(1)The energy efficiency standards set out in column 3 of Table 1 to this section apply to large heat pumps described in column 1 that are manufactured during the periods set out in column 4 and that have no heating section or have an electric heating section.
(2)The energy efficiency standards set out in column 3 of Table 2 to this section apply to large heat pumps described in column 1 that are manufactured during the periods set out in column 4 and that have a heating section other than an electric heating section.
(3)A large heat pump complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a large heat pump as defined in section 195. | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-98 | Energy efficiency ratio ≥ 10.1Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.2 with –8.3°C inlet air | On or after December 31, 1998 and before January 1, 20102 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 11.2 | On or after January 1, 2010 and before January 1, 20183 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-17 | Energy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 12.2 | On or after January 1, 2018 and before January 1, 20264 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 11.0Heating coefficient of performance ≥ 3.4 with 8.3°C inlet air and ≥ 2.25 with −8.3°C inlet airIEER ≥ 14.1 | On or after January 1, 20265 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-98 | Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.1 with 8.3°C inlet air and ≥ 2.0 with −8.3°C inlet air | On or after December 31, 1998 and before January 1, 20106 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.6Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.7 | On or after January 1, 2010 and before January 1, 20187 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-17 | Energy efficiency ratio ≥ 10.6Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 11.6 | On or after January 1, 2018 and before January 1, 20268 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.6Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 13.5 | On or after January 1, 20269 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 9.5Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 9.6 | On or after January 1, 2010 and before January 1, 201810 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-17 | Energy efficiency ratio ≥ 9.5Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.6 | On or after January 1, 2018 and before January 1, 202611 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 9.5Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 12.5 | On or after January 1, 2026 | Column 1 | Column 2 | Column 3 | Column 4Item | Energy-using Product | Testing Standard | Energy Efficiency Standard | Period of Manufacture1 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-98 | Energy efficiency ratio ≥ 9.9Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.2 with –8.3°C inlet air | On or after December 31, 1998 and before January 1, 20102 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.8Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 11.0 | On or after January 1, 2010 and before January 1, 20183 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-17 | Energy efficiency ratio ≥ 10.8Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.25 with –8.3°C inlet airIEER ≥ 12.0 | On or after January 1, 2018 and before January 1, 20264 | Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.8Heating coefficient of performance ≥ 3.4 with 8.3°C inlet air and ≥ 2.25 with −8.3°C inlet airIEER ≥ 13.9 | On or after January 1, 20265 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-98 | Energy efficiency ratio ≥ 9.1Heating coefficient of performance ≥ 3.1 with 8.3°C inlet air and ≥ 2.0 with −8.3°C inlet air | On or after December 31, 1998 and before January 1, 20106 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 10.4Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.5 | On or after January 1, 2010 and before January 1, 20187 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-17 | Energy efficiency ratio ≥ 10.4Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 11.4 | On or after January 1, 2018 and before January 1, 20268 | Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 10.4Heating coefficient of performance ≥ 3.3 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 13.3 | On or after January 1, 20269 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-06 for energy efficiency ratio and heating coefficient of performanceAHRI 340/360 for IEER | Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 9.4 | On or after January 1, 2010 and before January 1, 201810 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-17 | Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 10.4 | On or after January 1, 2018 and before January 1, 202611 | Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW | CSA C746-17 or 10 C.F.R. Appendix A | Energy efficiency ratio ≥ 9.3Heating coefficient of performance ≥ 3.2 with 8.3°C inlet air and ≥ 2.05 with −8.3°C inlet airIEER ≥ 12.3 | On or after January 1, 2026
note
Federal laws of Canada reproduced under the Reproduction of Federal Law Order (SI/97-5); not the official version. Source: Justice Laws Website.