law://eu/dec/2010/368@2026-11-18THE EUROPEAN COMMISSION,Having regard to the Treaty on the Functioning of the European Union,Having regard to Decision No 676/2002/EC of the European Parliament and of the Council of 7 March 2002 on a regulatory framework for radio spectrum policy in the European Community (Radio Spectrum Decision)note, and in particular Article 4(3) thereof,Whereas:
HAS ADOPTED THIS DECISION:
| Type of short-range device | Frequency bandnote | Transmit power limit/field strength limit/power density limitnote | Additional parameters (channelling and/or channel access and occupation rules)note | Other usage restrictionsnote | Implementation deadline |
|---|---|---|---|---|---|
| Non-specific short-range devicesnote | 6765-6795 kHz | 42 dBμA/m at 10 metres | 1 October 2008 | ||
| 13,553-13,567 MHz | 42 dBμA/m at 10 metres | 1 October 2008 | |||
| 26,957-27,283 MHz | 10 mW effective radiated power (e.r.p.), which corresponds to 42 dBμA/m at 10 metres | Video applications are excluded | 1 June 2007 | ||
| 40,660-40,700 MHz | 10 mW e.r.p. | Video applications are excluded | 1 June 2007 | ||
| Non-specific short-range devices (cont.) | 433,050-434,040note MHz | 1 mW e.r.p.and – 13 dBm/10 kHz power density for bandwidth modulation larger than 250 kHz | Voice applications allowed with advanced mitigation techniques | Audio and video applications are excluded |
Source: EUR-Lex, © European Union, 1998-2026. Reuse authorised under Decision 2011/833/EU.
| 10 mW e.r.p. | Duty cycle limitnote: 10 % | Analogue audio applications other than voice are excluded. Analogue video applications are excluded | 1 November 2010 |
| 434,040-434,790note MHz | 1 mW e.r.p.and – 13 dBm/10 kHz power density for bandwidth modulation larger than 250 kHz | Voice applications allowed with advanced mitigation techniques | Audio and video applications are excluded | 1 November 2010 |
| 10 mW e.r.p. | Duty cycle limitnote: 10 % | Analogue audio applications other than voice are excluded. Analogue video applications are excluded | 1 November 2010 |
| Duty cycle limitnote: 100 % subject to channel spacing up to 25 kHzVoice applications allowed with advanced mitigation techniques | Audio and video applications are excluded | 1 November 2010 |
| Non-specific short-range devices (cont.) | 863,000-865,000 MHz | 25 mW e.r.p. | Techniques to access spectrum and mitigate interference that provide at least equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC must be used. Alternatively a duty cycle limitnote of 0,1 % may also be used | Analogue audio applications other than voice are excluded. Analogue video applications are excluded | 1 November 2010 |
| 865,000-868,000 MHz | 25 mW e.r.p. | Techniques to access spectrum and mitigate interference that provide at least equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC must be used. Alternatively a duty cycle limitnote of 1 % may also be used | Analogue audio applications other than voice are excluded. Analogue video applications are excluded | 1 November 2010 |
| 868,000-868,600 MHz | 25 mW e.r.p. | Techniques to access spectrum and mitigate interference that provide at least equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC must be used. Alternatively a duty cycle limitnote of 1 % may also be used | Analogue video applications are excluded | 1 November 2010 |
| 868,700-869,200 MHz | 25 mW e.r.p. | Techniques to access spectrum and mitigate interference that provide at least equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC must be used. Alternatively a duty cycle limitnote of 0,1 % may also be used | Analogue video applications are excluded | 1 November 2010 |
| Non-specific short-range devices (cont.) | 869,400-869,650note MHz | 500 mW e.r.p. | Techniques to access spectrum and mitigate interference that provide at least equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC must be used. Alternatively a duty cycle limitnote of 10 % may also be usedChannel spacing must be 25 kHz, except that the whole band may also be used as a single channel for high-speed data transmission | Analogue video applications are excluded | 1 November 2010 |
