as the active substance, included in the Union list of approved active substances referred to in Article 9(2) of Regulation (EU) No 528/2012, for product-types 2 and 5.
(3)On 3 August 2021, the Agency submitted to the Commission its opinionnote and the draft summary of the biocidal product characteristics (‘SPC’) of ‘GHC Chlor’ in accordance with Article 6(1) and (2) of Implementing Regulation (EU) No 414/2013.
(4)In its opinion, the Agency concludes that the differences, proposed by GHC Gerling, Holz & Co. Handels GmbH, between the same biocidal product and the related reference biocidal product are limited to information which can be the subject of an administrative change in accordance with Article 11 of Commission Implementing Regulation (EU) No 354/2013note, and that based on the assessment of Arche Chlorine and subject to compliance with the draft SPC, the same single biocidal product meets the conditions laid down in Article 19(1) of Regulation (EU) No 528/2012.
(5)On 15 June 2023, the Agency transmitted to the Commission the draft SPC in all the official languages of the Union in accordance with Article 44(4) of Regulation (EU) No 528/2012.
(6)The Commission also considers that the request made by Germany to adjust the conditions of the Union authorisation of the single biocidal product ‘Arche Chlorine’ for its territory in accordance with Article 44(5), second subparagraph, of Regulation (EU) No 528/2012 also applies for the uses 2, 3 and 4 of ‘GHC Chlor’. This adjustment is justified in recitals 7 to 9 of Commission Implementing Regulation (EU) 2023/754note granting a Union authorisation for the single biocidal product ‘Arche Chlorine’ in accordance with Regulation (EU) No 528/2012.
(7)The Commission concurs with the opinion of the Agency and considers it therefore appropriate to grant a Union authorisation for the same single biocidal product ‘GHC Chlor’ with the adjustments of the SPC as requested by Germany for its territory for the uses 2, 3 and 4 in accordance with Article 44(5), second subparagraph, of Regulation (EU) No 528/2012.
(8)The expiry date of this authorisation is aligned to the expiry date of the reference single biocidal product ‘Arche Chlorine’.
(9)The measures provided for in this Regulation are in accordance with the opinion of the Standing Committee on Biocidal Products,
HAS ADOPTED THIS REGULATION:
Article 1#
A Union authorisation with authorisation number EU-0027044-0000 is granted to GHC Gerling, Holz & Co. Handels GmbH for the making available on the market and use of the same single biocidal product ‘GHC Chlor’ in accordance with the summary of the biocidal product characteristics set out in the Annex.For the territory of the Federal Republic of Germany, adjustments to the terms and conditions apply for the uses 2, 3 and 4 of ‘GHC Chlor’ as laid down in the summary of product characteristics in the Annex.The Union authorisation is valid from 20 December 2023 until 30 April 2033.
Article 2#
This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.
