law://eu/dec/2005/42@2026-11-15THE COMMISSION OF THE EUROPEAN COMMUNITIES,Having regard to the Treaty establishing the European Community,Having regard to Council Decision 2003/269/EC of 8 April 2003 concerning the conclusion on behalf of the Community of the Agreement between the Government of the United States of America and the European Community on the coordination of energy-efficient labelling programmes for office equipmentnote, and in particular Article 3(3) thereof,Whereas:
DECIDES:
| Resolution | Total pixels | Maximum power use for Tier 1 |
|---|---|---|
| 640 × 480 | 307200 | 42 watts |
| 800 × 600 | 480000 | 49 watts |
| 1024 × 768 | 786432 | 60 watts |
| 1280 × 768 | 983040 | 68 watts |
| 1280 × 1024 | 1310720 | 80 watts |
| 1600 × 1024 | 1638400 | 93 watts |
| 1600 × 1200 | 1920000 | 103 watts |
| 1920 × 1200 | 2304000 | 118 watts |
| 1800 × 1440 | 2592000 | 129 watts |
| 2048 × 1440 | 2949120 | 143 watts |
| 2048 × 1536 | 3145728 | 150 watts |
| Tier 1 | Tier 2 | |
|---|---|---|
| Sleep Mode | ≤ 4 watts | ≤ 2 watts |
| Off Mode | ≤ 2 watts | ≤ 1 watt |
| Supply voltagenote | Europe: | 230 (± 1 %) volts AC, 50 Hz (± 1 %) |
| North America: | 115 (± 1 %) volts AC, 60 Hz (± 1 %) | |
| Australia/New Zealand: | 230 (± 1 %) volts AC, 50 Hz (± 1 %) | |
| Japan: | 100 (± 1 %) volts AC, 50 Hz (± 1 %)/60 Hz (± 1 %) | |
| Total harmonic distortion (voltage): | < 2 % THD | |
| Ambient temperature: | 20 °C ± 5 °C | |
| Relative humidity: | 30–80 % | |
| Line impedance: | < 0,25 ohm |
Source: EUR-Lex, © European Union, 1998-2026. Reuse authorised under Decision 2011/833/EU.