| 25 mW e.r.p. | Techniques to access spectrum and mitigate interference that provide at least equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC must be used. Alternatively a duty cycle limitnote of 0,1 % may also be used | Analogue audio applications other than voice are excluded. Analogue video applications are excluded | 1 November 2010 |
| 869,700-870,000note MHz | 5 mW e.r.p. | Voice applications allowed with advanced mitigation techniques | Audio and video applications are excluded | 1 June 2007 |
| 25 mW e.r.p. | Techniques to access spectrum and mitigate interference that provide at least equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC must be used. Alternatively a duty cycle limitnote of 1 % may also be used | Analogue audio applications other than voice are excluded. Analogue video applications are excluded | 1 November 2010 |
| Non-specific short-range devices (cont.) | 2400-2483,5 MHz | 10 mW equivalent isotropic radiated power (e.i.r.p.) | 1 June 2007 |
| 5725-5875 MHz | 25 mW e.i.r.p. | 1 June 2007 |
| 24,150-24,250 GHz | 100 mW e.i.r.p. | 1 October 2008 |
| 61,0-61,5 GHz | 100 mW e.i.r.p. | 1 October 2008 |
| Wideband data transmission systems | 2400-2483,5 MHz | 100 mW e.i.r.p.and 100 mW/100 kHz e.i.r.p. density applies when frequency hopping modulation is used, 10 mW/MHz e.i.r.p. density applies when other types of modulation are used | Techniques to access spectrum and mitigate interference that provide at least equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC must be used | 1 November 2009 |
| 57,0-66,0 GHz | 40 dBm e.i.r.p.and 13 dBm/MHz e.i.r.p. density | Techniques to access spectrum and mitigate interference that provide at least equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC must be used | Fixed outdoor installations are excluded | 1 November 2010 |
| Alarm systems | 868,600-868,700 MHz | 10 mW e.r.p. | Channel spacing: 25 kHzThe whole frequency band may also be used as a single channel for high-speed data transmissionDuty cycle limitnote: 1,0 % | 1 October 2008 |
| 869,250-869,300 MHz | 10 mW e.r.p. | Channel spacing: 25 kHzDuty cycle limitnote: 0,1 % | 1 June 2007 |
| 869,300-869,400 MHz | 10 mW e.r.p. | Channel spacing: 25 kHzDuty cycle limitnote: 1,0 % | 1 October 2008 |
| 869,650-869,700 MHz | 25 mW e.r.p. | Channel spacing: 25 kHzDuty cycle limitnote: 10 % | 1 June 2007 |
| Social alarmsnote | 869,200-869,250 MHz | 10 mW e.r.p. | Channel spacing: 25 kHzDuty cycle limitnote: 0,1 % | 1 June 2007 |
| Inductive applicationsnote | 9,000-59,750 kHz | 72 dBμA/m at 10 metres | 1 November 2010 |
| 59,750-60,250 kHz | 42 dBμA/m at 10 metres | 1 June 2007 |
| 60,250-70,000 kHz | 69 dBμA/m at 10 metres | 1 June 2007 |
| 70-119 kHz | 42 dBμA/m at 10 metres | 1 June 2007 |
| 119-127 kHz | 66 dBμA/m at 10 metres | 1 June 2007 |
| 127-140 kHz | 42 dBμA/m at 10 metres | 1 October 2008 |
| 140-148,5 kHz | 37,7 dBμA/m at 10 metres | 1 October 2008 |
| 148,5-5000 kHzIn the specific bands mentioned below, higher field strengths and additional usage restrictions apply: | – 15 dBμA/m at 10 metres in any bandwidth of 10 kHzFurthermore the total field strength is – 5 dΒμΑ/m at 10 m for systems operating at bandwidths larger than 10 kHz | 1 October 2008 |
| Inductive applications (cont.) | 400-600 kHz | – 8 dBμA/m at 10 metres | This set of usage conditions applies to RFIDnote only | 1 October 2008 |
| 3155-3400 kHz | 13,5 dBμA/m at 10 metres | 1 October 2008 |
| 5000-30000 kHzIn the specific bands mentioned below, higher field strengths and additional usage restrictions apply: | – 20 dBμA/m at 10 metres in any bandwidth of 10 kHzFurthermore the total field strength is -5 dΒμΑ/m at 10 m for systems operating at bandwidths larger than 10 kHz | 1 October 2008 |