Summary of product characteristics for a biocidal productGHC ChlorProduct type 2 – Disinfectants and algaecides not intended for direct application to humans or animals (Disinfectants)Product type 5 – Drinking water (Disinfectants)Authorisation number: EU-0027044-0000R4BP asset number: EU-0027044-0000
1. Administrative information
1.1. Trade name(s) of the product
| Trade name(s) | ChlorGHC ChlorChlorineGHC ChlorineChloreGHC ChloreхлорGHC хлорKlorGHC KlorχλώριοGHC χλώριοChloorGHC ChloorChlor kapalnýGHC Chlor kapalnýKloorGHC KloorKlooriGHC KlooriKlórGHC KlórCloroGHC CloroHlorsGHC HlorsChlorasGHC ChlorasKlorurGHC KlorurClorGHC ClorChlórGHC ChlórBOC ChlorineChlor flüssig > 99,8 %CHLORGAS FLUESSIG (99,8 %)trave Chlor |
1.2. Authorisation holder
| Name and address of the authorisation holder | Name | GHC Gerling, Holz & Co. Handels GmbH |
| Address | Ruhrstraße 113, 22761 Hamburg, Germany | |
| Authorisation number | EU-0027044-0000 | |
| R4BP asset number | EU-0027044-0000 | |
| Date of the authorisation | 20 December 2023 | |
| Expiry date of the authorisation | 30 April 2033 |
1.3. Manufacturer(s) of the product
| Name of manufacturer | GHC Gerling, Holz & Co. Handels GmbH |
| Address of manufacturer | Ruhrstraße 113, 22761 Hamburg, Germany |
| Location of manufacturing sites | Ruhrstraße 113, 22761 Hamburg, GermanyKinzigheimer Weg 109, 63450 Hanau, GermanySiemensstraße 20, 41542 Dormagen, GermanyBreitenau 15, 85232 Bergkirchen, GermanyLöbejüner Straße 21, 06193 Wettin-Löbejün OT Merbit, GermanyWaldstraße 13, 64584 Biebesheim, GermanyAm Haupttor/Bau 3651, 06237 Leuna, Germany |
| Name of manufacturer | GHC Invest s.r.o. |
| Address of manufacturer | Korunovační 103/6, 170 00 Praha 7, Czech Republic |
| Location of manufacturing sites | Korunovační 103/6, 170 00 Praha 7, Czech RepublicTovární 157, 277 11 Neratovice, Czech RepublicNa Letišti 415/104, 750 02 Bochoř okres Přerov, Czech RepublicMinická 635, 278 01 Kralupy nad Vltavou, Czech Republic |
1.4. Manufacturer(s) of the active substance(s)
| Active substance | Active chlorine released from chlorine |
| Name of manufacturer | Nobian Industrial Chemicals BV |
| Address of manufacturer | Velperweg 76, 6824 BM Arnhem, Netherlands |
| Location of manufacturing sites | Hauptstraße 47, 49479 Ibbenbüren, GermanyElektrolysestr. 1, 06749 Bitterfeld, GermanyIndustriepark Höchst Geb. B598, 65926 Frankfurt am Main Germany |
| Active substance | Active chlorine released from chlorine |
| Name of manufacturer | Arkema France |
| Address of manufacturer | 85 route Nationale, 38560 Jarrie, France |
| Location of manufacturing sites | 85 route Nationale, 38560 Jarrie, France |
| Active substance | Active chlorine released from chlorine |
| Name of manufacturer | CABB GmbH |
| Address of manufacturer | Ludwig Hermann Str. 100, 86368 Gersthofen, Germany |
| Location of manufacturing sites | Ludwig Hermann Str. 100, 86368 Gersthofen, Germany |
| Active substance | Active chlorine released from chlorine |
| Name of manufacturer | Donau Chemie AG |
| Address of manufacturer | Klagenfurter Str. 17, 9371 Brückl, Austria |
| Location of manufacturing sites | Klagenfurter Str. 17, 9371 Brückl, Austria |
| Active substance | Active chlorine released from chlorine |
| Name of manufacturer | Inovyn Chlorvinyls Limited |
| Address of manufacturer | South Parade WA7, 4JE Runcorn, United Kingdom |
| Location of manufacturing sites | South Parade WA7, 4JE Runcorn, United Kingdom |
| Active substance | Active chlorine released from chlorine |
| Name of manufacturer | Métaux Spéciaux (MSSA S.A.S.) |
| Address of manufacturer | 111 rue de la Volta, 73600 Saint-Marcel, France |
| Location of manufacturing sites | 111 rue de la Volta, 73600 Saint-Marcel, France |
| Active substance | Active chlorine released from chlorine |
| Name of manufacturer | PCC Rokita SA |
| Address of manufacturer | ul. Sienkiewicza 4, 56-120 Brzeg Dolny, Poland |
| Location of manufacturing sites | ul. Sienkiewicza 4, 56-120 Brzeg Dolny, Poland |
| Active substance | Active chlorine released from chlorine |
| Name of manufacturer | PPC SAS |
| Address of manufacturer | 95 rue du Général de Gaulle, 68800 Thann Cedex, France |
| Location of manufacturing sites | 95 rue du Général de Gaulle, 68800 Thann Cedex, France |
