Contents
- Whereas, pursuant to subsection 332(1) of the Canadian Env…
- Overview
- Interpretation
- Application
- Requirements
- Quantification Rules
- Reporting, Sending, Recording and Retaining Information
- Coming into Force
- Schedule 1 Annual Report — Information Required (Subsection 7(3), paragraphs 21(1)(a) and (b) and subsection 21(5))
- Schedule 2 (Subsections 14(1) and 15(2))
- Schedule 3 CEMS Auditor’s Report — Information Required (Subsection 16(2))
- Schedule 4 Performance Test Report — Information Required (Subsection 22(1))
- Schedule 5 Initial Performance Test Verifier’s Report — Information Required (Subsection 22(2))
- Amendments not in force
Whereas, pursuant to subsection 332(1) of the Canadian Environmental Protection Act, 1999, the Minister of the Environment published in the Canada Gazette, Part I, on February 17, 2018, a copy of the proposed Regulations Limiting Carbon Dioxide Emissions from Natural Gas-fired Generation of Electricity, substantially in the annexed form, and persons were given an opportunity to file comments with respect to the proposed Regulations or to file a notice of objection requesting that a board of review be established and stating the reasons for the objection;Whereas, pursuant to subsection 93(3) of that Act, the National Advisory Committee has been given an opportunity to provide its advice under section 6 of that Act;And whereas, in accordance with subsection 93(4) of that Act, the Governor in Council is of the opinion that the proposed Regulations do not regulate an aspect of a substance that is regulated by or under any other Act of Parliament in a manner that provides, in the opinion of the Governor in Council, sufficient protection to the environment and human health;Therefore, Her Excellency the Governor General in Council, on the recommendation of the Minister of the Environment and the Minister of Health, pursuant to subsections 93(1) and 330(3.2) of the Canadian Environmental Protection Act, 1999, makes the annexed Regulations Limiting Carbon Dioxide Emissions from Natural Gas-fired Generation of Electricity.notenotenotenote
Overview
1Purpose#
Interpretation
2Definitions#
Application
3New generation of electricity — boiler units#
Requirements
Emission Intensity Limits
4General#
Performance Tests — Significantly Modified Boiler Units
5Initial performance test#
6Requirement#
Emergency Circumstances
7Application for exemption#
8Application for extension of exemption#
Accuracy of Data
9Measuring devices — installation, maintenance and calibration#
10Certification of CEMS#
Quantification Rules
Production of Energy
11Quantity of energy#
CO2 Emissions
Quantification Methods
Continuous Emission Monitoring System
13Unit not combusting biomass#
14Unit combusting biomass#
15Multiple CEMS per unit#
16If using a CEMS#
Fuel-based Method
17Quantification#
18Measured carbon content#
Sampling and Missing Data
19Sampling#
20Missing data#
Reporting, Sending, Recording and Retaining Information
21Annual reports#
22Performance test reporting#
23Electronic report, notice and application#
24Maintain copy#
25Retention of records and reports#
Coming into Force
26Registration#
Schedule 1 · Annual Report — Information Required (Subsection 7(3), paragraphs 21(1)(a) and (b) and subsection 21(5))
1 The following information respecting the responsible person:(a) an indication of whether they are the owner or operator of the unit and their name and civic address;(b) the name, title, civic and postal addresses, telephone number and, if any, email address and fax number of their authorized official; and(c) the name, title, civic and postal addresses, telephone number and, if any, email address and fax number of a contact person, if different from the authorized official.2 The following information respecting the unit:(a) for each responsible person for the unit, other than the responsible person mentioned in paragraph 1(a), if any,(i) their name, title and civic address, and(ii) an indication of whether they are the owner or operator;(b) the unit’s name and civic address, if any;(c) the unit’s registration number, if any;(d) the name of the facility where the unit is located;(e) the facility’s National Pollutant Release Inventory identification number assigned by the Minister for the purposes of section 48 of the Act, if any;(f) the unit’s registration number, if any, assigned by the Minister under subsection 4(2) of the Reduction of Carbon Dioxide Emissions from Coal-fired Generation of Electricity Regulations;(g) whether the unit is a boiler unit or a combustion engine unit;(h) a process flow diagram that shows(i) the unit’s major equipment that operates together to generate electricity and, if applicable, produce thermal energy, including boilers, combustion