| 6765-6795 kHz | 42 dBμA/m at 10 metres | 1 June 2007 |
| 7400-8800 kHz | 9 dBμA/m at 10 metres | 1 October 2008 |
| 10200-11000 kHz | 9 dBμA/m at 10 metres | 1 October 2008 |
| Inductive applications (cont.) | 13553-13567 kHz | 42 dBμA/m at 10 metres | 1 June 2007 |
| 60 dBμA/m at 10 metres | This set of usage conditions applies to RFIDnote and EASnote only | 1 October 2008 |
| 26957-27283 kHz | 42 dBμA/m at 10 metres | 1 October 2008 |
| Active medical implantsnote | 9-315 kHz | 30 dBμA/m at 10 metres | Duty cycle limitnote: 10 % | 1 October 2008 |
| 30,0-37,5 MHz | 1 mW e.r.p. | Duty cycle limitnote: 10 % | This set of usage conditions applies to ultra low power medical membrane implants for blood pressure measurements only | 1 November 2010 |
| 402-405 MHz | 25 μW e.r.p. | Channel spacing: 25 kHzIndividual transmitters may combine adjacent channels for increased bandwidth up to 300 kHz.Other techniques to access spectrum or mitigate interference, including bandwidths greater than 300 kHz, can be used provided they result at least in an equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC to ensure compatible operation with the other users and in particular with meteorological radiosondes | 1 November 2009 |
| Active medical implants and associated peripheralsnote | 401-402 MHz | 25 μW e.r.p. | Channel spacing: 25 kHzIndividual transmitters may combine adjacent channels for increased bandwidth up to 100 kHz.Techniques to access spectrum and mitigate interference that provide at least equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC must be used. Alternatively a duty cycle limitnote of 0,1 % may also be used | 1 November 2010 |
| 405-406 MHz | 25 μW e.r.p. | Channel spacing: 25 kHzIndividual transmitters may combine adjacent channels for increased bandwidth up to 100 kHz.Techniques to access spectrum and mitigate interference that provide at least equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC must be used. Alternatively a duty cycle limitnote of 0,1 % may also be used | 1 November 2010 |
| Animal implantable devicesnote | 315-600 kHz | – 5 dΒμΑ/m at 10 m | Duty cycle limitnote : 10 % | 1 November 2010 |
| 12,5-20,0 MHz | – 7 dΒμΑ/m at 10 m in a bandwidth of 10 kHz | Duty cycle limitnote: 10 % | This set of usage conditions applies to indoor applications only | 1 November 2010 |
| Low power FM transmittersnote | 87,5-108,0 MHz | 50 nW e.r.p. | Channel spacing up to 200 kHz | 1 November 2010 |
| Wireless audio applicationsnote | 863-865 MHz | 10 mW e.r.p. | 1 November 2010 |
| Radio determination applicationsnote | 2400-2483,5 MHz | 25 mW e.i.r.p. | 1 November 2009 |
| 17,1-17,3 GHz | 26 dBm e.i.r.p. | Techniques to access spectrum and mitigate interference that provide at least equivalent performance to the techniques described in harmonised standards adopted under Directive 1999/5/EC must be used | This set of usage conditions applies to ground-based systems only | 1 November 2009 |
| Tank Level Probing Radarnote | 4,5-7,0 GHz | 24 dBm e.i.r.p.note | 1 November 2009 |
| 8,5-10,6 GHz | 30 dBm e.i.r.p.note | 1 November 2009 |
| 24,05-27,0 GHz | 43 dBm e.i.r.p.note | 1 November 2009 |
| 57,0-64,0 GHz | 43 dBm e.i.r.p.note | 1 November 2009 |
| 75,0-85,0 GHz | 43 dBm e.i.r.p.note | 1 November 2009 |
| Model Controlnote | 26990-27000 kHz | 100 mW e.r.p. | 1 November 2009 |
| 27040-27050 kHz | 100 mW e.r.p. | 1 November 2009 |
| 27090-27100 kHz | 100 mW e.r.p. | 1 November 2009 |
| 27140-27150 kHz | 100 mW e.r.p. | 1 November 2009 |
| 27190-27200 kHz | 100 mW e.r.p. | 1 November 2009 |
| Radio Frequency Identification (RFID) | 2446-2454 MHz | 100 mW e.i.r.p. | 1 November 2009 |
| Road Transport and Traffic Telematics | 76,0-77,0 GHz | 55 dBm peak e.i.r.p. and 50 dBm mean e.i.r.p. and 23,5 dBm mean e.i.r.p. for pulse radars | This set of usage conditions applies to terrestrial vehicle and infrastructure systems only | 1 November 2010 |