| Active substance | Active chlorine released from chlorine |
| Name of manufacturer | Vencorex France SAS |
| Address of manufacturer | Rue Lavoisier, 38800 Le Pont de Claix, France |
| Location of manufacturing sites | Rue Lavoisier, 38800 Le Pont de Claix, France |
2. Product composition and formulation
2.1. Qualitative and quantitative information on the composition of the product
| Common name | IUPAC name | Function | CAS number | EC number | Content (%) |
|---|---|---|---|---|---|
| Active chlorine released from chlorine | Active Substance | 100,0 | |||
| chlorine | chlorine | Non-active substance | 7782-50-5 | 231-959-5 | 100,0 |
2.2. Type of formulation
GA – Gas
3. Hazard and precautionary statements
| Hazard statements | May cause or intensify fire; oxidiserCauses skin irritation.Causes serious eye irritation.Toxic if inhaled.May cause respiratory irritation.Very toxic to aquatic life.Contains gas under pressure; may explode if heated |
| Precautionary statements | Keep away from clothing and other combustible materials.Do not breathe gas.Avoid release to the environment.Wear protective gloves.Wear protective clothing.Wear eye protection.Wear face protection.IF INHALED: Remove person to fresh air and keep comfortable for breathing.IF IN EYES: Rinse cautiously with water for several minutes.Remove contact lenses, if present and easy to do. Continue rinsing.Collect spillage.Store in a well-ventilated place.Keep container tightly closed.Store locked up.Protect from sunlight.Store in a well-ventilated place.In case of fire: Stop leak if safe to do so.Dispose of contents to local regulation.Keep valves and fittings free from oil and grease.Call a doctor if you feel unwell.Avoid breathing gas.Wash hands thoroughly after handling.Use only outdoors or in a well-ventilated area.IF ON SKIN: Wash with plenty of water.Call a Poison center/doctor.Specific treatment (see reference to supplemental first aid instruction on this label).If skin irritation occurs:Get medical attention.If eye irritation persists:Get medical attention.Take off contaminated clothing.And wash it before reuse. |
4. Authorised use(s)
4.1. Use description
| Product type | PT02 – Disinfectants and algaecides not intended for direct application to humans or animals (Disinfectants) |
| Where relevant, an exact description of the authorised use | / |
| Target organism(s) (including development stage) | Scientific name: bacteriaCommon name: BacteriaDevelopment stage:Scientific name: virusesCommon name: VirusesDevelopment stage: |
| Field(s) of use | IndoorOutdoorDisinfection of waste water after the waste water plant, by shock dosing (in case of contamination). |
| Application method(s) | Method: Closed systemDetailed description:Automated dosing system. |
| Application rate(s) and frequency | Application Rate: Shock dosing: 477 mg/l active chlorine (AC) under dirty conditions.Dilution (%): –Number and timing of application:Contact time: 30 minutes |
| Category(ies) of users | IndustrialProfessional |
| Pack sizes and packaging material | Cylinder: 4,8-140 l (6-175 kg Cl2)Drum: 400-1000 l (500-1250 kg Cl2)Railway tanks: 43000-44000 l (53750-55000 kg Cl2)Carbon/stainless steel |
4.1.1. Use-specific instructions for use
Connect the chlorine cylinder or drum to the automated dosing system, closed dosing system. Set up the parameters of the system to obtain an active chlorine concentration in the water according to the application rate indicated above.
4.1.2. Use-specific risk mitigation measures
Reduce residual concentrations of active chlorine by active carbon filtration or addition of reducing agents (e.g. ascorbic acid or sodium ascorbate) before discharging the waste water to surface water. Alternatively, water can be retained in a buffer before discharge.
Regular water quality assessments should be performed to assure the effluent meets all required quality standards.
4.1.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See Section 5 – General directions for use.
4.1.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See Section 5 – General directions for use.
4.1.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See Section 5 – General directions for use.