engines, duct burners and other combustion devices, heat recovery systems, steam turbines, generators and emission control devices,(ii) the unit boundaries used to identify the unit,(iii) the electric flows crossing the unit boundaries, and(iv) the heat streams crossing the unit boundaries and an indication of their average temperature, pressure and hourly mass flow rate;(i) the unit’s capacity;(j) for each of the unit’s combustion engines, the engine capacity and the date on which each combustion engine was installed, and in the case of combustion engine with a capacity of 150 MW or less, a statement that, if applicable, the combustion engine was installed to replace an engine, with a capacity of 150 MW or less, as part of repair or maintenance;(k) the unit’s potential electrical output for the calendar year, expressed in GWh;(l) as the case may be,(i) in the case of a combustion engine unit, the percentage of the unit’s potential electrical output that is sold or distributed to the electric grid for the calendar year, and(ii) in the case of a boiler unit, the quantity of electricity that is sold or distributed to the electric grid for the calendar year;(m) the percentage of the unit’s heat input that comes from natural gas, on average for the calendar year; and(n) in the case of a boiler unit, the value of the unit’s heat to electricity ratio.3 The following information respecting the emission intensity referred to in subsection 4(1) or (2) of these Regulations resulting from the combustion of fossil fuel in the unit during the calendar year:(a) the emission intensity for the unit — that is, the ratio of the quantity of CO2 emissions referred to in paragraph (c) to the quantity of energy referred to in subparagraph (b)(i) — expressed in tonnes per GWh;(b) in respect of the quantity of energy produced by the unit,(i) that quantity determined in accordance with section 11 of these Regulations, expressed in GWh,(ii) the value determined for G and Hpnet in the formula set out in subsection 11(1) of these Regulations, expressed in GWh, and(iii) the value determined for Gce, Gs and Gext in the formula set out in subsection 11(2) of these Regulations, expressed in GWh;(c) in respect of the quantity of CO2 emissions from the combustion of fuels in the unit,(i) if paragraph 12(a) of these Regulations applies, the result of the calculation made in accordance with section 13 or 14 and, if applicable, section 15 of these Regulations, expressed in tonnes, and(ii) if paragraph 12(b) of these Regulations applies, the result of the calculation made in accordance with sections 17 and 18 of these Regulations, expressed in tonnes; and(d) for each type of fuel combusted,(i) the type and, if that type is biomass, an explanation of why that type is biomass as defined in subsection 2(1) of these Regulations, and(ii) the quantity of fuel combusted.4 The following information:(a) in the case of a unit that is granted an exemption under paragraph 7(4)(a) of these Regulations, the duration of the emergency circumstance, such as the date on which the circumstance arose and the date on which it ceased; and(b) in the case of a unit referred to in subsection 4(4) of these Regulations that is temporarily connected to one or more replacement combustion engines,(i) the duration of the repairs or maintenance, such as the day in the calendar year on which the repairs or maintenance began and the day in the calendar year on which they ended, and(ii) the reason why the replacement combustion engine was used.5 A copy of the auditor’s report referred to in subsection 16(2) of these Regulations.6 The following information respecting the replacement data referred to in section 20 of these Regulations that were used for a given period during the calendar year, if applicable:(a) the reason why data required to determine the value of an element of a formula referred to in section 11, 17 or 18 of these Regulations was not obtained and an explanation why that reason was beyond the responsible person’s control;(b) the element of the formula for which data was not obtained and the date of the day on which the data were not obtained and, if that data were not obtained for a period of several days, the dates of the days on which the period begins and ends; and(c) the value determined for the element referred to in paragraph (b) using replacement data, along with details of that determination, including(i) the data used to make that determination for each period of one or more days,(ii) the method used to obtain that data, and(iii) in the case of a determination of the value of an element referred to in subsection 20(3) of these Regulations, a justification for the given period being used as the basis of that determination.
