Contents
- Short Title
- Interpretation
- Application
- Substances Prescribed as Deleterious Substances
- Authorized Deposit of Deleterious Substances
- Additional Conditions of Authorization
- Schedule I (Section 5)
- Schedule II (Section 6)
- Schedule III (Section 9)
- Schedule IV Test Procedure for 96 Hour Acute Lethality Static Test (Section 9)
Short Title
Interpretation
2#
Application
3#
Substances Prescribed as Deleterious Substances
Authorized Deposit of Deleterious Substances
5#
Additional Conditions of Authorization
General
6#
Method of Collecting Composite Samples
7#
Frequency of Sampling and Analysis
8#
Analytical and Other Test Methods
9#
Flow Measurement
10#
Calculation of Actual Deposit
11#
Reporting and Records
12#
Permitted Variation in Additional Conditions
13#
Schedule I · (Section 5)
Column I | Column II | Column III | Column IVClass of Plant | Deleterious Substance | Authorized actual daily deposit | Authorized average daily depositRed Meat Integrated Plant | Biochemical Oxygen Demanding Matter | 1.0 kg/tonne of finished product | 0.5 kg/tonne of finished productTotal Suspended Matter | 1.2 kg/tonne of finished product | 0.6 kg/tonne of finished productGrease | 1.6 kg/tonne of finished product | 0.8 kg/tonne of finished productProcessing Plant | Biochemical Oxygen Demanding Matter | 0.7 kg/tonne of finished product | 0.35 kg/tonne of finished productTotal Suspended Matter | 0.5 kg/tonne of finished product | 0.25 kg/tonne of finished productGrease | 0.8 kg/tonne of finished product | 0.4 kg/tonne of finished productPoultry Integrated Plant | Biochemical Oxygen Demanding Matter | 1.4 kg/tonne of finished product | 0.7 kg/tonne of finished productTotal Suspended Matter | 1.0 kg/tonne of finished product | 0.5 kg/tonne of finished productGrease | 1.0 kg/tonne of finished product | 0.5 kg/tonne of finished productRendering Plant | Biochemical Oxygen Demanding Matter | 0.4 kg/tonne of raw material | 0.2 kg/tonne of raw materialTotal Suspended Matter | 0.4 kg/tonne of raw material | 0.2 kg/tonne of raw materialGrease | 0.3 kg/tonne of raw material | 0.15 kg/tonne of raw material
Schedule II · (Section 6)
| Column I | Column II | Class and Size of Plant | Frequency of Sampling and Testing1Red meat integrated plant producing annually | (a)Less than 500 tonnes of finished product | On one slaughtering day per calendar year(b)Between 500 and 10 000 tonnes of finished product | On two slaughtering days per calendar year, at intervals greater than four calendar months(c)Over 10 000 tonnes of finished product | On one slaughtering day during each 13 week period of the calendar year, at intervals greater than one calendar month2Processing plant producing annually | (a)Less than 500 tonnes of finished product | On one processing day per calendar year(b)Over 500 tonnes of finished product | On two processing days per calendar year, at intervals greater than four calendar months3Poultry integrated plant producing annually | (a)Less than 2 500 tonnes of finished product | On one slaughtering day per calendar year(b)Between 2 500 and 7 000 tonnes of finished product | On two slaughtering days per calendar year, at intervals greater than four calendar months(c)Over 7 000 tonnes of finished product | On one slaughtering day during each 13 week period of the calendar year, at intervals greater than one calendar month4Rendering plant | On one processing day during each 13 week period of the calendar year, at intervals greater than one calendar month
Schedule III · (Section 9)
| | Column I | Column IIItem | Substance | Test Method | Modifications1 | Biochemical Oxygen Demanding Matter (BOD) | APHA* Section 507 | For determining dissolved oxygen the following tests are recommended:Section 422B APHA* Phenylarseneoxide may be used instead of sodium thiosulphateSection 422F APHA* The probe must be standardized against Winkler-Azide method (APHA* Section 422B)2 | Total Suspended Matter | APHA* Section 208D | Glass fiber filter discs 4.25, 4.7 or 5.5 cm size with 3.5 m size support screen to be used Gooch crucible filtration is not recommendedGraduated cylinder is recommended to measure the sample volume3 | Grease | APHA* Section 502C | Either hexane or trichlorotrifluoroethane can be used4 | Ammonia Nitrogen | APHA* Section 418 | Where appropriate the test methods referred to in Section 418A or 418B should be used.note
Schedule IV · Test Procedure for 96 Hour Acute Lethality Static Test (Section 9)
1#
Federal laws of Canada reproduced under the Reproduction of Federal Law Order (SI/97-5); not the official version. Source: Justice Laws Website.