4.2. Use description
| Product type | PT05 – Drinking water (Disinfectants) |
| Where relevant, an exact description of the authorised use | / |
| Target organism(s) (including development stage) | Scientific name: bacteriaCommon name: BacteriaDevelopment stage:Scientific name: virusesCommon name: VirusesDevelopment stage: |
| Field(s) of use | IndoorOutdoorDisinfection at the drinking water suppliers and their water distribution systems, by continuous dosing. |
| Application method(s) | Method: Closed systemDetailed description:Automated dosing systemAdjustment applicable in the territory of the Federal Republic of Germany in accordance with Article 44(5) of Regulation (EU) No 528/2012:In accordance with the list of treatment substances and disinfection processes of paragraph 11 of the German Drinking Water Ordinance (1), the technical rules for dosing set out in the Deutscher Verein des Gas Wasserfaches e.V (2) – working sheets W 229, W 296, W 623 and the minimum contact time of W 229 apply (3). (See section 6 for further references) |
| Application rate(s) and frequency | Application Rate: 0,5 mg/l active chlorine (AC) as residual concentration in the systemDilution (%): –Number and timing of application:Frequency: continuous dosingAdjustment applicable in the territory of the Federal Republic of Germany in accordance with Article 44(5) of Regulation (EU) No 528/2012:In accordance with the list of treatment substances and disinfection processes of paragraph 11 of the German Drinking Water Ordinance (See section 6 for further reference) (4)Application rate:Maximum addition 1,2 mg/l free Cl2Concentration range after completion of treatment: maximum 0,3 mg/l free Cl2, minimum 0,1 mg/l free Cl2 (including the amounts before treatment and from other treatments) as residual concentration in the systemIn exceptional cases an addition of up to 6 mg/l free Cl2 and concentration of up to 0,6 mg/l free Cl2 after treatment is acceptable as residual concentration in the system, if disinfection cannot be ensured by other means or if disinfection is temporarily impaired by ammonium. |
| Category(ies) of users | Professional |
| Pack sizes and packaging material | Cylinder: 4,8-140 l (6-175 kg Cl2)Drum: 400-1000 l (500-1250 kg Cl2)Railway tanks: 43000-44000 l (53750-55000 kg Cl2)Carbon/stainless steel |
4.2.1. Use-specific instructions for use
Connect the chlorine cylinder or drum to the automated, closed dosing system. Set up the parameters of the system to obtain an active chlorine concentration in the water according to the application rate indicated above.
Please note that some Member States after primary disinfection, request to maintain a residual level of available chlorine in drinking water in the pipes as a precautionary measure. This additional amount, claimed by the applicant as ‘Secondary disinfection: 0,1 to 0,5 mg/l available chlorine (residual)’ has been considered as ‘covered by the primary disinfection’.
4.2.2. Use-specific risk mitigation measures
Ensure that the concentration of chlorine in the drinking water does not exceed national chlorine limits before consumption.
Ensure that the concentration of chlorate present in the drinking water does not exceed the parametric values set in Directive (EU) 2020/2184 of the European Parliament and of the Council of 16 December 2020 on the quality of water intended for human consumption (OJ L 435, 23.12.2020, p. 1).