Schedule 2 · (Subsections 14(1) and 15(2))
| Column 1 | Column 2Item | Fuel type | Default higher heating value (GJ/kL)21 | Distillate fuel oil No.1 | 38.782 | Distillate fuel oil No. 2 | 38.503 | Distillate fuel oil No. 4 | 40.734 | Kerosene | 37.685 | Liquefied petroleum gases (LPG) | 25.666 | Propane (pure, not mixtures of LPGs)1 | 25.317 | Propylene | 25.398 | Ethane | 17.229 | Ethylene | 27.9010 | Isobutane | 27.0611 | Isobutylene | 28.7312 | Butane | 28.4413 | Butylene | 28.7314 | Natural gasoline | 30.6915 | Motor gasoline | 34.8716 | Aviation gasoline | 33.5217 | Kerosene-type aviation | 37.6618 | Pipeline quality natural gas | 0.037932
Schedule 3 · CEMS Auditor’s Report — Information Required (Subsection 16(2))
1 The name, civic address and telephone number of the responsible person.2 The name, civic address, telephone number and qualifications of the auditor and, if any, the auditor’s email address and fax number.3 The procedures followed by the auditor to assess whether(a) the responsible person’s use of the CEMS complied with the Quality Assurance/Quality Control manual referred to in section 6.1 of the Reference Method; and(b) the responsible person complied with the Reference Method and the CEMS met the specifications set out in the Reference Method, in particular, in its sections 3 and 4.4 A statement of the auditor’s opinion as to whether(a) the responsible person’s use of the CEMS complied with the Quality Assurance/Quality Control manual referred to in Section 6.1 of the Reference Method; and(b) the responsible person complied with the Reference Method and the CEMS met the specifications set out in the Reference Method, in particular, in its sections 3 and 4.5 A statement of the auditor’s opinion as to whether the responsible person has ensured that the Quality Assurance/Quality Control manual has been updated in accordance with sections 6.1 and 6.5.2 of the Reference Method.
Schedule 4 · Performance Test Report — Information Required (Subsection 22(1))
1 The following information respecting the responsible person:(a) an indication of whether they are the owner or operator of the unit and their name and civic address;(b) the name, title, civic and postal addresses, telephone number and, if any, email address and fax number of their authorized official; and(c) the name, title, civic and postal addresses, telephone number and, if any, email address and fax number of a contact person, if different from the authorized official.2 The following information respecting the unit:(a) for each responsible person for the unit, other than the responsible person mentioned in paragraph 1(a), if any,(i) their name, title and civic address, and(ii) an indication of whether they are the owner or operator;(b) the unit’s name and civic address, if any;(c) the unit’s registration number, if any;(d) the name of the facility where the unit is located;(e) the facility’s National Pollutant Release Inventory identification number assigned by the Minister for the purposes of section 48 of the Act, if any;(f) the unit’s registration number assigned by the Minister under subsection 4(2) of the Reduction of Carbon Dioxide Emissions from Coal-fired Generation of Electricity Regulations; and(g) the unit’s capacity.3 The following information respecting the emission intensity referred to in subsection 4(2) of these Regulations resulting from the combustion of fuel in the unit during the performance test period:(a) the emission intensity for the unit — that is, the ratio of the quantity of CO2 emissions referred to in paragraph (c) to the quantity of energy referred to in paragraph (b) — expressed in tonnes per GWh;(b) in respect of the quantity of electricity generated by the unit, the value determined for G;(c) in respect of the quantity of CO2 emissions from the combustion of fuel in the unit,(i) if paragraph 12(a) of these Regulations applies, the result of the calculation made in accordance with section 13 or 14 and, if applicable, section 15 of these Regulations, expressed in tonnes, or(ii) if paragraph 12(b) of these Regulations applies, the result of the calculation made in accordance with sections 17 and 18 of these Regulations, expressed in tonnes; and(d) in respect of each type of fuel combusted, the quantity combusted.4 The date that the test was performed.
Schedule 5 · Initial Performance Test Verifier’s Report — Information Required (Subsection 22(2))
1 The name, civic address and telephone number of the responsible person.2 The name, civic address, telephone number and qualifications of the performance test verifier and, if any, the performance test verifier’s email address and fax number.3 The procedures followed by the performance test verifier to assess whether the performance test result was obtained in accordance with section 5 of these Regulations.4 A statement of the performance test verifier’s opinion as to whether the performance test result was obtained in accordance with section 5 of these Regulations.
Amendments not in force
— SOR/2024-263, s. 50Section 3 of the Regulations Limiting Carbon Dioxide Emissions from Natural Gas-fired Generation of Electricity is amended by adding the following after subsection (6):noteThese Regulations do not apply to a unit if it is subject toan emission limit under subsection 9(1) of the Clean Electricity Regulations; oran exemption, under subsection 14(1) of those Regulations, from the application of that subsection. — SOR/2024-263, s. 52The Regulations Limiting Carbon Dioxide Emissions from Natural Gas-fired Generation of Electricity are repealed.
Federal laws of Canada reproduced under the Reproduction of Federal Law Order (SI/97-5); not the official version. Source: Justice Laws Website.