law://ca/sor/2016/151@2026-11-10Whereas, pursuant to subsection 332(1) of the Canadian Environmental Protection Act, 1999, the Minister of the Environment published in the Canada Gazette, Part I, on June 7, 2014 a copy of the proposed Multi-Sector Air Pollutants Regulations, substantially in the annexed form, and persons were given an opportunity to file comments with respect to the proposed Regulations or to file a notice of objection requesting that a board of review be established and stating the reasons for the objection;notenoteWhereas, pursuant to subsection 93(3) of that Act, the National Advisory Committee has been given an opportunity to provide its advice under section 6 of that Act;noteAnd whereas, in accordance with subsection 93(4) of that Act, the Governor in Council is of the opinion that the proposed Regulations do not regulate an aspect of a substance that is regulated by or under any other Act of Parliament in a manner that provides, in the opinion of the Governor in Council, sufficient protection to the environment and human health;Therefore, His Excellency the Governor General in Council, on the recommendation of the Minister of the Environment and the Minister of Health, pursuant to subsections 93(1) and 330(3.2) of the Canadian Environmental Protection Act, 1999, makes the annexed Multi-Sector Air Pollutants Regulations.note
| Column 1 | Column 2Item | Type of Fuel | Default Higher Heating Value (GJ/t)1 | Bituminous Canadian coal — Western | 25.62 | Bituminous Canadian coal — Eastern | 27.93 | Bituminous non-Canadian coal — U.S. | 25.74 | Bituminous non-Canadian coal — other countries | 29.95 | Sub-bituminous Canadian coal — Western | 19.26 | Sub-bituminous non-Canadian coal — U.S. | 19.27 | Coal — lignite | 15.08 | Coal — anthracite | 27.79 | Coal coke and metallurgical coke | 28.810 | Petroleum coke from refineries | 46.411 | Petroleum coke from upgraders | 40.612 | Municipal solid waste | 11.513 | Tires | 31.214 | Wood and wood waste1 | 19.015 | Agricultural by-products1 | 17.016 | Peat1 | 9.3 | Column 1 | Column 2Item | Type of Fuel | Default Higher Heating Value (GJ/kl)1 | Diesel | 38.32 | Light fuel oil | 38.83 | Heavy fuel oil | 42.54 | Ethanol | 21.05 | Distillate fuel oil No. 1 | 38.786 | Distillate fuel oil No. 2 | 38.507 | Distillate fuel oil No. 4 | 40.738 | Kerosene | 37.689 | Liquefied petroleum gas (LPG) | 25.6610 | Natural gasoline | 30.69
| Percentage of Loss of Thermal EfficiencyColumn 1 | Column 2 | Column 3 | Column 4Rated Capacity (GJ/h) | 100% of Rated Capacity | 80% of Rated Capacity | 60% of
— SOR/2016-151, s. 124Section 11 of these Regulations is replaced by the following:The NOx emission intensity of a pre-existing boiler or heater that is class 80 or class 70 — other than those referred to in subsections 13(1) and 14(1) and (2 ) — and that, for a given hour, has at least 50% of the input energy in its combustion chamber resulting from the introduction of gaseous fossil fuel must not, for that hour, exceed the limit of 26 g/GJ. — SOR/2016-151, s. 125(2)The portion of subsection 12(1) of these Regulations before paragraph (a) is replaced by the following:A pre-existing boiler or is classified — in accordance with its classification NO
Federal laws of Canada reproduced under the Reproduction of Federal Law Order (SI/97-5); not the official version. Source: Justice Laws Website.