4.2.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See Section 5 – General directions for use
4.2.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See Section 5 – General directions for use
4.2.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See Section 5 – General directions for use
4.3. Use description
| Product type | PT05 – Drinking water (Disinfectants) |
| Where relevant, an exact description of the authorised use | / |
| Target organism(s) (including development stage) | Scientific name: bacteriaCommon name: BacteriaDevelopment stage:Scientific name: virusesCommon name: VirusesDevelopment stage: |
| Field(s) of use | IndoorOutdoorDisinfection of water (with water coming from tap water network), in reservoirs/tanks, by continuous dosing. |
| Application method(s) | Method: Closed systemDetailed description:Automated dosing system. The disinfection is carried out in the inlet of the reservoir, in order to assure proper distribution of the disinfectant in the water.Adjustment applicable in the territory of the Federal Republic of Germany in accordance with Article 44(5) of Regulation (EU) No 528/2012:In accordance with the list of treatment substances and disinfection processes of paragraph 11 of the German Drinking Water Ordinance (1), the technical rules for dosing set out in the Deutscher DeutscherVerein des Gas Wasserfaches e.V (2) – working sheets W 229, W 296, W 623 and the minimum contact time of W 229 apply (3). (See section 6 for further references) |
| Application rate(s) and frequency | Application Rate: 0,5 mg/l Active Chlorine (AC) as residual concentration in the system.Dilution (%): –Number and timing of application:Frequency: continuous dosingAdjustment applicable in the territory of the Federal Republic of Germany in accordance with Article 44(5) of Regulation (EU) No 528/2012:In accordance with the list of treatment substances and disinfection processes of paragraph 11 of the German Drinking Water Ordinance (1). (See section 6 for further reference) (4).Application rate: maximum addition 1,2 mg/l free Cl2;Concentration range after completion of treatment: maximum 0,3 mg/l free Cl2, min 0,1 mg/L free Cl2 (including the amounts before treatment and from other treatments)In exceptional cases an addition of up to 6 mg/l free Cl2 and concentration up to 0,6 mg/l free Cl2 after treatment is acceptable, if disinfection cannot be ensured by other means or if disinfection is temporarily impaired by the presence of ammonium. |
| Category(ies) of users | Professional |
| Pack sizes and packaging material | Cylinder: 4,8-140 l (6-175 kg Cl2)Drum: 400-1000 l (500-1250 kg Cl2)Railway tanks: 43000-44000 l (53750-55000 kg Cl2)Carbon/stainless steel |
4.3.1. Use-specific instructions for use
Connect the chlorine cylinder or drum to the automated, closed dosing system. Set up the parameters of the system to obtain a continuous active chlorine concentration in the water according to the application rate indicated above.
4.3.2. Use-specific risk mitigation measures
Ensure that the concentration of chlorine in the drinking water does not exceed national chlorine limit before consumption.
Ensure that the concentration of chlorate present in the drinking water does not exceed the parametric values set in Directive (EU) 2020/2184 of the European Parliament and of the Council of 16 December 2020 on the quality of water intended for human consumption (OJ L 435, 23.12.2020, p. 1).
4.3.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See Section 5 – General directions for use
4.3.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See Section 5 – General directions for use
4.3.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See Section 5 – General directions for use
4.4. Use description
| Product type | PT05 – Drinking water (Disinfectants) |
| Where relevant, an exact description of the authorised use | / |
| Target organism(s) (including development stage) | Scientific name: bacteriaCommon name: BacteriaDevelopment stage:Scientific name: virusesCommon name: VirusesDevelopment stage:Scientific name: legionella pneumophilaCommon name: BacteriaDevelopment stage: |
| Field(s) of use | IndoorOutdoorIn Public institutions, healthcare facilitiesDisinfection of drinking water in collective drinking water systems by continuous dosing |
| Application method(s) | Method: Closed systemDetailed description:Automated dosing systemAdjustment applicable in the territory of the Federal Republic of Germany in accordance with Article 44(5) of Regulation (EU) No 528/2012:In accordance with the list of treatment substances and disinfection processes of paragraph 11 of the German Drinking Water Ordinance, the requirements set out in the Deutscher Verein des Gas Wasserfaches e.V (2) – working sheets W 229, W 296, W 623 and the minimum contact time of W 229 apply (3). (See section 6 for further references). |
| Application rate(s) and frequency | Application Rate: 1 mg/l active chlorine (AC) as residual concentration in the systemDilution (%): –Number and timing of application:Frequency: continuous dosingAdjustment applicable in the territory of the Federal Republic of Germany in accordance with Article 44(5) of Regulation (EU) No 528/2012:In accordance with the list of treatment substances and disinfection processes of paragraph 11 of the German Drinking Water Ordinance (1). (See section 6 for further reference) (4)Application rate: maximum addition 1,2 mg/l free Cl2;Concentration range after completion of treatment: maximum 0,3 mg/l free Cl2, min 0,1 mg/L free Cl2 (including the amounts before treatment and from other treatments)In exceptional cases an addition of up to 6 mg/l free Cl2 and concentration up to 0,6 mg/l free Cl2 after treatment is acceptable, if disinfection cannot be ensured by other means or if disinfection is temporarily impaired by the presence of ammonium. |
| Category(ies) of users | Professional |
| Pack sizes and packaging material | Cylinder: 4,8-140 l (6-175 kg Cl2)Drum: 400-1000 l (500-1250 kg Cl2)Railway tanks: 43000-44000 l (53750-55000 kg Cl2)Carbon/stainless steel |
4.4.1. Use-specific instructions for use
Connect the chlorine cylinder or drum to the automated, closed dosing system. Set up the parameters of the system to obtain a continuous active chlorine concentration in the water according to the application rate indicated above.
4.4.2. Use-specific risk mitigation measures
Ensure that the concentration of chlorine in the drinking water does not exceed national chlorine limit before consumption.
Ensure that the concentration of chlorate present in the drinking water does not exceed the parametric values set in Directive (EU) 2020/2184 of 16 December 2020 on the quality of water intended for human consumption (OJ L 435, 23.12.2020, p. 1).
4.4.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See Section 5 – General directions for use
4.4.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See Section 5 – General directions for use
4.4.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See Section 5 – General directions for use
4.5. Use description
| Product type | PT05 – Drinking water (Disinfectants) |
| Where relevant, an exact description of the authorised use | / |
| Target organism(s) (including development stage) | Scientific name: bacteriaCommon name: BacteriaDevelopment stage:Scientific name: virusesCommon name: VirusesDevelopment stage: |
| Field(s) of use | IndoorOutdoorDisinfection of drinking water for animals (with water coming from tap water network) in agricultural areas, by continuous dosing. |
| Application method(s) | Method: Closed systemDetailed description:Automated dosing system |
| Application rate(s) and frequency | Application Rate: 0,5 mg/l active chlorine (AC) as residual concentration in the system.Dilution (%): –Number and timing of application:Frequency: continuous dosing |
| Category(ies) of users | Professional |
| Pack sizes and packaging material | Cylinder: 4,8-140 l (6-175 kg Cl2)Drum: 400-1000 l (500-1250 kg Cl2)Railway tanks: 43000-44000 l (53750-55000 kg Cl2)Carbon/stainless steel |
4.5.1. Use-specific instructions for use
Connect the chlorine cylinder or drum to the automated, closed dosing system. Set up the parameters of the system to obtain a continuous active chlorine concentration in the water according to the application rate indicated above.
4.5.2. Use-specific risk mitigation measures
For food commodities, ensure that the concentration of chlorate present in food does not exceed the MRL values set in Commission Regulation (EU) 2020/749 of 4 June 2020 amending Annex III to Regulation (EC) No 396/2005 of the European Parliament and of the Council as regards maximum residue levels for chlorate in or on certain products (OJ L 178, 8.6.2020, p. 7).
4.5.3. Where specific to the use, the particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
See Section 5 – General directions for use
4.5.4. Where specific to the use, the instructions for safe disposal of the product and its packaging
See Section 5 – General directions for use
4.5.5. Where specific to the use, the conditions of storage and shelf-life of the product under normal conditions of storage
See Section 5 – General directions for use
5. GENERAL DIRECTIONS FOR USEInstructions for use, risk mitigation measures and other directions for use under this section are valid for any authorised uses.
5.1. Instructions for use
–
5.2. Risk mitigation measures
—an alarm system (trigger value corresponding to the acute exposure concentration (AEC): 0,5 mg active chlorine/m3 (or lower according to national legislation) which initiates safety procedures like wearing respiratory protective equipment (RPE) according to CEN standard EN14387: Respiratory protective devices – Gas filter(s) and combined filter(s) – Requirements, testing, marking (or equivalent);
—application of local exhaust ventilation (LEV) (according to the national legislation) and low-pressure/vacuum are in place to avoid chlorine emission;
—the electrochemical sensors used for measurements to detect various chlorinated species in addition to chlorine itself;
—sensors to measure exposure also when the operators are using RPE according to CEN standard EN141 or equivalent.
For connecting or disconnecting the product containers as well as for maintenance or repair of the gas pipe system, the following risk mitigation measures (RMMs) are mandatory:
5.3. Particulars of likely direct or indirect effects, first aid instructions and emergency measures to protect the environment
Avoid breathing this toxic gas as much as possible. IF INHALED: Move to fresh air and keep at rest in a position comfortable for breathing. Immediately call 112/ambulance for medical assistance.
Information for healthcare personnel/doctor:
Immediately initiate life support measures, thereafter call a POISON CENTRE.
IF SWALLOWED: Not applicable.
IF ON SKIN: Take off all contaminated clothing and wash it before reuse. Wash skin with water. If skin irritation occurs: Get medical advice.
IF IN EYES: Rinse with water. Remove contact lenses, if present and easy to do. Continue rinsing for 5 minutes. Call a POISON CENTRE or a doctor.
5.4. Instructions for safe disposal of the product and its packaging
At the end of the treatment, dispose of unused product and the packaging in accordance with local requirements.
Do not discharge unused product on the ground, into water courses, into pipes (sink, toilets…) or down the drains.
5.5. Conditions of storage and shelf-life of the product under normal conditions of storage
Storage conditions:
Airtight pressure tanks: Due to its chemical and physical properties, chlorine gas is always stored in dedicated carbon/steel recipients with special, dedicated valves. Chlorine packages for use within the EU should be constructed and labelled according to Directive 2010/35/EU of the European Parliament and of the Council (5) and the Agreement concerning the International Carriage of Dangerous Goods by Road (ADR) done at Geneva on 30 September 1957. See section 6 for further reference. Maximum filling 1,25 kg/l (80 % of volume approx.).
Keep containers with chlorine tightly closed and store in a cool, dry and well-ventilated place. Tightly screw on the valve outlet protection seal and the valve protection cap when storing. Prevent cylinders from falling over. Protect from heat and direct sunlight, the temperature of the container should never be below 15 °C or above 50 °C.
Chlorine should be kept away from reactive products (materials to avoid: reducing agents, combustible materials, metals in powder, acetylene, hydrogen, ammonia, hydrocarbons and organic materials).
6. Other information
With respect to the ‘Category(ies) of users’ note:
Professionals (including industrial users) means trained professionals if this is required by national legislation.
(1)German Drinking Water Ordinance: Trinkwasserverordnung in der Fassung der Bekanntmachung vom 10. März 2016 (BGBl. I S. 459), die zuletzt durch Artikel 1 der Verordnung vom 22. September 2021 (BGBl. I S. 4343) geändert worden ist; list of treatment substances and disinfection processes of paragraph 11 of the German Drinking Water Ordinance: Bekanntmachung des Umweltbundesamtes der Liste der Aufbereitungsstoffe und Desinfektionsverfahren gemäß § 11 der Trinkwasserverordnung – 21. Änderung – (Stand: Dezember 2019).(2)Deutscher Verein des Gas- und Wasserfaches e.V. (German Technical and Scientific Association for Gas and Water).(3)Part II, Lfd. Nr.4 of the list of treatment substances and disinfection processes of paragraph 11 of the German Drinking Water Ordinance.(4)Part I c, Lfd. Nr.2 of the list of treatment substances and disinfection processes of paragraph 11 of the German Drinking Water Ordinance.(5)Directive 2010/35/EU of the European Parliament and of the Council of 16 June 2010 on transportable pressure equipment and repealing Council Directives 76/767/EEC, 84/525/EEC, 84/526/EEC, 84/527/EEC and 1999/36/EC (OJ L 165, 30.6.2010, p. 1).
Source: EUR-Lex, © European Union, 1998-2026. Reuse authorised under Decision 2011/833/EU.